The document lists various standard abbreviations and their corresponding full forms used in construction. It includes standard codes from organizations like AASHTO, ASTM, ACI, API, ANSI, ISO and others. It also lists materials, departments, and miscellaneous terms relevant to construction standards and quality control.

Uploaded by

Taimoor Abbass
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
467 views12 pages

QC Notes Revised 12 Pages

The document lists various standard abbreviations and their corresponding full forms used in construction. It includes standard codes from organizations like AASHTO, ASTM, ACI, API, ANSI, ISO and others. It also lists materials, departments, and miscellaneous terms relevant to construction standards and quality control.

Uploaded by

Taimoor Abbass
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

STANDARD ABBRIVATIOS

TYPE CODE STANDARD FULL FORM TYPE CODE STANDARD FULL FORM
American Association of State Highway &
RFI Request for Inspection AASHTO
Transportation Official
ITP Inspection & Testing Plan ASTM American Society for Testing & Material

SATIP Saudi Aramco Typical Inspection Plan ACI American Concrete Institute

INTERNATIONAL STANDARDS
SAIC Saudi Aramco Inspection Checklist API American Petroleum Institute

IFC Issued for Construction ANSI American National Standard Institute


International Organization for
AFC Approved for Construction ISO
Standardization
MRI Material Receiving Inspection ICC International Code Council

PO Purchase Order IBC International Building Code


DOCUMENTATION

MTR Material Test Reports BS British Standards

INCR Internal Non Conformance Report PIP Process Industry Practice

LBE Log Book Entry PCI Pestered Concrete Institute

NCR Non Conformance Report SIS Swedish Standard Institution

CAR Corrective Action Report MOT Ministry of Transport

PAR Preventive Action Report CMU Concrete Masonry Unit

ACD Agreed Completion Date EPDM Ethylene Propylene Diene Monomer


MATERIALS

WR Work Sheet OPC Ordinary Portland Cement (Type-I)

MS Method Statement SRC Sulfate Resistance Cement (Type-V)

TQ Technical Query CLSM Controlled Low Strength Material

GI General Instructions GGBFS Ground Granulated Blast Furnas Slag

EPM Enterprise Project Management FBE Fusion Bonded Epoxy Coated Rebar's
Quality Management Information
QMIS CSD Consulting Service Department
System
DEPARTMENTS

SAES Saudi Aramco Engineering Standards BP&CTU Batch Plant & Civil Testing Unit
Saudi Aramco Material System
SAMSS APIU Area Project Inspection Unit
Specifications
SAUDI ARAMCO STANDARDS

SAEP Saudi Aramco Engineering Procedures PID Project Inspection Division

SAER Saudi Aramco Engineering Report SAPMT Saudi Aramco Project Management Team

SASDs Saudi Aramco Standard Drawings MC Moisture Content

SASC Saudi Aramco Sanitary Code OMC Optimum Moisture content


MISCELLANEOUS

SAGI Saudi Aramco General Instructions MDD Maximum Dry Density

SABP Saudi Aramco Best Practice FDT Field Density Test

SAPS Saudi Aramco Product Specifications CPT Cone Penetration Test

SASO Saudi Arabian Standard Organization NDG Nuclear density Gauge

Mandatory Saudi Aramco Engineering TDS Total Dissolved Solid


MSAER
Requirements
PPM Parts Per Million

(QA/QC CIVIL NOTES)BAG-09


SAES RELATED TO CIVIL
SAUDI ARAMCO ENGINEERING STANDARDS
Sr # SAES CODE DESCRIPTION

1 Q-001 Criteria for design & Construction of Structurel Concrete

2 Q-004 Installation of Piles & Conductors for Offshore Structures

3 Q-005 Concrete Foundations

4 Q-006 Asphalt & Sulpher Extended Asphalt Concrete Pavement

5 Q-007 Foundation & Supporting Structure for Heavy Machinary

6 AFC Approved for Construction

7 Q-010 Cement Base non shrink grout for Structural & Equipment Grouting

8 Q-011 Epoxy grouting for Machinary support

Criteria for design & construction for precast & prestressed concrete
9 Q-012
structures

