CW-100G Pro Checkweigher User Manual
CW-100G Pro Checkweigher User Manual
CW-100G
User’s manual
(Applicable for MCGS+C01 version)
531701010023Ver A2
Contents
1. Summary ............................................................................................. 1
3. Operation .................................................................................... 12
7. Communication .............................................................................. 38
9. Size .................................................................................................. 52
10.2 Check the failure cause and treatment method of weight scale . 54
1. Summary
CW-100G checkweigher is an industrial automatic checkweigher with high speed, high
precision developed by our company to meet the changing technological update.
Full touch screen (15 inch super large screen) makes CW-100G checkweigher easy to
operate, external expansion of IO input and output and external serial port communication
to achieve multi-point control, monitoring and remote control of the product.
Note; Scale stands are strictly prohibited from being used over the range.
1
CW-100G (C01+MCGS)
2
CW-100G (C01+MCGS)
2. Product installation
2.1 Overall appearance
The product appearance is shown in Figure 2 -1 below.
3
CW-100G (C01+MCGS)
9 Conveyor belt The delivery end of the scale table on the object
Adjust the distance between the check weighing platform and the front and rear end
conveying mechanism is 9 ~ 11mm, and the check weighing platform shall not be in
contact with other equipment. If the front and back end conveying mechanism is not equal
to the height, it is necessary to add the oblique conveying mechanism on one side, and add
the horizontal conveying mechanism connection on the side of the oblique mechanism (to
leave a gap) to check the weight scale platform, to ensure that the check weight scale
platform level and the height of the front and back end conveying mechanism.
4
CW-100G (C01+MCGS)
The electric control box can be arbitrarily installed on the left and right sides of the
checkweigher to facilitate the operation of the production process.
Any wiring and disconnecting operation can only be carried out after power off. After
the operation is completed, check before power on.
2. The serial port is fixed to RS485 communication, where the 485(A) pair should be
connected to 485(A) or 485(+), and the 485(B) pair should be connected to 485(B) or
485(-).
3. The switching quantity input point is valid at low level (DC0V) and does not allow
access to high voltage or alternating current.
4. Switching quantity output point access relay coil for intermediate control, so the
other end of the relay can access DC or AC power supply switching quantity.
5
CW-100G (C01+MCGS)
Serial Function
number
6
CW-100G (C01+MCGS)
7 Sensor terminal
13 Reset key
DI1: running input. In the stopped state, the input is valid and the system enters the
running state.
DI2: Stop input. In the running state, the input is valid and the system enters the stop
state.
7
CW-100G (C01+MCGS)
DI3: clear the alarm. When the system generates an alarm, change the input to be
effective and the alarm will be cleared.
DI4: out-of-tolerance elimination is completed. When the input is valid, the output of
out-of-tolerance elimination is invalid.
DI5: Under error culling is complete, under error culling output is invalid when this input
is valid.
DI6: continuous packet detection. This input signal is given by the photoelectric sensor
installed on the front conveyor line of the checkweigher and used in conjunction with the
busy stop output to control the start and stop of the front conveyor line of the checkweigher.
When there is an object being detected on the weighing platform and the signal is effective,
the busy stop output is effective.
DI0V: switching quantity power supply DC24V-.
DI24V: Switching quantity power supply DC24V+.
DO1: No definition.
DO2: undefined.
DO3: undefined.
DO4: undefined.
DO0V: switching quantity supply power DC24V-.
DO24V: switch quantity power supply DC24V+.
DOCOM: switch quantity common end.
EX+: Power positive, SN+: induction positive, EX- : power negative, SN- : induction
negative, SG+: signal positive, SG- : signal negative.
MT A: RS485 communication A.
MT B: RS485 Communications B.
MT G: RS485 Communication (GND).
8
CW-100G (C01+MCGS)
K1: defined as operation. When the system is in operation state, the relay output is
closed, and K1A and K1B are switched on. Used to control the start and stop of frequency
converter.
