The Power of Communications - Everything IP
The Power of Communications - Everything IP
© Robert Bosch Middle East FZE 2022. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
2 Internal | Building Technologies | BT/SEM | 2022-11-14
© Robert Bosch Middle East FZE 2022. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
3 Internal | Building Technologies | BT/SEM | 2022-11-14
© Robert Bosch Middle East FZE 2022. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Part I
PAVA
Multi-phase release
Up to 500 zones
PRAESIDEO 100+ Channels
Up to 500 zones (per system)
PAVIRO 28 Channel
6–492 zones Audio processing per zone
1-4 Channel Network interfaces on VoIP, DANTE and OMNEO
Lowest power consumption Open control interface for 3rd party integration
Professional sound quality
Ease of Design - Configuration comfort -
basic mode wizard & expert mode
System Size
Controller
Full control of PRAESENSA devices
and audio Routing
8 channel Amplifier
Flexible channel output and built-in redundancy
4 channel Amplifier
Flexible channel output and built-in redundancy
All components of the system are IP-networked for highest flexibility and scalability
Internal | Building Technologies | BT/SEM | 2022-11-14
© Robert Bosch Middle East FZE 2022. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Secure IP Infrastructure
48 Khz
Studio
Quality
24 Bit
4 Ch. Amplifier
8 Ch. Amplifier
Multifunction
Power Supply
Centralized Decentralized
Internal | Building Technologies | BT/SEM | 2022-11-14
© Robert Bosch Middle East FZE 2022. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Highest System Availability
Do MORE with
LESS
Rack Space
Power Consumption
Number of Amplifiers
Heat dissipation
Required Cooling
Cost
8 X 60W Amplifier
8 X 60W Amplifier
60W 60W 60W 60W 60W 60W 60W 60W 480W in Total
15W 30W 10W 15W 15W 5W 25W 115W Not used!
45W 30W 60W 50W 45W 45W 55W 35W 365W Actually Used
Internal | Building Technologies | BT/SEM | 2022-11-14
© Robert Bosch Middle East FZE 2022. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Effective Power Utilization
8 X 60W Amplifier
Redundancy?
Redundancy?
Rack Space
Power Consumption
Heat Dissipation
Rack Space
Power Consumption
Heat Dissipation
Cooling Required
Special & proprietary
Connections/cabling
Weight
Installation, Maintenance,
Spare Parts
Internal | Building Technologies | BT/SEM | 2022-11-14
© Robert Bosch Middle East FZE 2022. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Effective Power Utilization
Cost
Internal | Building Technologies | BT/SEM | 2022-11-14
© Robert Bosch Middle East FZE 2022. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Effective Power Utilization
600W
365W in Use
235W Available
DC Powered
365W in Use Integrated Spare
Amplifier Channel
1U 235W Available
MORE LESS
Number of Amplifiers Number of Amplifiers
Rack Space Rack Space
Power Consumption Power Consumption
Heat Dissipation Heat Dissipation
Cooling Required Cooling Required
Special & proprietary Special & proprietary
Connections/cabling Connections/cabling
Weight Weight
Installation, Maintenance, Installation, Maintenance,
Spare Parts Spare Parts
MORE LESS
Overall Overall
System Cost System Cost
▪ Solution for large buildings like airports and oil & gas applications
SYSTEM ▪ Possibility to split systems with system controllers per building or a part of
a building. If the sections lose the connection to each other, the divided
parts of local systems will stay operational with its locally connected
devices and call stations.
Small System
Controller
PRAESENSA
All in One
Acoustical know how, one of the Europe’s largest test and measurement facilities + 90
• Superb speech intelligibility for demanding environments years of
• Professional music quality when required experience
Broad range : we have first-rate solutions for every audio application in acoustical
• Ceiling, cabinet, column, horn, line array or sound projector technology
• Indoor & outdoor use
• IP speakers and IP amplifier module
• Explosion and weatherproof portfolio
•
•
EN 54-24 certified speakers for emergency evacuation
In-wall, on-wall, in-ceiling, on-ceiling or pending
+ 100
• Customized colors service is available loudspeakers
for every
application
Integrated microphone
Line in/out & GPIO
Internal messages
In case the microphone is not needed then it can be disabled via hardware switch
1x line-in
1x line-out
GND line-in/out
115 dB with PoE (peak 128 dB) 111 dB with PoE (peak 124 dB)
Maximum Sound pressure level (500Hz – 8kHz)
118 dB with PoE+ (peak 131 dB) 113 dB with PoE+ (peak 126 dB)
IP Amplifier model
(AMN-P15-SIP)
(local)
Loudspeaker(s)
(local)
(local) Amplifier Loudspeaker(s)
Loudspeaker out
RJ-45 network connection (low impedance)
For power (PoE), 1x GPI
communication (SIP) & control
1x line-in
1x line-out
GND line-in/out
Field
Is this
speaker
working?
Integrated MIC
detects sound
“Step away
from the
Noise level triggering fence.”
“Step away
from the
fence.”
