〈825〉 Radiopharmaceuticals-Preparation, Compounding, Dispensing, and Repackaging
〈825〉 Radiopharmaceuticals-Preparation, Compounding, Dispensing, and Repackaging
Printed by: Dang Van Vu Official Date: Official as of 01-Dec-2020 Document Type: GENERAL CHAPTER @2023 USPC
Do Not Distribute DOI Ref: rog9b DOI: https://doi.org/10.31003/USPNF_M11915_04_01
1
Change to read:
al
4.1 Aseptic Qualifications
4.2 Reevaluation, Retraining, and Requalification
4.3 Ancillary Personnel
4.4 Hand Hygiene and Garbing for Immediate Use Preparations
ci
4.5 Hand Hygiene and Garbing for Buffer Areas and Segregated Radiopharmaceutical Processing Areas
5. FACILITIES AND ENGINEERING CONTROLS
5.1 Facility Design and Environmental Controls
5.2 Creating Areas to Achieve Easily Cleanable Conditions
5.3 Water Sources
ffi
5.4 Placement and Movement of Materials
5.5 Classified Areas
5.6 Remote Aseptic Processing Involving a Hot-Cell
5.7 Environmental Controls
6. MICROBIOLOGICAL AIR AND SURFACE MONITORING
O
https://online.uspnf.com/uspnf/document/1_GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US 1/28
www.webofpharma.com
Printed on: Wed Feb 08 2023, 11:06:36 PM(EST) Status: Currently Official on 09-Feb-2023 DocId: GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US
Printed by: Dang Van Vu Official Date: Official as of 01-Dec-2020 Document Type: GENERAL CHAPTER @2023 USPC
Do Not Distribute DOI Ref: rog9b DOI: https://doi.org/10.31003/USPNF_M11915_04_01
2
1. INTRODUCTION
Radiopharmaceuticals, as defined in this chapter (see Glossary), are a subset of radioactive materials (RAMs) falling under the
control of the US Nuclear Regulatory Commission (NRC) or NRC-contracted agreement state agency. Radiopharmaceuticals
are also a subset of prescription drugs falling under the control of the US FDA for manufacturing and marketing. Other federal
regulatory authorities (e.g., Department of Transportation) have control over certain activities related to radiopharmaceuticals.
Compliance with these regulations, as applicable, must be ensured in addition to compliance with the standards described in
this chapter. [NOTE—Users outside the US must comply with equivalent regulations, as applicable, pertaining to
radiopharmaceuticals.]
This chapter is intended to provide uniform minimum standards for the preparation, compounding, dispensing, and
al
repackaging of sterile and nonsterile radiopharmaceuticals for humans and animals that occur as part of state-licensed activities
(e.g., the practice of pharmacy and the practice of medicine). These standards apply to all radiopharmaceutical processing
activities, including those with radionuclides that emit a single photon, a positron, or a therapeutic particle. Furthermore, these
standards apply to sterile intravascular radioactive devices (e.g., radioactive microspheres for intravascular brachytherapy).
This chapter does not apply to the following activities: ci
• Manufacturing of approved radiopharmaceuticals (e.g., NDA, ANDA, BLA) in FDA-registered manufacturing
establishments
• Manufacturing of radiopharmaceuticals as investigational agents (e.g., IND, RDRC)
• Compounding of radiopharmaceuticals in a registered FDCA §503B outsourcing facility
• Preparation/compounding of positron emission tomography (PET) drugs that are not manufactured as approved drug
ffi
products (e.g., NDA, ANDA, BLA) and conforms with Positron Emission Tomography Drugs for Compounding, Investigational,
and Research Uses á823ñ
• Administration of radiopharmaceuticals to patients
In each of these scenarios except for patient administration, the further processing and manipulation of the drug product
after release falls within the scope of this chapter.
This chapter does not apply to the preparation of non-radioactive drugs, including those used as pharmacologic adjuncts
O
for certain nuclear medicine procedures. These drugs must be prepared following standards described in Pharmaceutical
Compounding—Nonsterile Preparations á795ñ and Pharmaceutical Compounding—Sterile Preparations á797ñ.
This chapter applies to all practice settings where radiopharmaceuticals are prepared, compounded, dispensed, or
repackaged. Practice settings consist of state-licensed nuclear pharmacies, federal nuclear pharmacy facilities, and other
healthcare facilities, including, but not limited to: nuclear medicine departments in hospitals and clinics, nuclear cardiology
clinics (fixed site or mobile), and other specialty clinics.
This chapter applies to all individuals who prepare, compound, dispense, or repackage radiopharmaceuticals. Applicable
individuals consist of authorized nuclear pharmacists (ANPs) and authorized user (AU) physicians, as well as individuals working
under their supervision. This includes, but is not limited to, student pharmacists, nuclear pharmacy technicians, nuclear
medicine technologists and students, and physician residents and trainees.
US federal and state radiation regulatory authorities require limiting radiation exposure to personnel who handle
radiopharmaceuticals, which necessitates special provisions for radiation protection. The principles of radiation safety involve
time, distance, shielding, and radioactive contamination control. Moreover, the use of radiation detection and measuring
devices is a necessary component of radiopharmaceutical handling procedures. Strict adherence to all typical aseptic handling
practices is not possible in many scenarios where radiopharmaceuticals are handled. Thus, it is necessary to balance aseptic
handling practices (patient safety) with radiation protection practices (worker safety). This chapter describes appropriate
strategies that provide assurance of maintaining patient safety, while also ensuring the safety of individuals performing these
activities. Because radiopharmaceuticals represent a unique class of prescription drugs, the use of technologies, techniques,
materials, and procedures other than those described in this chapter are not prohibited so long as they are documented to be
equivalent or superior to those described herein.
https://online.uspnf.com/uspnf/document/1_GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US 2/28
www.webofpharma.com
Printed on: Wed Feb 08 2023, 11:06:36 PM(EST) Status: Currently Official on 09-Feb-2023 DocId: GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US
Printed by: Dang Van Vu Official Date: Official as of 01-Dec-2020 Document Type: GENERAL CHAPTER @2023 USPC
Do Not Distribute DOI Ref: rog9b DOI: https://doi.org/10.31003/USPNF_M11915_04_01
3
The handling of radiopharmaceuticals necessitates meeting the radiation regulatory agency requirements for worker safety.
This involves licensing commitments to keep all exposure levels for the workers involved as low as reasonably achievable (ALARA)
al
practices. Principles of radiation safety involve time, distance, shielding, and contamination control. Moreover, radiation
detection and measuring devices are necessary. Aseptic handling practices must be balanced with radiation safety
considerations, based on the following:
• Knowledge, training, experience, and professional judgment related to the type, abundance, and energy of the
radioactive emissions ci
• The quantity of radioactivity, volume, handling steps, and timing
• Other factors, which can vary on a case-by-case basis
2.1 Time
ffi
Radiation exposure to personnel is directly proportional to the quantity of radiation handled and the time handling the RAM;
minimizing handling time will minimize radiation exposure. Personnel handling radiopharmaceuticals may work quickly in a
controlled and safe manner, including multiple hand movements in and out of the ISO Class 5 primary engineering control
(PEC) during aseptic processes.
2.2 Distance
O
Radiation exposure follows the inverse square law; increasing the distance between the operator and the RAM will decrease
radiation exposure to personnel by the square of the distance. Handlers of radiopharmaceuticals may utilize techniques to
increase distance, such as using remote handling tools, including within an ISO Class 5 PEC.
2.3 Shielding
Radiation exposure to personnel decreases with the use of shielding materials. Therefore, handlers of radiopharmaceuticals
may use various shielding materials (e.g., lead, tungsten) in various configurations. The use of shielding, such as L-block, torso,
vial, and syringe shields, is usually required throughout the radiopharmaceutical handling process, including within an ISO Class
5 PEC.
https://online.uspnf.com/uspnf/document/1_GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US 3/28
www.webofpharma.com
Printed on: Wed Feb 08 2023, 11:06:36 PM(EST) Status: Currently Official on 09-Feb-2023 DocId: GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US
Printed by: Dang Van Vu Official Date: Official as of 01-Dec-2020 Document Type: GENERAL CHAPTER @2023 USPC
Do Not Distribute DOI Ref: rog9b DOI: https://doi.org/10.31003/USPNF_M11915_04_01
4
As per RAM license requirements, individuals must wear body and, as required, extremity dosimeters (e.g., a ring worn on a
finger) for long-term monitoring of personnel radiation exposure. The body dosimeter should be worn underneath the gown.
Any extremity dosimeter must be worn underneath gloves and must not interfere with proper fit of gloves.
The preparation and dispensing of sterile radiopharmaceuticals in a patient care setting may be handled as an immediate
use practice. The information below describes the appropriate handling requirements for immediate use sterile
radiopharmaceuticals in an ambient environment that lacks primary and secondary engineering controls (SEC) when intended
for a single patient. Strict aseptic technique and limited beyond-use date (BUD) must be adhered to given the lack of engineering
controls.
• Appropriate for preparation (including minor deviations) and/or dispensing that is limited to use for a single patient.
• Preparation (including preparations with minor deviations) components must be sterile, conventionally manufactured
drug products (e.g., NDA, ANDA).
• Dispensing of drug products produced under an approved IND or RDRC protocol is allowed.
• Manipulations for any unit doses (e.g., decreasing the dosage, needle changes) or dispensing for one patient (e.g.,
withdrawing a dose) is allowed.
• Must be administered within 1 hour of the first container puncture or exposure of any critical site involved (e.g., syringe
tip, needle hub or needle) to ambient air, whichever is first.
• All components involved (e.g., Tc-99m sodium pertechnetate syringe or vial, final prepared radiopharmaceutical kit vial,
diluent vial) must be discarded within 1 hour of being punctured or after use for a single patient administration, whichever
al
is first.
• Dose pooling (combining doses from two or more syringes to meet one patient’s need) may be performed as immediate
use. Any residual activity that remains must be immediately discarded and not utilized for any other patient.
• Follow hand hygiene and garbing in 4.4 Hand Hygiene and Garbing for Immediate Use Preparations.
ci
• Follow 10.4 Preparation of Radiolabeled Red Blood Cells for Immediate Use for red blood cell labeling.
• Follow 12.2 Labeling for labeling.
• Area for sterile preparation and/or dispensing must be functionally separate from nonsterile compounding area (e.g.,
radiolabeling food) during the time of use.
• Does not require a segregated radiopharmaceutical processing area (SRPA), classified area, or PEC.
ffi
• The number of steps or punctures is not limited.
• Does not require personnel to complete the aseptic qualifications as detailed in 4.1 Aseptic Qualifications (e.g., aseptic
technique training with documented assessment, media fill challenge, gloved fingertip testing).
• While adding a non-radioactive, sterile and commercially manufactured pharmaceutical (e.g., lidocaine) to a unit dose is
otherwise considered compounding, it is allowed for immediate use purposes as long as all of the above are adhered to.
• Dose splitting (splitting a unit dose for administration to more than one patient) may not be performed as immediate use;
O
if performed, dose splitting must be done in an ISO class 5 PEC in either an SRPA or in an ISO class 8 or better buffer area.
