This document provides instructions for operating and maintaining a digital inverter generator. It covers safety warnings, component identification, start up and operation procedures, maintenance, troubleshooting, specifications, diagrams and other technical details.

Uploaded by

test user3344
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
59 views22 pages

Sinemaster Ig1000

This document provides instructions for operating and maintaining a digital inverter generator. It covers safety warnings, component identification, start up and operation procedures, maintenance, troubleshooting, specifications, diagrams and other technical details.

Uploaded by

test user3344
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 22

R

WUXI KIPOR POWER CO., LTD.

SINEMASTER
DIGITAL INVERTER GENERATOR

I G 10 0 0
I G 10 0 0 s

Downloaded from www.Manualslib.com manuals search engine


Downloaded from www.Manualslib.com manuals search engine
PREFACE
Thank you for purchasing our generators.
This manual covers operation and maintenance of the IG1000, IG1000s
generator.
All information in this publication is based on the latest product information
available at the time of approval for printing.
We reserve the right to make changes at any time without notice and without
incurring any obligation.
No part of this publication may be reproduced without written permission.
This manual should be considered a permanent part of the generator and should
remain with it if it is resold.
Pay special attention to statements preceded by the following words;
Failure to properly follow these precautions can result in
WARNING property damage, serious injury or DEATH!
Read all labels and the owner's manual before operating
this generator.
Operate only in well ventilated areas. Exhaust gas
contains poisonous carbon monoxide, and can be
deadly. Always stop engine before refueling. Wait 5
minutes before restarting.
Check for spilled fuel or leaks. Clean and/or repair
before use.
Keep any sources of ignition away from fuel tank, at all
times.
Indicates a strong possibility of severe personal injury or
WARNING death if instructions are not followed.
Indicates a possibility of personal injury or equipment
CAUTION damage if instructions are not followed.
NOTE: Gives helpful information.
If a problem should arise, or if you have any questions about the generator,
consult an authorized dealer.
Our generators are designed to give safe and
WARNING dependable service if operated according to
instructions. Read and understand the Owner's Manual
before operating the generator. Failure to do so could
result in personal injury or equipment damage.
The illustration may vary according to the type.
38

Downloaded from www.Manualslib.com manuals search engine


14. APPENDIX
CONTENTS
Modified coefficient table
1. Safety Instructions 1 of ambient condition power
The conditions of generator rated output:
2. Safety Label Locations 3 Altitude: 0 m Ambient temperature: 25 Relative humidity: 30%
Ambient modified coefficient: C (Relative humidity 30%)
3. Component Indentificaction 4

4. Pre-operation Check 6 Ambient temperature ( )


Altitude
(m)
5. Starting the Engine 25 30 35 40 45
10
0 1 0.98 0.96 0.93 0.90
6. Generator Use 13
500 0.93 0.91 0.89 0.87 0.84
7. Stopping the Engine 21
1000 0.87 0.85 0.82 0.80 0.78
8. Maintenance 23
2000 0.75 0.73 0.71 0.69 0.66
9. Transporting/Storage 30
3000 0.64 0.62 0.6 0.58 0.56
10. Troubleshooting 32
4000 0.54 0.52 0.5 0.48 0.46

11. Specifications 34
Note: When the relative humidity is 60%, the modified coefficient is C-0.01

12. Electric diagram 35 When the relative humidity is 80%, the modified coefficient is C-0.02
When the relative humidity is 90%, the modified coefficient is C-0.03
13. Light Kit 36 When the relative humidity is 100%, the modified coefficient is C-0.04
Counting example:
14. APPENDIX 37
When the rated power of generator is PN =5KW, altitude is 1000m, ambient

temperature is 35 , relative humidity is 80%, the rated power of generator is:


P=PN (C-0.02) = 5 (0.82-0.02) = 4KW

37

Downloaded from www.Manualslib.com manuals search engine


13. LIGHT KIT 1. SAFETY INSTRUCTIONS

MOUNTING INSTRUCTIONS FOR: IG1000s LIGHT KIT


WARNING Operate carefully and make sure users and others safety.

WARNING
M5 45
Our generators are designed to give safe and depend-
able service if operated according to instructions.
M5 16
Read and understand the Owner's Manual before op-
erating the generator. Failure to do so could result in
personal injury or equipment damage.

