Datasheet: 40gbe Data Center Switch Powered by Cumulus® Linux®
Datasheet: 40gbe Data Center Switch Powered by Cumulus® Linux®
com
AS6701-32X-C
40GbE Data Center Switch
Powered By Cumulus® Linux®
Product Overview
The Edge-Core AS6701-32X-C is a high-performance standard Data Center switch for top-of-rack (TOR) or spine
applications. In a compact 1RU form factor, this switch provides line-rate L2 and L3 switching across up to 32
QSFP+ ports, supporting up to 32 x 40GbE connections or 104 x 10GbE connections. The AS6701-32X-C can be
deployed as a TOR switch supporting 10GbE or 40GbE server connections, or as a spine switch, supporting
10GbE or 40GbE spine interconnects. The switch provides 20 fixed QSFP+ ports and two modular slots, each
capable of supporting 6 x QSFP+ ports or a future NPU module for deep packet inspection, traffic analysis or other
applications. The AS6701-32X-C comes with Cumulus Linux — the leading network OS for data center switching
systems.
Cumulus Linux
Cumulus Linux is a Linux operating system that runs on top of industry-standard networking hardware. It is a
software-only solution that accelerates robust networking functions at wire rate on a variety of platforms and is the
ultimate choice when it comes to flexibility and innovation, enabling the best-of-breed hardware ecosystem and
best-of-breed application ecosystem.
Cumulus Linux is Linux. It is not just based on Linux, it is Linux and offers the entirety of the Linux experience on
networking hardware. Existing open source and commercial Linux applications run natively on industry-standard
switches. New applications can be developed and integrated rapidly, enabling innovation cycles on par with
software and application cycles.
Features
Features
Cumulus Linux Features
Functionality Description
Operating System Install & Upgrade Server-style upgrade/patching across minor releases, server-style process restart/
termination. Support for zero touch OS installation using ONIE loaded on industry
standard switches.
Extensibility Linux extensibility — Any language supported in Linux today, including scripting with
Bash, Python, Perl, Ruby
Hardware Management The switch hardware abstraction layer accelerates Linux kernel networking constructs
in hardware, including the routing table, ARP table, bridge FDB, ip/ebtables, bonds,
VLANs, VXLAN bridges. Hardware management also includes jumbo frames support
and environmental management
Layer 3 Features Enhanced Quagga IPv4/v6 routing suite including OSPFv2, OSPFv3, BGPv4/v6,
Equal-Cost Multi-Path (ECMP). Bidirectional Forwarding Detection (BFD).
Layer 2 Features Bridge management with MSTPd including STP (IEEE 802.1d), RSTP (IEEE 802.1w),
PVRST, PVST, bridge assurance, BPDU guard, BPDU filter. VLAN trunks (IEEE
802.1q), LACP (IEEE 802.3ad), unicast/broadcast storm control, LLDP, CDP, IPv6
neighbor discovery, IPv6 route advertisement. Host HA (through Host-MLAG).
IGMPv2/v3 snooping, MLDv1/v2 snooping. Virtual Router Redundancy (VRR).
Network Virtualization VXLAN support*, L2 gateway services integration with VMware NSX *, Lightweight
Network Virtualization (LNV)*.
Management Native Linux management tools such as OpenSSH, SCP, FTPS. Automated Install/
Upgrade: zero touch install and zero touch provisioning. DHCP, v4/v6 DHCP relays.
Authentication with LDAP, authorization with sudo NTP. Advanced management/
orchestration through third party add-on packages.
Monitoring & Troubleshooting Traditional monitoring with SNMPv2/v3 and network-specific MIB, analytics with SPAN,-
ERSPAN, ACL-based counters, DOM optics data, thermal sensors, real time queue-
depth and buffer utilization reporting. Troubleshooting with dnsutils, syslog, reachability
tools, hardware inventory, log fles, server-style filesystem, and merchant silicon specific
commands.A dvanced troubleshooting and ease of use with Prescriptive Topology
Manager.
Security Access control lists (ACLs) L2-L4 classification through ip/ebtables, CPU protection
through hardware enforced ACL-based rate limiting.
QoS Classification based on Class of Service (CoS) (IEEE 802.1p) or DSCP (queuing,
scheduling (DWRR and Strict Priority), buffer allocation)*. Ingress ACL-based
classification/policing.
Features
Features
Hardware Specifications
■ Cost-effective, bare-metal switch infrastructure for data center fabric.
■ Up to 32 x 40GbE ports in compact 1RU form factor.
■ Modular design allowing cost-effective build-out of an infrastructure with switching capacity added as required.
