PDIX AccessoriesCatalogue en DIGITAL
PDIX AccessoriesCatalogue en DIGITAL
In addition to digital partial discharge detectors and monitoring systems, Power Diagnostix produces instruments for commissioning
tests on GIS systems, automated control of high voltage tests, fiber optic connections for analogue signal transmission between
instruments and sensors, and for other high voltage applications. All of our instruments and specialised software products are
developed in Aachen, Germany.
At Power Diagnostix, we understand what is essential for the success of your business. That is why we are dedicated to creating,
designing, and manufacturing safe, reliable, easy-to-use test equipment and professional technical services backed by world-
leading support and expertise.
We can assist your acceptance, commissioning, and maintenance testing for predictive, diagnostic, or routine purposes. By
working closely with electrical utilities, standards bodies, and technical institutions, we contribute to the dependability and
advancement of the electrical supply industry.
Our engineers actively participate in regular committees, meetings with all the big trade associations around the world, training
organisations, and government organisations, to understand the needs of electrical contractors. So, when new legislation or rules
are introduced, you can count on Power Diagnostix to put your interests first, because Power Diagnostix products and services
help customers all over the world, improving their efficiency, reducing costs, and meeting standards. It operates globally, with
dedicated field sales teams and distributors located in every continent.
Power Diagnostix is certified according to ISO 9001:2015, ISO 14001:2015, and ISO 45001:2018. We
offer full service, repair, and calibration services accredited to ISO 17025:2018.
www.pdix.com 3
PD accessories
Calibration impulse generators
CAL1 SERIES
Calibrators of the CAL1 series are suitable for calibrating
measurements in high frequency (HF) range. Hence, they can
be used with setups for cable and transformer tests as well
as for measurements on rotating machines and gas insulated
switchgear (GIS), ensuring measurements conform to
IEC 60270. Additionally, they can also be used for time domain
reflectometry (TDR) in cables to determine the cable length and
the location of joints.
CAL2 SERIES
Calibrators of the CAL2 series are signal sources for GIS and
transformer measurements using ultra high frequency (UHF).
To comply with some export restrictions, Power Diagnostix
offers special CAL2 models with a typical rise time of 550 ps.
CAL3 SERIES
Power Diagnostix offers three different models of calibration
impulse generators for RIV measurements: CAL3A, CAL3B,
and CAL3D. They all comply either with NEMA 107‑1987 or
CISPR 18-2.
The appropriate choice of a calibration instrument depends on the range of typical charge values of the partial discharges being
measured.
APPLICATION
CONNECTION
CONNECTOR
COMPLIANT
CAPACITOR
INJECTION
REMARKS/
INCLUDED
IEC 60270
RANGE
TYPE
SET
(CI)
CAL1A 1, 2, 5, 10, 20, 50, 100 pC <1 pF l BNC Cable and transformer tests CAL1-CS1
High level application,
CAL1B 100, 200, 500 pC, 1, 2, 5, 10 nC <100 pF l BNC CAL1-CS1
e.g., rotating machines
Incl. ext. capacitor 100 pF;
CAL1C/100 1, 2, 5, 10, 20, 50, 100 pC* at 100 pF V (50 Ω) l BNC CAL1-CS4
cable tests
1, 2, 5, 10, 20, 50, 100 pC* at 100 pF