M5 45
WARNING
Our IG1000S Light kit is designed specifically for use on IG1000 Generator.
Exhaust gas contains poisonous carbon monoxide.
Tools required: Phillips Screwdriver
Fittings supplied: Never run the generator in an enclosed area.
(1) IG1000 Portable Digital Generator Be sure to provide adequate ventilation.
(2) KGE1000Tsi-05100 Light Kit Assembly
When installed in ventilated protection are to be observed.
(3) KGE1000Tsi-05001a Nut
(4) KGE1000Tsi-05002a threaded Screw
(5) KGE1000Tsi-05003 Left Mount Plate of Light Housing
(6) KGE1000Tsi-05004 Right Mount Plate of Light Housing
(7) Screw M5 45 2PCS
WARNING
(8) Screw M5 16 1PCS
(9) Nut M5 1PC The muffler becomes very hot during operation and
This is where the Light Kit will be mounted, see IG1000s assembly Drawing of the Portable
Digital Generator Light Kit. remains hot for a while after stopping the engine.
(1) Remove the screw from the IG1000 Portable Digital Generator and the screws from the Be careful not to touch the muffler while it is hot.
side of the control plate; Let the engine cool before storing the generator indoors.
(2) Disperse the mount plate of the Light, use screw M5 45 and screw M5 16, then locate
the mount plate of Light Housing on generator. DO NOT TIGHTEN SCREWS. The engine exhaust system will be heated during op-
(3) Use the threaded screw through the Light, left and right mount plate in turn, then lock the eration and remain hot immediately after stopping the
nut.
engine.
(4) After adjusting the turnover angular of Light, tighten the above mentioned of threaded
screw, screw M5 45 and screw M5 16 in turn. To prevent scalding, pay attention to the warning marks
Before energizing the light, be sure to read the Generator Owner's Manual for best operation attached to the generator.
and maintenance information, along with the safety precautions. It is recommended that the
light switch be in the OFF position when starting the generator.

36 1

Downloaded from www.Manualslib.com manuals search engine


To ensure safe operation--
12. ELECTRIC DIAGRAM
WARNING
Gasoline is extremely flammable and explosive under certain conditions.
Refuel in a well ventilated area with the engine stopped.
Parallel output

indicator
Overload
Operating

indicator

Low oil
Keep away from cigarette, smoke and sparks when re-fueling the generator.

indicator
Always refuel in a well-ventilated location.
Wipe up spilled gasoline at once.
Restrict application of generator in high-hazard risk to causing fire area.

WARNING Single phase


receptacle
Connections for standby power to a building's electrical
system must be made by a qualified electrician and must
comply with all applicable laws and electrical codes.
Improper connections can allow electrical current from the
Ignition coil
generator to back feed into the utility lines. Such back feed
may electrocute utility company workers or others who Spark plug

Smart throttle switch


contact the lines during a power outage, and when utility
Low oil switch
power is restored, the generator may explode, burn, or cause
fires in the building's electrical system. Trigger winding

WARNING
Ignition winding
Inverter unit

Always make a pre-operation inspection before you start the engine. You Engine switch
may prevent an accident or equipment damage.
Place the generator at least 1m(3ft) away from buildings or other equipment
during operation.

Rectifier bridge
Operate the generator on a level surface.
If the generator is tiled, fuel spillage may result.
Know how to stop the generator quickly and understand operation of all the
controls. Never permit anyone to operate the generator without proper
instructions.
Main winding

Charge winding

Keep children and pets away from the generator when it is in operation.
Sub winding

DC Receptacle

Keep away from rotating parts while the generator is running.


The generator is a potential source of electrical shocks when misused; do
not operate with wet hands. Stepping motor

Do not operate the generator in rain or snow and do not let it get wet.