■ 20 x QSFP switch ports, each supporting 40GbE or 4 x 10GbE via breakout cables.
■ Two module slots, each supporting 6 x QSFP module or future NPU processing module.
■ Layer 2 or Layer 3 forwarding of 2.56Tbps full duplex.
■ Supports hot/cold aisle with port-to-power and power-to-port airflow SKUs.
■ All ports on front; PSUs and fans on rear.
■ Hot-swappable, load-sharing, redundant AC or -48VDC PSUs.
■ 4+1 redundant, hot-swappable fans.
■ Energy Efficiency: 267W typical power consumption.
Ports Software
Switch Ports: Preloaded with Cumulus Linux. License cost included in the price
20 QSFP fixed ports: 40GbE or 4 x10 GbE per port for the specific term described in the SKU.
2 expansion module slots, for optional modules:
6 QSFP: 40GbE or 4 x 10GbE per port Physical and Environmental
NPU module (future) Dimensions (WxDxH): 440 x 470 x 44mm (17.3 x 18.5 x
Total switch capacity: 32 x 40GbE; or 104 x 10GbE 1.73inches)
Management ports on port side: Weight: 8.4kg (18.52lbs), total with 2 modules
1 x RJ-45 serial console Fans: 4+1 redundant, hot-swappable
1 x RJ-45 100/1000BASE-T management port Operating Temperature: 0°C to 40°C (32°F to 104°F)
1 x USB Type A storage port Storage Temperature: -40°C to 70°C (-40°F to 158°F)
Operating Humidity: 5% to 95% non-condensing
Key Components
Switch Silicon: Broadcom BCM56850 Trident II 1.28Tbps Power
CPU Module: Freescale P2020 dual-core 1.2GHz PSUs: 2 redundant, load-sharing, hot-swappable AC or 48VDC
2GB DDR3 SDRAM ECC memory Input Voltage: 90 to 264VAC at 50-60Hz. -48 to -72VDC.
64MB NOR Flash, 2GB NAND Flash Input Current: Max 6A @100/120VAC, 3A @200/240VAC,
8GB SD Card 10 A @-72VDC
PSU Efficiency: Up to 93% for AC PSUs
Performance Max Power: 315W, line-rate, 32 x 40G SR4, AC
Switching Capacity: 2.56Tbps full duplex, with packets>200bytes Typical Power: 267W, line-rate, 32 x 40G DAC, AC
Forwarding Rate: 1.44Bpps
MAC Addresses: 320K Regulatory
VLAN IDs: 4K EMI
Jumbo frames (9216Bytes) CE Mark (EN55022 Class A)
L3 Routes IPv4 64K, IPv6 20K FCC Part 15 Class A
Packet Buffer Size: 12MB shared buffer pool VCCI
Latency (RFC2544): 600 to 720ns cut thru Safety
CB, EN 60950
LEDs UL/CUL
40G QSFP Port LEDs: Link Status, Activity Environmental:
Ethernet Management Port LED: Link Status, Activity Temperature: IEC 68-2-14
Console Port LED: Link Status Drop: ISTA 2A
System LEDs: Diagnostic, Locator RoHS-6 Compliant
Features
Features
Ordering Information
6701-32X-C-AC-F AS6700-32X 20-Port 40GbE QSFP switch, preloaded with Cumulus Linux, dual AC PSUs,
port-to-power airflow, dual 6-port 40G module, 1 year OS license with standard support included
6701-32X-C-AC-B AS6700-32X 20-Port 40GbE QSFP switch, preloaded with Cumulus Linux, dual AC PSUs,
power-to-port airflow, dual 6-port 40G module, 1 year OS license with standard support included
6700-32X-SVC-C AS6700-32X Additional 2 year Cumulus Linux Software License and Maintenance (*must order
together with above model)
*Note: Customers can order yearly subscription licenses for Cumulus Linux to extend beyond 3 years.
© Copyright 2014 Edge-Core Networks Corp. The information contained herein is subject to change ©2014 Cumulus Networks. All rights reserved. CUMULUS, the Cumulus Logo, CUMULUS NETWORKS,
without notice. This document is for informational purposes only and does not set forth any warranty, and the Rocket Turtle Logo (the “Marks”) are trademarks and service marks of Cumulus Networks, Inc.
expressed or implied, concerning any equipment, equipment feature, or service offered by Edge-Core in the U.S. and other countries. You are not permitted to use the Marks without the prior written consent
Networks. Edge-Core Networks shall not be liable for technical or editorial errors or omissions of Cumulus Networks.
contained herein.