29PS SERIES | MANUAL RESET

PRESSURE SWITCHES

Introduction
The 29PS Series is a manual reset, single pole, single throw, snap acting pressure switch. The 29PS is based on Sensata Technologies’ 20PS pressure
switch, long recognized as an industry standard control device. Features of this switch include manual reset, a broad assortment of port fittings and
electrical connections, and the option of a panel mount or line mount design.

Sensata Technologies has been a leading global supplier of pressure sensors and switches for over 50 years.

Features
• Manual Reset
• Snap-acting, trip free mechanism
• Single-pole, single-throw switch, normally closed
• Factory calibrated pressure setpoints from 200 to 750 psig (14 to 52
bar)
• Tamper resistant

Applications
The Model 29PS pressure switch is primarily applied as an upper limit
control on unitary and central air conditioning systems, heat pumps, roof
top units, and refrigeration systems.

This hermetic pressure switch employs a trip-free manual reset function,


providing high reliability in an environmentally sealed, low-cost package.

Operation
The 29PS utilizes a snap-acting stainless steel Klixon® disc that reverses its curvature when pressurized above a customer specified actuation pressure.
When the disc snaps, it opens a set of electrical contacts by means of a transfer pin. Resetting of the switch must be accomplished manually by pressing the
integrated reset button.

The unique latching mechanism in the 29PS design assures safe electrical cutout even if the reset button is held firmly depressed.

This “trip-free” design prevents the consumer from restarting the equipment until the line pressure has dropped below the release setpoint. Without this “trip-
free” mechanism, the equipment could be restarted by simply holding the reset button in the depressed position, while an overpressure condition remains.

Product Features
The welded, hermetic design of the 29PS provides increased reliability and maintenance-free operation for the lifetime of the switch. The actuation and release
pressures of the disc are factory calibrated, simplifying installation and making the 29PS tamper resistant.

The epoxy potting and rubber boot provide an environmental seal for the switch mechanism, protecting it from dust, oil and moisture. The 29PS is built into a
vibration resistant package.

Its compact size coupled with a wide variety of threaded and brazed pressure connections allows the 29PS to be mounted wherever is most appropriate for
the application; inside a control box or out in the elements. Panel-mounted devices are typically provided with capillary tubes to allow for convenient access
to the reset button. A variety of line-mounted fittings are available to simplify installation. Many different lead termination options are available for maximum
flexibility.
Page 1

Copyright © 2018 Sensata Technologies, Inc. www.sensata.com


DESIGN SPECIFICATIONS

Operating Pressure 200 to 750 psig (14 to 52 bar)


For actuation pressures of 200-350 psig (14 - 24 bar), tolerance is ±10 psig (±0.7 bar),
60-70% is standard differential;
Proof Differential and Tolerance 351-500 psig (24 - 34.5 bar), ±10 psig (±0.7 bar), 65-75% differential;
Differential = (release setpoint/actuation setpoint) X 100.
Release Tolerance setpoint on all devices (0.2 bar), ±30 psig.
600 psig (41 bar) for actuation pressure up to 400 psig (28 bar);
Proof Pressure 800 psig (55 bar) for higher actuation pressures
Burst Pressure 5000 psig (345 bar)
1/4” SAE female flare with deflator
1/4” male NPTF
Standard Port Fittings 1/8” male NPTF
1/4” SAE male flare
24” and 36” capillary tubes, straight or flared ends
Electrical Configuration Single-pole single-throw normally closed at atmospheric pressure with manual reset
Pilot-duty, 375 VA at 120 VAC 5.8 FLA, 34.8 LRA at 120 VAC
Electrical Ratings 2.9 FLA, 15.0 LRA at 240 VAC 240 VAC 6A IND
Dielectric Strength 750 Vrms across open contacts; 1554 Vrms to ground
Life at Rated Current 10,000 cycles
AWG stranded UL style 1056 with 1/2” strip standard
Leads 6” and 12” lengths standard, other lengths available and special terminals available upon request
Ambient Temperature -20ºF to 150ºF (-29ºC to 66ºC)
Fluid Temperature -65ºF to 275ºF (-54ºC to 135ºC)

TYPICAL DIMENSIONAL DRAWINGS


All dimensions in millimeters [Inches].

Page 2

Copyright © 2018 Sensata Technologies, Inc. www.sensata.com


AGENCY APPROVALS AND CERTIFICATIONS

File No. SA995;


UL U.S. Category SDFY2;
Canada Category SDFY8
ENEC PED CE0035 Module B/D

WARNINGS

HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH


• Disconnect all power before installing or working with this equipment
• Verify all connections and replace all covers before turning on power

Failure to follow these instructions will result in death or serious injury

Page 3

Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that CONTACT US
incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible
for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have Americas
been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that +1 (800) 350 2727
specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, [email protected]
improvements and other changes to its data sheets or components without notice. [email protected]
Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO Europe, Middle East & Africa
OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND +359 (2) 809 1826
NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS [email protected]
ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE Asia Pacific
OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS [email protected]
ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET China +86 (21) 2306 1500
ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD Japan +81 (45) 277 7117
TO SENSATA DATA SHEETS OR USE THEREOF.
Korea +82 (31) 601 2004
All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY
India +91 (80) 67920890
FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY
Rest of Asia +886 (2) 27602006
RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS,
ext 2808
AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION
OR SUPPORT THAT MAY BE PROVIDED BY SENSATA.
Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA.
Rev:06/26/18
Copyright © 2018 Sensata Technologies, Inc. www.sensata.com