Noise trigger
“Sorry I will
leave
immediately”
SIP
IP-PBX
Server Paging call Paging call Paging call
(IP-PBX)
LAN network
Contact closures on
Contact Closures
the different systems
Logic Future
• Compound logic and comparison operators engine proof
ONVIF cameras
PRAESENSA
Intrusion(B/G-series panel)
HW/SW Web based configuration
PRAESIDEO
Internal | Building Technologies | BT/SEM | 2022-11-14
© Robert Bosch Middle East FZE 2022. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Bosch ONVIF cameras Intelligent control PRAESENSA PRAESIDEO
EVENT 1 Action 1
definition definition
EVENT 2 Action 2
definition definition
Camera
IVA/VCA
ACTION 1 ACTION 2
EVENT 2
IP based smart Play Play
recorded recorded
EVENT 1
integration between message message
Detection
Detection
Object in
systems & devices
Line crossing
Field
USE CASES
• Make business calls from PRA into PRS on zone, zone group
or system level or visa versa
• Play BGM from an audio source connected to a PRS system
on a zone, zone group or system level of the PRA system or
visa versa
PRAESIDEO • Receive faults on the PRS system in the PRA system PRAESENSA
Non-EN54 Solution
DICENTIS
CCS900 Ultro
DCN
2003 2010 2013 2016 2020
DICENTIS
Internal | Building Technologies | BT/SEM | 2022-11-14 CCS1000D
© Robert Bosch Middle East FZE 2022. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial propertyWireless
rights.
Solutions to cover a wide range of applications
Governmental Commercial
International Business
Ministries & Parliaments / Commercial
City Councils / Organizations Centres / Convention Rental
Courtrooms Governmental Regional Buildings /
Town Halls (EU, NATO, Congress Centres Companies
other Councils Boardrooms
UN, etc.) Hotels
Rentals
CCS1000D
Digital Discussion System
DICENTIS Wireless
Conference System
• Quick set-up and break
down
• Secure Wi-Fi technology
• Smart wireless management
• True wireless connectivity
Internal | Building Technologies | BT/SEM | 2022-11-14
© Robert Bosch Middle East FZE 2022. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Applications requiring simultaneous interpretation
Infrared
radiators
INTEGRUS
Language Distribution System Transmitter
• Possible re-use of building entry • Languages are shown in native • Electronic parliamentary voting
NFC card characters or symbols • Quick ad-hoc or prepared voting
• Fast participant recognition • Only available languages are • Colored voting touch buttons
shown light up on each device when the
functionality is required.
• Daisy chain
• Using Bosch switch and cabling
• Star configuration
• Using standard POE switches and
CAT5e or higher cabling
• Flexible combination of daisy and star
DICENTIS IP platform
Handheld
Audio Mics
Interface (DCNM-FHH)
(DCNM-FAI) (DCNM-FHHC)
DCNM-FBD2
▪ Can be extended with
− voting
− language selection
− identification
− audio interface (for 3rd party microphone)
▪ Create 2 seats with own microphone button, microphone, loudspeaker and optional
priority button (in DCN NG you could only make 1 chairperson seat with a DCN-DDI)
▪ Create upto 4 seats (with shared microphone), with DCNM-LSDU
▪ Create 1 seat with 2 microphones for rostrum or chairperson
Software
▪ Configuration like all other DICENTIS participant devices, no switches on the Flush
base device
Internal | Building Technologies | BT/SEM | 2022-11-14
© Robert Bosch Middle East FZE 2022. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Flush Range Modules
Voting module
- Touch buttons
- Optimal user experience
- Color coded Icons
Identification module
- NFC card
- User guidance by lighted icon
- Optional card holder
▪ Priority button*
F F
FICH FID FVP FSLP FLSP FMCP FMICB E FICH FID FVP FSLP FLSP FMCP FMICB FPRIOB E
C C
audio audio
audio audio
DCNM-FBD2 Hea
dset
DCNM-FBD2 Hea
dset
MIC
MIC
▪ In the future, we will grow our flush range with even more features and modules
▪ Provisional space for future modules can be reserved and temporarily covered with the new wide or
slim blank flush panels
▪ City Councils
▪ Regional Councils
▪ Parliaments
▪ Conference centers
▪ Boardrooms
Why?
DCN-NG
(Analog)
Voting? Weighted
Voting?
Mic Management?
Meeting
Central Control?
Preparation?
Reliability
Security
Internal | Building Technologies | BT/SEM | 2022-11-14
© Robert Bosch Middle East FZE 2022. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
DICENTIS Hybrid Meetings
Shaping the Future of Conferencing
Not a
PROFESSIONAL
conference
DICENTIS
Hybrid Conferencing
DICENTIS
Hybrid Conferencing
Native Solution
No combination of different solutions needed
• No complex interfacing
• Hybrid in the core of the DICENTIS system
Get informed
• See agenda status, voting results, hall visuals and presentation content – even
when sitting remote
• Listen to your preferred language (simultaneous interpretation)
Peace of mind
Ensured Security
No external infringements
Access Control is managed by the local DICENTIS system
CONCEPT