10 A-113 Geotechnical Engineering Requirements

11 A-114 Earthwork & Backfill

12 M-100 Saudi Aramco Building Codes

13 L-450 Construction on land & near shore pipelines

14 L-460 Pipelines crosing under roads & railroads

15 M-001 Structural Design Criteria for non Building Structure

16 H-003 Protective coating for industrial concrete structure

17 M-006 Saudi Aramco Security & General Purpose Fencing

18 H-101 Approved Coating System for industrial Plants & Equipments

19 H-001 Selection Requirements For Industrial Coating

(QA/QC CIVIL NOTES)BAG-09


AMERICAN CONCRETE INSTITUTE (ACI)

Sr # ACI DESCRIPTION
Standard specifications for Tolerance for Concrete construction &
1 ACI-117
Materials
2 ACI-201.2R Guide to Durable Concrete

3 ACI-212.3R Chemical Admixture for Concrete

4 ACI 301-05 Specification for Structural Concrete

5 ACI-304R Guide for Measuring , Mixing, Transportation & Placing of concrete

6 AFC Approved for Construction

7 ACI-305 Hot weather Concrete

8 ACI-308 Guide to curing concrete

9 ACI-309 Guide for Consolidation of concrete

10 ACI-318 Building Code Required for Structural Concrete

11 ACI-347 Guide for Form Work Concrete

12 ACI-350 Code required for Environmental Engineering Concrete Structure

13 ACI-360R Design for slab on Grade

14 ACI-504R Guide to Sealing joints in concrete structure


Building Code Requirements and Specification for Masonry
15 ACI-530
Structures
16 ACI-207 Mass concrete

17 ACI-211 Ready mix concrete

18 ACI-224 Joint for concrete

19 ACI-237 Self consolidation concrete

20 ACI-229R Controlled Low Strenght Material (CLSM)

21 ACI-270 Controlled Low Strenght Material (CLSM)

(QA/QC CIVIL NOTES)BAG-09


ASTM Related to Civil
SR # DISCRIPTION ASTM REMARKS

1 Standard Specification for Epoxy-Coated Reinforcing Bars ASTM A775

Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Fabric for
2 ASTM A884
Reinforcement

REINFORCEMENT
3 Uncoated Deformed Steel G-420 & G-280 ASTM A615

4 Ductile Steel Elements to resist Earthquake effects G-420 ASTM A706

5 Galvanized Steel wire ASTM A1060

Approved for
6 AFC
Construction

7 Compressive Strength of Cylindrical Concrete Specimens ASTM C39

8 Cylinder Casting & Curing ASTM C31

9 Specification for Ready Mix Concrete ASTM C94

10 Slump Test ASTM C143

11 Slump Flow of SCC ASTM C1611

AGGREGATES & CONCRETE , Cementious Materials, GROUTS


12 Standard Specification for Portland Cement ASTM C150

13 Fresh Concrete Sampling ASTM C172

14 Standard Specification for Chemical Admixtures for Concrete ASTM C494

15 Standard Practices for Sampling Aggregates ASTM D75

16 Specification for Concrete Brick ASTM C55

17 Test Method for Flat and Flat and Elongated Particles in Coarse Aggregate ASTM D4791

18 Sieve Analysis of Fine and Coarse Aggregates ASTM C136

Test Method for Soundness of Aggregates by Use of Sodium Sulfate or Magnesium


19 ASTM C88
Sulfate

20 Ground granular Furnas slag ASTM-C989

21 Fly ash & Natural Pozzolans ASTM-C618

22 Standard Specification for Silica Fume Used in Cementitious Mixtures ASTM C1240

23 Coloring admixtures/Pigments used in Concrete ASTM C979

24 Cubical Compressive Strength of Epoxy Grout ASTM C579

25 Cubical Compressive Strength of Cement Base No shrink Grout ASTM C109

26 Specification for Load Bearing Concrete Masonry Units ASTM C90


CMU

27 Specification for Non-Load Bearing Concrete Masonry Units ASTM C129

28 Sampling & Testing CMU ASTM C140

(QA/QC CIVIL NOTES)BAG-09


ASTM Related to Civil
SR # DISCRIPTION ASTM REMARKS
Test Method for Materials Finer than 0.075 mm (No. 200) Sieve in Mineral Aggregates by
29 ASTM C117
Washing

30 Particle-Size Analysis of Soils ASTM D422

Standard Test Methods for Amount of Material in Soils Finer Than the No. 200 (75-um)
31 ASTM D1140
Sieve