Personnel must be trained to work with radiopharmaceuticals per the policies and standard operating procedures (SOPs)
authorized by an ANP or AU physician. These individuals (e.g., nuclear medicine technologists or nuclear pharmacy technicians)
must follow these policies and SOPs of the ANP or AU physician and work under their supervision. As appropriate, this should
include blood-borne pathogens training.
Individuals entering a compounding area must be properly garbed and must maintain proper personal hygiene to minimize
the risk of contamination to the environment and/or radiopharmaceuticals. Individuals who have a condition that may pose a
higher potential of contaminating the radiopharmaceutical and the environment with microorganisms (e.g., rashes, sunburn,
recent tattoos, oozing sores, conjunctivitis, or active respiratory infection) must report these conditions to their supervisor. The
designated person is responsible for evaluating whether these individuals should be excluded from working in sterile processing
areas before their conditions are resolved.
https://online.uspnf.com/uspnf/document/1_GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US 4/28
www.webofpharma.com
Printed on: Wed Feb 08 2023, 11:06:36 PM(EST) Status: Currently Official on 09-Feb-2023 DocId: GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US
Printed by: Dang Van Vu Official Date: Official as of 01-Dec-2020 Document Type: GENERAL CHAPTER @2023 USPC
Do Not Distribute DOI Ref: rog9b DOI: https://doi.org/10.31003/USPNF_M11915_04_01
5
MEDIA-FILL TESTING
Media-fill testing is necessary for all personnel who prepare, compound, dispense, and repackage sterile
radiopharmaceuticals. This testing must be reflective of the actual manipulations to be carried out by the individual and must
al
simulate the most challenging and stressful conditions to be encountered in the worker’s duties.
• Media-fill tests must be documented as defined by the facility’s policies and SOPs.
• Media-fill tests should be performed at the end of a work session in the PEC.
• Media-fill tests must be performed with a commercial source of soybean–casein digest medium. Those performing
sterile-to-sterile processing activities must start with sterile media. Those performing nonsterile-to-sterile compounding
ci
must use a nonsterile soybean–casein digest powder to make a solution. Dissolve nonsterile commercially available
soybean–casein digest medium in nonbacteriostatic water to make a 3% nonsterile solution. Manipulate it in a manner
that simulates nonsterile-to-sterile compounding activities. Prepare at least 1 container as the positive control to
demonstrate growth promotion, which is indicated by visible turbidity upon incubation.
• The certificate of analysis (CoA) must include documentation of growth promotion testing for each lot of media used.
ffi
• Once the media-fill simulation is completed and the final containers are filled with the test medium, incubate media-filled
containers in an incubator for 7 days at 20°–25° followed by 7 days at 30°–35° to detect a broad spectrum of
microorganisms. Failure is indicated by visible turbidity or other visual manifestations of growth in the medium in 1 or
more container–closure unit(s) on or before 14 days.
• In the event of failure, results of the evaluation and corrective actions must be documented and the documentation
O
maintained to provide a record and long-term assessment of personnel competency. Documentation must at a minimum
include the name of the person evaluated, evaluation date/time, media and components used including manufacturer,
expiration date and lot number, starting temperature for each interval of incubation, dates of incubation, and the results.
REQUALIFICATION PROGRAM
Personnel must successfully complete requalification in the core competencies listed in 4.1 Aseptic Qualifications. Successful
completion must be demonstrated through observation, written testing, and hands-on demonstration of skills.
https://online.uspnf.com/uspnf/document/1_GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US 5/28
www.webofpharma.com
Printed on: Wed Feb 08 2023, 11:06:36 PM(EST) Status: Currently Official on 09-Feb-2023 DocId: GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US
Printed by: Dang Van Vu Official Date: Official as of 01-Dec-2020 Document Type: GENERAL CHAPTER @2023 USPC
Do Not Distribute DOI Ref: rog9b DOI: https://doi.org/10.31003/USPNF_M11915_04_01
6
Sterile compounding using a nonsterile drug substance or components: Personnel who perform sterile compounding
using a nonsterile drug substance or components (see 11.3 Sterile Compounding Using a Nonsterile Drug Substance or
Components) must be requalified in all core competencies every 6 months.
al
4.5 Hand Hygiene and Garbing for Buffer Areas and Segregated Radiopharmaceutical
Processing Area
In situations involving repackaging, dispensing, preparation, preparation with minor deviations, or compounding of sterile
ci
radiopharmaceuticals in an ISO Class 5 PEC, the following precautions related to personal hygiene are to be followed:
• Before entering the SRPA or buffer area, personnel must remove outer garments (e.g., bandanas, coats, hats, jackets,
sweaters, vests); all cosmetics; all hand, wrist, and other exposed jewelry including piercings that could interfere with the
effectiveness of the garbing (e.g., the fit of gloves, cuffs of sleeves, and eye protection). Nail products (e.g., artificial nails,
polish, extenders) are prohibited. Natural nails must be kept neat and trimmed. Remove ear buds and headphones.
ffi
Radiation dosimetry devices are allowed, as required by the RAM license.
• Do not bring electronic devices that are not necessary for compounding or other required tasks.
• Immediately before entering the SRPA or buffer area, remove visible debris from underneath fingernails under warm
running water using a disposable nail cleaner. Personnel must wash hands and arms up the elbows with soap and water
for at least 30 s and then dry hands using low-lint towels. Alternatively, hand washing may be performed after donning
shoe covers, head/hair covers, and face mask, as described below.
O
• Personnel must don the following garb—shoe covers, head/hair/facial hair covers, face mask—in an order that eliminates
the greatest risk of contamination, as defined in facility SOPs.
• If not already performed, remove visible debris from underneath fingernails under warm running water using a disposable
nail cleaner. Personnel must then wash hands and arms up to the elbows with soap and water for at least 30 s and then
dry hands using low-lint towels. Electronic hand dryers are not permitted.
• Personnel must then perform hand antisepsis cleansing using a suitable alcohol-based hand rub.
• Personnel must then don a low-lint gown with sleeves that fit snugly around the wrists and enclosed at the neck. Disposable
gowns are preferred. If reusable gowns are used, a clean gown must be donned daily.
• Personnel must then aseptically don sterile, powder-free gloves. Gloves must completely and snugly cover the ends of the
gown cuffs so that skin on the wrists and upper hands is completely enveloped.
• Because gloves may not remain sterile due to touching or handling potentially nonsterile materials, personnel must
periodically apply sterile 70% IPA to gloves while balancing the risk of radioactivity contamination.
• Personnel must also routinely inspect the gloves that they are wearing for holes, punctures, radioactivity contamination,
or tears. If a defect, radioactivity contamination, or malfunction is detected, personnel must immediately remove the
gloves, repeat antiseptic hand cleansing using an alcohol-based hand rub, and don new sterile gloves.
• Direct personnel touch contamination is the most common source of microorganisms, so personnel must avoid touch
contamination of container septa, needles, syringe and needle hubs, and other critical sites.
When personnel exit the buffer area or SRPA, shoe covers, head/hair covers, face masks, and gloves must be properly disposed
of and new ones donned for each reentry into the buffer area or SRPA. Gowns may be re-used within the same shift if the gown
is maintained in a classified area or in (or immediately outside of) the SRPA that minimizes contamination (e.g., away from
sinks).
https://online.uspnf.com/uspnf/document/1_GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US 6/28
www.webofpharma.com
Printed on: Wed Feb 08 2023, 11:06:36 PM(EST) Status: Currently Official on 09-Feb-2023 DocId: GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US
Printed by: Dang Van Vu Official Date: Official as of 01-Dec-2020 Document Type: GENERAL CHAPTER @2023 USPC
Do Not Distribute DOI Ref: rog9b DOI: https://doi.org/10.31003/USPNF_M11915_04_01
7
á1066ñ). The classified areas and SRPA must be continuously maintained at a temperature of 25° or cooler and should be
continuously maintained at a relative humidity (RH) below 60% to minimize the risk for microbial proliferation and provide
comfortable conditions for personnel attired in the required garb. The temperature and humidity must be monitored in the
classified areas each day that it is used, either manually or by a continuous recording device. The results of the temperature and
humidity readings must be documented at least once daily or stored in the continuous recording device, and must be retrievable.
The temperature and humidity readings must be reviewed as described in the facility’s SOPs. Free-standing humidifiers/
dehumidifiers and air conditioners must not be used within the classified area or SRPA. Temperature and humidity monitoring
devices must be verified for accuracy at least every 12 months or as required by the manufacturer.
The designated person is responsible for ensuring that each area related to sterile radiopharmaceutical processes meets the
classified air quality standard appropriate for the activities to be conducted in that area. They must also ensure that the ISO
Class 5 PECs are located, operated, maintained, monitored, and certified to have appropriate air quality.
al
must be in place to minimize the flow of lower-quality air into the more controlled areas. Air supplied to the classified areas
must be introduced through HEPA filters that are located in the ceiling. Returns must be low on the wall unless a visual smoke
study demonstrates an absence of stagnant airflow where particulate will accumulate. A smoke study of the PEC must be
repeated whenever a change to the placement of the PEC within the area is made. The classified areas must be equipped with a
pressure-differential monitoring system. The ante-room must have a line of demarcation to separate the clean side from the
ci
less clean side. The ante-room is entered through the less clean side, and the clean side is the area closest to the buffer area.
Required garb must be worn prior to crossing the line of demarcation (see 4. Personnel Qualifications, Training, and Hygiene).
A PEC may be located within an unclassified area, without an ante-room or buffer area. This type of design is called an SRPA.
Only sterile radiopharmaceutical preparation, preparation with minor deviations, dispensing, and repackaging may be
performed in an SRPA. If the SRPA meets ISO Class 8 total airborne particle count specifications, it can also be used for storage
ffi
and elution of non-direct infusion radionuclide generators (e.g., Tc-99m). The SRPA must be located away from unsealed
windows, doors that connect to the outdoors, and traffic flow which may adversely affect the air quality in the PEC. The impact
of activities that will be conducted around or adjacent to the SRPA must be considered carefully when designing such an area. A
visible perimeter must establish the boundaries of the SRPA. Access to the SRPA must be restricted to authorized personnel and
required materials. An SRPA must not be located adjacent to environmental control challenges.
It is also critical to control materials (e.g., supplies and equipment) as they move from classified areas of lower quality to
O
those of higher quality (e.g., ISO Class 8 ante-room to ISO Class 7 buffer area to ISO Class 5 PEC) to prevent the influx of
contaminants. Airlocks and interlocking doors can be used to facilitate better control of air flow between areas of differing ISO
classification (e.g., between the buffer area and ante-room), or between a classified area and an unclassified area (e.g., between
the ante-room and an unclassified area such as a hallway) See 5.7 Environmental Controls for a description of air pressure
differentials. If a pass-through is used, both doors must never be opened at the same time, which may be achieved using
interlocking mechanisms.
4 352
5 3520
6 35,200
7 352,000
8 3,520,000
https://online.uspnf.com/uspnf/document/1_GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US 7/28
www.webofpharma.com
Printed on: Wed Feb 08 2023, 11:06:36 PM(EST) Status: Currently Official on 09-Feb-2023 DocId: GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US
Printed by: Dang Van Vu Official Date: Official as of 01-Dec-2020 Document Type: GENERAL CHAPTER @2023 USPC
Do Not Distribute DOI Ref: rog9b DOI: https://doi.org/10.31003/USPNF_M11915_04_01
8
a Adapted from ISO 14644-1, Clean areas and associated controlled environments—Part 1: Classification of air cleanliness by particle concentration.
b Limits for number of particles ≥0.5 µm measured under dynamic operating conditions.
al
PEC is properly placed into the facility and that workers understand how to utilize the unidirectional airflow to maintain first air
as much as possible given the limitations added from the radiation shielding in the DPA.