2 35

Downloaded from www.Manualslib.com manuals search engine


11. SPECIFICATIONS 2. SAFETY LABEL LOCATIONS
SPECIFICATIONS
Model IG1000/IG1000s These lables warn you of potential hazards that can cause serious injury. Read
Rated frequency (Hz) 50 60 60 the labels and safety notes and precautions described in this manual carefully.
Rated voltage (V) 230 120 240 If a label comes off or becomes hard to read, contact your dealer for a
Rated current (A) 3.9 7.5 3.8 replacement.
Rated rotation speed [r/min] 5500
Rated output (kVA) 0.90
Choke handle
Max. output (kVA) 1.00
DC output
DC voltage 12V-5A
Fuse With Oil level
Phase number Single phase

Engine
Model Type KG144
Type Single cylinder,air-cooled, 4 stroke, OHV, gasoline engine
Displacement (Bore Stroke) 53.5ml (43.5 36mm)
Compression ratio 8.5:1 Engine switch
Rated power [kW/(r/min)] 1.2/5500
Rated rotation speed [rpm] 5500
Ignition system T.C.I
Spark plug UR5/A7RTC
Starting system Recoil starter
Fuel Automotive unleaded gasoline
Fuel consumption (g/kW.h) 420
Lube oil CD grade or SAE 10W-30 15W-40

Fuel tank capacity (L) 2.6


Model Hot caution
Continuous running time (hr) (at rated output) 5.0
Noise level (zero load-full load) [dB(A)/7m] 54-59 *
Safety caution
IG1000: 460X248X395(18.11 9.76 15.55)
Overall dimension (L W H) [mm(in)]
IG1000s: 605X250X400(23.82 9.84 15.75)
Dry weight [kg(lbs)] IG1000: 14(30.8) IG1000s: 15.5(34.1)
*The declared values shall consider uncertainties due to production variation and measurement
procedures.
34 3

Downloaded from www.Manualslib.com manuals search engine


Appliance does not operate:
3.COMPONENT IDENTIFICATION
Is the output indicator light ON?

YES NO

Fuel cap lever Is the overload NO Take the generator to an


indicator light ON? authorized dealer.
Choke lever
YES

Check the electrical appli- NO


Control panel Take the generator to an
ance or equipment for any
Left side main- authorized dealer.
defects.
tenance cover

Starter grip Replace the electrical


appliance or equipment
YES
Take the electrical appli-
Engine switch
ance or equipment to an
Air intake hole electrical shop for repair

No electricity at the DC receptacle:


YES
Is the DC circuit fuse burnt out? Replace the fuse.

Muffler

Spark plug main- NO Take the generator to an


tenance cover
authorized dealer.

Air exhaust hole

4 33

Downloaded from www.Manualslib.com manuals search engine


Control panel
10.TROUBLESHOOTING
Smart Throttle switch Output indicator light

DC receptacle
When the engine will not start: Overload indicator light
NO
Is there fuel in the tank? Refill the fuel tank.

YES
Low oil alarm indicator light
NO Ground terminal
Is the engine switch on? Turn the engine switch on.

YES AC receptacle
NO
Is there enough oil in the engine? Add the recommended oil. Parallel receptacle

YES Parallel receptacle


NO Still no Take the generator to The parallel cabinet can be connected with the parallel socket when the
Is there a spark from Replace the generator set needs a increasing of parallel output power.
spark an authorized dealer.
the spark plug? spark plug.
SMART throttle
Engine speed is kept at idle automatically when the electrical appliance is
To check: disconnected and it returns to the proper speed to power of the electrical load
WARNING when elec-trical appliance is connected. This position is recommended to
1)Remove the spark plug cap and clean
Be sure there is no spilled any dirt from around the spark plug. minimize the fuel consumption while in operation.
fuel around the spark pulg. 2)Remove the spark plug and install the
Spilled fuel may ignite. NOTE
spark plug in the plug cap.
3)Set the plug side electrode on the Smart throttle system does not operate effectively if the electrical appliance
requires the big electric power.
cylinder head to ground.
When high electrical loads are connected simultaneously turn the smart
4)Pull the recoil starter, sparks should jump throttle switch to the OFF position to re-duce voltage changes.
Is the fuel reaching the
carburetor. across the gap. In DC charging, turn the smart throttle switch to the OFF position.