32 Standard test method for density & unit weight of soil in place by sand-cone method ASTM D1556

Laboratory Compaction Characteristics of Soil Using Modified Effort 56,000 ft-lbf/ft³


33 ASTM D1557
(2700 KN- M/M³)

EARTH WORK (SOIL)


34 Test Method for CBR (California Bearing Ratio) of Laboratory- Compacted Soils ASTM D1883

Standard test method for density & unit weight of soil in place by Rubber Balloon
35 ASTM D2167
method

36 Classification of Soils for Engineering Purposes ASTM D2487

Standard Test Methods for Density of Soils and Soil- Aggregate in Place by Nuclear
37 ASTM D6938
Methods (Shallow Depth)

38 Maximum Index Density and Unit Weight of Soils Using a Vibratory Table ASTM D4253

Minimum Index Density and Unit Weight of Soils and


39 ASTM D4254
Calculation of Relative Density

40 Liquid Limit, Plastic Limit and Plasticity Index of Soils ASTM D4318

41 Cone Penetration Test ASTM D5778

42 Standard Test Method for Softening Point of Bitumen (Ring-and-Ball) ASTM D36

Test Method for Resistance to Plastic Flow of Bituminous Mixtures using Marshall
43 ASTM D1559
Apparatus

44 Thickness or Height of Core ASTM D3549

ASPHALT & BITUMENS


45 Preparation of bituminous specimen using Marshall Apparatus ASTM D6926

46 Flow & Marshall stability ASTM D6927

47 Job mix Formula for Asphalt ASTM D6307

48 Estimating Application Rate of Bituminous Distributors ASTM D2995

49 Bulk Density of asphalt ASTM D2726


EXPANSION
50 Preformed Expansion Joint Filler for Concrete Paving and Structural Construction ASTM D1751 JOINTS

Preformed Sponge Rubber and Cork Expansion Joint Fillers for Concrete Paving and
51 ASTM D1752
Structural Construction

52 Anchor Bolt Type-1/1S (Grade-A) Simple Head ASTM-A307


ANCHOR BOLTS

53 Anchor Bolt Type-2/2S (Grade-36) Single Nut & Tack weld ASTM-A36

54 Anchor Bolt Type-3/3S (Grade-105) Double Nut & Lock by Counter punching. ASTM-A193

55 Liquid Membrane- Forming Compounds for Curing Concrete ASTM C309


MISC

56 Vapor Barrier Sheet ASTM E1745

(QA/QC CIVIL NOTES)BAG-09


SAMSS RELATED TO CIVIL
SAUDI ARAMCO MATERIAL SYSTEM SPECEFICATIONS
SR # DESCRIPTION SAMSS CODE

1 Caulking Compound (Joint Sealant) 09-SAMSS-075

2 Ready-Mixed Portland Cement Concrete 09-SAMSS-097

3 Epoxy Coating of Steel Reinforcing Bars 09-SAMSS-106

4 Fabrication of Structural and Miscellanies Steel 12-SAMSS-007

5 Aggregates for Concrete 09-SAMSS-088

6 AFC Approved for Construction

7 Concrete Masonry Units and Concrete Building Bricks 09-SAMSS-016

ANCHOR BOLT
1 ACI for Anachor Bolt ACI-318-08

2 Standard Drawing AA-036322 Sht. 001

3 Minimum clear distance from anchor bolts or sleeves to edge of concrete 100 mm

4 The minimum anchor bolt diameter 20 mm


Variation in c/c dimension between the adjacent anchor bolt within anchor
5 3mm or less
bolt group
6 Variation in c/c dimension between adjacent Bolt Group to Another Group 6mm or less