Incl. switchable ext. capacitor
CAL1C/1000 10, 20, 50, 100. 200, 500, 1000 pC* at V (50 Ω) l BNC CAL1-CS4
100/1000 pF; cable tests
1000 pF
Laboratory use, transformer
CAL1D 10, 20, 50, 100, 200, 500, 1000 pC <10 pF l BNC CAL1-CS1
tests
CAL1E 0.5, 1, 2, 5, 10, 20, 50 nC <500 pF l BNC
See CAL1B CAL1-CS1
CAL1F 0.2, 0.5, 1, 2, 5, 10, 20 nC <200 pF l BNC
CAL1G 0.02, 0.05, 0.1, 0.2, 0.5, 1, 2 nC <20 pF l BNC Transformer tests CAL1-CS1
GIS, live injection via stray
CAL1H/V(+/S) 0.5, 1, 2, 5, 10, 20, 50 pC* at **pF V (50 Ω) l BNC CAL1-CS5
capacitance
10, 20, 50, 100, 200, 500, 1000 pC* at
Incl. switchable ext. capacitor
CAL1J 100 pF, 100, 200, 500, 1000, 2000, 5000, V (50 Ω) l BNC CAL1-CS4
100pF/1nF; transformer tests
10000 pC* at 1 nF
CAL2B(/500) 2, 5, 10, 20, 30, 40, 50 V (into 50 Ω) V (50 Ω) N
CAL2C(/500) 1, 2, 5, 7, 10, 12, 15, 17, 20 V (into 50 Ω) V (50 Ω) N GIS & UHF CAL2-CS1
CAL2D(/500) 5, 7.5, 10, 15, 20, 30, 40 V (into 50 Ω) V (50 Ω) N
RIV calibration; NEMA 107
CAL3A 600 kHz to 1.35 MHz, 10 µV to 10 mV V (50 Ω) BNC
compliant
RIV calibration; NEMA 107
CAL3B 400 kHz to 1.9 MHz, 10 µV to 10 mV V (50 Ω) BNC CAL3-CS1
compliant
400 kHz to 1.9 MHz, 10 µV to 10 mV RIV calibration; CISPR 18-2
CAL3D V (>20 KΩ) BNC
(into 300 Ω) compliant
* with external high voltage capacitor, ** value to be specified by customer
www.pdix.com 5
PD accessories
Calibration impulse generators
CONNECTION SET CAL1- CAL1- CAL1- CAL1- CAL1- CAL2- CAL2- CAL3- CAL3-
CS1 CS2 CS3 CS4 CS5 CS1 CS3 CS1 CS2
Basic cable set l l l l l l l l
Banana cable, 4 m black l l
Banana cable, 2.5 m black l
RG108 twinaxial cable, 10 m l
T-joint (BNC) l l l
T-joint (N) l
50 Ω termination l l l
N-N adapter l
N-BNC adapter l
ORDERING INFORMATION
Description Order no. Description Order no.
Calibration impulse generator CAL1A PX15000 Connection set CAL1-CS1 for CAL1 PX15024
Calibration impulse generator CAL1B PX15001 Connection set CAL1-CS2 for CAL1 PX15025
Calibration impulse generator CAL1C PX15002 Connection set CAL1-CS3 for CAL1 PX15026
Calibration impulse generator CAL1D PX15003 Connection set CAL1-CS4 for CAL1 PX15027
Calibration impulse generator CAL1E PX15004 Connection set CAL2-CS1 for CAL2 PX15011
Calibration impulse generator CAL1F PX15005 Connection set CAL2-CS3 for CAL2 PX15022
Calibration impulse generator CAL1G PX15006 Connection set CAL3-CS1 for CAL3 PX15028
Calibration impulse generator CAL1H/V PX15039 Connection set CAL3-CS2 for CAL3 PX15029
Switching unit for CAL1H/V PX15040
Calibration Impulse Generator CAL1J PX15016 One standard connection set included with each calibrator!
UHF impulse generator CAL2B PX15009
Options Order no.
UHF impulse generator CAL2B/500 PX15037
50/60 Hz switchable PX15104
UHF impulse generator CAL2C PX15010
Double pulse with adjustable time delay (for CAL1 series) PX15102
UHF impulse generator CAL2C/500 PX15038
Remote power input PX15107
RIV calibration unit CAL3A PX15012
Selection switch for single pulse/continuous PX15101
RIV calibration unit CAL3B PX15013
RIV calibration unit CAL3D PX15020
ULTRASONIC PD SENSORS
Acoustic sensors AS75I and AS150I
The AS75I and AS150I are active sensors with very high
sensitivity for measurements on GIS, transformer tanks, or
cable joints. They come with a built-in 40 dB preamplifier and
can be connected directly to the AIAcompact, ICMsystem,
ICMcompact, and ICMmonitor or to the following preamplifiers:
RPA1D, RPA1F, RPA1G (see page 16).
