0% found this document useful (0 votes)
62 views12 pages

Getinge Range of Operating Tables Brochure Anz en Anz

Uploaded by

abdullah.zahid
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
62 views12 pages

Getinge Range of Operating Tables Brochure Anz en Anz

Uploaded by

abdullah.zahid
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

Range of Operating Tables

Offering flexibility across multiple disciplines


2 R A N G E O F O P E R AT I N G TA B L E S
A full range of
operating tables
Solutions for every discipline
Getinge is built on a genuine compassion for people’s
health, safety, and wellbeing.

Founded in 1904 with roots dating back to 1838, The modular design of OR table systems support
Getinge has grown organically and through virtually unlimited positions and ideal adjustment
acquisitions to become a global market leader. ranges.
Our product portfolio offers solutions and
support throughout the clinical pathway and Our OR tables offer product functionality,
features many well known product brands. versatility and flexibility. With over 450 table
accessories Getinge provides you with the
Getinge offers a range of operating table systems flexibility to meet your surgical requirements.
designed for multidisciplinary applications.
The Maquet OR tables provide solutions across
multiple surgical disciplines and requirements.
The wide range of versions include manually and
electro-hydraulically operated models.

R A N G E O F O P E R AT I N G TA B L E S 3
Maquet Magnus
OR table system

Extension Basic table


Head rest Back plate Joint module
plate top
1180.53 1180.31 1180.11
1180.32 1180.10

General surgery • •

Gynecology / Urology • •

Traumatology /
Orthopedics • •

Spinal surgery • • • • •

Neurosurgery • • • • •

Cardiovascular surgery • •

Ophthalmology / ENT • • • • •
380 kg
Max. overall load (837.8 lbs)

Manual adjustment Head rest

Motor-powered Height, tilt, inclination, 460 mm (18.1”) longitudinal


shift, lower back plate, individual leg plate
adjustment adjustment

Special features Maximum possible range of adjustment and intuitive operation


Easy conversion thanks to Easy Click system
Pressure-relieving positioning for patient comfort
Ideally suited for intraoperative fluoroscopy
Suitable for Hybrid ORs
Quick patient transportation with no need for repositioning, for outpatient
surgery as well as major operations

4 R A N G E O F O P E R AT I N G TA B L E S
Magnus carbon fibre table
Joint module Pair of leg plates Transfer table top
top
1180.11 1180.54 1180.13
1180.16

• •

• •

• • •

• •

• • •

150 - 250 kg (330.7 -


180- 250 kg (396.8 - 551.2 lbs)
551.2 lbs)

Head rest

Height, tilt, inclination, Height, tilt, inclination,


220 mm (8.7”) longitudinal shift, 600 - 1000 mm (23.6 - 39.4”)
back plate, leg plate longitudinal shift, 100 mm
(3.9”) lateral shift

Can be used in conjunction with MR Radiolucency 3D from 1250


compatible transfer board to 1850 mm, AP from 600mm -
1000mm designed for optimum
use in Hybrid ORs

R A N G E O F O P E R AT I N G TA B L E S 5
Maquet Otesus
OR table system

Universal table top Universal table top


1160.30 1160.10

General surgery • •

Gynecology / Urology • •

Traumatology /
Orthopedics • •

Spinal surgery • •

Neurosurgery • •

Vascular surgery • •

Ophthalmology / ENT • •

Max. overall load 380 kg (838 lbs) 380 kg (838 lbs)

Manual adjustment

Motor-powered drive of the OR table top for the Motor-powered drive of the OR table top for
Motor powered functions longitudinal shift, lower back plate up / the functions longitudinal shift, lower back
adjustment down, upper back plate up / down and leg plates up / plate up / down and leg plates up / down, can
down, can be performed together or individually. be performed together or individually.

All drives are equipped with electronic dynamically All drives are equipped with electronic
regulated smooth-start function for the jolt-free start dynamically regulated smooth-start function
of all movements. for the jolt-free start of all movements.

Special features Three motor-driven joint pairs offer all options for Modular OR table top with identical mounting
demanding patient positioning. points on both motor-driven joints for the
adaptation of back segment, seat plate, head
rest and leg plates.