7 Anchor Bolt Design and Installation SABP-Q001

3 Types

Type 1 & 1S
8 Types of Anchor Bolt ("S" Used for Sleeve)
Type 2 & 2S

Type 3 & 3S

9 Thickness of Grout+Thickness of Base Plate +2d Projection for Single nut

10 Thickness of Grout+Thickness of Base Plate +3d Projection for Doubble nut

(QA/QC CIVIL NOTES)BAG-09


SAES -A114 EXCAVATION & BACKFILL

Sr # DESCRIPTION Standard Requirements

1 SATIP Used for SAES-A114 SATIP-A-114-01

50 mm & 0-20% Passing Sieve #200


2 Size of Select Fill
(0.075mm)

3 Max Size of General Fill 75mm

4 Max Size of Marl Fill 75mm

5 Max Size of Clean Sand 1/4" (6.25mm)

6 AFC Approved for Construction

2
7 One Test Under Pavements/Subgrades 1 Test/200m

2
8 One Test General Fill 1 Test/500m

2
9 One Test Under Foundations 1 Test/100m

10 Liquid Limit 0-35

11 Plastic Limit 0-12%

Select Fill material shall be placed in lifts not exceeding in loose


12 200 mm
depth
General Fill material shall be placed in lifts not exceeding in loose
13 300 mm
depth
All Fill material shall be placed in lifts not exceeding in loose
14 100 mm
depth for hand-operated compaction

15 Moisture Content for building/Foundations ± 3% of the Optimum Content

90 % for Cohesive Soil


16 Static Load Below 320 Kpa When Compaction Required
70 % for Cohsionless Soil
95 % for Cohesive Soil
17 Static Load Over 320 Kpa When Compaction Required
85 % for Cohsionless Soil
95 % for Cohesive Soil
18 Under Concrete or Asphalt Pavements Compaction Required
85 % for Cohsionless Soil
90 % for Cohesive Soil
19 General Fill for Area Not Designated As open or landscape
70 % for Cohsionless Soil
85 % for Cohesive Soil
20 General Fill for Area Designated As open or landscape
65 % for Cohsionless Soil

2
21 Cone Penetration Test 1 Test/1000m

(QA/QC CIVIL NOTES)BAG-09


SAES -Q001 , SAES-Q010 , SAES-Q011 , 09-09SAMSS-097
Sr # DESCRIPTION Standard Requirements
1 SATIP Used at Batch Plant SATIP-Q-001-01

2 SATIP Used at site For Cast in Place Concrete SATIP-Q-001-02

3 SATIP Used at Structural Precast/Prestressed Concrete at Fabrication Yards SATIP-Q-001-04

4 SATIP Used For Cement Based Non Shrink Grout SATIP-Q-010-01

5 SATIP Used For Epoxy Grout SATIP-Q-011-01

6 AFC Approved for Construction


Height =30 cm
7 Slump Cone Size
Base Dia=20 cm Top Dia= 10 cm
8 Grout Cubes Size 50x50x50 mm
Height=30 cm
9 Concrete Cylinder Size
Dia=Ø15 cm
10 Structural Concrete Strength 4000 Psi (28 Mpa) Minimum

11 Precast Concrete Strength 5000 Psi (35 Mpa) Minimum

12 Envoirmental Engineering Concrete Structure Compressive Strength 5000 Psi (35 Mpa) Minimum

13 Non Structural Compressive Concrete 2000 Psi (14 Mpa) Minimum

14 Epoxy Grout Compressive Strength 12000 Psi (80 Mpa) Minimum

15 Epoxy Grout Compressive Strength 5000 Psi (35 Mpa) Minimum

16 Water Cement Ratio for Structural Concrete 0.4

17 Water Cement Ratio for Non Structural Concrete 0.4

18 Water Cement Ratio for Non Structural Concrete 0.6

19 Water Cement Ratio for Mortar 0.8

20 Cement Content in Structural Concrete 350-370 Kg/Cm3

21 Cement Content in Non Structural Concrete 270 Kg/Cm3

22 Cement Content in Precast Concrete 370 Kg/Cm3

23 Density of Concrete 2400 Kg/Cm3


G-60 or 420 Mpa
24 Steel Grade
G-40 or 280 Mpa
25 Vapor Barriers Sheet Thickness for Curing Purpose 0.15mm

26 Vapor Barriers Sheet Thickness for Below foundations 0.25mm

27 Concrete Slump 150±40 mm (110-190mm)


Max 35°C as per Aramco Standard
28 Concrete Temperature
Max 32°C as per ACI
29 Concrete Max Layer 450 mm
Max=20 mm
30 Aggregate Size for Concrete
Min=10 mm
31 TDS Allow for Mixing Water 500 PPM Max