The TVS2 sensor is used with transformer oil valves. PDIX offers
three standard models for different valve flange diameters:
z TVS2/40, for DN 40
z TVS2/50-80 for DN 50 to DN 80 (diameter 88 to 135 mm)
z TVS2/100 for DN 100
www.pdix.com 7
PD accessories
Partial discharge sensors
CABLE SENSORS
Differential foil sensor DFS1
Besides the embedded coaxial sensor of cable accessories,
external sensors can be applied to joints and terminations.
Especially on cross-bonding joints differential foil sensors serve
to capture partial discharge signals in elevated frequencies.
Such foil sensors can be permanently installed for monitoring
or temporarily applied for survey type measurements.
ORDERING INFORMATION
Description Order no. Description Order no.
Acoustic sensor AS75I PX40100 Transformer valve sensor TVS2/50-80 PX14060
Acoustic sensor AS150I PX40101 Transformer valve sensor TVS2/100 PX14055
Sensor fixture SFX1 PX40102
Sensor fixture SFX2/30 PX40103 Window sensor WS80 PX12063
Sensor fixture SFX2/50 PX40104 Window sensor WS95 PX12060
Sensor fixture SFX3 PX40108 Window sensor WS140 PX12061
External flange sensor EFS1 for permanent installation PX12113
Transformer flange sensor TFS1 PX14056 External flange sensor EFS1 for temporary installation PX12057
Transformer valve sensor TVS2/40 PX14059 Differential foil sensor DFS1 PX12053
Our coupling capacitors are versatile in use and suitable for on-
line and off-line measurements on:
z Medium voltage motors
z Turbine generators
z Hydro generators
z Distribution transformers
www.pdix.com 9
PD accessories
Coupling capacitors
MOUNTING KITS
Save time during installation by using the pre-assembled
ready-made cable sets that are precisely adapted to the use of
the couplers and different mounting requirements.
MOUNTING KIT
MKA MKB MKC MKF
Couplers connected to
Couplers directly Couplers connected to Couplers connected to
busbar with HV cable,
Application bolted to busbar, BNC busbar with HV cable, busbar with HV cable,
BNC connectors,
connectors BNC connectors TNC connectors
gating option
13.8 kV cables, 0.4 m – 3 4 3
RG58, 10 m 3 3 4 3 (*)
BNC connectors incl.
– – – 3
shrink tubings
TNC connectors incl.
– – – 3
shrink tubings
Ground leads, 0.5 m 3 3 4 3
Coupler termination box CTB1A CTB1A CTB2A CTB1C
(*) not pre-assembled
z Coupling capacitor CC7B/R with mounting kit MKA Description Order no.
(including coupler termination box CTB1A) for feed- Coupling capacitor CC7B PX13187
through-mounting in motor termination boxes or direct Coupling capacitor CC7B/R PX13188
mounting to busbar Coupling capacitor CC14B PX13019
Coupling capacitor CC14B/R PX13020
z Coupling capacitor CC14B with mounting kit MKB Coupling capacitor CC20B PX13016
(including coupler termination box CTB1A) for mounting
in motor termination boxes (standard) Coupler termination box CTB1A PX18000
Coupler termination box CTB1C PX18017
z Coupling capacitor CC20B with mounting kit MKC Coupler termination box CTB2A PX18001
(including coupler termination box CTB2A) for use with Coupler termination box CTB2C PX18006
current transformer for noise gating
Mounting kit MKA PX18002
Mounting kit MKB PX18003
Mounting kit MKC PX18007
Mounting kit MKF PX18018
www.pdix.com 11
PD accessories
Coupling capacitors
NOM. VOLTAGE
BUILT-IN RF CT
SYNC. OUTPUT
CAPACITANCE
QUADRUPOLE
BROADBAND
BUILT-IN
TYPE
CC25B/V 1 nF 25 kV 1/250
CC25C/V 1 nF 25 kV 1/250 l
CC35B/V 145 pF 35 kV 1/350
CC50B/V 1 nF 50 kV 1/500
CC50C/V 1 nF 50 kV 1/500 l
CC50D/V 1 nF 50 kV 1/500 l
CC100B/V 1 nF 100 kV 1/1000
CC100D/V 1 nF 100 kV 1/1000 l
CC150B/V 1 nF 150 kV 1/1500
CC200B/V 0.5 nF 200 kV 1/2000
CC300B/V 0.5 nF 300 kV 1/3000
ORDERING INFORMATION
Description Order no. Description Order no.