OFF:
Note: Smart throttle system does not operate. Engine speed is kept at thigh-
speed lever..
If the engine still does not
start, take the generator to Smart throttle
an authorized dealer. switch

32 5

Downloaded from www.Manualslib.com manuals search engine


a. Drain all gasoline from the fuel tank into an approved gasoline container.
4.PRE-OPERATION CHECK b. Turn the engine switch ON, and loosen the carburetor drain screw and drain
the gasoline from the carburetor into a suitable container.
c. With the drain screw loosened remove the spark plug cap, and pull the starter
CAUTION grip 3 to 4 times to drain the gasoline from the fuel pump.
Be sure to check the generator on a level surface with the engine stopped. d. Turn the engine switch to the OFF position, and tighten the drain screw
1. Check the engine oil level. securely.
e. Reinstall the spark plug cap on the spark plug
CAUTION 3. Change the engine oil.
Using nondetergent oil or 2-stroke engine oil could shorten the engine's 4. Remove the spark plug and pour about a tablespoon of clean engine oil into
service life. the cylinder.
Use a high-detergent, premium quality 4-stroke engine oil, certified to meet Crank the engine several revolutions to distribute the oil, then reinstall the spark
or exceed U.S. automobile manufacturer's requirements for API Service plug.
Classification SE/SF. 5.Slowly pull the starter grip until resistance is felt. At this point, the piston is
Select the appropriate viscosity for the average temperature in your area. coming up on its compression stroke and both the intake and exhaust valves are
SAE Viscosity Grades closed. Storing the engine in this position wil help to protect it from internal
corrosion.
Ambient temperature Engine oil type
-25 -30 10W-30
-15 -40 15W-40
Starter grip
CAUTION
Store and use the oil carefully in order to prevent dust or dirty flowing into
the oil. If oil is overfilled, wipe it up at once.
Never mix different kinds of oil.

Loosen the cover screw and remove the left side maintenance cover.
Remove the oil filler cap, and wipe the dipstick with a clean rag. Check the oil level
by inserting the dipstick in the filler hole without screwing it in.
If the oil level is below the end of the dipstick, refill the recommended oil up to the
top of the oil filler neck.

NOTE
Running the engine with insufficient oil can cause serious engine damage.
The Low Oil Alarm System will automatically stop the engine before the oil
levelfalls below the safe limit. However, to avoid the inconvenience of an
unexpected shutdown, it is still advisable to visually inspect the oil level
regularly.

6 31

Downloaded from www.Manualslib.com manuals search engine


9.TRANSPORTING/STORAGE
Upper lever

To prevent fuel spillage when transporting or during temporary storage, the genera- Upper limit
tor should be secured upright in its normal operating position, with the engine Oil rule
switch OFF. Turn the cap lever fully counterclockwise to the "OFF" position.

WARNING
Oil filler hole Lower limit
When transporting the generator:
Do not overfill the tank (there should be no fuel in the filler neck)
Do not operate the generator while it is on a vehicle.
Take the generator off the vehicle and use it in a well ventilated place. 2.Check the fuel level.
Avoid a place exposed to direct sunlight when putting the generator on a Use automotive gasoline (Unleaded or lowleaded is preferred to minimize
vehicle. If the generator is left in an enclosed vehicle for many hours, high combustion chamber deposits).
temperature in-side the vehicle could cause fuel to vaporize resulting in a If the fuel level is low, refuel the fuel tank until the level as specified.
possible explosion. Never use an oil/gasoline mixture or dirty gasoline.
Do not drive on a rough road for an extended period with the generator on board,
Avoid getting dirt, dust or water in the fuel tank.
if you must transport the generator on a rough road, drain the fuel from the gen-
After refueling, tighten the oil rule seurely.
erator beforehand.

Before storing the unit for an extended period:


1. Be sure the storage area is free of excessive humidity and dust.
2. Drain out the fuel completely.

WARNING WARNING

Gasoline is extremely flammable and explosive under certain conditions. Gasoline is extremely flammable and is explosive und-er certain conditions.
Do not smoke or allow flames or sparks in the area. Refuel in a well-ventilated area with the engine stopped.
Do not smoke or alow flames or sparks in the area where the engine is
refueled or where gasoline is stored.
Do not overfill the fuel tank (there should be no fuel above the upper limit
mark). After refueling, make sure the tank cap is closed properly and securely.
Be careful not to spill fuel when refueling. Spilled fuel or fuel vapor may ignite,
if any fuel is spilled, make sure the area is dry before starting the engine.
Avoid repeated or prolonged contact with skin or breath-ing of vapor, KEEP
OUT OF REACH OF CHILDREN.