AIR-EXCHANGE REQUIREMENTS
For classified areas, adequate HEPA-filtered airflow to the buffer area(s) and ante-room(s) is required to maintain the
ci
appropriate ISO classification during processing activities. Airflow is measured in terms of the number of HEPA-filtered air
changes per hour (ACPH). The ACPH may need to be higher to maintain the required ISO classification and microbial state of
control depending on these factors: the number of personnel permitted to work in the area, the number of particulates that
may be generated from activities and processes in the area, the equipment located in the area, the area pressure, and the effects
of temperature. The summary of ACPH requirements is listed in Table 2.
ffi
A minimum of 30 total HEPA-filtered ACPH must be supplied to ISO Class 7 areas.
• The total HEPA-filtered air change rate must be adequate to maintain ISO Class 7 under dynamic operating conditions
considering factors listed above
• At least 15 ACPH of the total air change rate in a room must come from the HVAC through HEPA filters located in the
ceiling
• The HEPA-filtered air from the PEC, when added to the HVAC-supplied HEPA-filtered air, increases the total HEPA-filtered
O
https://online.uspnf.com/uspnf/document/1_GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US 8/28
www.webofpharma.com
Printed on: Wed Feb 08 2023, 11:06:36 PM(EST) Status: Currently Official on 09-Feb-2023 DocId: GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US
Printed by: Dang Van Vu Official Date: Official as of 01-Dec-2020 Document Type: GENERAL CHAPTER @2023 USPC
Do Not Distribute DOI Ref: rog9b DOI: https://doi.org/10.31003/USPNF_M11915_04_01
9
between the wall and the floor must be sealed to eliminate cracks and crevices where dirt can accumulate. If ceilings consist of
inlaid panels, each panel must be caulked or otherwise sealed and secured to seal them to the support frame.
Walls must be constructed of or covered with a durable material (e.g., epoxy-painted walls or heavy-gauge polymer) and
the integrity of the surface must be maintained. Panels must be joined together and sealed to each other and the support
structure. Floors must include coving to the sidewall or the juncture between the floor and wall must be caulked. Floors must
include coving to the sidewall. Classified areas should minimize dust-collecting overhangs such as utility pipes and ledges such
as windowsills. If overhangs or ledges are present, they must be easily cleanable. The exterior lens surface of ceiling light fixtures
must be smooth, mounted flush, and sealed. Any other penetrations through the ceiling or walls must be sealed.
SRPA
The SRPA and all surfaces (e.g., walls, floors, counters, equipment) within the SRPA must be clean, uncluttered, and dedicated
to sterile radiopharmaceutical processing activities. Surfaces in the SRPA should be smooth, impervious, free from cracks and
crevices, and non-shedding, so they can be easily cleaned and disinfected, and to minimize spaces in which microorganisms
and other contaminants can accumulate. Surfaces should be resistant to damage by cleaning agents, disinfectants, and tools
used to clean. Dust-collecting overhangs such as utility pipes and ledges such as windowsills should be minimized. If overhangs
or ledges are present, they must be easily cleanable.
al
closed system of soap (i.e., non-refillable) to minimize the risk of extrinsic contamination. In facilities with an ante-room and
buffer area, the sink used for hand hygiene may be placed either inside or outside of the ante-room. If the sink is located outside
of the ante-room, it must be located in a clean space to minimize the risk of bringing in contaminants into the ante-room. If
the sink is located inside the ante-room, it may be placed on either the clean side or the less-clean side of the ante-room.
[NOTE—The order of hand washing and garbing would depend on the placement of the sink (see 4.5 Hand Hygiene and Garbing
ci
for Buffer Areas and Segregated Radiopharmaceutical Processing Area).] The buffer area must not contain plumbed water sources
[e.g., sink(s), eyewash(es), shower(s), or floor drain(s)]. The ante-room must not contain floor drain(s). If installed, sprinkler
systems in classified areas should be recessed and covered, and should be easily cleanable. In a facility with an SRPA design, the
sink must be accessible but located at least 1 m from the PEC and generators, if present. The sink must not be located inside
the perimeter of the SRPA.
ffi
5.4 Placement and Movement of Materials
Only furniture, equipment, and other materials necessary are permitted in the classified area or SRPA and they should be
low-shedding and easily cleaned and disinfected. Their number, design, location, and manner of installation must not adversely
impact environmental air quality and must promote effective cleaning and disinfecting. No shipping carton(s) or other
O
https://online.uspnf.com/uspnf/document/1_GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US 9/28
www.webofpharma.com
Printed on: Wed Feb 08 2023, 11:06:36 PM(EST) Status: Currently Official on 09-Feb-2023 DocId: GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US
Printed by: Dang Van Vu Official Date: Official as of 01-Dec-2020 Document Type: GENERAL CHAPTER @2023 USPC
Do Not Distribute DOI Ref: rog9b DOI: https://doi.org/10.31003/USPNF_M11915_04_01
10
be garbed in nonsterile gloves and a low-particulate lab coat for interventions that are outside of the PEC. A failure of the airflow
smoke pattern test requires personnel to garb in accordance with 4.5 Hand Hygiene and Garbing for Buffer Areas and Segregated
Radiopharmaceutical Processing Area for all incursions into the hot-cell.
For situations where the hot-cell is an integrated HEPA filtration system with a clear demarcated area that is a PEC, dynamic
airflow smoke pattern tests must show that the staging of supplies and materials into the demarcated PEC area does not allow
the influx of less than ISO Class 5 quality air into the PEC. Personnel may be garbed in nonsterile gloves and a low-particulate
lab coat for interventions that are outside of the PEC. A failure of the airflow smoke pattern test requires personnel to garb in
accordance with 4.5 Hand Hygiene and Garbing for Buffer Areas and Segregated Radiopharmaceutical Processing Area for all
incursions into the PEC.
Since other hot-cell/PEC configurations and technologies may exist, verification (either by airflow smoke pattern tests or
other manufacturer specified methods) must ensure, upon each certification, that the staging of materials and supplies does
not allow for the intrusion of less than ISO Class 5 air into the designated ISO Class 5 space. A failure of the airflow smoke
pattern test requires personnel to garb in accordance with 4.5 Hand Hygiene and Garbing for Buffer Areas and Segregated
Radiopharmaceutical Processing Area for all incursions into the hot-cell.
al
that ensures that both doors cannot be open at the same time. There may be both positive and negative air pressure within
the facility; positive pressure to minimize the potential of microbial contamination in sterile drug preparation areas, and negative
pressure to minimize potential radioactive contamination from volatile or airborne radiopharmaceuticals. Positive pressure
environments must have a minimum differential positive pressure of 0.02-inch water column between each ISO-classified area
(e.g., between the buffer area and ante-room). The pressure differential between the ante-room and the unclassified area must
ci
be no less than a positive 0.02-inch water column. Refer to the RAM license for negative pressure requirements. For preparation
of sterile radiopharmaceuticals, consideration of both concerns could be addressed as follows:
1. Buffer area, if present, must be positive pressure compared to the ante-room
2. Ante-room, if present, must be positive pressure compared to unclassified portions of the restricted area
3. Restricted area, in the presence of volatile or airborne radiopharmaceuticals, must be negative pressure compared to the
ffi
unrestricted area
4. SRPA must be negative pressure compared to unrestricted areas in the presence of volatile or airborne
radiopharmaceuticals (e.g., I-131 sodium iodide and Xenon).
Various environmental controls for various preparation scenarios (see Table 7 for maximum BUDs for differing environments)
are described in the following sections. Table 1 details the limits for particle counts for each specific ISO classification.
O
SRPA WITH VERTICAL FLOW ISO CLASS 5 PEC(S) FOR RADIOPHARMACEUTICAL PREPARATIONS
An SRPA with vertical ISO Class 5 PECs must meet the following requirements:
• Area surrounding the PEC may be ambient (unclassified) atmosphere
• Area must be clean, uncluttered, and dedicated to the processing of radiopharmaceuticals
• Appropriate for preparation, preparation with minor deviations, repackaging, and dispensing of radiopharmaceuticals
An area that meets ISO Class 8 total airborne particle-count specifications may be used to store and elute non-direct infusion
radionuclide generators (e.g., Tc-99m).
https://online.uspnf.com/uspnf/document/1_GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US 10/28
www.webofpharma.com
Printed on: Wed Feb 08 2023, 11:06:36 PM(EST) Status: Currently Official on 09-Feb-2023 DocId: GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US
Printed by: Dang Van Vu Official Date: Official as of 01-Dec-2020 Document Type: GENERAL CHAPTER @2023 USPC
Do Not Distribute DOI Ref: rog9b DOI: https://doi.org/10.31003/USPNF_M11915_04_01
11
AN ISO CLASS 8 BUFFER AREA WITH VERTICAL FLOW ISO CLASS 5 PEC(S) WITH AN ADJACENT ISO CLASS 8 ANTE-ROOM
This environment is appropriate for all activities listed in SRPA with Vertical Flow ISO Class 5 PEC(s) for Radiopharmaceutical
Preparations.
AN ISO CLASS 7 BUFFER AREA WITH VERTICAL FLOW ISO CLASS 5 PEC(S) WITH AN ADJACENT ISO CLASS 8 OR BETTER
ANTE-ROOM
This environment is appropriate for all activities listed in An ISO Class 8 Buffer Area with Vertical Flow ISO Class 5 PEC(s) with
an Adjacent ISO Class 8 Ante-Room and sterile compounding.
HOT-CELL
This environment is appropriate for all activities listed in SRPA with Vertical Flow ISO Class 5 PEC(s) for Radiopharmaceutical
Preparations.
al
that air consistently flows from most to least clean areas, and that the appropriate quality of air is maintained under dynamic
operating conditions.
• HEPA filter integrity testing: HEPA filters must be leak tested after installation and as part of recertification.
• Total particle counts testing: Conducted under dynamic operating conditions using calibrated electronic equipment.
• Smoke visualization studies: Performed under either simulated or dynamic operating conditions to demonstrate
ci
unidirectional airflow and sweeping action over and away from the preparation(s).