Coupling capacitor CC25B/V PX13013 Coupling capacitor CC100B/V PX13003
Coupling capacitor CC25C/V PX13014 Coupling capacitor CC100D/V PX13004
Coupling capacitor CC35B/V PX13078 Coupling capacitor CC150B/V PX13001
Coupling capacitor CC50B/V PX13006 Coupling capacitor CC200B/V PX13000
Coupling capacitor CC50C/V PX13007 Coupling capacitor CC300B/V PX13121
Coupling capacitor CC50D/V PX13082
Current transformers (CT) are a low-impact option for sensing Power Diagnostix current transformers are versatile and suitable
partial discharge pulses and sending them as voltage signals for many different test setups. They that can be used with:
to a preamplifier or a pre-processing unit for conditioning. No
z Connecting cables
interruption of the power connection is required. The installation
of a CT is even possible under on-line conditions, since most z Cross link cable boxes
of Power Diagnostix’ current transformers can be opened z Cross link box busbars
and reassembled or clamped around an already existing
connection. z Ground leads
z Medium voltage cables
Providing a galvanic isolation between the PD detector or PD
on-line monitoring system and the high voltage circuit a current z Coupling capacitor terminals
transformer reduces the risk of unwanted damages on the
sensitive measurement equipment.
BANDWIDTH
BANDWIDTH
TRANSFER
PRIMARY
WINDOW
AT -3 DB
AT -6 DB
AT 50 Ω
RATIO
TYPE
ORDERING INFORMATION
Description Order no. Description Order no.
Current transformer CT1 PX12050 Current transformer CT100 PX12051
Current transformer CT40R PX12085 Current transformer CT100R PX12072
Current transformer CT50/10 PX12095 Current transformer CT125 R PX12073
Current transformer CT60R PX12084 Current transformer CT150 R PX12074
www.pdix.com 13
PD accessories
Quadrupoles
ORDERING INFORMATION
Description Order no. Description Order no.
Quadrupole CIL3M PX13120 Quadrupole CIT4M PX13036
Quadrupole CIL4L PX13027 Quadrupole CIT4H PX13038
Quadrupole CIL4M PX13069 Quadrupole CIT5M PX13039
Quadrupole CIL4H PX13029 Quadrupole CIT5H PX12074
Quadrupole CIL5L PX12084 Quadrupole CIT6M PX13042
Quadrupole CIL5M PX13031 Quadrupole CIT6H PX13044
Quadrupole CIL5H PX13032 Quadrupole CIT4M/V2µ0 PX13045
Quadrupole CIL6L PX13166 Quadrupole CIT4M/V2µ0/10µ0/DC PX13066
Quadrupole CIL6M PX13034 Quadrupole CIT5M/V4µ0 PX13094
Quadrupole CIL4M/V1µ0 PX13067 Quadrupole CIT6M/V10µ0 PX13229
Quadrupole CIL4H/V2µ0/4µ0/8µ0/DC PX13181
Quadrupole CIL5M/V4µ0 PX13056
Quadrupole CIL5M/V4µV/8µ0/DC PX13170
Please contact Power Diagnostix in case you need quadrupoles with customer specific values.
www.pdix.com 15
PD accessories
Preamplifiers and pre-processing units
Power Diagnostix provides a complete line of modular units and preamplifiers are remote supplied and remote
preamplifiers and pre-processing units for various testing controlled through a coaxial signal cable. This technique allows
applications. The most significant difference among the placement of these units close to the sensor or signal source
preamplifiers is the frequency range in which they detect and, therefore, provides enhanced over-voltage protection. All
partial discharge signals. Other features that distinguish one preamplifiers of the RPA series can drive a 50 W cable with a
preamplifier from another are: Options for transparency and length of up to 50 m.
on/off switching, unipolar vs.
bipolar charge detection, and Furthermore, as these modules act as impedance converter
the possibiltiy of galvanic and line driver, the weak signal source, such
isolation in the test setup. as voltage divider or coupling
impedance, is not loaded by
All Power Diagnostix external the cable capacitance or
signal conditioning impedance.