Drain screw

30 7

Downloaded from www.Manualslib.com manuals search engine


Fuel tank capacity:2.6L 3.Use a brush to remove carbon deposits from the spark arrester screen.

Fuel filler cap Open

Oil surface

Spark arrester

Gasoline containing alcohol


If you decide to use a generator containing alcohol (gasohol), be sure it's octane
rating is at least as high as that recommended by us. There are two types of 4.Check the muffler gasket; replace if damaged. Reinstall the muffler gasket, the
gasohol: one containing ethanol, and the other containing methanol. Do not use spark arrester, the muffler and the muffler protector in the reverse order of removal.
gasohol that contains more than 10% ethanol. Do not use gasoline containing
methanol (methyl or wood alcohol) that does not also contain cosolvents and
corrosion inhibitors for methanol. Never use gasoline containing more than 5%
methanol, even if it has cosolvents and corrosion inhibitors.

NOTE

nFuel system damage or engine performance problems resulting from the use
of fuel that contain alcohol is not covered under the warranty. We cannot
endorse the use of fuels containing methanol since evidence of their
suitability is as yet incomplete.
nBefore buying fuel from an unfamiliar station, try to find out if the fuel
contains alcohol. If it does, confirm the type and percentage of alcohol used.
If you notice any undesirable operating symptoms while using a gasoline that
contains alcohol, or one that you think contains alcohol, replace it by a
gasoline that you know does not contain alcohol.

8 29

Downloaded from www.Manualslib.com manuals search engine


4.SPARK ARRESTER MAINTENANCE(Equipped type only) 3.Check the air cleaner.
Check the air cleaner element to be sure it is clean and in good condition.
WARNING Loosen the cover screw and remove the left side maintenance cover. Press the
latch tab on the top of the air cleaner body, remove the air cleaner cover, check
If the generator has been running, the muffler will be very hot. Allow it to cool
the element. Clean or replace the element if necessary.
before proceeding.

CAUTION
CAUTION Never run the engine without the air cleaner. Rapid engine wear will result
The spark arrester must be serviced every 100 hours to maintain its from contaminants, such as dust and dirt, being drawn through the
efficiency. carburetor, into the engine.

1.Remove the four M5 screws, and remove the muffler protector.

Maintenance cover
Muffler protector
Screw

M5 screw

2.Remove the there M6 bolts, and remove the muffler, the spark arrester and the
muffler gasket
Latch tab

Muffler gasket
Air cleaner element
Muffler
Air cleaner cover
Spark catcher

Lower tab
M6 Bolts

28 9

Downloaded from www.Manualslib.com manuals search engine


5.Visually inspect the spark plug. Discard it if the insulator is cracked or chipped.
5.STARTING THE ENGINE Clean the spark plug with a wire brush if it is to be reused.
6.Measure the plug gap with a feeler gauge.
The gap should be 0.6-0.7mm(0.024-0.028in). Correct as necessary by carefully
NOTE bending the side electrode.
Before starting the engine, disconnect the load from the DC terminals.
When starting the generator after adding fuel for the first time or after long term
storage, or after running out of fuel, turn the fuel valve lever to the '' ON''
position, then wait for 10 to 20 seconds before starting the engine.

1.Turn the fuel cap lever fully clockwise to the ON position.

NOTE
Turn the fuel cap vent lever to the OFF position when transporting generator.

Fuel cap lever

CAUTION
The spark plug must be securely tightened.An improp-erly tightened plug
can become very hot and possibly damage the generator. Never use a
spark plug with an improper heat range.
ON

7.Install the spark plug carefully, by hand, to avoid cross-threading.


8.After a new spark plug has been seated by hand, it should be tightened 1/2 turn
with a wrench to compress its washer.
2. Turn the engine switch to the On position.
If a used plug is being reinstalled, it should only require 1/8 to 1/4 turn after being
.
seated.
9.Reinstall the spark plug cap on the spark plug securely.
ON
10.Close the left maintenance cover.
OFF

ON

Engine switch

10 27

Downloaded from www.Manualslib.com manuals search engine


3.SPARK PLUG SERVICE 3.Move the choke lever to the START position.