32 TDS Allow for Curing Water 1000 PPM Max

33 TDS Allow for Mixing & Curing of Non Shrink Grout 500 PPM Max

34 TDS Allow for Washing Aggregates as per 09-SAMSS-088 3500 PPM Max

35 PH Value of Mixing Water (Potential of Hydrogen) 6-8

(QA/QC CIVIL NOTES)BAG-09


SAES -Q001 , SAES-Q010 , SAES-Q011 , 09-09SAMSS-097
Sr # DESCRIPTION Standard Requirements
36 Cement Based Non Shrink Grout Temperature 23°C ±3

37 Surrounding Temperature for Epoxy Grout 15°C to 32°C


8 Cylinders for Normal Concrete.
38 Cylinder obtained from every 115m3 or less Concrete
12 Cylinder in case of use cementious
39 Concrete Drop Height Max 1 M

40 Concrete cast against or permanently exposed to earth 75 mm

41 Formed concrete exposed to earth or weather Supporting Process Equipment 75 mm

42 Concrete exposed to sea water, raw water or sewage 75 mm

43 Buildings, walkway platforms, stairs, AC pads 50 mm

44 Beams, columns 50 mm

45 Slabs, walls, joists 25 mm

46 Where foundations blockout, shall be placed diagonal reinforcing bars. 800 mm Length & Ø12 mm

47 Tie Wire For Reinforcement 1.29 mm 16 Gauge

48 Concrete Delivery Time After adding Water 90 Minutes Max

49 Concrete shall be discharged before the drum has revolved 300 RC Max

50 When Cold join is occurred delay in concrete delivery 20 Minutes

51 Sulfur Pit Concrete Strength 50 Mpa

52 Sulfur Pit Concrete Cement Content 65% GGBFS & 35% Type-I Cement (50 MPA)

53 Sulfur Pit Slump Flow 650 ±80 mm

54 Slump Flow for Self Consolidation Concrete 600 ±65 mm

1st Layer= 140 mm (25 time Rodding)


55 Slump Cone Fill 2nd Layer= 90 mm (25 time Rodding)
3rd Layer= 70 mm (25 time Rodding)

56 Silica Fume Used in Concrete 7-10% By Weight of Cement

57 Natural Pozolans Upto 50% Maximum

58 Fly Ash 25% minimum

59 Ground Granulated Blast Furnace Slag (GGBFS) 50-70 %

60 Plant scales shall be calibrated in 1 Year 3 Time Minimum

61 Lab Equipment's shall be calibrated in 1 Year 2 Time Minimum

62 Compressive strength is required at 28 days


If concrete containing natural Pozzolan, fly ash, GGBFS, or mix of any
63 56 days
cementitious material

(QA/QC CIVIL NOTES)BAG-09


SAES-Q006 Asphalt Concrete Pavement including Sulfur Extended Asphalt

Sr # DESCRIPTION Standard Requirements


SATIP Used For Conventional Asphalt & Sulfur Extended Asphalt Paving
1 SATIP-Q006-01
- Batch Plants Management & Third Party Laboratory