RPA1 40 kHz–800 kHz 10 kΩ//50 pF <200 µV 40 dB/Dec l Standard preamplifier for measure-
ments with low frequency range
RPA1D 40 kHz–800 kHz 10 kΩ//50 pF <200 µV 40 dB/Dec l For use with acoustic sensors; built-in
sensor supply, switchable (15/28 V)
RPA1E 40 kHz–800 kHz 10 kΩ//50 pF <200 µV 40 dB/Dec l 0/20 dB attenuation
RPA1F 40 kHz–800 kHz 10 kΩ//50 pF <200 µV 40 dB/Dec l For use with AIAcompact only
RPA1G 40 kHz–800 kHz 10 kΩ//50 pF <200 µV 40 dB/Dec l For use with acoustic sensors; built-in
sensor supply, switchable (Off/15/28 V)
RPA1H 40 kHz–20 MHz 1 kΩ//50 pF <400 µV 40 dB/Dec l MV and HV oil/paper cables, DSO
RPA1L 40 kHz–20 MHz 1 kΩ//50 pF <200 µV 40 dB/Dec l MV and HV cables, DSO
RPA2 2 MHz–20 MHz 50 Ω//50 pF <800 µV 40 dB/Dec On-line measurements on rotating
machines
RPA2B 2 MHz–20 MHz 50 Ω//50 pF <200 µV 40 dB/Dec For use with capacitive sensors on
cables and cable accessories
RPA3 200 MHz–1 GHz 50 Ω//50 pF <300 µV 40 dB/Dec For use with GIS sensors
RPA3D 50 MHz–400 MHz 50 Ω//50 pF <300 µV 40 dB/Dec Nearfield detection
RPA3E 20 MHz–200 MHz 50 Ω//50 pF <300 µV 40 dB/Dec Nearfield detection
RPA4 40 kHz–800 kHz 10 kΩ//50 pF <200 µV 40 dB/Dec l Fibre optic isolation
RPA4H 20 kHz–5 MHz 10 kΩ//50 pF <200 µV 40 dB/Dec l Fibre optic isolation
FCU2 100 MHz–1.8 GHz 50 Ω//50 pF <200 µV 40 dB/Dec Ultra-wide band frequency range;
logarithmic output; GIS sensors
FCU3 100 kHz–50 MHz 50 Ω//50 pF <200 µV 40 dB/Dec For use with cable sensors; logarithmic
output
UHF1B 150 MHz–1 GHz 50 Ω//50 pF – – For use with GIS sensors
UHF1C 300 MHz–1 GHz 50 Ω//50 pF – – For use with GIS sensors
UHF2 300 MHz–2 GHz 50 Ω//50 pF – – For use with GIS sensors
GIS APPLICATIONS
For capturing PD signals with a larger dynamic range, Power
Diagnostix instruments can be ordered with a logarithmic
scaling. For this purpose, the frequency converter unit FCU2
with logarithmic output is required. It covers the range of
100 MHz up to 1.8 GHz and, therefore, is mainly used for
monitoring of gas insulated switchgear (GIS).
ORDERING INFORMATION
Description Order no. Description Order no.
Preamplifier RPA1 PX14000 Preamplifier set UHF1B PX14010
Preamplifier RPA1D PX14003 Preamplifier set UHF1C PX14031
Preamplifier RPA1E PX14004 Preamplifier set UHF2 PX14012
Preamplifier RPA1F PX14005 Frequency converter unit FCU2 (IP52) PX14019
Preamplifier RPA1G PX14024 Frequency converter unit FCU2 (IP65) PX14021
Preamplifier RPA1H PX14002 Frequency converter unit FCU3 (IP52) PX14039
Preamplifier RPA1L PX14001 Frequency converter unit FCU3 (IP65) PX14054
Preamplifier RPA2 PX14006 Input protection unit IPU2B (IP52) PX14020
Preamplifier RPA2B PX14007 Input protection unit IPU2B (IP65) PX14022
Preamplifier RPA3 PX14008
Preamplifier RPA3D PX14049 Options Order no.
