SPD 20 Spec - 2

The document provides specifications and installation instructions for Mean Well's SPD-20 series surge protection devices. The SPD-20 series features Type 2 component assemblies, LED status indicators, and 10kV surge protection capability. The document outlines the device specifications, mechanical dimensions, installation warnings and procedures.

Uploaded by

Richard Febrino
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
38 views2 pages

SPD 20 Spec - 2

The document provides specifications and installation instructions for Mean Well's SPD-20 series surge protection devices. The SPD-20 series features Type 2 component assemblies, LED status indicators, and 10kV surge protection capability. The document outlines the device specifications, mechanical dimensions, installation warnings and procedures.

Uploaded by

Richard Febrino
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

20kA Surge Protection Device SPD-20 series

■  User’s Manual


‧
‧
‧
‧
‧
‧
■  ‧
 
SPECIFICATION (Only SPD-20-240P) (Only SPD-20-240P) IP67
MODEL SPD-20-240P SPD-20-277P
OPERATING VOLTAGE 240VAC 50/60Hz 277VAC 50/60Hz
MCOV(MAX. CONTINUOUS OPERATING VOLTAGE) 300VAC 320VAC
UC(MAX. CONTINUOUS OPERATING VOLTAGE)Note.4 300VAC ------
VPR (VOLTAGE PROTECTION RATING) 1500V(L-FG,N-FG,L-N)
UP (VOLTAGE PROTECTION LEVEL)Note.5 1500V(L-PE,N-PE,L-N) ------
IN (NOMINAL DISCHARGE CURRENT) 5kA
MAX. SURGE CURRENT(8/20us) 20kA
Imax. (MAX. DISCHARGE CURRENT) Note.6 20kA ------
SCCR (SHORT CIRCUIT CURRENT RATING)Note.3 5kA
SHORT-CIRCUIT WITHSTAND Note.7 1.5kA ------
RESPONSE TIME <25ns
WITHSTAND Note.1 1600VAC 1minutes
OPERATING TEMPERATURE -40 ~ +70℃
SAFETY STANDARDS UL1449(Third Edition),CS22.2 NO.8,BS EN/EN61643-11(only SPD-20-240P), EAC TP TC 004 approved
MTBF 4508.6K hrs min. Telcordia SR-332 (Bellcore) ; 7162.4K hrs min. MIL-HDBK-217F (25℃)
DIMENSION 90*70*50mm (L*W*H)
PACKING 0.39Kg; 18pcs/8Kg/0.84CUFT
NOTE
1. Varistors are to be removed during this test
2. Note.4,Note.5,Note.6,Note.7 are for BS EN/EN61643-11(SPD-20-240P)
3. These devices have been subjected to Surge Testing and Current Test-short Circuit Current Rating by employing a class J Fuse Rated 30A and minimum 600VAC.
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification CONNECTIONS

Case No. SPD-20A Unit:mm L


90
5.1
N
2

150±5 FG
LED
10AWG FEP AC/N AC/L
5.1

ψ4.2

AC/L(BLACK) SPD
150±5
70

150±5
FG/PE
10AWG FEP 10AWG FEP FG(GREEN)
PE(GREEN)
ψ4.2
AC/N(WHITE)
LED

2
5.1

5.1

3.19 3.19
50
28
3
18

File Name:SPD-20-SPEC 2022-02-18


20kA Surge Protection Device SPD-20 series

Circuit Diagram
AC/N

D2 LED2 R2

ZNR1
AC/L

ZNR3
ZNR2 D1 LED1 R1

FG/PE

INSTALLATION
1. This document provides detailed information on how to install and operate the SPD-20
of Surge Protective Devices(SPDS).
2. The SPD-20 of Surge Protective Devices are installed/connected in parallel with the line of TN System
3. Incorrect installation may significantly impair the performance of the SPD. It is particularly important
that all installation procedures and guidelines be followed exactly.
4. Before starting any installation procedures, verify service voltage(AC or DC)with a volt
meter to ensure that the correct model has been selected for the supply voltage.
5. DO NOT INSTALL THE SPD IF MEASURED VOLTAGE EXCEEDS UNIT RATINGS.
6. REMOVE POWER FROM ELECTRICAL SYSTEM PRIOR TO INSTALLATION.
7. ENSURE THAT ALL CONNECTIONS ARE CORRECT BEFORE ENERGIZING.
8. Apply power(energize),LED indicator should illuminate. If LED is out, the SPD requires service.
9. Never install on an ungrounded system.

! DANGER

HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH

Thoroughly read and comprehend all instructions before commencing installation.

This equipment must be installed by qualified electrical personnel in accordance with


all applicable codes which supersede these instructions.

Improper installation or misapplication of these devices may result in death or serious injury.

Failure to follow these instructions could result in damage to the electrical system(s) or related equipment.

! CAUTION

HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH

Never install this unit if it has fallen, has been dropped or looks damaged in any way.
Return device to factory for diagnostic testing.

File Name:SPD-20-SPEC 2022-02-18