K2: defined as stop. When the system is in the stopped state, the relay output closes
and K2A and K2B are switched on. This definition is the factory default setting and can be
modified according to the actual needs.
K3: defined as out of tolerance elimination, the product test result is out of tolerance,
and within the range of out of tolerance elimination duration, the relay output is closed, K3A,
K3B switched on. This definition is the factory default setting, and can be modified
according to the actual demand.
K4: defined as under error elimination, product detection result is under error, and
within the range of under error elimination duration, the relay output is closed, K4A, K4B on.
This definition is the default setting of the factory, and can be modified according to the
actual demand.
K5: defined as alarm. When alarm occurs in the system, the output of the relay is
closed and K5A and K5B are switched on. This definition is the factory default setting, and
can be modified according to the actual demand.
K6: defined as batch completion, after the completion of the product test batch, the
relay output is closed, K6A, K6B on. This definition is the factory default setting, and can be
modified according to the actual demand.
K7: defined as qualified indication, after the product test is qualified, the relay output is
closed, K7A, K7B on. This definition is the factory default setting, and can be modified
according to the actual demand.
K8: defined as rejection of unqualified. When unqualified is detected, the output of the
relay is closed, and K8A and K8B are switched on. This definition is the factory default
setting, and can be modified according to the actual demand.
9
CW-100G (C01+MCGS)
User provide
OUT1~4 can
self-defined
User provide
Rejector mechanism
solenoid valve
Figure 2-4 shows the power supply and motor interface diagram, defined as follows:
11
CW-100G (C01+MCGS)
3. Operation
3.1 Operation summary
Boot
Technician
w
login
New product h
c
e
h
n
Set
o
parameters b
o
s e
Starting Data Power
e f
weight query off
o
C check Figure 3-1 Procedure
r
h
3.2 Limit removal e
o
Before use, the two limit bushings need to be installed from the transport position to
the working
o P by the arrow in Figure 3-2 is the installation
position. The position indicated
position of the limit bushings. r
s
e o
t d
h u
e ct
Limit bushing install at here when
p working
r
o
d
u Limit bushing install at here during
c transportation
o 12
n
p
CW-100G (C01+MCGS)
Correct time parameters can effectively help users check the production inspection results,
relevant production parameter changes and alarm information, help to improve the
production pass rate and production speed and reduce production consumption.
The weight display area of the checkweigher displays the real-time weight value in the
stopped state, and displays the weight test result in the running state until the next
object is effective.
Button and operation frame operation instructions (applicable to all operation interfaces of
the device) :
13
CW-100G (C01+MCGS)
1. Click this button to enter the interface of creating products and setting product
parameters.
3. Click this button to enter the data interface to view the relevant check data.
7. Click this type of action box to modify the value of this item.
9. Click this type of action box to select Settings for this definition.
10. Click this type of action box to perform the corresponding operation.
11. Click this type of action box to open and close the corresponding function Settings.
If the weight check scale shows that the weight is unchanged, the stable identifier bit
is on; otherwise, the stable identifier bit is off (the stable identifier bit is only related to the
weight state, and has nothing to do with the operation of the checkweigher and the size of
the weight value).
14
CW-100G (C01+MCGS)
15
CW-100G (C01+MCGS)
After the product is successfully selected, the current number will be displayed as the
number of the selected product in the upper right corner of the product list page.
The new product number cannot be selected during the operation of the weight check
scale;By default, the product number selected by the checkweigher before exit (stop
operation or the checkweigher power off).
3.5.2 New product parameters
On the product list page, click "Add Product" to jump to the "Product Parameters"
interface to add a new product parameter. The new product number will be added to the
existing product in sequence. You do not need to select the product number.For details,
refer to "Operation Instructions on Buttons and Operation Frames" in Section 3.3.2.
★ The new product number cannot be added during the operation of the weight check
scale;The newly added product parameter values are the default initial values of the
system, which need to be set according to the actual product parameters and production
requirements.