Preamplifier RPA3E PX14009 External battery set for preamplifier set RPA4 PX14034
Preamplifier set RPA4 (incl. FO cables) PX14013 External spare battery for preamplifier set RPA4 PX30117
Preamplifier set RPA4 (w/o FO cables) PX14063
Preamplifier set RPA4H (incl. FO cables) PX14051
www.pdix.com 17
PD accessories
Bushing adapters and coupling units
BUSHING ADAPTERS
Power Diagnostix offers various bushing adapters fitting to many two built-in surge arresters (spark gaps) as overvoltage protection
different models of bushing test tabs. Other adapter models are and is available with a stainless steel housing without colouring or
available on request and will be custom made. Every adapter has a housing made of anodised aluminium (ca. RAL 9006).
www.pdix.com 19
PD accessories
Bushing adapter and coupling units
ORDERING INFORMATION
Description Order no. Description Order no.
Bushing adapter BA2, anodised aluminium PX12024 Bushing coupling unit BCU2C, Cd=0.05 µF PX13314-03
Bushing adapter BA2, stainless steel PX12029 Bushing coupling unit BCU2C, Cd=0.05 µF PX13314-04
Bushing adapter BA3, anodised aluminium PX12011 Bushing coupling unit BCU2C, Cd=0.55 µF PX13314-02
Bushing adapter BA4, anodised aluminium PX12018 Bushing coupling unit BCU2C, Cd=0.68 µF PX13268
Bushing adapter BA5, anodised aluminium PX12002 Bushing coupling unit BCU2C, Cd=0.9 µF PX13122
Bushing adapter BA6, anodised aluminium PX12003 Bushing coupling unit BCU2C, Cd=1.5 µF PX13281
Bushing adapter BA7B, anodised aluminium PX12016 Bushing coupling unit BCU2C, Cd=1.6 µF PX13314-01
Bushing adapter BA7C, anodised aluminium PX12035 Bushing coupling unit BCU2D, Cd=0.033 µF PX13258
Bushing adapter BA7C, stainless steel PX12036 Bushing coupling unit BCU2D, Cd=0.04 µF PX13258-01
Bushing adapter BA7D, anodised aluminium PX12090 Bushing coupling unit BCU2D, Cd=0.047 µF PX13258-02
Bushing adapter BA8, anodised aluminium PX12005 Bushing coupling unit BCU2D, Cd=0.056 µF PX13258-03
Bushing adapter BA9, anodised aluminium PX12025 Bushing coupling unit BCU2D, Cd=0.1 µF PX13258-04
Bushing adapter BA9, stainless steel PX12030 Bushing coupling unit BCU2D, Cd=0.12 µF PX13258-05
Bushing adapter BA9B, anodised aluminium PX12039 Bushing coupling unit BCU2D, Cd=0.18 µF PX13258-06
Bushing adapter BA9B, stainless steel PX12040 Bushing coupling unit BCU2D, Cd=0.22 µF PX13258-07
Bushing adapter BA10, anodised aluminium PX12012 Bushing coupling unit BCU2D, Cd=0.25 µF PX13258-08
Bushing adapter BA10B, anodised aluminium PX12047 Bushing coupling unit BCU2D, Cd=0.27 µF PX13258-09
Bushing adapter BA10C, anodised aluminium PX12041 Bushing coupling unit BCU2D, Cd=0.33 µF PX13258-10
Bushing adapter BA10C, stainless steel PX12042 Bushing coupling unit BCU2D, Cd=0.39 µF PX13258-11
Bushing adapter BA10F, anodised aluminium PX12048 Bushing coupling unit BCU2D, Cd=0.4 µF PX13258-12
Bushing adapter BA11, anodised aluminium PX12008 Bushing coupling unit BCU2D, Cd=0.47 µF PX13258-13
Bushing adapter BA12, anodised aluminium PX12009 Bushing coupling unit BCU2D, Cd=0.56 µF PX13258-14
Bushing adapter BA14, anodised aluminium PX12019 Bushing coupling unit BCU2D, Cd=0.68 µF PX13258-15
Bushing adapter BA15, anodised aluminium PX12020 Bushing coupling unit BCU2D, Cd=0.8 µF PX13258-16
Bushing adapter BA17, anodised aluminium PX12032 Bushing coupling unit BCU2D, Cd=0.82 µF PX13258-17
Bushing adapter BA17, stainless steel PX12033 Bushing coupling unit BCU2D, Cd=1.0 µF PX13258-18
Bushing adapter BA18, anodised aluminium PX12013 Bushing coupling unit BCU2D, Cd=1.1 µF PX13258-19
Bushing adapter BA19, anodised aluminium PX12014 Bushing coupling unit BCU2D, Cd=1.2 µF PX13258-20
Bushing adapter BA21, anodised aluminium PX12027 Bushing coupling unit BCU2D, Cd=1.5 µF PX13258-21
Bushing adapter BA21, stainless steel PX12031 Bushing coupling unit BCU2D, Cd=1.8 µF PX13258-22
Bushing adapter BA21B, anodised aluminium PX12028 Bushing coupling unit BCU2D, Cd=2.65 µF PX13243
Bushing adapter BA23, anodised aluminium PX12043 Bushing coupling unit BCU2D, Cd=3.9 µF PX13258-23
Bushing adapter BA23, stainless steel PX12044
Bushing adapter BA25, anodised aluminium PX12037
Bushing adapter BA25, stainless steel PX12038 Options Order no.
