Sinemaster Ig1000
Sinemaster Ig1000
SINEMASTER
DIGITAL INVERTER GENERATOR
I G 10 0 0
I G 10 0 0 s
11. Specifications 34
Note: When the relative humidity is 60%, the modified coefficient is C-0.01
12. Electric diagram 35 When the relative humidity is 80%, the modified coefficient is C-0.02
When the relative humidity is 90%, the modified coefficient is C-0.03
13. Light Kit 36 When the relative humidity is 100%, the modified coefficient is C-0.04
Counting example:
14. APPENDIX 37
When the rated power of generator is PN =5KW, altitude is 1000m, ambient
37
WARNING
M5 45
Our generators are designed to give safe and depend-
able service if operated according to instructions.
M5 16
Read and understand the Owner's Manual before op-
erating the generator. Failure to do so could result in
personal injury or equipment damage.
M5 45
WARNING
Our IG1000S Light kit is designed specifically for use on IG1000 Generator.
Exhaust gas contains poisonous carbon monoxide.
Tools required: Phillips Screwdriver
Fittings supplied: Never run the generator in an enclosed area.
(1) IG1000 Portable Digital Generator Be sure to provide adequate ventilation.
(2) KGE1000Tsi-05100 Light Kit Assembly
When installed in ventilated protection are to be observed.
(3) KGE1000Tsi-05001a Nut
(4) KGE1000Tsi-05002a threaded Screw
(5) KGE1000Tsi-05003 Left Mount Plate of Light Housing
(6) KGE1000Tsi-05004 Right Mount Plate of Light Housing
(7) Screw M5 45 2PCS
WARNING
(8) Screw M5 16 1PCS
(9) Nut M5 1PC The muffler becomes very hot during operation and
This is where the Light Kit will be mounted, see IG1000s assembly Drawing of the Portable
Digital Generator Light Kit. remains hot for a while after stopping the engine.
(1) Remove the screw from the IG1000 Portable Digital Generator and the screws from the Be careful not to touch the muffler while it is hot.
side of the control plate; Let the engine cool before storing the generator indoors.
(2) Disperse the mount plate of the Light, use screw M5 45 and screw M5 16, then locate
the mount plate of Light Housing on generator. DO NOT TIGHTEN SCREWS. The engine exhaust system will be heated during op-
(3) Use the threaded screw through the Light, left and right mount plate in turn, then lock the eration and remain hot immediately after stopping the
nut.
engine.
(4) After adjusting the turnover angular of Light, tighten the above mentioned of threaded
screw, screw M5 45 and screw M5 16 in turn. To prevent scalding, pay attention to the warning marks
Before energizing the light, be sure to read the Generator Owner's Manual for best operation attached to the generator.
and maintenance information, along with the safety precautions. It is recommended that the
light switch be in the OFF position when starting the generator.
36 1
indicator
Overload
Operating
indicator
Low oil
Keep away from cigarette, smoke and sparks when re-fueling the generator.
indicator
Always refuel in a well-ventilated location.
Wipe up spilled gasoline at once.
Restrict application of generator in high-hazard risk to causing fire area.
WARNING
Ignition winding
Inverter unit
Always make a pre-operation inspection before you start the engine. You Engine switch
may prevent an accident or equipment damage.
Place the generator at least 1m(3ft) away from buildings or other equipment
during operation.
Rectifier bridge
Operate the generator on a level surface.
If the generator is tiled, fuel spillage may result.
Know how to stop the generator quickly and understand operation of all the
controls. Never permit anyone to operate the generator without proper
instructions.
Main winding
Charge winding
Keep children and pets away from the generator when it is in operation.
Sub winding
DC Receptacle
Do not operate the generator in rain or snow and do not let it get wet.
2 35
Engine
Model Type KG144
Type Single cylinder,air-cooled, 4 stroke, OHV, gasoline engine
Displacement (Bore Stroke) 53.5ml (43.5 36mm)
Compression ratio 8.5:1 Engine switch
Rated power [kW/(r/min)] 1.2/5500
Rated rotation speed [rpm] 5500
Ignition system T.C.I
Spark plug UR5/A7RTC
Starting system Recoil starter
Fuel Automotive unleaded gasoline
Fuel consumption (g/kW.h) 420
Lube oil CD grade or SAE 10W-30 15W-40
YES NO
Muffler
4 33
DC receptacle
When the engine will not start: Overload indicator light
NO
Is there fuel in the tank? Refill the fuel tank.