In cases where technologies exist for hot-cell and PEC configurations that are not consistent for certification by the current
CETA standards, other equivalent means for certifying the PEC may be performed and documented per facility SOPs. In this
case, the PEC must maintain the environmental equivalent for total particle counts and the protection of the ISO Class 5 area
from intrusions of lesser controlled air.
ffi
DAILY MONITORING OF ENVIRONMENT
The temperature and humidity must be monitored in the SRPA or area containing a hot-cell, and if in a classified area the
pressure must monitored, each day that preparations are made, either manually or by a continuous recording device. These
include:
O
An effective air and surface monitoring program provides information on the environmental quality of the classified areas
where sterile radiopharmaceuticals are processed. The program identifies environmental quality trends over time, potential
routes of microbiological contamination, and allows for implementation of corrective actions to prevent microbiological
contamination of the radiopharmaceuticals. Facilities must develop and implement written air and surface monitoring
procedures for all sterile radiopharmaceutical classified areas. Air and surface monitoring results and the corrective actions must
be documented, and records must be readily retrievable as required by jurisdictional laws and regulations.
https://online.uspnf.com/uspnf/document/1_GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US 11/28
www.webofpharma.com
Printed on: Wed Feb 08 2023, 11:06:36 PM(EST) Status: Currently Official on 09-Feb-2023 DocId: GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US
Printed by: Dang Van Vu Official Date: Official as of 01-Dec-2020 Document Type: GENERAL CHAPTER @2023 USPC
Do Not Distribute DOI Ref: rog9b DOI: https://doi.org/10.31003/USPNF_M11915_04_01
12
routes of contamination, and the adequacy of cleaning and disinfection techniques and agents specified in the facility SOPs.
Regular review of the sampling data must be performed to detect trends such as elevated levels of microbial bioburden, elevated
levels of nonviable particulates, or other adverse changes within the environment. Evaluating results collected over a period of
time can be useful in identifying trends or determining that a significant change has occurred, even when the results fall within
the specified limits.
In addition, results must be reviewed in conjunction with personnel data (i.e., training records, visual observations,
competency assessments) to assess the state of control and to identify potential risks of contamination. Prompt corrective action
in response to any adverse findings is required to maintain the necessary environmental quality for handling sterile
radiopharmaceutical. Data must also be reviewed following corrective actions to confirm that the actions taken have been
effective in achieving the required air and surface quality levels (see Table 3 and Table 4).
Air and surface sampling must be conducted during actual or simulated dynamic operating conditions to confirm that the
required environmental quality in classified areas is maintained. Due to radiation exposure concerns for the workers involved,
it is permissible for sampling to be carried out at the conclusion of sterile radiopharmaceutical processing but prior to cleaning
and disinfecting the surface area. In this case, simulated tasks that are reflective of the routine aseptic activities are performed.
In addition to the specific sampling frequencies described in this section, sampling must be performed in any of the following
circumstances:
• In conjunction with the certification of new facilities and equipment
• After any modification of facilities or equipment
• In response to identified problems (e.g., positive growth in sterility tests of compounded radiopharmaceuticals)
• In response to identified trends (e.g., repeated positive gloved fingertip sampling results or failed media-fill testing
involving more than one operator where a review of the operator technique shows no reasonable flaws in process; repeated
observations of air or surface contamination)
al
• In response to changes that could impact the controlled area environments (e.g., significant change in cleaning process
or the agents involved)
To obtain an air and surface sample that is representative of the typical aseptic operating conditions at the facility, air and
surface sampling must be conducted under dynamic or simulated dynamic operating conditions in all PECs and classified areas.
If conducted during actual sterile processing, the monitoring program must be designed and conducted in a manner that
environment.
ci
minimizes the chance that the sampling itself will contribute to contamination of the sterile radiopharmaceutical(s) or the
The air and surface monitoring program must be clearly described in the established SOPs of the facility and must include a
diagram of the sampling locations, SOPs for collecting samples, frequency of sampling, size of samples (e.g., surface area,
volume of air), time of day of sampling in relation to activities in the classified areas, and action levels that will trigger corrective
ffi
action. The locations of sampling should be carefully selected based on their relationship to the activities performed in the area.
It is important to obtain samples from locations that pose the highest possible contamination risk to the sterile
radiopharmaceuticals involved with the operation’s processes and that are likely to be representative of the conditions
throughout the area.
Evaluating results collected over a period of time can be useful in identifying trends or determining that a significant change
has occurred, even when the results fall within the specified limits.
O
It is important that personnel who operate the equipment be trained in the proper operation of the air and surface sampling
equipment to ensure accurate and reproducible sampling. All air sampling devices must be serviced and calibrated as
recommended by the manufacturer.
https://online.uspnf.com/uspnf/document/1_GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US 12/28
www.webofpharma.com
Printed on: Wed Feb 08 2023, 11:06:36 PM(EST) Status: Currently Official on 09-Feb-2023 DocId: GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US
Printed by: Dang Van Vu Official Date: Official as of 01-Dec-2020 Document Type: GENERAL CHAPTER @2023 USPC
Do Not Distribute DOI Ref: rog9b DOI: https://doi.org/10.31003/USPNF_M11915_04_01
13
20°–25° for no less than 5 days. Count the total number of discrete colonies of microorganisms on each sample, and record
these results as cfu per sample.
Record the results of the sampling on an environmental sampling form based on sample type (i.e., viable air) and include
the sample location, and sample date.
A general microbiological growth medium that supports the growth of bacteria and fungi must be used (e.g., TSA medium).
CoA(s) from the manufacturer must verify that the medium meets the expected growth promotion, pH, and sterilization
requirements. Samples must be incubated in a temperature monitored incubator with a calibrated measuring device. The
incubator temperature must be monitored during incubation, either manually or by a continuous recording device, and the
results must be reviewed and documented. Incubators used for microbiological testing must be placed in a location outside of
any classified area or SRPA and kept away from areas where compounding or sterile processing activities are carried out. All
sampling activities must be performed by trained individuals.
al
plan must be documented. If levels measured during viable air sampling exceed the levels in Table 3, an attempt must be made
to identify any microorganism recovered to the genus level (see Microbial Characterization, Identification, and Strain Typing
á1113ñ) with the assistance of a qualified individual (e.g., microbiologist or industrial hygienist).
ISO Class
5
ci Air Sampling Action Levels
[cfu/m3 (1000 L) of air per plate]
>1
7 >10
ffi
8 >100
a Adapted from Guidance for Industry: Sterile Drug Products Produced by Aseptic Processing—Current Good Manufacturing Practice. US Department of Health and Human
Services, Food and Drug Administration (FDA), September 2004.
Surface sampling is an important component of the maintenance of a suitably controlled environment for sterile
radiopharmaceutical processing, especially because transfer of microbial contamination from improperly disinfected work
surfaces (e.g., via inadvertent touch contact by personnel) is a potential source of contamination of the radiopharmaceutical(s).
Surface sampling is useful for evaluating facility cleaning and material handling procedures, work surface cleaning and
disinfecting procedures, and personnel competency in work practices such as proper cleaning and disinfection. All sampling
sites and procedures must be described in the facility’s SOP.
SAMPLING PROCEDURES
Surface sampling devices (e.g., plates, paddles, or slides) containing microbial growth media must be used for sampling flat
surfaces. CoAs from the manufacturer must verify that the media meet the expected growth promotion, pH, and sterilization
requirements. Surface sampling devices must contain general microbial growth media (e.g., TSA) supplemented with
neutralizing additives (e.g., lecithin and polysorbate 80) to neutralize the effects of any residual disinfecting agents. If used,
contact plates must have a raised convex surface. Sterile swabs wetted with sterile water or a sterile neutralizing buffer may be
https://online.uspnf.com/uspnf/document/1_GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US 13/28
www.webofpharma.com
Printed on: Wed Feb 08 2023, 11:06:36 PM(EST) Status: Currently Official on 09-Feb-2023 DocId: GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US
Printed by: Dang Van Vu Official Date: Official as of 01-Dec-2020 Document Type: GENERAL CHAPTER @2023 USPC
Do Not Distribute DOI Ref: rog9b DOI: https://doi.org/10.31003/USPNF_M11915_04_01
14
used when sampling irregular surfaces and difficult-to-reach locations, such as crevices, corners, and spaces between surfaces.
After sampling, the sampled area must be thoroughly cleaned and disinfected.
Use the following procedures for surface sampling on flat surfaces:
1. Remove the cover from the surface sampling device. Firmly press, using a rolling motion, if possible, the media surface
onto the surface to be sampled. The surface sampling device will leave a residue of growth medium on the sample site.
After sampling, use sterile 70% IPA to remove residue. Cover each surface sampling device.
2. If using plates, invert the plates.
3. Incubate the surface sampling devices at 30°–35° for no less than 48 hours. Examine for growth. Record the total number
of discrete colonies of microorganisms on each media device as cfu/sample on an environmental sampling form based
on sample type (i.e., surface). Include sample location and date.
4. Incubate the device at 20°–25° for no less than 5 additional days. Examine the media plates for growth. Record the total
number of discrete colonies of microorganisms (cfu/sample) on the environmental sampling record based on sample
type (i.e., surface). Include sample location and date.
Alternatively, to shorten the overall incubation period, two samples may be collected for each sample location.
1. Both samples could be TSA or one sample could be TSA and the other fungal media (e.g., MEA or SDA).
2. Incubate each sample in a separate incubator. Incubate one sample at 30°–35° for no less than 48 hours, and incubate
the other sample at 20°–25° for no less than 5 days.
3. If fungal media are used as one of the samples, incubate the fungal media sample at 20°–25° for no less than 5 days.
4. Count the total number of discrete colonies of microorganisms on each sample, and record these results as cfu per sample.
Record the results of the sampling.
5. Record the results of the sampling.
al
DATA EVALUATION AND ACTION LEVELS
Evaluate cfu counts against the action levels in Table 4 and examine counts in relation to previous data to identify adverse
results or trends. If two devices were collected at a single location, all recovered growth on each must be documented and
ci
action levels are applied to each piece of media individually (i.e., results from each sampling device must be compared to the
action level for the area). If levels measured during surface sampling exceed the levels in Table 4 for the ISO classification levels
of the area sampled, the cause must be investigated and corrective action must be taken. Data collected in response to corrective
actions must be reviewed to confirm that the actions taken have been effective. The corrective action plan must be dependent
on the cfu count and the microorganism recovered. Examples of corrective action include process or facility improvements,
personnel training, cleaning and disinfecting, or HEPA filter replacement and/or repair, or reducing the BUD of the
ffi
radiopharmaceutical(s) during investigation and while carrying out the corrective action plan. The extent of the investigation
should be consistent with the deviation and should include an evaluation of trends. The corrective action plan must be
documented. If levels measured during surface sampling exceed the levels in Table 4, an attempt must be made to identify any
microorganism recovered to the genus level (see á1113ñ) with the assistance of a qualified individual (e.g., microbiologist or
industrial hygienist).
O
7 >5
8 >50
Cleaning and disinfecting are important because surfaces in classified areas and SRPAs are a potential source of microbial
contamination of sterile radiopharmaceuticals. The process of cleaning involves removing organic and inorganic residues from
surfaces, usually with a manual or mechanical process and a cleaning agent. The process of disinfecting involves destruction of
microorganisms, usually with a chemical or physical agent. Surfaces must be cleaned prior to being disinfected unless an
Environmental Protection Agency (EPA)-registered (or equivalent) one-step disinfectant cleaner is used to accomplish both the
cleaning and disinfection in one step. After cleaning and disinfecting or the application of a one-step disinfectant cleaner in a
PEC, apply sterile 70% IPA to remove any residue.
Cleaning and disinfecting surfaces should occur at the minimum frequencies specified in Table 5 or if activities are not
performed daily, cleaning and disinfecting must be completed before initiating activities. The act of reducing or removing
radioactivity (radioactive decontamination) from an object or surface must be balanced with the risk of spreading radioactive
contamination. At times the best approach may be to shield the area until the radiation exposure levels are lower. This balance
must be specified in SOPs (e.g., trigger levels for safe cleaning). The PEC should be checked for radioactive contamination prior
to cleaning and disinfecting to prevent spreading radioactive contamination in the PEC.