Bushing adapter BA27, anodised aluminium PX12045 Stainless steel coupling unit enclosure CUE1 PX12092
Bushing adapter BA27, stainless steel PX12046
Bushing adapter BA28, anodised aluminium PX12109
Bushing adapter BA29, anodised aluminium PX12116
Bushing adapter BA29, stainless steel PX12115
Bushing adapter BA30, stainless steel PX12123
Bushing adapter BA31, anodised aluminium PX12124
Bushing adapter BA32, anodised aluminium PX13317
T-Filters
Power Diagnotix T-filters NAME UN,RMS IN,RMS
are designed to reduce
T30/1 30 kV 1A
high frequent disturbance
T30/5 30 kV 5A
signals from the high
voltage supply. Their main T30/20 30 kV 20 A
application is induced T30/100 30 kV 80 A
voltage testing on motors T50/1 50 kV 1A
and large power transformers. The T50/5 50 kV 5A
standard filters come with B18N T50/20 50 kV 20 A
(multi-contact) connectors, but other
T50/100 50 kV 80 A
connectors are available on request.
T100/1 100 kV 1A
Equipped with a ground plate
on wheels the filters can be T100/5 100 kV 5A
easily moved and are ideal T100/20 100 kV 20 A
for flexible test set-ups. T100/100 100 kV 80 A
HV filters of different ratings (UN, IN) are available on request.
π-Filters
π-Filters are for testing procedures with voltages up to 2 kV.
Standard π-filters are available for three-phase and single-
phase systems, but special models for testing of two phases
are available on request.
www.pdix.com 21
PD accessories
Filters
GROUND FILTER
Partial discharge measurement requires a reasonable
noise-free environment. Power Diagnostix‘ GF50 filter box is
designed to reduce high frequent disturbance signals from
the ground leads. It can be used for HF separation of the test
specimen from the ground potential of the power supply or
other HV equipment within the environment without influencing
the power frequency. The efficiency strongly depends on the
general earthing within the laboratory. A split ground lead or
copper band can be connected to the multi contact connectors
or alternatively to the wing screws beside.
ORDERING INFORMATION
Description Order no. Description Order no.
High voltage filter T30/1 PX10635 1-phase high voltage filter 1Pi2/50 PX16047
High voltage filter T30/5 PX10641 3-phase high voltage filter 3Pi2/20 PX15056
High voltage filter T30/20 PX10629 3-phase high voltage filter 3Pi3/50 PX16035
High voltage filter T30/100 PX10642
High voltage filter T50/1 PX10634 Ground filter GF50 PX90121
High voltage filter T50/5 PX10619
High voltage filter T50/20 PX10636 Accessories Order no.