RECOMMENTED SPARK PLUG: UR5/A7RTC


To ensure proper engine operation, the spark plug must be properly gapped and NOTE
free of deposits.
Do not use the choke when the engine is warm or the air temperature is
1.Remove the spark plug maintenance cover.
high.

Choke lever Run


Run

4.Pull the starter grip until resistance is felt, then pull the starter grip briskly
toward the arrow as shown below.

CAUTION
2.Remove the spark plug cap. Do not allow the starter grip to snap back, return it slowly by hand.
3.Clean any dirt from around the spark plug base.
4.Use the wrench to remove the spark plug.

Starter grip

26 11

Downloaded from www.Manualslib.com manuals search engine


5. Move the choke lever to the RUN position after the engine warms up. 2.AIR CLEANER SERVICE
A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor
malfunction,service the air cleaner regularly. Service more frequently when
Choke lever
operat-ing the generator in extremely dusty areas.

WARNING
Run
Do not use gasoline or low flash point solvents for cleaning. They are
flammable and explosive under certain conditions.
Run

CAUTION
Do not run generator without air cleaner for causing engine accelerated wear.
CAUTION
If the engine stops and will not restart, check the engine oil level before a.Loosen the cover screw and remove the left side maintenance cover.
b.Press the latch tab on the top of the air cleaner body, and remove the air cleaner
troubleshooting in other areas.
cover.
c.Wash the element in a non-flammable or high flash point solvent and dry it
High altitude operation thoroughly.
At high altitude, the standard carburetor air-fuel mixture will be excessively rich. d.Soak the element in clean engine oil and squeeze out the excess oil.
Performance will decrease, and fuel consumption will increase. e.Reinstall the air cleaner element and the cover.
f.Reinstall the left side maintenance cover and tighten the cover screw securely.
High altitude performance can be improved by installing a smaller diameter main
fuel jet in the carburetor and readjusting the pilot screws. If you always operate
Maintenance cover Latch tab
the generator at altitudes higher than 1,500m (5,000 feet) above sea level, have
Element
your authorized dealer perform these carburetor modifications. Screw Air cleaner cover

Even with suitable carburetor jetting, engine horsepower will decrease


approximately 3.5% for each 305m (1,000 feet) increase in altitude. The affect of
altitude on the horsepower will be greater than this if no carburetor modification is Lower tab

made.
Cleaning Wring out and dry Dipping into oil Wring out oil

CAUTION
Operation of the generator at an altitude lower than the carburetor is jetted
for may result in reduced performance, overheating, and serious engine
damage caused by an excessively lean air/fuel mixture.

12 25

Downloaded from www.Manualslib.com manuals search engine


1.CHANGING OIL
Drain the oil while the engine is still warm to assure rapid and complete draining. 6.GENERATOR USE

CAUTION
Make sure to turn the engine switch and the fuel cap lever OFF before WARNING
draining.
1.Loosen the cover screw and remove the left side maintenance cover. To prevent electrical shock from faulty appliances, the generator should be
2.Remove the oil filler cap. grounded.Connect a length of heavy wire between the generator's ground
3.Drain dirty oil into a container thoroughly. terminal and an external ground source.
4.Refill with the recommended oil, and check the oil level. Connections for standby power to a building's electrical system must be
5.Reinstall the left side maintenance cover and tighten the cover screw securely. made by a qualified electrician and must comply with all applicable laws
Engine oil capacity:0.25L and electrical codes. Improper connections can allow electrical current from
the generator to backfeed into the utility lines. Such backfeed may
electrocute utility company workers or others who contact the lines during a
Maintenance cover
power outage, and when utility power is restored,the generator may
Screw
explode, burn, or cause fires in the building's electrical system.
se
Fu

CAUTION
se
Fu

Maximum power would be available for the first 30 minutes.


