0% found this document useful (0 votes)
508 views8 pages

Fermator Hinged Doors. Installation Manual

The document provides instructions for assembling and adjusting semi-automatic doors for lifts. It describes the door parts and how to fix the door to the building site. It also explains how to assemble the open-door handle and pushing plate. Adjustments for closing the doors of Global and Fermator models are covered, along with ensuring the correct situation of the lock. Optional accessories like vision panels are also mentioned.

Uploaded by

ENZO
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
508 views8 pages

Fermator Hinged Doors. Installation Manual

The document provides instructions for assembling and adjusting semi-automatic doors for lifts. It describes the door parts and how to fix the door to the building site. It also explains how to assemble the open-door handle and pushing plate. Adjustments for closing the doors of Global and Fermator models are covered, along with ensuring the correct situation of the lock. Optional accessories like vision panels are also mentioned.

Uploaded by

ENZO
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

AUTOMATIC DOORS FOR LIFTS

ASSEMBLING AND
ADJUSTMENT INSTRUCTIONS
FOR SEMIAUTOMATIC DOORS

*ACMPS1* ACMPS1 INS-TEC-GC-10.02 V1 Rev.: 02.2005


AUTOMATIC DOORS FOR LIFTS
INDEX

PARTS DESCRIPTION ................................................................................................................3

FIXATION TO THE BUILDING SITE .............................................................................................4

ASSEMBLING OF THE OPEN-DOOR HANDLE AND PUSHING PLATE ............................................4

CLOSING ADJUSTMENT OF “GLOBAL” DOORS ...........................................................................5

CLOSING ADJUSTMENT OF “FERMATOR” DOORS .......................................................................5

CORRECT SITUATION OF THE LOCK ..........................................................................................6

ACCESSORIES AND OPTIONS ....................................................................................................6

VISION PANEL ........................................................................................................6

BISTABLE MICROSWITCH ........................................................................................7

DECLARATION CE OF CONFORMITY ...........................................................................................8

2 SEMIAUTOMATIC DOORS
AUTOMATIC DOORS FOR LIFTS PARTS DESCRIPTION

1
2

8 3

8 2
4 5 DETAIL OF FERMATOR
MODEL

6
2
8
7
DETAIL OF GLOBAL
MODEL

1- Frame.
2- Damper.
8 3- Lock.
4- Vision panel (optional).
5- Push button
emplacement.
6- Metal band close-door.
7- Pushing plate.
8- Hinge.
9- Handle open-door.

SEMIAUTOMATIC DOORS 3
AUTOMATIC DOORS FOR LIFTS
FIXATION TO THE BUILDING SITE

To fix the door properly to the building


site you should:
1º Check the vertical and horizontal
level as well as the diagonals of the
panel and frame set.
2º Fix the small tongues as shown in
figure 1.
1

2
1 - Closing device depending on the
model.
fig. 1
2 - Hinge depending on the model.

ASSEMBLING OF THE
OPEN-DOOR HANDLE AND PUSHING PLATE

For assembling the open-door


handle and pushing plate, we
shuold proceed as shown in
figure 1 and 2.

Screw M6 x 10 Special screw


fig. 1 M3 x 9 fig. 2

4 SEMIAUTOMATIC DOORS
CLOSING
AUTOMATIC DOORS FOR LIFTS
ADJUSTMENT OF “GLOBAL” DOORS

For a correct closing of the


D
door, we should adjust the
pressure of the close-door
spring (C), with the help of
B
the hexagonal axle (B). C
1º Dismantle the metal part A
in a star form (A) which
obstructs the hexagonal
axle.
2º Turn the axle a quarter
turn clock-wise direction
to be able to tigher the The closing speed of the last
metal band. To be able to centimetres of the door will be adjusted
slacken it do the same in by the damper screw (D). Turning it to
the opposite way. clock-wise direction it will be more
resistence when closing, and turning
3º Place the metal sheet (A)
it to the opposite clock-wise direction
1for blocking the axle
it will be reduced.
again.

CLOSING
The correct adjustment is possible ADJUSTMENT OF “FERMATOR”
when the door is totally closed,
softly and without banging. The closing of Fermator door model is adjusted
by the damper. By three “allen” screws we
can adjust the average speed (Door), the last
centimetres (Back) and the close safety (Latch).
Turning to the clock-wise direction we will reduce
the speed and turning to the opposite direction
we will obtain an acceleration in the speed.

BACK

F
DOOR

E
The hinges allows us to adjust the situation of LATCH
the door in all directions, lateral, anterior and
For adjusting the screws we
posterior by the slots of the subjection sheet (E).
will use an “allen” key of
The height adjustmentis made by the axle (F)
3/32’’ or 2’5mm.
with a 6mm. “allen” key.

SEMIAUTOMATIC DOORS 5
AUTOMATIC DOORS FOR LIFTS
CORRECT SITUATION OF THE LOCK

Check the correct


Check that the piston is properly function of the
centred in the upper / lower sense and electrical contact,
also lateral (fig. 1). it should enter
centered and
with a correct
conection.

= Electrical contact

=
Wheel
10mm.

= Cam

= fig. 2
fig. 1 The correct distance between the wheel and the cam is 10mm.
as shown in figure 2.

ACCESSORIES AND OPTIONS


GLASS SUBSTITUTION VISION PANEL
For a glass substitution please:

1º Dissamble the aluminium frame with making some pressure


from the laterals as shown the double arrow.
2º Take off the subjection staples to be able to take out the glass.
3º Change the glass.
4º Place the staples to make sure the glassis properly fixed.
5º Pressure the aluminium frame until is fitted with drawing 1.

Aluminium frame
Fixation staples
Glass

fig. 1 Screw M3 x 9 Screw M3 x 9

6 SEMIAUTOMATIC DOORS
AUTOMATIC DOORS FOR LIFTS ACCESSORIES AND OPTIONS

BISTABLE MICROSWITCH

The Bistable microswitch is activated by a triangular key that


unlocks the lock. After every use of the triangular key must
follow a manual rearm of the electrical contact.

Diferent steps of bistable microswitch:

1º Rest position.

2º Beginning of the operation.

3º Micro operation.

4º Return to rest position.

5º Manual rearm.

Opposite detail of triangular key.

SEMIAUTOMATIC DOORS 7
ATENTION: Any type of modification not reflexed in this manual, before testing it should be notified
to our Technical Department.
TECNOLAMA declines all responsibility in the case of damages produced in the operator and
installation, if the instructions given have not been followed.
TECNOLAMA reserves the rights to modify the products specifications of this technical brochure
without any previous advise.

Declaration CE of conformity
Tecnolama, S.A.
Ctra. Constantí Km. 3
43206 REUS (Spain)

Herewith declares that the products mentioned below conform with the following E.U. council
directives:

E.U. council directive 95/16/EC, Norms EN81.1 and EN81.2:


Locking device for semiautomatic landing doors
(model S7550)

ECA CERT, S.A.


C/ Terré, 11 - 19
08017 - Barcelona
Organization 0830

Tecnolama S.A., 2006

Josep Vilà Gomis


Administrator

Ctra. Constantí, Km 3 - 43206 REUS (Spain) - Tel. +34 977 774 065 - Fax +34 977 771 615
http://www.fermator.com e-mail:[email protected]