High voltage filter T50/100 PX10614 Transportation case for T30/x filters PX18119
High voltage filter T100/1 PX10632 High voltage connection cable (length to be specified) PX17097
High voltage filter T100/5 PX16055 Multi-contact male connector for high voltage cables PX17163
High voltage filter T100/20 PX16021 Multi-contact female connector for high voltage cables PX17164
High voltage filter T100/100 PX16010 Red clamp termination for high voltage cables PX17085
Black clamp termination for high voltage cables PX17099
www.pdix.com 23
PD accessories
Miscellaneous
ORDERING INFORMATION
Description Order no.
High voltage transformer HVT15/25 PX50409
High voltage transformer HVT100/10 PX50405
High voltage transformer HVT100/10 PX50260
Control cables for high voltage transformers PX17162
ORDERING INFORMATION
Description Order no.
Transportation case for ICMsystem
with up to 4 channels and accessories PX18126
High transportation case for ICMsystem
with up to 4 channels and accessories PX18122
Transportation case for ICMsystem
with 5 to 10 channels and accessories PX18120
Transportation case for AIAcompact with
desktop housing PX18121
Transportation case for AIAcompact and ICMcompact
with Explorer housing PX18125
Transportation case for ICMcompact with
desktop housing PX18127
Transportation case for GISmonitor Portable PX18123
High transportation case for GISmonitor Portable PX18129
Transportation case for ATTanalyzer PX18124
Transportation case for connection cables PX18111
www.pdix.com 25
PD accessories
Special software
ICMexpert
ICMexpert is a database software for managing partial discharge (PD) patterns
and extends the possibilities of Power Diagnostix programs like ICMcompact,
ICMmonitor, ICMsystem, HVpilot, ICMflex, and GISmonitor. This easy-to-use
tool offers functions for three main tasks occurring regularly when doing PD
measurements:
ICMspectrum
Generally, a spectrum analyser is an excellent tool to identify partial discharge and
noise spectra, as well as the signal to noise ratio. Furthermore, if appropriately
used in zero-span mode, a spectrum analyser offers an oscilloscope-like phase
resolved display. However, as spectrum analysers are designed primarily for
other measurements, they are generally not easy to use.
In order to make it easier to use the analyser, and to remove the hassle of
controlling a multitude of menus and sub-menus, the ICMspectrum software
was created. This software allows full control of analysers of the Agilent/HP
856xE, 859xE, and ESA family as well as the FSL3 (R&S). The software is
reduced to the functions needed for on-site PD testing. It offers convenient data
acquisition and storage. Graphs can be directly pasted into Word documents or
Excel sheets. Screenshots can be taken, stored, and pasted.
Originally, the ICMspectrum software was written for the spectrum analysers of the Agilent 859xE family that is discontinued. Most
of the new spectrum analysers come with a Windows-based operating system, which has an impact on response times and does
not really improve the instruments. However, we have fully integrated the new analysers as well. Thus, the ICMspectrum software
controls the new units via the GPIB interface and offers comparable screenshots regardless the analyser used.
ICMreport
ICMreport is a program for quick and easy creation of reports for insulation
measurements on high voltage (HV) equipment. The software can process data
files resulting from programs such as ICMmonitor, ICMsystem, AIAcompact,
ICMcompact, and GISmonitor. Images of the partial discharge patterns and
the most common values are derived from the measurement data. These
can then be simply dragged and dropped into the report document. Thus, no
programming knowledge is required for report generation.
ICMacoustic
For PD location purposes the ICMacoustic software offers simple and full
control of the FOsystem FOS4 or an oscilloscope of the Tektronix 20xx family.
The software provides a virtual instrument to run the FOS4 or the oscilloscope
under Windows 7, 8, and 10 (32 bit). Critical frequencies can easily be detected
and filters can be set for in-depth analysis.
ORDERING INFORMATION
Description Order no. Description Order no.
Software ICMexpert PX19022 Software ICMreport PX19036
Software ICMspectrum PX19020 Software ICMacoustic PX19008
www.pdix.com 27
Power Diagnostix Systems GmbH
Vaalser Strasse 250, 52074 Aachen, Germany
Tel. +49 241 74927, Fax. +49 241 79521
E-Mail: support(at)pdix.com
www.pdix.com
PDIX_AccessoriesCatalogue_EN_v3_DIGITAL
We reserve the right to make technical changes.
The word ‘Megger’ is a registered trademark. © Copyright 2023