YES
Low oil alarm indicator light
NO Ground terminal
Is the engine switch on? Turn the engine switch on.
YES AC receptacle
NO
Is there enough oil in the engine? Add the recommended oil. Parallel receptacle
OFF:
Note: Smart throttle system does not operate. Engine speed is kept at thigh-
speed lever..
If the engine still does not
start, take the generator to Smart throttle
an authorized dealer. switch
32 5
Loosen the cover screw and remove the left side maintenance cover.
Remove the oil filler cap, and wipe the dipstick with a clean rag. Check the oil level
by inserting the dipstick in the filler hole without screwing it in.
If the oil level is below the end of the dipstick, refill the recommended oil up to the
top of the oil filler neck.
NOTE
Running the engine with insufficient oil can cause serious engine damage.
The Low Oil Alarm System will automatically stop the engine before the oil
levelfalls below the safe limit. However, to avoid the inconvenience of an
unexpected shutdown, it is still advisable to visually inspect the oil level
regularly.
6 31
To prevent fuel spillage when transporting or during temporary storage, the genera- Upper limit
tor should be secured upright in its normal operating position, with the engine Oil rule
switch OFF. Turn the cap lever fully counterclockwise to the "OFF" position.
WARNING
Oil filler hole Lower limit
When transporting the generator:
Do not overfill the tank (there should be no fuel in the filler neck)
Do not operate the generator while it is on a vehicle.
Take the generator off the vehicle and use it in a well ventilated place. 2.Check the fuel level.
Avoid a place exposed to direct sunlight when putting the generator on a Use automotive gasoline (Unleaded or lowleaded is preferred to minimize
vehicle. If the generator is left in an enclosed vehicle for many hours, high combustion chamber deposits).
temperature in-side the vehicle could cause fuel to vaporize resulting in a If the fuel level is low, refuel the fuel tank until the level as specified.
possible explosion. Never use an oil/gasoline mixture or dirty gasoline.
Do not drive on a rough road for an extended period with the generator on board,
Avoid getting dirt, dust or water in the fuel tank.
if you must transport the generator on a rough road, drain the fuel from the gen-
After refueling, tighten the oil rule seurely.
erator beforehand.
WARNING WARNING
Gasoline is extremely flammable and explosive under certain conditions. Gasoline is extremely flammable and is explosive und-er certain conditions.
Do not smoke or allow flames or sparks in the area. Refuel in a well-ventilated area with the engine stopped.
Do not smoke or alow flames or sparks in the area where the engine is
refueled or where gasoline is stored.
Do not overfill the fuel tank (there should be no fuel above the upper limit
mark). After refueling, make sure the tank cap is closed properly and securely.
Be careful not to spill fuel when refueling. Spilled fuel or fuel vapor may ignite,
if any fuel is spilled, make sure the area is dry before starting the engine.
Avoid repeated or prolonged contact with skin or breath-ing of vapor, KEEP
OUT OF REACH OF CHILDREN.
Drain screw
30 7
Oil surface
Spark arrester
NOTE
nFuel system damage or engine performance problems resulting from the use
of fuel that contain alcohol is not covered under the warranty. We cannot
endorse the use of fuels containing methanol since evidence of their
suitability is as yet incomplete.
nBefore buying fuel from an unfamiliar station, try to find out if the fuel
contains alcohol. If it does, confirm the type and percentage of alcohol used.
If you notice any undesirable operating symptoms while using a gasoline that
contains alcohol, or one that you think contains alcohol, replace it by a
gasoline that you know does not contain alcohol.
8 29
CAUTION
CAUTION Never run the engine without the air cleaner. Rapid engine wear will result
The spark arrester must be serviced every 100 hours to maintain its from contaminants, such as dust and dirt, being drawn through the
efficiency. carburetor, into the engine.
Maintenance cover
Muffler protector
Screw
M5 screw
2.Remove the there M6 bolts, and remove the muffler, the spark arrester and the
muffler gasket
Latch tab
Muffler gasket
Air cleaner element
Muffler
Air cleaner cover
Spark catcher
Lower tab
M6 Bolts
28 9
NOTE
Turn the fuel cap vent lever to the OFF position when transporting generator.
