The document provides specifications for leverless limit switches, including their size, sensing distance, temperature rating, contacts, and housing materials. It describes the seven-group numbering system used to select the correct switch model based on its contact arrangement, sensing characteristics, outlet position, enclosure material, approvals/options, and termination options.

Uploaded by

majin buu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
24 views1 page

GO Switch

The document provides specifications for leverless limit switches, including their size, sensing distance, temperature rating, contacts, and housing materials. It describes the seven-group numbering system used to select the correct switch model based on its contact arrangement, sensing characteristics, outlet position, enclosure material, approvals/options, and termination options.

Uploaded by

majin buu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

LEVERLESS LIMIT SWITCHES

Standard Model
Specifications
Size: 1-1/2 " square x 4-9/16 " overall. Add 1/2" for Rating: 1250 watts @ 120, 240, 480 or 600 High temperature 445oF.(229oC)
bottom conduit outlet. VAC. Latching models
Sensing Distance: Approx. 3/8" side sensing with Housing: Brass or stainless steel. Brass or stainless steel housing
ferrous target (Up to 3-3/16" with magnetic target) Conduit Outlet: 1/2" - 14 NPT. Epoxy coating for added corrosion
Differential: Approx. 5/16". Repeatability: 0.002" (0.05mm) typical resistance
Response Time: 8 milliseconds. Approvals: UL, CSA, FM, MSHA and SAA. Potted-in lead wires
Temperature Rating: -40oF. (-40oC) to 221oF. (NOTE: Approvals may vary, depending on Potted-in Cable
(105oC). configuration and options.) Quick disconnect
Contacts: Single Pole, Double Throw, Form C Options: Five conduit hub locations
Silver cadmium oxide, gold flashed.
How To Select The Correct 10 Series GO Switch
GO- Switches use a seven-group alphanumeric identification system to make it easy to order the right switch.
Examples: Model 11-11110-00 Model 11-11320-00 Model 11-11510-00
SPDT, 3/8" (9.53mm), SPDT, 3/8" (9.53mm), SPDT, 3/8" (9.53mm),
side sensing. brass, four- side sensing, stainless side sensing, brass,
terminal, 1/2" NPT steel, four-terminal, 1/ four-terminal, 1/2" NPT
conduit outlet opposite 2" NPT conduit outlet conduit outlet on
sensing side to right of sensing side. bottom of enclosure.
Group Number Description Group Group Group Group Group Group Group
1 2 3 4 5 6 7
1 Series/ 11 Series 10/Size 1-1/2" square x 4-9/16" long
Size XX X X X X X XX
1 Single Pole Double Throw (SPDT) Form C
2 Contact 3 Single Pole Double Throw (SPDT) Form C Latching (main- Series Termination
Arrange tained contact)(Group 4 must be a number 2,4 or 5) Size Options
- ment 5 Double Make Double Break, (DMDB), two-circuit, Form Z
6 Double Make Double Break, (DMDB), two-circuit, Form Z Contact Approval/
Arrangement Options
Latch-ing (maintained contact) (Group 4 must be a number
2,4 or 5) Sensing Outlet Enclosure
3 Sensing 1 Approx. 3/8" (9.53mm) side sensing Characteristics Position Material
2 Approx. 9/16" (14.3mm) side sensing, (Group 2 must be
Charac-
1 or 3) Termination A A1 18"
teristics
7 Approx. 1/4" side sensing 16 Gauge Potted-in PVC insulated TEW A2 36"
1 Behind sensing area
4 Outlet
2 Left of sensing area
stranded lead wires rated at 221oF 600V, UL/ A3 72"
Position CSA listed A4 144"
3 Right of sensisng area Termination B B1 18"
See
Illustrations 4 Same side as sensisng area 16 Gauge, 4 cond., potted-in SO rubber B2 36"
Below 5 Bottom of enclosure covered cable rated at 194oF, 600V, UL/CSA B3 72"
1 Brass-coated with flat black lacquer
5 Enclosure 2 Stainless steel (normally type 304)
listed B4 144"
Termination D DBA 3-pin Micro-change
Material 3 Epoxy coated brass Male Quick Disconnect only, 4-pin standard, DBD 4-pin Micro-change
4 Epoxy coated stainless steel potted-in connector. (Group 6 must be 7 or 8) DBG 5-pin Micro-change
1 Non-standard product - number only available if authorized by DCA 3-pin Mini-change
6 Approval/ factory. DCD 4-pin Mini-change
Options 2 High temperature to 445°F (229°C) factory-sealed with Teflon DCG 5-pin Mini-change
insulated leads. (Group 2 must be 1 or 3)(Group 5 must be 2) DD Certified for under-water
For lead length, refer to Group 7 "F" (Group 5 must be 2 or 4)
3 UL listed explosion proof for Class I, Groups A,B,C,D; Class II, Termination E EBB 3-pin Micro-change, 6ft. PVC
Groups E, F, G; Class III. (Group 5 must be 2 or 4) Male Quick Disconnect, 4-pin standard, EBE 4-pin Micro-change, 6ft. PVC
4 CSA/FM certified explosion proof for Class I, Div. 1, Groups potted-in with mating cable assembly. (Group EBT 5-pin Micro-change, 6ft. PVC
A,B,C,D; Class II, Groups E,F,G; Class III. (Group 5 must be 6 must be 7 or 8) ECB 3-pin Mini-change, 6ft. PVC
2 or 4) ECE 4-pin Mini-change, 6ft. PVC
5 Mine Safety Health Administration (MSHA) approved ECT 5-pin Mini-change, 6ft. PVC
“Explosion proof”, File # X/P 1504-1, Nov 20,1984 (Group 5 ED Impulse type, male and female
must be 2) (Group 7 must be B3) connmector with Delrin lock sleeve
6 CSA/FM Class 1, Div. 2, Groups A,B,C,D; Class II, Groups and 2ft, 16AWG SO cable for
E,F,G Class III underwater. (Group 5 must be 2 or
7 CSA certified General Purpose (Group 2 must be 1 or 3) Termination F 4)
8 UL listed General Purpose 18 gauge potted-in Teflon insulated leads F1 18"
0 CSA/FM Class 1, Div 2 Groups A,B,C,D; Class II, Groups rated at 482oF, 600V, UL/CSA listed F2 36"
E,F,G: Class III Terminal Block (Group 2 must be 1 or 3) F3 72"
(Group 7 must be 00) F4 144"
00 Terminal Block only. Other termination options such as lead length greater than
7 Termination 144", or customer specified connectors and/or cable are
Options See chart at right for more termination options. available as factory specials. Please call for more information.

OUTLET POSTIONS

SENSING AREA SENSING AREA SENSING AREA SENSING AREA SENSING AREA

1. On side of 2. To Left 3.To right of 4. On same 5. On


switch behind of sensing sensing area side as bottom of
sensing area area. sensing area enclosure