16
CW-100G (C01+MCGS)
Name Instructions
Passing Speed The speed at which the current weight checking device detects
the product
Lower limit value In the process of weight inspection, if the weighing value is
less than the target value-lower limit value, it will be judged as
undererror
17
CW-100G (C01+MCGS)
Qualified culling The distance traveled by the product from the end of the scale
distance to the start of the qualified culling mechanism
Out-of-tolerance The distance traveled by the product from the end of the scale
culling distance to the start of the offset removal mechanism
Underweight culling The distance traveled by the product from the end of the scale
distance to the start of the underbalance removal mechanism
Unqualified culling The distance traveled from the end of the scale to the
distance nonconforming product after the start of the removal
mechanism
The time of the The continuous action time of the rejection mechanism for
unqualified culling nonconforming products (including out-of-error + undererror)
action
Sampling starting The sampling data to this percentage is discarded after the
percentage object is placed on the scale
Percentage used for Data that is consistently used as a percentage from the start of
sampling sampling is used to calculate the weight check result
Dynamic clearing When the belt is running, within the stability determination
stability range time, the weight variation range is judged to be stable within
18
CW-100G (C01+MCGS)
Dynamic zeroing and When the belt is running, within this setting value, the range of
stabilizing time weight variation is judged as the stability of the scale platform
within the range of dynamic zero clearance stability. Only when
the stability allows the dynamic zero clearance
Cont.ZERO Failure How many times did the weighing platform fail to reset
Alarm Threshold dynamically during the weighing process
Number of Averaging During servo control, the average value of the set number of
Samples products is compared with the user set value, and the
difference between them is used as the basis of control. When
it is 0, the filling servo function is not used
Tendency Max.Limit When the weight is higher than this value, it will not participate
in the average value calculation and will generate an alarm
Tendency Min.Limit When the weight is lower than this value, it will not participate
in the average value calculation and will generate an alarm
Servo motor dead zone If the absolute value of weight error is lower than this value, it
will not be corrected
19
CW-100G (C01+MCGS)
The standard weight refers to the weight of the product to be checked, and the upper
and lower limit is the allowable deviation value of qualified product;If it is not necessary
to calculate the packaging weight of the product, the outer packaging weight of the
product can be written into the tare weight column, and the net weight should be filled
in the standard weight column.
The product number is automatically generated by the system;The linear speed of the
belt is calculated from the detection speed, and changes with the change of the
detection speed. It cannot be filled in (the linear speed of the belt should be consistent
with the linear speed of the front and rear end conveying mechanism).
The compensation weight difference value is calculated by dynamic calibration. Under
normal circumstances, manual change is prohibited to prevent deviation between the
product weight and the actual weight.
When filling in the product parameters, attention should be paid to its value range.
Generally, if it is lower than the lower limit of the parameter range, the parameter
value will remain unchanged; if it is higher than the upper limit of the parameter range,
the upper limit of the parameter range will be written by default.
The definition of weight checking speed, belt speed and correction coefficient is
described in detail on the help interface of product parameters. If necessary, you can
click "Help" to view.
3.5.4 Delete product parameters
On the product list page, select the product to be deleted and click "Delete Product"
to delete the product. After deleting the product, the following product parameters will
move forward in order, and the product number will move forward. The product cannot be
deleted during the operation of the weight check scale; In order to prevent product
parameters from being incorrectly deleted, the product name should be set reasonably
when setting product parameters.
20
CW-100G (C01+MCGS)
Name Instructions
Calibrate the empty Eliminate external interference, the scale table at zero and
scale table stable, can be clicked
The weight calibration Put the weight on and after entering the weight of the weight,
scale click
Empty scale voltage The voltage value of the sensor when the top of the scale is
value emptied
Weight voltage value The voltage value of the sensor after placing the weight
During calibration, ensure that the checkweigher is in the stopped state; otherwise, the
interface of the checkweigher cannot be entered;Calibration should ensure that there is
no item on the weighing platform, no vibration on the weighing platform, and no
relatively strong air flow around the checkweigher.