6 R A N G E O F O P E R AT I N G TA B L E S
Carbon fibre table top
1150.16

245 kg (540.1 lbs)

Head rest

Height, tilt, inclination,


1200 mm (47.2”) longitudinal
shift, 100 mm (3.9”) lateral
shift

Longitudinal and lateral shift,


joystick control,
table top made completely of
carbon fiber, 360º radiolucency

R A N G E O F O P E R AT I N G TA B L E S 7
Maquet Alphamaxx, Meera and
Yuno II
Mobile OR tables

Alphamaxx
Meera mobile operating YUNO II mobile operating
mobile operating
table table
table
7200.01 1433.02
1133.22

General surgery • • •

Gynecology / Urology • •

Traumatology /
Orthopedics • • •

Spinal surgery • • •

Neurosurgery • • •

Vascular surgery • • •

Ophthalmology / ENT • • •

Max. overall load 450 kg (992.1 lbs) 454 kg (1000 lbs) 454 kg (1000 lbs)

Manual adjustment Head rest, Head rest, Head rest,


upper back plate upper back plate extension device,
traction bars

Motor-powered Height, tilt, inclination, Height, tilt, inclination, Height, tilt, inclination,
lower back plate, lower back plate, leg plates, lower back plate, leg plates
adjustment
individual leg plate adjustment, 310 mm (12.2”) longitudinal shift
460 mm (18.1”) longitudinal shift

Special features Optional auto drive, modular design, Optional auto drive, modular Special-purpose table for
reverse positioning design, reverse positioning orthopedics, traumatology and
neurosurgery, radiolucency,
Operation via: Operation via: good access, extremely stable,
corded hand control, IR hand control, corded hand control, IR hand lightweight materials, quick
foot switch, override control panel, control, override control panel, conversion process
SENSOR DRIVE SENSOR DRIVE

8 R A N G E O F O P E R AT I N G TA B L E S
Maquet Alphaclassic Pro and
Betaclassic

Alphaclassic Pro mobile operating


Betaclassic mobile operating table
table
1118.01
1118.06

• •

• •

• •

• •

• •

• •

• •

360 kg (793.6 lbs) 155 kg (341.7 lbs)

Leg plates, head rest, Height, tilt, inclination,leg


optional 310 mm (12.2”) plates, back plate, head
longitudinal shift rest optional 290 mm (11.4”)
longitudinal shift

Height, tilt, inclination,


lower back plate

Optional 310 mm (12.2”) longitudinal Optional 290 mm (11.4”)


shift longitudinal shift

Operation via: Operation via:


corded hand control, pedal with function selector
IR hand control, switch
foot switch,
override control panel

R A N G E O F O P E R AT I N G TA B L E S 9
The Hybrid OR
The future of surgery

A single surgical workspace that In many cases, fixed-column tables with


combines imaging equipment with a specially designed table tops make it possible
multifunctional surgical table to have a risk reducing single patient transfer
It allows clinicians to diagnose and treat and from initial admittance in the ER through the
confirm the final result in one room in a single Hybrid or traditional OR and ICU.
location, reducing risk and delays, due to The Hybrid OR offers benefits for all key
transferring patients between departments or stakeholders. For surgeons, ergonomic, and
theatres, and ultimately to help minimise costs flexible patient positioning throughout the
by reducing the need for repeated or entire procedure is of paramount importance,
corrective surgery. given the range and complexity of surgeries
that will be performed in the Hybrid OR.
One room, multiple uses –
the possibilities are endless Benefits patients, clinicians and
Once limited to cardiovascular procedures hospitals
in the cath lab, image-guided surgery has • Aiming to provide effective hygiene and
expanded to comprise nearly all surgical sterility
disciplines, including cardiovascular, • Reducing downtime between procedures
neurosurgery, oncology, orthopaedic, urology, • Providing effective radio translucency in all
bariatric and traumatology procedures – all of areas of interest
which benefit from intraoperative imaging. • Accommodating a wide range of patient
weights
The surgical table top not only meets the • Permitting the rapid transport/ transfer of
needs of multiple surgical disciplines but also patients within the OR environment (OR
balances the need for planning when used for table to MRI) as well as in and out of the
advanced imaging. Additionally, fixed-column surgical suite with either no or minimal
surgical tables help eliminate the potential for need for repositioning
collisions whilst giving surgeons concurrent
access to the imaging device and patient.

10 R A N G E O F O P E R AT I N G TA B L E S
R A N G E O F O P E R AT I N G TA B L E S 11
With a firm belief that every person and community should have access to the best possible care, Getinge provides hospitals and
life science institutions with products and solutions aiming to improve clinical results and optimise workflows. The offering includes
ANZ_SW_V1_007_0520

products and solutions for intensive care, cardiovascular procedures, operating rooms, sterile reprocessing and life science. Getinge
employs over 10,000 people worldwide and the products are sold in more than 135 countries.

© 2020 Getinge Australia Pty Ltd ABN 67 009 673 518


Australian Phone: 1800 438 464 Email: [email protected]
New Zealand Phone: 0800 1 438 4643 Email: [email protected]

www.getinge.com/anz

You might also like