All cleaning and disinfecting activities must be performed by trained and appropriately garbed personnel using
facility-approved agents and procedures that must be described in written SOPs. Cleaning must be performed in the direction
of most to least clean areas. The frequency, method(s), and location(s) of cleaning, disinfecting, and sporicidal agent use must
be established in written SOPs, in accordance with the manufacturer’s instructions when available, or based on sound
microbiological cleaning techniques when unavailable, and must be followed by all cleaning personnel. The manufacturer’s
https://online.uspnf.com/uspnf/document/1_GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US 14/28
www.webofpharma.com
Printed on: Wed Feb 08 2023, 11:06:36 PM(EST) Status: Currently Official on 09-Feb-2023 DocId: GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US
Printed by: Dang Van Vu Official Date: Official as of 01-Dec-2020 Document Type: GENERAL CHAPTER @2023 USPC
Do Not Distribute DOI Ref: rog9b DOI: https://doi.org/10.31003/USPNF_M11915_04_01
15
direction or published data for the minimum contact time must be followed for the cleaning, disinfecting, and sporicidal agents
used. When sterile 70% IPA is used, it must be allowed to dry. All cleaning, disinfecting, and application of sporicidal agents
must be documented according to facility SOPs.
Table 5. Minimum Frequency for Cleaning and Disinfecting Surfaces in Classified Areas and within the Perimeter of the SRPA
Site Cleaning Disinfectinga Applying Sporicidal
Prior to performing sterile processing
of radiopharmaceuticals on each day
that activities are carried out, the
walls, bars, torso shield and any ex- Following cleaning on each day that
posed surface of equipment inside the activities are carried out, exposed sur-
PEC must be cleaned to the extent faces of the equipment should be dis-
possible as specified by the equip- infected to the extent possible as
ment manufacturer or the assessment specified by the equipment manufac-
of a qualified individual (e.g., micro- turer or the assessment of a qualified
biologist or industrial hygienist). Ra- individual (e.g., microbiologist or in-
dioactive contamination may be dustrial hygienist).
shielded with appropriate temporary When used, remove low-lint absorb-
material, providing the material is ent pads and survey the PEC for radi-
covered with low-lint absorbent pads oactive contamination prior to disin-
PEC(s) and equipment inside the or has equivalent low-shedding prop- fecting. Replace with new pads after
PEC(s) erties. disinfecting or as required after spills. Monthly
al
ent on design, equipment, and shield-
ing present) Daily Daily Monthly
Wall(s),
door(s),
door frame(s), and other fixtures Monthly Monthly Monthly
a Many disinfectants registered with the EPA are one-step cleaning and disinfecting agents, which means that the disinfectant has been formulated to be effective
in the presence of light to moderate soiling without a separate cleaning step. Cleaning and disinfecting must be balanced with the risk of spreading radiation
contamination. The best approach may be to shield the area until the radiation exposure levels are lower.
Disinfecting agent A chemical or physical agent used on inanimate surfaces and objects to destroy fungi, viruses, and bacteria.
A chemical or physical agent that destroys bacterial and fungal spores when used in sufficient concentration for a specified contact
Sporicidal agent time. It is expected to kill all vegetative microorganisms.
https://online.uspnf.com/uspnf/document/1_GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US 15/28
www.webofpharma.com
Printed on: Wed Feb 08 2023, 11:06:36 PM(EST) Status: Currently Official on 09-Feb-2023 DocId: GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US
Printed by: Dang Van Vu Official Date: Official as of 01-Dec-2020 Document Type: GENERAL CHAPTER @2023 USPC
Do Not Distribute DOI Ref: rog9b DOI: https://doi.org/10.31003/USPNF_M11915_04_01
16
al
4. Apply sterile 70% IPA
5. Allow the surface to dry completely before beginning activities.
6. The PEC must be wiped with a sporicidal agent at least monthly.
opened and appropriately labeled outside of the ISO Class 5 environment and placed in disinfected shielding, immediately prior
to the forthcoming dispensing cycle.
8. ASSIGNING BUD
BUDs are based on the risk of microbial contamination with the assumption that the radiopharmaceutical(s) should remain
chemically and physically stable, and its container–closure system should maintain its integrity for the duration of the BUD
(Table 7). The time starts at the moment of the first sterile vial puncture or exposure of a critical site (e.g., syringe tip, needle
hub, or needle) to ambient air, whichever is first. The BUDs stated in Table 7 are maximum values in the absence of sterility
1 Centers for Disease Control and Prevention. Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008.
https://online.uspnf.com/uspnf/document/1_GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US 16/28
www.webofpharma.com
Printed on: Wed Feb 08 2023, 11:06:36 PM(EST) Status: Currently Official on 09-Feb-2023 DocId: GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US
Printed by: Dang Van Vu Official Date: Official as of 01-Dec-2020 Document Type: GENERAL CHAPTER @2023 USPC
Do Not Distribute DOI Ref: rog9b DOI: https://doi.org/10.31003/USPNF_M11915_04_01
17
testing, and the assigned BUD may be shorter for a variety of reasons discussed below. The individual responsible for the
manipulation assigns the BUD based on established testing data, either performed in-house or obtained from peer-reviewed
literature.
BUD
Manipulation PEC SEC (hours)
Immediate use — — 1
al
Dispensing, repackaging, preparation,
and preparation with minor devia- ISO Class 8 or better buffer area with
tions ISO Class 5 ISO Class 8 or better ante-room 24
Radiolabeled blood components (e.g., ISO Class 7 or better buffer area with
radiolabeled leukocytes) ISO Class 5 BSC ISO Class 8 or better ante-room 6 h after the blood sample is obtained
For compounded preparations (sterile and nonsterile), the BUD is also dependent on maintenance of appropriate quality
and purity, including radiochemical purity, radionuclidic purity, and other applicable parameters as specified in individual
monographs or as clinically appropriate.
For preparations with minor deviations involving conventionally manufactured kits (sterile and nonsterile), the kit may state
or suggest a use-by time in the package insert. For certain radiopharmaceuticals transportation time, radionuclide availability,
and other factors may necessitate extending manufacturer-stated/suggested use-by time to meet patient needs. Assigning a
BUD longer than the manufacturer-stated/suggested use-by time interval must be supported by evidence of the maintenance
of appropriate quality and purity, including radiochemical purity and radionuclidic purity as specified in individual monographs,
and other applicable parameters as clinically appropriate.
Assignment of a BUD for a radiopharmaceutical(s) must consider several factors, as applicable. Issues of concern include, but
are not limited to, the following:
• Sterility: Maintenance of sterility is a major concern for any sterile preparation or product. Good aseptic handling practices
in an appropriate environmentally-controlled area are the most critical factors in ensuring sterility. See Table 7 for maximum
BUD. The assigned BUD should not exceed the sterility-related times listed in Table 7, unless a longer time is justified by
Sterility Tests á71ñ.
• Radiochemical purity: Maintenance of radiochemical purity is affected by a variety of factors including, but not limited to,
storage temperature, quantity of radioactivity, radioactivity concentration, presence or absence of antioxidants or other
stabilizing agents, and container type (e.g., glass vial vs. plastic syringe). The assigned BUD must be based on stability
studies in which these variables are controlled and are representative of the conditions of actual use. For factors that allow a
range of values (e.g., storage temperature, quantity of radioactivity, radioactivity concentration), studies should be
conducted at the extremes of the ranges.
• Radionuclidic purity: Because radionuclidic impurities may decay away more slowly than the primary radionuclide, the
radionuclidic purity may decrease over time. For example, the ratio of Mo-99 (half-life of about 66 hours) to Tc-99m
(half-life of about 6 hours) continuously increases over time. USP monographs for Tc-99m radiopharmaceuticals require
that the radionuclidic impurity Mo-99 not exceed 0.15 μCi Mo-99 per mCi Tc-99m at the time of administration.
Calculation of radionuclidic purity at future times is necessary to ensure compliance throughout the assigned BUD.
https://online.uspnf.com/uspnf/document/1_GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US 17/28
www.webofpharma.com
Printed on: Wed Feb 08 2023, 11:06:36 PM(EST) Status: Currently Official on 09-Feb-2023 DocId: GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US
Printed by: Dang Van Vu Official Date: Official as of 01-Dec-2020 Document Type: GENERAL CHAPTER @2023 USPC
Do Not Distribute DOI Ref: rog9b DOI: https://doi.org/10.31003/USPNF_M11915_04_01
18
• Age of generator eluate: As a generator eluate decays, the desired daughter radionuclide decays to form other nuclides
and potential radiolytic products, which may interfere with radiolabeling of kits. For example, Tc-99m undergoes decay
to Tc-99. More importantly, increasing amounts of peroxides formed as radiation interacts with water molecules. Increased
amounts of Tc-99 and peroxides can interfere with the radiolabeling of many kits. Extension of the BUD for Tc-99m
pertechnetate intended for radiolabeling of kits must take into account the build-up of Tc-99 and peroxides over time.
• Number of particles: For radiolabeled particulates, the number of particles per unit radioactivity increases over time as the
radionuclide decays. For example, the BUD for Tc-99m albumin aggregated [macroaggregated albumin (MAA)] must take
into account the increasing ratio over time of the number of particles per unit radioactivity. For example, if an MAA kit is
prepared such that the radioactive patient dose is 200,000 particles at the time of calibration, the same patient dose will
contain 700,000 particles at 10.85 hours after calibration. Calculation of the number of MAA particles in the patient dose
is necessary to ensure compliance with the prescribed particle range throughout the assigned BUD.
• Specific activity: For some receptor-based radiopharmaceuticals, the mass quantity may influence uptake (i.e., too much
mass may result in saturation of receptor sites and reduce target uptake of the radiopharmaceutical). As radioactivity decays
over time, specific activity decreases resulting in more mass per unit radioactivity. In such situations, the assigned BUD
must ensure that the patient dose contains no more than the specified maximum mass.
• Container type: Because radiochemical stability or other quality attributes of a radiopharmaceutical may be affected by its
container characteristics, the BUD for a radiopharmaceutical dose dispensed in a plastic syringe may be different than the
BUD of that same radiopharmaceutical maintained in a glass vial. The assigned BUD must be determined in the proper
storage container.
• Cell viability: The viability of radiolabeled blood cells (e.g., leukocytes) decreases over time, and may also be affected by
other factors such as the suspending medium, temperature, and agitation. The assigned BUD should be as short as
circumstances reasonably allow so as to maximize cell viability.
al
• In the case of manufactured radiopharmaceuticals that are distributed to nuclear pharmacies or other healthcare facilities
for terminal distribution/dispensing, the assigned BUD of the dispensed dose cannot exceed the expiration date/time of
the manufactured radiopharmaceutical(s).
• In the case of radiopharmaceuticals prepared from kits, the BUD of a dispensed dose cannot exceed the assigned BUD of
the finished kit preparation.
ci
• A radiopharmaceutical may not exceed the shortest BUD of any of its components.