When the weighing platform is empty, ensure that the weighing platform is at zero
position and stable. Otherwise, please eliminate interference and click "Calibrate the
weighing platform". The second step can only be carried out when the touch screen
indicator is 0 and the stability sign is lit.
When placing the weight, try to avoid the weight hitting the surface of the weighing
platform. Enter the correct weight into the weight box of the weighing platform,
otherwise it will lead to inaccurate calibration scale or calibration failure (the weight of
the weighing platform should be greater than the product weight and not exceed the
maximum range of the checkweigher).
If the calibration fails, please check whether the scale is stable and whether the sensor
is interfered by the outside world or whether the scale is in contact with other
equipment, and re-calibrate after troubleshooting.
3.6.2 Dynamic calibration of scale
On the product page, click "Dynamic calibration" to enter the dynamic calibration
interface, and perform dynamic calibration according to the text prompts. When completed,
relevant parameters will be automatically calculated and generated and product parameters
will be written.Click "Exit" to return to the main interface after completion of calibration.For
details, please refer to Section 3.3.2 "Operation Instructions for Buttons and Operation
Frames".
Name Instructions
Get the weight Stop the belt running and put the test material on after the
static weight value shown
The belt will run, and after the statically weighed object has
passed, it should be moved back to the front stage, repeatedly
running dynamically, and the controller will automatically
Start up
record the dynamic weight. General dynamic calibration ten
times, the number of dynamic calibration to check the weight
scale will automatically stop
Maximum weight The maximum value of the weight check result during dynamic
calibration
Average weight During dynamic calibration, the average weight of each check
will be updated after the number of dynamic calibration is
completed
Correction factor The standard value is 1000. After the number of dynamic
calibration is completed, the controller will automatically
calculate this value according to the dynamic result and static
weight.
Calibration must ensure that the check scale in the stopped state, otherwise can not
enter the dynamic calibration interface;When calibrating, ensure that there is no item
on the scale, no vibration on the scale, and no relatively strong air flow around the
scale.
When the weighing platform is empty, it should be ensured that the weighing platform
is at zero position and stable, otherwise, please eliminate external interference and
carry out "zero clearing" operation.
When placing the product, the product should avoid hitting the surface of the weighing
platform. Only after the weight is stable can you click "Obtain static weight";If the
product has a gross weight value, please set the gross weight value first before
23
CW-100G (C01+MCGS)
dynamic calibration.
The initial value of learning times defaults to 10. If the learning results are poor in
accuracy, you can appropriately increase the number of learning times;If the
production requirement is not high, the learning times can be appropriately reduced to
improve the learning speed;External interference should be avoided in the learning
process, and the system will automatically save the learning results and display them
after the completion of learning.
The change of product detection speed requires dynamic calibration again.
The principle of dynamic calibration, attention to implementation and alternative
methods are introduced in detail in the interface of dynamic calibration parameter help.
If necessary, you can click Help to view.
24
CW-100G (C01+MCGS)
4. Data viewing
The check weight scale has the function of data storage and query, which is
convenient for users to check the historical check weight data and event information.Under
the main interface, click "Data" to enter the interface for viewing data (no permission is
required for data interface).
After testing a certain number of products, you can insert the USB flash drive to the
touch screen to export the existing weight data, otherwise too much weight data will
cause inconvenience to data query.
Changing the production of the product and adding new products will not affect the
query of the test result, delete the product, please first check out the test result and
clear.
25
CW-100G (C01+MCGS)
4.2 Statistics
Click "Statistics Data" to enter the check weight data statistics interface, which displays
product distribution intuitively. Click "Print data" to print statistics information, click "Export
data" to export statistics information to the USB disk inserted into the touch screen, click
"Delete data" to clear statistics information.For specific operation methods, refer to
"Operation Instructions on Buttons and Operation Frames" in Section 3.3.2.