2 SATIP Used For Conventional & Sulfur Extended Asphalt Paving SATIP-Q006-02

3 Compaction of Subgrade 95% Min

4 Compaction of Sub Base 95% Min

5 Compaction of Aggregate Base Cource 98% Min

6 AFC Approved for Construction

7 Sub Base Material Class-A CBR Value at 95% Compaction 25. Min

8 Sub Base Material Class-B CBR Value at 95% Compaction 25. Min

9 Compaction of Asphalt 95% Min

10 Base Material Class-B CBR Value at 98% Compaction 50. Min

11 Sub Base Material Class-A Size 2-½"

12 Sub Base Material Class-B Size 2"

13 Base Material Class-A Size 2-½"

14 Base Material Class-B Size 1-½"


2
15 Core Test Criteria 5 Core/1000m Lot

16 Core Thickness Tolerance 1 Cm or 15% of the design thickness

17 Hot Mix or Conventional Asphalt Temperature 139°C-163°C Spreading Time 139°C

18 Sulfur Extended Asphalt Temperature 130°C-140°C Spreading Time 115°C

19 Polymer Modified Asphalt Temperature 170°C+5°C Spreading Time 155°C-165°C

20 Compacting Shall be Continue until temperature fall below 90°C

Aggregates= 93% To 96%


21 Asphalt Job Mix Formula
Bitumen=4% To 7%
30% By Weight of bitumen & replaced with
22 Sulfur used in asphalt
bitumen

23 Temperature for MC-70 or RC-70 50°C to 80°C

24 Temperature for MC-250 or RC-250 65°C to 105°C

25 Prime Coat application Rate 0.65-1.75 Liter/m2

26 Tack Coat application Rate 0.25 Liter/m2

27 Sub Base & Base Test Perform 1 Test/500m2

(QA/QC CIVIL NOTES)BAG-09


SAES-Q006 Asphalt Concrete Pavement including Sulfur Extended Asphalt

Sr # DESCRIPTION Standard Requirements


Asphalt sample for
28 1 Sample/200 Ton_____ 1 Sample/250 Ton
Extraction/Grading_______Marshal Properties
Asphalt sample for
29 1 Sample/250 Ton_____ 1 Sample/300 Ton
Extraction/Grading_______Marshal Properties
Asphalt sample for
30 1 Sample/300 Ton_____ 1 Sample/400 Ton
Extraction/Grading_______Marshal Properties

31 Moisture Content ±1.5% of the OMC

32 Surface Deviation for Sub Grade & Sub Base Testing with 3M Straight Edge ±20 mm

33 Surface Deviation for Base Testing with 3M Straight Edge ±10 mm

34 Surface Deviation for Asphalt Tested with 4M Straight edge

35 When Placed Parallel to the Centerline not exceed 3mm

36 When Placed Perpendicular to the Centerline not exceed 6mm

37 Aggregate size for Asphalt Binder Cource 1-½ inch

38 Aggregate size for Asphalt Wearing Cource ¾ inch

39 Ambient Temperature at the time of asphalt paving Min 4°C

40 Ambient Temperature at the time of Prime Coat Min 16°C

41 Prime coat & Asphalt coat Tested 37,800 liters usage or 31,500 m² coverage

42 MC material shall be maintained at least 10°C below the flash point of the material

43 Prime Coat Applied 300 mm greater on each side of the road

44 Each test is made by the average of 3 readings within the radius of 2 m. Sub Base & Base Material

45 Sub Base & Base Material Layer Thickness Shall not Exceed from 150 mm after Compaction

46 Standard Drawings AA-036246

(QA/QC CIVIL NOTES)BAG-09


SAES -M100
Sr # DESCRIPTION Standard Requirements
A Concrete Masonry Unit (CMU)
1 Standard Drawing AA-036602

2 SATIP Used for CMU & Plaster SATIP-M100-01

3 Concrete Masonry Unite Types (Hollow & Solid) Load Bearing & Non Load Bearing

4 Compressive Strength for Load Bearing CMU Min 1900 Psi of Average 3 Units

5 AFC Approved for Construction

6 Reinforcing/Dowel Bar Minimum Ø12 mm & C/C Spacing 1.2 M Max

7 1 Day Work Progress Height 1.2 M Maximum

8 Mortar Strength 1800 Psi

9 1st Layer Mortar Thickness 6.4 to 19.1 mm

10 Head & Bed Joints Thickness 9.5mm

11 Ladder mesh Provide as per IFC Drawings or every 40 cm

B Roof Water Proofing


1 SATIP Used for Roof Water Proofing SATIP-M100-02

2 Light weight Foam Concrete Thickness 50mm Min.


3 EPDM Thickness 1.52 mm Min.
4 Water Ponding for roof Leakage test 25 mm Min. (at highest point)
5 Bituminous Membrane Thickness 5mm
6 Min Time for Water Leakage Test 24 Hrs.
7 Washed Gravel Thickness 50mm Min.
8 Washed Gravel Size 19mm
9 Drainage Systems Primary & Secondary Drainage Systems
10 SATR Used For Roof Leakage Test SATR-M-1014
11 Scoopers Opening For Secondary Drainage System Not less than 4 Inches
B Gypsum Board
1 SATIP Used for Gypsum Board SATIP-M100-05

2 Gypsum Board thickness 12.7-15.9 mm

3 Gypsum Board Width 1220-1370 mm

4 Gypsum Board Types 3 Types

5 Type - Normal/Standard gypsum Board White Color

6 Type -Fire Resistance gypsum Board Pink Color

7 Type -Moisture Resistance gypsum Board Green Color

8 Studs & Runners Spacing 400-600 mm C/C

9 Screws Spacing 300 mm