The facility must have policies and SOPs appropriate to the assignment of BUD and maintain documentation of applicable
study results and calculations. Studies of radiolabeling efficiency and radiochemical stability should employ quality control (QC)
testing methods described in the manufacturer’s package insert, USP monographs and general chapters, or other equivalent
testing methods and be sufficiently rigorous to allow statistical confidence in the results.
ffi
The facility must have SOPs to collect and evaluate complaints associated with the use of radiopharmaceuticals having
assigned BUDs. Policies and SOPs should also be in place to reevaluate the assigned BUD based on complaints, which may
include repeating studies and/or performing additional studies on radiolabeling efficiency and/or radiochemical stability.
9. DOCUMENTATION
O
Applicable records (hard-copy or electronic), including policies and SOPs, must be maintained for all activities involved in
repackaging, preparing, preparing with minor deviations, compounding, and dispensing radiopharmaceuticals. Such records
include, but are not limited to:
• Personnel training and testing, including visual assessment of aseptic technique competency, validation, garbing, hand
hygiene, equipment/environment cleaning and disinfecting, gloved fingertip and thumb sampling, and media fill
evaluation initially and follow up testing at specified intervals.
• Testing and monitoring of environmental controls, including ISO classification, ACPH, pressure differentials, temperature,
humidity and viable air/surface and total airborne particle test results
• Equipment maintenance and cleaning/disinfecting
• End product radiochemical purity and other testing, as applicable, results of preparations, preparations with minor
deviations, and compounded preparations
• Master Formulation Record (MFR) for preparation with minor deviation(s) and compounding
• Validation of stability testing to support the assigned BUD from SOPs by the compounder or derived from accepted
literature
• Investigations and corrective actions and tracking of events to closure.
https://online.uspnf.com/uspnf/document/1_GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US 18/28
www.webofpharma.com
Printed on: Wed Feb 08 2023, 11:06:36 PM(EST) Status: Currently Official on 09-Feb-2023 DocId: GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US
Printed by: Dang Van Vu Official Date: Official as of 01-Dec-2020 Document Type: GENERAL CHAPTER @2023 USPC
Do Not Distribute DOI Ref: rog9b DOI: https://doi.org/10.31003/USPNF_M11915_04_01
19
al
• Date and time of preparation
• Assigned internal identification number (e.g., lot number)
• Unique reference [e.g., prescription, order number(s)]
• Assigned BUD and storage requirements ci
• Documentation of QC results
10. PREPARATION
The individual responsible for preparing the radiopharmaceutical(s) must ensure that the final preparation complies with
ffi
quality and purity specifications throughout the assigned BUD. This includes, as appropriate for the preparation, radionuclidic
purity, radiochemical purity, chemical purity, and physical and chemical properties.
NONSTERILE PREPARATIONS
For nonsterile preparations, follow manufacturer preparation instructions (e.g., I-131 NaI capsules or solution), taking into
account appropriate radiation safety considerations and environmental controls, if applicable (e.g., negative air pressure area,
chemical fume hood, activated charcoal filters when handling a potentially volatile radionuclide). The area should be suitably
cleaned and uncluttered to ensure the overall integrity and quality of the prepared radiopharmaceutical(s). There should be a
documented process for activities (e.g., cleaning) between the preparation cycles of different nonsterile products, to decrease
the likelihood of contamination from other prepared products.
STERILE PREPARATIONS
For sterile preparations (including intravascular devices), follow manufacturer preparation instructions, taking into account
appropriate radiation safety considerations, appropriate environmental controls, and aseptic handling practices to maintain
sterility. The minimum environmental standard for the preparation of sterile radiopharmaceuticals beyond immediate-use is
within an ISO Classified area or device (see Table 7). Refer to 5. Facilities and Environmental Controls and Table 7 on the location
of the PEC and the assignment of the BUD.
https://online.uspnf.com/uspnf/document/1_GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US 19/28
www.webofpharma.com
Printed on: Wed Feb 08 2023, 11:06:36 PM(EST) Status: Currently Official on 09-Feb-2023 DocId: GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US
Printed by: Dang Van Vu Official Date: Official as of 01-Dec-2020 Document Type: GENERAL CHAPTER @2023 USPC
Do Not Distribute DOI Ref: rog9b DOI: https://doi.org/10.31003/USPNF_M11915_04_01
20
al
SOPs must be in place to include certification that the SEC meets conditions of air quality at maximum occupancy under
dynamic operating conditions.
• One radiolabeling procedure per PEC at a time. Blood products from more than one patient must never be manipulated
at the same workstation at the same time. Each area should have dedicated supplies, equipment (including dose calibrator),
and waste disposal to eliminate sharing of these items or overlap in pathways.
ci
• Thorough cleaning and disinfection of the ISO Class 5 BSC and all reusable equipment within, prior to starting another
blood component radiolabeling procedure.
• If a dedicated dose calibrator is not available, then a means of preventing the blood container(s) from contaminating the
dose calibrator must be used or the dose calibrator dipper and liner must be cleaned and disinfected following the
radioassay.
ffi
• Centrifuge should be located within the ISO Class 7 buffer area that is dedicated for blood component radiolabeling
processes.
• Dedicated (per each radiolabeling procedure) consumable products (e.g., 0.9% sodium chloride injection, diluent, tubes,
syringes, and other supplies) necessary for each individual patient radiolabeling procedure.
• All tubes and syringes in contact with the patient’s blood components must be clearly labeled with the patient’s name
and at least one additional identifier (e.g., date of birth, medical record number, barcode).
O
https://online.uspnf.com/uspnf/document/1_GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US 20/28
www.webofpharma.com
Printed on: Wed Feb 08 2023, 11:06:36 PM(EST) Status: Currently Official on 09-Feb-2023 DocId: GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US
Printed by: Dang Van Vu Official Date: Official as of 01-Dec-2020 Document Type: GENERAL CHAPTER @2023 USPC
Do Not Distribute DOI Ref: rog9b DOI: https://doi.org/10.31003/USPNF_M11915_04_01
21
• The start time of the preparation must begin with the initial container puncture or the exposure of a critical site (e.g.,
syringe tip, needle hub or needle) to ambient air, whichever is first.
• BUD of 1 hour (see Table 7).
11. COMPOUNDING
Each compounding activity must be based on a pre-established written procedure and must include maintenance of
compounding records. The compounding record must provide traceability (see 9. Documentation).
All sterile compounding, using aseptic technique, must be performed in an ISO 5 PEC. Refer to 5.7 Environmental Controls
and Table 7 for further clarification on the location of the PEC and the applicability of the radiopharmaceutical BUD.
Compounding must not be performed for any radiopharmaceutical(s) that has been withdrawn from the market because of
safety or lack of effectiveness, unless part of an institutional review board approved investigational study. Radiopharmaceuticals
that are essentially copies of marketed FDA-approved radiopharmaceuticals must not be compounded unless there is a change
that produces a clinical difference for an identified individual patient, as determined by a prescriber.
al
administration (e.g., Tc-99m sulfur colloid in eggs). Areas designated for nonsterile compounding must be cleaned and
uncluttered and separated from areas designated for sterile radiopharmaceuticals. Compounding should take into account RAM
licensing requirements for appropriate radiation safety considerations and utilize appropriate environmental controls, if
applicable (e.g., chemical fume hood, activated charcoal filters when handling potentially volatile radionuclides). The placement
of equipment and materials must take into account a design that prevents cross-contamination.
ci
When feasible, disposable material should be used to reduce the chance of cross-contamination. Each compound must have a
unique MFR (see 9.1 Master Formulation Record). The preparation information is documented on a compounding record (see
9.2 Records for Preparation with Minor Deviations/Compounding). The MFR details the selection of all components. The ingredients
must be obtained from sources in this preferential order: FDA-approved product; FDA-registered facility; and lastly, if the
ingredients for the compound are not available from either of these two sources, the MFR must detail the selection of a material
that is suitable for the intended use. The MFR must establish the identity, strength, purity, and quality of the ingredients by
ffi
validated means (e.g., CoA). Requirements for nonsterile oral meal components are limited to common food grade description
and are not required to establish identity by validated means.
A BUD for the compounded radiopharmaceutical must be validated, taking into account the stability of the ingredients, any
intermediate containers, the final container, and the storage conditions. A BUD cannot be extended past the labeled expiration
date of any component in the compound. If the compounded radiopharmaceutical(s) includes components from other
preparations or preparations with minor deviations, the BUD of the final compounded radiopharmaceutical must not exceed
O
https://online.uspnf.com/uspnf/document/1_GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US 21/28
www.webofpharma.com
Printed on: Wed Feb 08 2023, 11:06:36 PM(EST) Status: Currently Official on 09-Feb-2023 DocId: GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US
Printed by: Dang Van Vu Official Date: Official as of 01-Dec-2020 Document Type: GENERAL CHAPTER @2023 USPC
Do Not Distribute DOI Ref: rog9b DOI: https://doi.org/10.31003/USPNF_M11915_04_01
22
If compounding involves a bulk drug substance, the radiopharmaceutical must comply with standards of an applicable USP
or NF monograph, if one exists, or be a component of an approved drug product. For this chapter, a bulk drug substance
includes a radionuclide, a ligand, or other substance, such as a precursor that becomes an active ingredient in the final
radiopharmaceutical. Each bulk drug substance should be manufactured by drug establishments registered with FDA and be
accompanied by a valid CoA or equivalent testing procedures.
If compounding involves excipients or other inactive ingredients, the excipients or other inactive ingredients must comply
with standards of an applicable USP or NF monograph, if one exists. It is also acceptable that any excipients or other inactive
ingredients be approved products, manufactured by a drug establishment registered with the FDA.
12. DISPENSING
al
Except for an unopened manufacturer container, the final dose or ordered amount must be radioassayed (i.e., in a dose
calibrator). The measured activity should be mathematically corrected for radioactive decay to the time of scheduled
administration (calibration time) (refer to 14. Quality Assurance and Quality Control). The activity at calibration time must always
be within federal, state, and local variance limits.
12.2 Labeling
ci
The labeling of radiopharmaceuticals can fall under the jurisdiction of numerous regulatory agencies. Individual boards of
pharmacy and other regulatory bodies may have very specific statutes and/or regulations concerning this process. The
requirements specified in this chapter must be considered the minimum requirements for the labeling of the inner container
ffi
(e.g., syringe, vial) and the outer shielding (e.g., syringe or vial shielding). Therefore, all personnel distributing and/or dispensing
radiopharmaceuticals should verify that any labeling is in compliance with regulatory agencies.