26
CW-100G (C01+MCGS)
27
CW-100G (C01+MCGS)
5. Quantity of switches
5.1 I/O I/O testing
Click "Switch quantity" on the setting page to enter the IO test interface. The system
provides 6 input terminals and 12 output terminals, which users can decide whether to use
according to production requirements.For specific operation methods, please refer to
"Operation Instructions on Buttons and Operation Frames" in Section 3.3.2.
IO test is to test whether the IO port is properly connected to the external device.
During the test, click "Switch" after the output to output 1-8. If the corresponding relay coil
is closed (red indicator light on the relay base) and the corresponding device is in action,
the connection is normal and the output point of the checkweigher is valid; otherwise,
please check whether the connection between the output point and the device is
correct;Click the "switch" behind the three-color light, if the three-color indicator light is on,
the connection is correct.
The input test can be carried out by setting the low level signal (DC0V) at the input
end. If the low level signal is effective at the corresponding input port, the test indicator
box behind the corresponding input point ON the touch screen will light up and display
"ON" (The photoelectric input can be blocked on the main interface when testing the
photoelectric input, if the corresponding input and discharge marks are lit up, the
photoelectric input is effective).The input and output signals can be defined by themselves.
The default switching quantity is defined as follows:
DO 1 Undefined
DO 2 Undefined
29
CW-100G (C01+MCGS)
DO 3 Undefined
DO 4 Undefined
I01 Input When the input is valid, it means that the input
photoelectric photoelectric sensor has sensed the measured object
I02 Output When the input is valid, it means that the output
photoelectric photoelectric sensor has sensed the object under test
I03 Run When the input is valid, the device will boot into the
running state
I04 Stop The device will stop running when the input is valid
I05 Clear alarm When the input is valid, the device will clear the current
alarm
I06 Aberration cull When the input is valid, the offset cull is complete
complete
I07 Owe culling When the input is valid, the underbalance culling has been
complete completed
I08 Packet detection When the input is valid, the device performs packet
connection detection
30
CW-100G (C01+MCGS)
I11 Run/stop [edge] When the device is in the stopped state, the signal input is
effective, the device starts to enter the running state;
I12 Stop (level) The signal is valid and the touch screen cannot start the
device
O01 Out-of-tolerance If the weight check result is out of tolerance, the output is
indication valid and continues until the next weight check is completed.
O02 Owe indication If the weight check result is underweight, the output is valid
and lasts until the next weight check is completed.
O06 Out-of-order The weight check result is out of tolerance, according to the
culling set out of tolerance eliminator distance delay, and then
according to the set duration output valid.
O07 Owe culling The weight check result is the undererror, according to the
set offset culler distance delay, and then according to the
set duration output valid.
O09 Number of This output is valid when the set number of batches is
batches reached.
completed
O10 Qualifying If the weight check result is underweight, the output is valid
instructions and continues until the next weight check is completed.
31
CW-100G (C01+MCGS)
O11 Busy Stop + When the system is in busy state, busy detection is valid,
communication this output is invalid, busy state is invalid and
communication command is received, this output is valid,
busy detection is invalid, this output is valid
O12 Busy stop When the system is in busy state, busy detection is valid and
this output is invalid, busy state is invalid, this output is
valid, busy detection is invalid, this output is valid
O13 Feed According to the state of the input photoelectric output, the
photoelectric input photoelectric effective, then the output effective.
output
32
CW-100G (C01+MCGS)
6. Working parameters
6.1 Working parameter Settings
Click "Set" to enter the interface of working parameters, and the user can decide
whether to open according to the production needs. If the corresponding alarm is generated
after opening, the weight checking scale will automatically alarm or alarm stop. It needs to
manually click "clear alarm" or input the signal of "clear alarm" to start the weight checking
again (after the alarm is generated and until the clear alarm is completed, The motor of the
check checkweigher runs but does not determine whether the object is on or off the
weighing platform, nor does it carry out weighing operation), and the alarm information is
stored in "Data" - "Alarm information".For specific operation methods, please refer to
"Operation Instructions of Button and Operation Frame" in section 3.3.2.