For continuous operation,do not exceed the rated power. In either case, the
Upper level total wattage of all appliances con-nected must be considered.
Do not exceed the current limit specified for any one receptacle.
Oil filler cap Do not connect the generator to a household circuit. This could cause the
damage to the generator or to electrical appliances in the house.
Do not modify or use the generator for other purposes than it is intended
for. Also observe the following when using the generator.
Oil filler cap Do not connect an extension to the exhaust pipe.
When an extension cable is required,be sure to use a tough rubber
Wash your hands with soap and water after handing used oil. sheathed flexible cable. (IEC245DV equivalent)
2
Limit length of extension cables; less than60 m for cables if 2.5mm and
NOTE less than100m for cabes of 4 mm2.
Please dispose of used motor oil in a manner that is compatible with the Keep the generator away from other electric cables or wires such as
environment. We suggest you take it in a sealed container to your local commercial power supply lines.
service station for reclamation. Do not throw it in the trash or pour it on the
ground.

24 13

Downloaded from www.Manualslib.com manuals search engine


NOTE 8.MAINTENANCE
The DC receptacle can be used while the AC power is in use. If you use both
at the same time, be sure not to exceed the total power for AC and DC. The purpose of the maintenance and adjustment schedule is to keep the generator
Electrical equipment (including electrical lines and plugs connection) could not in the best operating condition.
be defective.
WARNING
AC applications Shut off the engine before performing any maintenance. If the engine must be
1.Start the engine and make sure the output indicator light (green) comes on. run, make sure the area is well ventilated. The exhaust contains poisonous
2.Confirm that the appliance to be used is switched off, and plug in the appliance. carbon monoxide gas.

Output indicator CAUTION


light (green)
Use genuine our parts or their equivalent. The use of replacement parts which
Overload indicator
are not of equivalent quality may damage the generator.
light (red)

Maintenance Schedule

REGULAR SERVICE PE-


Plug RIOD (1) Perform at every FIRST EVERY 3 EVERY 6 EVERY
EACH
indicated month or operating MONTH MONTHS MONTHS YEAR
hour interval, whichever oc- USE
curs first. OR OR OR OR
10HRS 50HRS 100 HRS 300 HRS
ITEM
Check
Engine oil
Change
Check
CAUTION Air cleaner
Clean (2)
Be sure that all appliances are in good working order before connecting them
Spark plug Clean-adjust
to the generator. If an appli-ance begins to operate abnormally, becomes
Spark arrester Clean
sluggish, or stops suddenly, turn off the generator engine switch immediately.
Then disconnect the appliance, and examine it for signs of malfunction. Fuel sediment cup
Valve clearance Check-adjust (3)
Fuel tank and strainer Clean (3)
3. In order to acquire both the best effect and the maximum service life of the
Fuel line Check Every 2 years (Replace if necessary)(3)
generator. Usually, the new generator should run 20 hours under 50% load, the
generator may reach the best performance. NOTE: (1) Log hours of operation to determine proper maintenance.
(2) Service more frequently when used in dusty areas.
(3)These items should be serviced by an authorized dealer, unless the owner
has the proper tools and is mechanically proficient. See the shop Manual.

14 23

Downloaded from www.Manualslib.com manuals search engine


3.Turn the cap lever fully counterclockwise to the "OFF"position. Output and Overload Indicators Oil Level Indicator
The output indicator light(green)will remain ON during normal operating
conditions.
If the generator is overloaded(in excess of 1.0kVA), or if there is a short in the
con-nected appliance, the output indicator light(green) will go OFF, the overload
indica-tor light(red) will go ON and current to the connected appliance wil be shut
off.
Stop the engine if the overload indicator light (red) comes ON and investigate the
overload source.
Oil Level Indicator
If the oil level indicator light comes on, please check.

NOTE
Before connecting an appliance to the generator, check that it is in good order,
and that its electrical rating does not exceed that of the generator. Then
connect the power cord of the appliance, and start the engine.

CAUTION
Be sure the fuel cap lever, choke and the engine switch are "OFF" when
NOTE
stopping, transporting and/or storing the generator. When an electric motor is started, both the overload indicator light(red) and
the output indicator light (green) may go on simultaneously. This is normal if
the over- load indicator light(red) goes off after about four (4) seconds. If the
overload indicator light (red) stays on, consult your generator dealer.