The inner container must be labeled with the following:
• Standard radiation symbol
• The words “Caution—Radioactive Material”
• For all therapeutic and blood-products, the patient name/identifier
O
https://online.uspnf.com/uspnf/document/1_GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US 22/28
www.webofpharma.com
Printed on: Wed Feb 08 2023, 11:06:36 PM(EST) Status: Currently Official on 09-Feb-2023 DocId: GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US
Printed by: Dang Van Vu Official Date: Official as of 01-Dec-2020 Document Type: GENERAL CHAPTER @2023 USPC
Do Not Distribute DOI Ref: rog9b DOI: https://doi.org/10.31003/USPNF_M11915_04_01
23
hours, there could be a sterility concern if not operated properly. Therefore, the following parameters must be considered by
the operator of the system:
• Setup attachment or needle-puncture should be performed in a defined environment
• Aseptic handling in ambient air with a maximum BUD of 10 hours is allowed for these direct infusion systems (see Table 7)
• The 0.9% sodium chloride bag attached to the device may only be punctured once and may be used for no more than
10 hours. The bag must be labeled with the date and time of puncture and the BUD
• Any nonsterile parts of the device that may encounter the septum of the radiopharmaceutical vial must be disinfected
with sterile 70% IPA prior to puncturing the vial with the needle
• The septum of any vial and the ports of any diluent bag must be wiped with sterile 70% IPA prior to puncturing
• When puncturing the vial in ambient air, it must only be punctured once
• If there are problems with the infusion device, no sterile container(s) associated with the system can be repunctured or
transferred to a PEC for further manipulations and the container, with contents, must be discarded
al
13. REPACKAGING
Repackaging refers to the act of removing conventionally manufactured radiopharmaceutical(s) from the container in which
it was distributed by the original manufacturer and placing it into a different container without further manipulation of the
product. Repackaging also includes the act of placing the contents of multiple containers of the same finished drug product
ci
into one container, as long as the container does not include other ingredients. Repackaging may be performed for nonsterile
radiopharmaceuticals (e.g., I-131 sodium iodide oral capsules) and for sterile radiopharmaceuticals (e.g., thallous chloride Tl
201 injection).
Except for unopened manufacturer dosage units (e.g., capsules, Xe-133 vials), the repackaged radiopharmaceutical must be
radioassayed (i.e., in a dose calibrator). The inner container should be labeled with the following:
ffi
• Standard radiation symbol
• The words “Caution—Radioactive Material”
• The radionuclide and chemical form (generic name)
• Radioactivity with units at time of calibration and the calibration time
The outer shielding should be labeled with the following:
O
Quality assurance (QA) is a system of procedures, activities, and oversight that ensures that radiopharmaceutical processing
consistently meets quality standards (see Quality Assurance in Pharmaceutical Compounding á1163ñ). Quality control (QC) is the
sampling, testing, and documentation of results that, taken together, ensure that specifications have been met before release
of the radiopharmaceutical(s).
A facility’s QA and QC programs must be formally established and documented in SOPs that ensure that all aspects of the
handling of radiopharmaceuticals are conducted in accordance with this chapter and applicable federal, state, and local laws
and regulations. A designated person must ensure that the facility has formal, written QA and QC programs that establish a
system of:
1. Adherence to procedures,
2. Prevention and detection of errors and other quality problems,
3. Evaluation of complaints and adverse events, and
4. Appropriate investigations and corrective actions.
The SOPs must describe the roles, duties, and training of the personnel responsible for each aspect of the QA program. The
overall QA and QC program must be reviewed at least once every 12 months by the designated person. The results of the
review must be documented and appropriate corrective action taken, if needed.
https://online.uspnf.com/uspnf/document/1_GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US 23/28
www.webofpharma.com
Printed on: Wed Feb 08 2023, 11:06:36 PM(EST) Status: Currently Official on 09-Feb-2023 DocId: GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US
Printed by: Dang Van Vu Official Date: Official as of 01-Dec-2020 Document Type: GENERAL CHAPTER @2023 USPC
Do Not Distribute DOI Ref: rog9b DOI: https://doi.org/10.31003/USPNF_M11915_04_01
24
al
radiopharmaceutical. If a complaint does, an investigation into the potential cause of the problem must be completed. The
investigation must consider whether the quality problem could extend to other radiopharmaceuticals. Corrective action, if
necessary, must be implemented for all potentially affected radiopharmaceuticals. Consider whether to initiate a recall of
potentially affected radiopharmaceuticals and whether to cease sterile compounding until all underlying problems have been
identified and corrected.
ci
A readily retrievable record (written or electronic) of each complaint must be kept by the facility, regardless of the source of
the complaint (e.g., e-mail, telephone, mail). The record must contain the name of the complainant, the date the complaint
was received, the nature of the complaint, the response to the complaint, and, if known, the name and strength of the
radiopharmaceutical and the assigned internal identification number (e.g., prescription, order, or lot number).
The record must also include the findings of any investigation and any follow-up. Records of complaints must be easily
ffi
retrievable for review and evaluation for possible trends and must be retained in accordance with the record keeping
requirements in 9. Documentation. A radiopharmaceutical that is returned in connection with a complaint must be quarantined
until it is destroyed after completion of the investigation and in accordance with applicable jurisdictional laws and regulations.
Adverse events potentially associated with the quality of radiopharmaceuticals must be reported in accordance with the
facility’s SOPs and all applicable jurisdictional laws and regulations. In addition, adverse events potentially associated with the
quality of the radiopharmaceutical preparation should be reported to the applicable jurisdictional regulatory body (e.g., state
boards of pharmacy, state health departments, FDA’s MedWatch program for human drugs).
GLOSSARY
Administration: The direct and immediate application of a radiopharmaceutical to a patient by injecting, infusing,
ingesting, or otherwise providing a radiopharmaceutical in its final form.
Airlock: A space with interlocked doors, constructed to maintain air pressure control when items move between two
adjoining areas.
Ante-room: An ISO Class 8 or cleaner area with fixed walls and doors where personnel hand hygiene, garbing procedures,
and other activities that generate high particulate levels are performed. The ante-room is the transition area between the
unclassified area in a facility and the classified buffer area.
Aseptic processing or preparation: A process by which separate, sterile components (e.g., drugs, containers, or
closures) are brought together under conditions that maintain their sterility.
Aseptic technique: Methods utilized during the processing of radiopharmaceuticals to keep objects and areas free of
microorganisms and thereby minimize infection risk to the patient. It is accomplished through practices that maintain the
microbe count at a nearly irreducible number.
As low as (is) reasonably achievable (ALARA): The effort to maintain exposures to ionizing radiation as far below the
dose limits as practical. These efforts should be consistent with the purpose for which the licensed activity is undertaken, in
relation to utilization of licensed materials in the public interest. Limiting exposure time, using adequate shielding, and
maintaining the most distance possible from all radioactive sources (i.e., time, distance, shielding) are the basic principles for
successfully following ALARA guidelines.
Authorized nuclear pharmacist (ANP): A pharmacist recognized by the U.S. Nuclear Regulatory Commission or an
Agreement State agency as having met training and experience requirements for the practice of nuclear pharmacy.
Authorized user (AU): A physician recognized by the U.S. Nuclear Regulatory Commission or an Agreement State agency
as meeting training and experience requirements for specified medical uses of radioactive material.
Beyond-use date (BUD): The assigned date and time beyond which the radiopharmaceutical must not be administered.
Biological safety cabinet (BSC) Class II: A ventilated cabinet with an open front and inward and downward
unidirectional HEPA-filtered airflow and HEPA-filtered exhaust.
https://online.uspnf.com/uspnf/document/1_GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US 24/28
www.webofpharma.com
Printed on: Wed Feb 08 2023, 11:06:36 PM(EST) Status: Currently Official on 09-Feb-2023 DocId: GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US
Printed by: Dang Van Vu Official Date: Official as of 01-Dec-2020 Document Type: GENERAL CHAPTER @2023 USPC
Do Not Distribute DOI Ref: rog9b DOI: https://doi.org/10.31003/USPNF_M11915_04_01
25
Blood components: Any constituent of blood that is separated by physical or mechanical means (e.g., red cells, white
cells, platelets)
Buffer area: An ISO Class 8 or cleaner area with fixed walls and doors where PEC(s) that generate and maintain an ISO
Class 5 environment are physically located. The buffer area may only be accessed through the ante-room.
Chemical purity: The fraction of the total chemical species present in the radiopharmaceutical as the specified chemical
component(s). A chemical impurity is the presence of an unwanted non-radioactive chemical.
Classified area: An area that maintains an air quality classification based on the ISO guidelines (i.e., ante-room, buffer
area). See ISO class.
Cleaning agent: A material for the removal of residues (e.g., dirt, debris, microbes, and residual drugs or chemicals) from
surfaces.
Compounding: The combining, mixing, pooling, or otherwise altering (excluding preparation with minor deviations) of a
conventionally manufactured radiopharmaceutical or synthesizing/formulating a radiopharmaceutical from bulk drug
substances and radionuclides. See Preparation with minor deviations.
Container–closure system: The packaging components that contain or come in contact with the radiopharmaceutical
and maintain the integrity of the radiopharmaceutical contained within. Examples include (but are not limited to) vials, tubes
and syringes.
Critical site: A location that includes any component or fluid pathway surface (e.g., vial septa, injection ports) or openings
(e.g., needle hubs) that, when exposed is at risk for contamination by direct contact with air (e.g., ambient area or HEPA-filtered),
moisture (e.g., oral and mucosal secretions), or touch.
Designated person: One or more individuals assigned to be responsible and accountable for the performance and
operation of the radiopharmaceutical processing facility and for personnel who prepare, compound, dispense, and repackage
radiopharmaceuticals.
Direct infusion system: An FDA-cleared medical device used to dispense and/or administer radiopharmaceuticals to
al
multiple patients. The standards of this chapter pertain to devices with ambient air that lack and ISO Class 5 environment.
Direct processing area (DPA): An area within the ISO Class 5 PEC where critical sites are exposed to unidirectional
HEPA-filtered air, also known as first air.
Disinfectant: A chemical or physical agent used on inanimate surfaces and objects to destroy microbiological
contamination (e.g., fungi, viruses, and bacteria) when used in the appropriate concentrations and for the appropriate contact
Dispensing: The manipulation or labeling of a radiopharmaceutical to render it in its final form for administration, typically
obtained from a single-dose or multiple-dose container (e.g., withdrawing a volume of finished product or preparation from a
vial into a syringe). Dispensing is performed under the supervision of a physician or pharmacist and for radiopharmaceuticals
ffi
includes dilution with an appropriate diluent or adjusting the activity in an individual dosage.
Dose pooling: The combining of doses from two or more syringes to meet one patient’s need, also see “repackaging”.
Dose splitting: The splitting of a patient-ready unit dose for use with more than one patient.
Dynamic operating conditions: Conditions in the SRPA or classified area in which operating personnel are present and
performing actual or simulated activities. The PEC should contain equipment and materials regularly used for
radiopharmaceutical processing (e.g., low-lint absorbent pads, dose calibrator, syringe shields).
O
Expiration date: For conventionally manufactured radiopharmaceuticals, the specified date (and time) beyond which the
product must not be administered. The expiration date is determined by the manufacturer.
First air: The air exiting the HEPA filter in a unidirectional air stream.
Garb: Gloves, gowns, shoe covers, head (covers ears and all hair) and facial hair covers, masks, and other items designed
to reduce particle shedding from personnel and minimize the risk of microbiological contamination to radiopharmaceuticals.
High efficiency particulate air (HEPA) filtration: Using a tested and certified air filter designed to remove 99.97% of
airborne particles measuring 0.3-micron or greater in diameter from the air passing through it.