Name Instructions
The alarm stops when The default number of over/under error queue is 20, which
means that if the removal distance is long enough, that is, it
the queue is full
takes a long time for the products to be removed to arrive at
the removal institution, there can be more than 20 products in
the middle. If there are more than or equal to 20 over/under
33
CW-100G (C01+MCGS)
If not eliminated in After the next unqualified product has gone through the
reinspection process, the last product has not been removed,
time, the alarm will be
the alarm will be stopped
stopped
Busy alarm stop In the last product has not been out of the inspection belt, the
next product into the inspection belt, it will show busy alarm
and stop.If the back end is connected with an over and under
error elimination mechanism, the default is over error
elimination
If the maximum time There are two kinds of action;1. If the maximum time on the
scale set on the touch screen is more than 2 times of the time
on the scale is
required for the object to pass the scale, the maximum alarm
exceeded, it will alarm time on the scale is twice of the time required for the object to
pass the scale. 2. If the maximum time on the weighing
and stop
platform set on the touch screen is less than or equal to twice
the time required for the object to pass the weighing platform,
the maximum alarm time on the weighing platform is the
maximum time on the weighing platform set on the touch
screen
The number of super In the product parameter setting interface, you can set the
alarm number of continuous nonconformance. If the set value
continuous
is not zero and the switch is on, the number of continuous
disconformance alarm nonconformance will alarm and stop when it reaches this value
stops
34
CW-100G (C01+MCGS)
Upper limit of motor The maximum load the motor can withstand
load
Stop above the motor The upper limit of motor load can be set in the system
parameter interface of the product. When the weight of the
load limit
product or the object to be weighed exceeds the set upper
limit, it will alarm and stop
Overweight or Display on the main page that the result of this test product is
out of tolerance or under tolerance and the device will stop.If
underweight alarm and
you need to use this function, you need to move forward the
stop discharge photoelectric position, please contact our technical
department for details
The main page On the main page, it shows that the result of this test is out of
tolerance, under tolerance, or qualified
displays the
information of
overshoot and
undershoot
The main page will Only the product weight test result of this test is displayed on
the main page
display only the weight
test result
Auxiliary display of Display the detected real-time product weight on the main
page
real-time weight
Check scale for When calibrating the scale, the weight variation range is
judged to be stable within this setting value
stability range
Judge the range of During the stabilization time, the range of weight variation is
judged to be stable within this setting value
stability;
35
CW-100G (C01+MCGS)
Zero tracking range Weight value within this range, automatically clear zero
Clear range The range at which the scale table is zeroed out during
weighing
Automatic zeroing at Perform zero clearing once the scale platform is started
startup
Check the maximum Is the longest judgment time in the process of weight
calibration, indicating that the weighing platform must be
judgment time of the
stable and the zero voltage must be within the limited range
scale during the calibration of the empty weighing platform and the
weight calibration process. If the above conditions are not met
and the maximum judgment time is exceeded, the alarm will
be given and the weighing will fail
Check scale for When checking the scale, the range of weight variation is
judged to be stable within the stability range of the scale
stability time
Stabilizing time Within this setting, the range of weight variation is judged to
be stable within the range of stability
Zero tracking time During this time, the system data drift does not exceed the
zero tracking range
The system Zero clearing operation will be performed once on the scale
platform
automatically clears
zeros after power-on
Feed to shake time Do not sample during this time after feeding
36
CW-100G (C01+MCGS)
Material blocking time From the discharge photoelectric induction to the material
time, more than this time alarm
Dynamic zero Range of zeroing of the weighing platform during the weight
clearance range checking process
AD sampling rate 120 beats per second 240 beats per second 480 beats per
second
Time between When the system runs to the set value, the photoelectric dust
photoelectric dust removal begins
removal
Buzzer buzzer type There are four types to choose from, which are undererror,
out-of-error, unqualified, and qualified
Buzzer sounding mode There are three ways to choose from, long buzzer, off, and
delay
Over/Under Alarm The pop-up window displays the alarm information when the
Popup Window error is not suspended
37
CW-100G (C01+MCGS)
7. Communication
The product has RS485 and optional network port for external communication. The
communication protocol is standard Modbus RTU, and the network port communication
includes Modbus TCP/IP and HTTP.When the communication mode is printed, RS485 can
be connected to the printer for printing output.For detailed operation methods, refer to
"Operation Instructions on Buttons and Operation Frames" in section 3.3.2.