CAUTION
The spark plug must be securely tightened.An improp-erly tightened plug
can become very hot and possibly damage the generator. Never use a
spark plug with an improper heat range.
ON
ON
Engine switch
10 27
4.Pull the starter grip until resistance is felt, then pull the starter grip briskly
toward the arrow as shown below.
CAUTION
2.Remove the spark plug cap. Do not allow the starter grip to snap back, return it slowly by hand.
3.Clean any dirt from around the spark plug base.
4.Use the wrench to remove the spark plug.
Starter grip
26 11
WARNING
Run
Do not use gasoline or low flash point solvents for cleaning. They are
flammable and explosive under certain conditions.
Run
CAUTION
Do not run generator without air cleaner for causing engine accelerated wear.
CAUTION
If the engine stops and will not restart, check the engine oil level before a.Loosen the cover screw and remove the left side maintenance cover.
b.Press the latch tab on the top of the air cleaner body, and remove the air cleaner
troubleshooting in other areas.
cover.
c.Wash the element in a non-flammable or high flash point solvent and dry it
High altitude operation thoroughly.
At high altitude, the standard carburetor air-fuel mixture will be excessively rich. d.Soak the element in clean engine oil and squeeze out the excess oil.
Performance will decrease, and fuel consumption will increase. e.Reinstall the air cleaner element and the cover.
f.Reinstall the left side maintenance cover and tighten the cover screw securely.
High altitude performance can be improved by installing a smaller diameter main
fuel jet in the carburetor and readjusting the pilot screws. If you always operate
Maintenance cover Latch tab
the generator at altitudes higher than 1,500m (5,000 feet) above sea level, have
Element
your authorized dealer perform these carburetor modifications. Screw Air cleaner cover
made.
Cleaning Wring out and dry Dipping into oil Wring out oil
CAUTION
Operation of the generator at an altitude lower than the carburetor is jetted
for may result in reduced performance, overheating, and serious engine
damage caused by an excessively lean air/fuel mixture.
12 25
CAUTION
Make sure to turn the engine switch and the fuel cap lever OFF before WARNING
draining.
1.Loosen the cover screw and remove the left side maintenance cover. To prevent electrical shock from faulty appliances, the generator should be
2.Remove the oil filler cap. grounded.Connect a length of heavy wire between the generator's ground
3.Drain dirty oil into a container thoroughly. terminal and an external ground source.
4.Refill with the recommended oil, and check the oil level. Connections for standby power to a building's electrical system must be
5.Reinstall the left side maintenance cover and tighten the cover screw securely. made by a qualified electrician and must comply with all applicable laws
Engine oil capacity:0.25L and electrical codes. Improper connections can allow electrical current from
the generator to backfeed into the utility lines. Such backfeed may
electrocute utility company workers or others who contact the lines during a
Maintenance cover
power outage, and when utility power is restored,the generator may
Screw
explode, burn, or cause fires in the building's electrical system.
se
Fu
CAUTION
se
Fu
24 13
Maintenance Schedule
14 23
NOTE
Before connecting an appliance to the generator, check that it is in good order,
and that its electrical rating does not exceed that of the generator. Then
connect the power cord of the appliance, and start the engine.
CAUTION
Be sure the fuel cap lever, choke and the engine switch are "OFF" when
NOTE
stopping, transporting and/or storing the generator. When an electric motor is started, both the overload indicator light(red) and
the output indicator light (green) may go on simultaneously. This is normal if
the over- load indicator light(red) goes off after about four (4) seconds. If the
overload indicator light (red) stays on, consult your generator dealer.
Output indicator
light (green)
Overload indicator
light (red)
22 15
To stop the engine in an emergency, turn the engine switch to the OFF position.
IN NORMAL USE:
1.Switch off the connected equipment and pull the inserted plug.
Ground terminal
CAUTION
Confirm that the use equipment to be connected is switched off. When the 2.Turn the engine switch to the OFF position.
equipment to be used is switched on, it will operate suddenly, and injuries or
accidents may be caused.
ON
OFF
Engine switch
16 21
NOTE
In DC operation, turn the Smart throttle switch to the OFF position.
20 17
CAUTION
Fuse
CAUTION
Do not attempt to start an automobile engine with the generator still ON
DC circuit protector
connected to the battery. The generator may be damaged. Connect the
positive battery terminal to the positive charging cord. Do not reverse the
charging cables, or serious damage to the generator and/or battery may
occur.
18 19