0% found this document useful (0 votes)
49 views2 pages

H07V-U / - R: Low Voltage Cables ( 750V)

This document provides information about low voltage cables rated below 750V. It describes the H07V-U/R cable, which is a PVC insulated rigid copper cable suitable for protected fixed installations. The cable standards and fire classification are listed, along with the conductor and insulation materials, electrical properties, construction details, and maximum current ratings.

Uploaded by

chida moha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
49 views2 pages

H07V-U / - R: Low Voltage Cables ( 750V)

This document provides information about low voltage cables rated below 750V. It describes the H07V-U/R cable, which is a PVC insulated rigid copper cable suitable for protected fixed installations. The cable standards and fire classification are listed, along with the conductor and insulation materials, electrical properties, construction details, and maximum current ratings.

Uploaded by

chida moha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

LOW VOLTAGE CABLES (< 750V)

H07V-U / -R

CPR

Application Standards
PVC insulated rigid copper cables, • EN 50525-2-31
suitable for protected fixed installations, • IEC/EN 60332-1-2
in or on lighting fitting and switchgear. • EN 13501-6 & EN 50575

CPR
• Class: Eca

Design

H07V-U Eca

H07V-R Eca
•Conductor: Copper class1 to sections up to 6 mm2, acc. IEC/EN 60228 (-U)
Copper class 2 to sections above 6 mm2, acc. IEC/EN 60228 (-R)
•Insulation: PVC type TI 1
•Available on several colours, examples, BK, BN, BU, GY, GNYE, RED, VT.

Electrical properties at 20°C


Conductor Max. d.c. Technical Data
section resistance
(mm2) (Ω/km) Max. conductor
1,5 12,1 temperature (ºC): 70

2,5 7,41 Max. short circuit


4 4,61 temperature (ºC):
160 (5 minutes)
6 3,08
10 1,83
Minimum bending radius
16 1,15 At installation:
25 0,727 4 x (CD* ≤ 8 mm)
Product Information H07V-U / -R Eca - Edition: June 2021

5 x (8 mm < CD* ≤ 12 mm)


35 0,524
6 x (CD* >12 mm)
50 0,387
70 0,268 Voltage level
95 0,193 450/750 V
120 0,153
Voltage test
150 0,124
2,5 kV a.c. 5 minutes
185 0,0991
240 0,0754 *CD - Cable Diameter

1
LOW VOLTAGE CABLES (< 750V)

H07V-U / -R

Construction Approx. outer diameter Nominal weight Max. permanent


current rating
(Nxmm2) (mm) (kg/km) (A) (*)
1x1,5 2,7 20 15
1x2,5 3,3 33 21
1x4 3,7 48 28
1x6 4,3 64 36
1x10 5,8 108 50
1x16 6,7 164 68
1x25 8,3 256 89
1x35 9,4 343 110
1x50 11,0 464 134
1x70 12,5 660 171
1x95 14,7 903 207
1x120 16,1 1.141 239
1x150 18,1 1.382 262
1x185 20,1 1.747 296
1x240 22,4 2.292 346

(*)
Air at 30ºC, three loaded conductors, one circuit inside embedded conduits.
Product Information H07V-U / -R Eca - Edition: June 2021

Trademarking, an LAPP Policabos approved brand.


Photographs and graphics are not to scale and do not represent detailed images of the respective products.
All printing errors are subject to correction in subsequent releases of this document. The specifications of all products contained are subject to change without notice.