38
CW-100G (C01+MCGS)
Name Instructions
High and low bytes Bytes of current device communication. Default AB-CD
39
CW-100G (C01+MCGS)
High and low High word first or low word first Facilitate
bytes communication of
various upper
computers
When the host computer communicates with multiple checkweighers at the same time,
the code of each checkweigher device cannot be consistent, and the maximum value is 245
(that is, a single PC can be connected to 245 checkweighers at the same time).
40
CW-100G (C01+MCGS)
⒈ Send: http://IP,
Return: current weigh value (screen display value).
For example:
Send to: http://192.168.61.223
Return: 123.456kg
⒉ Send:
http://IP/szgmt.html
Return: Current weighing value (screen display value).
For example:
Send: http://192.168.10.15/szgmt.html
Return: 123.456kg
⒊ Send:
http://IP/cwrf.html
Return: Current weigh value (screen display value), new weigh data identification.
For example:
Send: http://192.168.10.15/cwrf.html
Return: 123.456kg0 (This value changes from 0 to 1 or from 1 to 0 when there is a
new check result)
⒋ Send:
http://IP/crf.html
Return: New weigh data identification.
Example:
Send to: http://192.168.10.15/crf.html
Return: 1 (change the value from 0 to 1 or from 1 to 0 when there is a new check
result)
41
CW-100G (C01+MCGS)
... reserve
15. Reservations
.0 1: Run 0: Stop
6. 1: Qualified
Module current
40002 0001 7. 1: Busy (for indication)
status 2
8. 1: IO test
9. 1: Belt calibration
11. 1: Feed
12. 1: Discharge
13. 1: Keep
42
CW-100G (C01+MCGS)
... reserve
40539 0538
Out-of-tolerance
40540 0539 ratio
40541 0540
Underdifference
40542 0541 ratio
.1 Busy alarm
43
CW-100G (C01+MCGS)
.18 Reserved
40103 0102
Static weight of the product to be
Product weight
40104 0103 checked
40105 0104
Allowable upper deviation of
Upper limit
40106 0105 product conformity
40107 0106
The permissible lower deviation of
Lower limit
40108 0107 product conformity
40205 0204
Power-on auto Initial value:1
44
CW-100G (C01+MCGS)
40279 0279
Photoelectric
Initial value: 60, range: 60 to 1800
40280 0280 dusting cycle
40501 0500
Qualifying cumulative
40502 0501 count
40505 0504
Cumulative number of
40506 0505 out-of-bounds
40507 0506
Out of tolerance
40508 0507 accumulated weight
40511 0510
Accumulated weight of
40512 0511 underweight
40513 0512
Cumulative number of
40514 0513 disqualifications
40515 0514
Disqualified
40516 0515 accumulated weight
45
CW-100G (C01+MCGS)
40517 0516
Total cumulative times
40518 0817
40521 0520
Maximum
40522 0521
40523 0522
Minimum
40524 0523
40527 0526
Pass rate
40528 0527
40529 0528
All qualified products
40530 0529 are heavy
40533 0532
Underweight products
40534 0533 average weight
40537 0536
Total cumulative
40538 0537 average weight
46
CW-100G (C01+MCGS)
The following is readable bit status (read function code 0x01, write
function code 0x05)
47
CW-100G (C01+MCGS)
----------------------- 上分隔横线符
DATE: 2015.10.15 打印日期
TIME: 15:21 打印时间
PRODUCT CODE: 1 产品号
TARE WT: 0.000kg 皮重值
UP LIM: 0.030kg 超差值
REF WT: 8.135kg 目标值
LOW LIM: 0.030kg 欠差值
PASS CT: 1 合格累计次数
PASS WT: 8.140kg 合格累计重量
PASS AVR: 8.140kg 合格平均重量
PASS RATE: 100.00% 合格率
OVER CT: 0 超差累计次数
OVER WT: 0.000kg 超差累计重量
UNDER CT: 0 欠差累计次数
UNDER WT: 0.000kg 欠差累计重量
TOTAL CT: 1 总累计次数
TOTAL WT: 8.140kg 总累计重量
MIN WT: 8.140kg 最小值
MAX WT: 8.140kg 最大值
----------------------- 上分隔横线符
2. When the communication mode is set to result printing, the device will actively send
data. After each check, it will actively send the content shown in the following figure
through the serial port:
20140503142100 0.0346kg
48
CW-100G (C01+MCGS)
Among:
(2)status ——3 bit,In case of alarm, state 1 is "E" (45H), state 2 and state 3 are
error identifications, otherwise all three bits are spaces 20H.