Output indicator
light (green)

Overload indicator
light (red)

Low oil alarm indicator


light (red)

22 15

Downloaded from www.Manualslib.com manuals search engine


1.Connect the ground terminal.
7.STOPPING THE ENGINE

To stop the engine in an emergency, turn the engine switch to the OFF position.

IN NORMAL USE:
1.Switch off the connected equipment and pull the inserted plug.
Ground terminal

2. Start each engine according to "STARTING THE ENGINE".


When the output indicator light(green)does not light and the overload indicator
light (red) lights instead,set the engine switch to STOP,stop the engine at once
and then start the engine again. Plug
3. Confirm that the equipment to be used is switched off, and insert the plug of
the equipment to be used into the AC receptacle.

CAUTION
Confirm that the use equipment to be connected is switched off. When the 2.Turn the engine switch to the OFF position.
equipment to be used is switched on, it will operate suddenly, and injuries or
accidents may be caused.

ON

Output indicator OFF


light (green) Overload indicator
light (red)

OFF
Engine switch

16 21

Downloaded from www.Manualslib.com manuals search engine


Low oil alarm system 4.Switch on the equipment to be used.
The Low oil alarm system is designed to prevent engine damage caused by an In case of overload operation or when trouble occurs for the equipment being
insufficient amount of oil in the crankcase. Before the oil level in the crankcase used, the output indicator light(green) will go out, the overload indicator light(red)
falls below a safe limit, the Low oil alarm system will automatically shut down the will light continuously, and no power will be put out.
engine (the engine switch will remain in the ON position).
At this time, the engine will not stop, so that the engine must be stopped by
If the low oil alarm system shuts down the engine, the low oil alarm indicator setting the respective engine switch to STOP.
light(red) will come on when you operate the starter, and the engine will not run.
If this occurs, add engine oil.
CAUTION
When equipment requiring a large starting power, like a motor etc., is used,
the overload indicator light (red) and the output indicator light(green)may
light together for a short time (about 4 sec), but this is no abnormality. After
start of the equipment, the overload indicator light (red) will go out and the
output indicator light(green) will stay lit.

The DC receptacle may be used for charging 12 volt automotive-type batteries


only, the zero load voltage is 15V-30V.
Low oil alarm indicator
light (red) DC output will vary according to the position of the smart throttle switch.

NOTE
In DC operation, turn the Smart throttle switch to the OFF position.

20 17

Downloaded from www.Manualslib.com manuals search engine


1.Connect the charging cables to the DC receptacle of the generator and then to
the battery terminals.
WARNING
The battery gives off explosive gases; keep sparks, flames and cigarettes
away. Provide adequate venti-lation when charging.
The battery contains sulfuric acid (electrolyte). Con-tact with skin or eyes
may cause severe burns. Wear protective clothing and a face shield.
- If electrolyte gets on your skin, flush with water.
Charging cable
- If electrolyte gets in your eyes, flush with water for at Least 15 minutes
and call a physician.
Electrolyte is poisonous.
- If swallowed, drink large quantites of water or milk and follow with milk of
magnecia or vegetable oil and call a physician.
KEEP OUT OF REACH OF CHILDREN.

2.Start the engine.

CAUTION

WARNING The DC receptacle may be used while the AC power is in use.


An overload DC circuit may burnt out the DC circuit fuse. If this happens,
To prevent the possibility of creating a spark near the battery, connect remove the load and change with a same kind after stopping.
charging cable first to the generator, then to the battery. Disconnect cable
first at the battery.
Before connecting charging cables to a battery that is installed in a vehicle,
disconnect the vehicles grounded battery cable. Reconnect the vehicle's
grounded bat-tery cable after the charging cables are removed. This
procedure will prevent the possibility of a short circuit and sparks if you
make accdental contact between a battery terminal and the vehicle's frame
or body.

Fuse

CAUTION
Do not attempt to start an automobile engine with the generator still ON
DC circuit protector
connected to the battery. The generator may be damaged. Connect the
positive battery terminal to the positive charging cord. Do not reverse the
charging cables, or serious damage to the generator and/or battery may
occur.
18 19

Downloaded from www.Manualslib.com manuals search engine

You might also like