Hot-cell: A device used for the shielding and containment of radioactive materials. The shielding material(s) (e.g., lead) is
generally incorporated into the structure of the unit itself. Radiopharmaceutical personnel carry out the majority of the tasks
within the hot-cell from the exterior of the unit. This is accomplished by the use of remote manipulation systems (e.g.,
manipulator arms, automated dispensing system) of various designs. Numerous air quality configurations of the hot-cell may
exist, including integrated HEPA filtration systems to render all or a specified portion (DPA) of the device capable of certifying
to a controlled ISO Class 5 environment. In other situations, the hot-cell offers only radiation protection and a laminar flow PEC,
capable of achieving an ISO Class 5 environment, is placed within the enclosure to allow for safe aseptic manipulations. A
hot-cell may also be referred to by other designations (e.g., shielded isolator with laminar flow, PET dispensing station,
manipulator hot-cell, shielded isolators for dispensing, radiopharmaceutical dispensing isolator).
Hot lab: Unclassified radiopharmaceutical processing area located within a hospital or clinical site that is only appropriate
for immediate use radiopharmaceuticals if there is not an ISO 5 PEC within SRPA located within the area.
Immediate use: A preparation (including preparations with minor deviations) and/or dispensing of a sterile
radiopharmaceutical that is limited for a single patient. Only sterile conventionally manufactured drug products (e.g., NDA,
ANDA) or drugs produced under an approved IND or RDRC protocol may be used. Administration must begin within 1 hour
of the first container puncture or exposure of any critical site involved (e.g., syringe tip, needle hub or needle) to ambient air,
whichever is first.
Individual dose (unit dose): A radiopharmaceutical in its final form ready for administration (e.g., capsule, sterile solution
in a syringe) consisting of the amount (dose) prescribed, ordered, or other intended for an individual patient or research subject.
Inverse square law: The specified physical quantity or intensity of a radiation emission is inversely proportional to the
square of the distance from the source of the emission.
ISO class: A quality classification from the International Organization for Standardization based on quantity and size of
particles per volume of air.
https://online.uspnf.com/uspnf/document/1_GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US 25/28
www.webofpharma.com
Printed on: Wed Feb 08 2023, 11:06:36 PM(EST) Status: Currently Official on 09-Feb-2023 DocId: GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US
Printed by: Dang Van Vu Official Date: Official as of 01-Dec-2020 Document Type: GENERAL CHAPTER @2023 USPC
Do Not Distribute DOI Ref: rog9b DOI: https://doi.org/10.31003/USPNF_M11915_04_01
26
Kit: Conventionally manufactured package containing all ingredients required to prepare a radiopharmaceutical with the
exception of the radionuclide.
Kit-splitting (fractionation): The act of dividing the contents of a kit vial and transferring aliquots into other containers
for storage and subsequent radiolabeling.
Ligand: An ion or molecule that incorporates a metal atom to form a coordination complex.
Line of demarcation: A visible line on the floor that separates the clean and less clean sides of the ante-room.
Low-lint wiper: A wiper exhibiting few, if any, fibers or other particulates, visible without magnification, which are separate
from, or easily removed from, the wiper material in a dry condition.
Master Formulation Record (MFR): A document or set of documents specifying the starting materials with their
quantities and the packaging materials, together with a description of the procedures and precautions required to produce a
specified quantity of a finished preparations as well as the processing instructions, including the in-process controls.
Media-fill test: A simulation used to qualify processes and personnel engaged in sterile radiopharmaceutical processing
to ensure that the processes and personnel are able to prepare radiopharmaceuticals without microbiological contamination.
Molar mass: The measured mass that is attained from a molar amount of a given substance (e.g., element, compound).
It is generally expressed with units such as g/mol and kg/mol.
Multiple-dose container: A container of a radiopharmaceutical for administration that is designed to contain more than
one patient dose of the radiopharmaceutical.
Negative-pressure area: An area that is maintained at lower pressure than the adjacent spaces, and therefore the net
airflow is into the area. This area is appropriate for volatile or gaseous radionuclides and radiopharmaceuticals (e.g., I-131 NaI,
N-13 ammonia) and intended to lend a measure of protection for the radiation workers and the general public.
One-step disinfectant cleaner: A product with an EPA-registered claim (or equivalent) that it can clean and disinfect a
nonporous surface in the presence of light to moderate organic soiling without a separate cleaning step.
Pass-through: An enclosure with sealed doors on both sides to ensure that both doors are not opened at the same time.
al
The pass-through is positioned between two spaces creating an airlock for the purpose of minimizing particulate transfer while
moving materials from one space to another.
Perimeter: A visible demarcation on the floor that defines the boundaries of the SRPA.
Positive-pressure area: An area that is maintained at higher pressure than the adjacent spaces, and therefore the net
airflow is out of the area.
ci
Preparation: The act of combining a conventionally manufactured kit with a conventionally manufactured radionuclide
following manufacturer’s recommended instructions. Mixing, reconstituting, combining, diluting, or repackaging of a
radiopharmaceutical, or other such acts, performed in accordance with directions contained in the FDA-approved labeling.
Preparation with minor deviations: The act of preparing a conventionally manufactured kit with a conventionally
manufactured radionuclide with volume, and/or radioactivity, and/or step-by-step deviations from the manufacturers
ffi
recommended labeling while ensuring that the final preparation maintains appropriate radiochemical and radionuclidic purity
for the entirety of the BUD. Examples of minor deviations include, but are not limited to, altering the amount of activity or
volume added to the vial, changes in step-by-step operations (e.g., dilute Tc-99m solution after, rather than before, addition
to the vial, use of a venting needle or filter), using alternative devices or equipment (e.g., a heating block rather than a hot
water bath), and using alternative radiochemical purity testing methods.
Primary engineering control (PEC): A device or zone that provides an ISO Class 5 air quality environment for sterile
O
processing.
Pyrogen: A substance that induces a febrile reaction in a patient.
Quality assurance (QA): The system of procedures, activities, and oversight that ensures that radiopharmaceutical
processing consistently meets quality standards.
Quality control (QC): The sampling, testing, and documentation of results that, taken together, ensure that specifications
have been met before release of the radiopharmaceutical.
Radioactive materials (RAM) license: A document(s) issued by the US NRC or an Agreement State agency that
authorizes various activities involving the use of radioactive materials. These uses can include possession, research and
development, distribution, medical use, and other purposes not included in this list. Only those activities specifically authorized
are allowed.
Radioassay: Measurement of the quantity of radioactivity present in a container using a suitable and calibrated instrument,
such as a well-type ionization chamber (i.e., dose calibrator).
Radiochemical purity: The ratio, expressed as a percentage, of the radioactivity of the intended active
radiopharmaceutical ingredient to the total radioactivity of all radioactive ingredients and impurities present in the
radiopharmaceutical preparation (see Radioactivity á821ñ).
Radionuclidic purity: The ratio, expressed as a percentage, of the radioactivity of the intended radionuclide to the total
radioactivity of all radionuclides in the radiopharmaceutical preparation (see á821ñ).
Radiopharmaceutical (radiopharmaceutical preparation/radioactive drug): (See á821ñ.) A finished dosage form
that contains a radioactive substance in association with one or more other ingredients and that is intended to diagnose, stage
a disease, monitor treatment, or provide therapy. A radiopharmaceutical includes any non-radioactive reagent kit or
radionuclide generator that is intended to be used in the preparation of any such substance. The terms “radiopharmaceutical”
and “radioactive drug” are commonly used interchangeably.
Repackaging: The act of removing a conventionally manufactured radiopharmaceutical from the container in which it was
distributed by the original manufacturer and placing it into a different container without further manipulation of the product.
Repackaging also includes the act of placing the contents of multiple containers (e.g., vials) of the same finished drug product
into one container, as long as the container does not include other ingredients. Radiopharmaceutical manipulation in any other
way, including reconstitution, dilution, mixing, or combination with another ingredient, is not considered repackaging.
Restricted area: Any area to which access is controlled for the protection of individuals from exposures to radiation and
radioactive materials.
https://online.uspnf.com/uspnf/document/1_GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US 26/28
www.webofpharma.com
Printed on: Wed Feb 08 2023, 11:06:36 PM(EST) Status: Currently Official on 09-Feb-2023 DocId: GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US
Printed by: Dang Van Vu Official Date: Official as of 01-Dec-2020 Document Type: GENERAL CHAPTER @2023 USPC
Do Not Distribute DOI Ref: rog9b DOI: https://doi.org/10.31003/USPNF_M11915_04_01
27
Secondary engineering control (SEC): The area where the PEC is placed (e.g., a classified area or an SRPA). It
incorporates specific design and operational parameters required to minimize the risk of microbial contamination.
Segregated radiopharmaceutical processing area (SRPA): A designated, unclassified space, area, or room with a
defined (by facility procedures) perimeter that contains a PEC. An SRPA is only suitable for radiopharmaceutical preparation
(with and without minor deviations), dispensing, and repackaging. If the SRPA is used to elute radionuclide generators it must
have ISO Class 8 particle count non-viable particle count air quality.
Shielding: Barriers of appropriate radiation attenuating material, used for radiopharmaceuticals, to protect the personnel.
These barriers can be general in nature (e.g., L-block, hot-cell), as to afford protection from a radiation field, or specific to a
container used to hold a particular radiopharmaceutical (e.g., syringe shield, vial shields, “pigs”).
Single-dose container: A container of a radiopharmaceutical for administration that is designed for use with a single
patient as a single administration.
Specific activity: The radioactivity of a radionuclide per unit mass of the compound involved with the radionuclide (see
Radioactivity—Theory and Practice á1821ñ). The units of specific activity involve those for the activity (e.g., mCi, MBq, Ci, GBq)
and those for the unit of mass (e.g., µg, mmol); expressed on an activity per mass basis (e.g., mCi/µg, MBq/µg, Ci/mmol, GBq/
mmol).
Sporicidal agent: A chemical or physical agent that destroys bacterial and fungal spores when used in sufficient
concentration for a specified contact time. It is expected to kill all vegetative microorganisms.
Start of preparation: Time at which a vial septum is punctured or a component container is opened (e.g., removal of
cap on a pre-filled syringe), whichever comes first.
Sterility: The absence of viable microorganisms.
Strength: The radioactivity concentration of the radiopharmaceutical at the calibration time (see á821ñ). Strength is
expressed as the quantity of radioactivity on a volume basis (e.g., mCi/mL or MBq/mL).
Unclassified space: A space not required to meet any ISO air cleanliness classification.
al
Unrestricted area: An area in which a person should not be exposed to radiation levels in excess of 2 millirems in any 1 h
from external sources.
Use-by time: For radiopharmaceuticals prepared from kits, the time period after preparation during which the
radiopharmaceutical should be used or administered, as suggested or stated in the manufacturer’s prescribing information.
ci APPENDIX
Abbreviations
ACPH Air changes per hour
ffi
ALARA As low as reasonably achievable
AU Authorized user
O
https://online.uspnf.com/uspnf/document/1_GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US 27/28
www.webofpharma.com
Printed on: Wed Feb 08 2023, 11:06:36 PM(EST) Status: Currently Official on 09-Feb-2023 DocId: GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US
Printed by: Dang Van Vu Official Date: Official as of 01-Dec-2020 Document Type: GENERAL CHAPTER @2023 USPC
Do Not Distribute DOI Ref: rog9b DOI: https://doi.org/10.31003/USPNF_M11915_04_01
28
Abbreviations (continued)
NRC Nuclear Regulatory Commission
RH Relative humidity
al
ci
ffi
O
https://online.uspnf.com/uspnf/document/1_GUID-4F561781-FBF6-4AF6-AF64-89A06583B7A1_4_en-US 28/28