(3)sign —— 1 bit. Each time there is a new sampling mean, the data mark is
added by 1, from 30H to 39H, and then back to 31H. Used for auxiliary extraction of
sampling data.
(4)limit —— 1 bit is the limit of the current sampling value. The upper limit of the
sampling value is "H" (48H). If the sampling value is qualified, it is "G" (47H). If the lower
limit of the sampling value is "L" (4CH).
(5)Sampling results —— 7-digit weight data (including 6-digit content, 1-digit decimal
point (2EH), if there is no decimal point, the high digit is 20H).If the weight value is 3.75, it
is 30H 30H 30H 33H 2EH 37H 35H.
(7)Unit - 2 digits, "kg (6BH 67H)" for kilogram and "g (67H 20H)" for gram.
(8)CRC - is a checksum, which means that all preceding values are added and
converted to decimal, and then the last two digits are taken and converted to ASCII code.
(9)CR - return sign (0DH).
(10)LF -- Line feed sign (0AH).
Under enable off condition, set F0-01=1, press ENTER to confirm, then the
parameter factory restoration has been completed, do not need to power off
again.
49
CW-100G (C01+MCGS)
2、 Set parameters
b, P7-00 1&2&3, station number (set 1 for input segment, 2 for weight detection
segment and 3 for output segment)
Note: The speed calibration screen needs to set the speed address to: 773
decimal
50
CW-100G (C01+MCGS)
8. Program upgrade
The device can upgrade the motherboard program and touch screen program through
the way of U disk.For details, please refer to "Operation Instructions on Buttons and
Operation Frames" in section 3.3.2.
After contacting our technical department, confirm that it is necessary to upgrade the
program of the motherboard or touch screen.Obtain the corresponding program upgrade
package first.Insert the USB flash drive with the upgrade package, click the "USB flash
Drive Upgrade Controller" button to enter the upgrade interface, and perform the
corresponding program upgrade according to the interface instructions.It is suggested to
upgrade the program of the equipment under the guidance of our technical personnel, so
as to avoid equipment failure or damage.
51
CW-100G (C01+MCGS)
9. Size
When the equipment is installed on site, it is necessary to ensure that there is no
contact between the weighing table and the surrounding area to avoid affecting the normal
weighing. The distance between the surrounding area of the weighing table should be
greater than 10mm.
52
CW-100G (C01+MCGS)
* Note: The width, length and height of the scale stand of non-standard
customized products may be different from that of the standard products. For
details, please refer to the technical documents or drawings confirmed by the
user.
53
CW-100G (C01+MCGS)
54
CW-100G (C01+MCGS)
The sensor is obviously disturbed, such as air conditioning, air flow, etc. Disposal
method to get rid of external interference
Ground shaking, vibration, such as nearby machine rotation interference, cars
passing by, etc.Treatment methods to get rid of external interference
The conveyer belt is affected by viscous objects
Sensor base has debris accumulation or stuck processing method to get rid of
external interference
Filter coefficient set too small processing method to increase the filter coefficient
55