0% found this document useful (0 votes)
33 views1 page

Plumbing Layout 2024 0314 1

The document contains a technical diagram with labels for various pipes and components. Pipes of different diameters like 50mm, 75mm, and 100mm are labeled along with components like risers, valves, and connections. Dimensions and other technical specifications are provided.

Uploaded by

Jhon Bryan Ayes
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
33 views1 page

Plumbing Layout 2024 0314 1

The document contains a technical diagram with labels for various pipes and components. Pipes of different diameters like 50mm, 75mm, and 100mm are labeled along with components like risers, valves, and connections. Dimensions and other technical specifications are provided.

Uploaded by

Jhon Bryan Ayes
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

GL GL 12000 GL GL GL GL 12000 GL GL GL GL GL GL

4050 3900 4050 4050 3900 4050


250 2100 200 1367 250 2100 200 1367 250 2100 200 1367 250 N 250 2100 200 1367 250 2100 200 1367 250 2100 200 1367 250
N
SP RISER 50mm Ø VTR SP RISER 50mm Ø VTR SP RISER 50mm Ø VTR SP RISER 50mm Ø VTR SP RISER 50mm Ø VTR SP RISER 50mm Ø VTR 50mm Ø VTR 50mm Ø VTR 50mm Ø VTR
GL GL GL

250
250
lav. fco lav. fco lav. fco
wc wc wc

150 1400

2400

100mm Ø SP

100mm Ø SP

100mm Ø SP
3500
GL gt gt gt GL GL

2000
75mm Ø SP 75mm Ø SP 75mm Ø SP
UP UP UP

100mm Ø SP

100mm Ø SP

100mm Ø SP
ks ks ks

150
4750

2100
wc wc wc
9900 lav. lav. lav.

11300

50mm Ø VTR

50mm Ø VTR

50mm Ø VTR

50mm Ø VTR

50mm Ø VTR

50mm Ø VTR
7900 co co co

1150 150
UNIT 1 UNIT 2 UNIT 3 DN DN DN
5900

GL GL GL

15000
15000

100mm Ø SP

100mm Ø SP

100mm Ø SP

2850
UNIT 1 UNIT 2 UNIT 3

3800
GL
200

GL GL
2600

1200 200
SEPTIC TANK

SEPTIC TANK

SEPTIC TANK
ds ds ds ds ds ds ds ds ds ds ds ds

5000
5100

CB CB CB CB CB CB 100mm Ø DS 100mm Ø DS 100mm Ø DS 100mm Ø DS 100mm Ø DS 100mm Ø DS

3700
100mm Ø SDP

100mm Ø SDP

100mm Ø SDP

100mm Ø SDP

100mm Ø SDP

100mm Ø SDP

2500
2500
1500

100mm Ø STORM DRAIN PIPE CONNECT 100mm Ø STORM DRAIN PIPE CONNECT 100mm Ø STORM DRAIN PIPE CONNECT 100mm Ø STORM DRAIN PIPE CONNECT
TO MAIN STREET TO MAIN STREET TO MAIN STREET TO MAIN STREET
DRAINAGE LINE 100mm Ø SOIL PIPE DRAINAGE LINE 100mm Ø SOIL PIPE DRAINAGE LINE 100mm Ø SOIL PIPE DRAINAGE LINE
(VERIFY TAPPING POINT) CONNECT (VERIFY TAPPING POINT) CONNECT (VERIFY TAPPING POINT) CONNECT (VERIFY TAPPING POINT)
TO EXISTING MAIN STREET SEWER LINE TO EXISTING MAIN STREET SEWER LINE TO EXISTING MAIN STREET SEWER LINE
(VERIFY TAPPING POINT) (VERIFY TAPPING POINT) (VERIFY TAPPING POINT)

1 GROUND FLOOR SANITARY LAYOUT 2 2ND FLOOR SANITARY LAYOUT 3 DOWN SPOUT AND VENT PIPE LAYOUT
A.200 SCALE 1:100M A.200 SCALE 1:100M A.200 SCALE 1:100M

GL GL 12000 GL GL
GL GL 12000 GL GL
4050 3900 4050
250 2100 200 1367 250 2100 200 1367 250 2100 200 1367 250 4050 3900 4050
N 250 2100 200 1367 250 2100 200 1367 250 2100 200 1367 250
N
gv gv gv
GL LEGEND:
250

GL

250
hb HOSE BIBB
sho

sho

sho
fau

fau

fau
wc

wc

wc
150 1400

hb

hb

hb

fau FAUCET

2400
hb

hb

hb

wc WATER CLOSET
sho SHOWER

3500
GL GATE VALVE
2000

UP UP UP
GL
cv CHECK VALVE
fau fau fau
gv gv gv M WATER METER

150
20mm Ø CWL

20mm Ø CWL

20mm Ø CWL

sho sho sho


9900

LEGEND:

4750

2100
wc wc wc lav LAVATORY
7900

11300
gv
fau
gv
fau
gv
fau fd FLOOR DRAIN

1150 150
wc WATER CLOSET
5900

20mm Ø CWL

20mm Ø CWL

20mm Ø CWL

DN DN DN fco FLOOR CLEAN OUT


GL
15000

GL VTR VENT THROUGH ROOF


UNIT 1 UNIT 2 UNIT 3
15000

SP SEPTIC PIPE
2850

SDP SEWER DRAIN PIPE


UNIT 1 UNIT 2 UNIT 3 DS DOWN SPOUT
3800
200

GL KS KITCHEN SINK
GL
2600

NOTE:
20mm Ø CWL

20mm Ø CWL

20mm Ø CWL

1200 200

RECOMMENDED
BALCONY BALCONY BALCONY SEPARATE SEPTIC
5100

TANK PER UNIT


5000

hb hb hb
3700
2500

2500
1500

cv cv cv
M M M
gv gv gv

25mmØ CWL FROM 25mmØ CWL FROM 25mmØ CWL FROM


MAIN WATER SOURCE MAIN WATER SOURCE MAIN WATER SOURCE

1 GROUND FLOOR WATER LINE LAYOUT 2 2ND FLOOR WATER LINE LAYOUT
A.200 SCALE 1:100M A.200 SCALE 1:100M

ARCHITECT REMARKS ENGINEER PROJECT TITLE AND LOCATION OWNER SHEET CONTENTS PURPOSE OF ISSUANCE SHEET NO.
REPUBLIC ACT 9266
CLARISSE O. QUE GROUND FLOOR PLAN / 2ND FLOOR PLAN FOR QUOTATION
PROPOSED 3-UNIT TOWNHOUSE
PRC NO.: 0034365 TIN: 272720882 SIGNATURE: PRC NO.: TIN: SIGNATURE:
MR. DAVID ROOF PLAN PROJECT NO: 0000 DRAWN BY: MBL A-200
GROUND FLOOR RCP / 2ND FLOOR RCP FILE NAME:
PROJECT MANAGED BY:
0000
0000
DATE:
SCALE:
FEB 16, 2024
1:1
TAQU ARCHITECTS PTR NO.: 0030336 DATE: 01/12/2024 PTR NO.: DATE: NO. 23 LUNAR ROVER ST., MOONWALK VILLAGE BRGY. TALON SINGKO, PAMPLONA, LAS PINAS CITY
DESIGN DEV'T: KTT/COQ PAPER SIZE: 20X30