DUS-5000+
Digital Color Doppler Ultrasound System
DUS-5000+ Technical Data Sheet
Pediatric
1. General Specification Cephalic
Fetal
The system adopts the advanced ultrasonic
Trans-rectal
Doppler technologies, including the Full Trans-vaginal
Digital Super-wide Band Beam Former,
Digital Dynamic Focusing, Variable Aperture
2.2 Standard Features
and Dynamic Tracing, Wide Band Dynamic
Range, and Multi-Beam Parallel Processing, 2.2.1 Imaging Modes
etc. Users can perform the system with the
B-Mode (B)
minimum requirement of training or
Tissue Harmonic Imaging (THI)
guidance. This system has been designed
Pure Inversion Harmonic Imaging (PIH)
to comply with applicable international Color Flow Mapping (CFM)
standards and regulations, ensuring the Power Doppler Imaging (PDI)
safety and availability of this product. Directional Power Doppler Imaging (DPDI)
Pulsed Wave Doppler (PW)
This system is based on the computer
M-Mode (M)
technology and Linux operation system,
which make the system more flexible and 2.2.2 Functions
stable. System maintenance and function
2D Speckle Reduction & Edge Enhanced (2D
update can be completed by software μ-scan)
updating, through which would promote Spatial Compound Imaging (SCI)
product value and keep the technological PW auto trace
Trapezoid imaging
advancement.
Real-time 2DPanoramic Imaging
Dual Live
Auto (One button optimization for 2D/M/CW / PW)
2. System Overview Image Rotation Function
Auto IMT measurement
2.1 Applications TEI index
Standby mode
Abdominal Biopsy guide
Vascular Full screen zoom
Cardiac Show gallery
GYN/OB DICOM 3.0
Urology Triplex
Musculo-skeletal
Small organ
TDS-DUS5000+
Rev.00
DUS-5000+ Technical Data Sheet
2.3 Optional Features Anti-flickering
3.3 Probe Sockets and Holders
VIS-Needle (Needle Visualization Enhancement )
Panoramic Imaging (Real-time 2D) Probe Sockets:3 probe sockets (Only 2 active for
Tissue Doppler Imaging (TDI) standard) and 3 holders
SR Flow Imaging
Color M mode (CFM+M)
3.4 Operation Environment
Anatomic M-Mode (AMM, Steer M)
Lateral Gain Compensating (LGC)
Temperature: +10°C-+40°C
Continuous Wave Doppler (CW)
Relative Humidity: 30% -85% (no condensation)
Wi-Fi (DICOM)
Atmospheric Pressure: 700-1060hPa
B/I Box Extender with ECG
B Mode Prospective Saving
3.5 Transportation and Storage
Environment
2.4 Language Support
Temperature: -20°C - +55°C
Software:
Relative Humidity: 20%-90% (no condensation)
English, Simple Chinese, Spanish, Russian,
Atmospheric pressure: 700-1060hPa
French, German, Portuguese, Italian, Norwegian
Keyboard Input:
3.6 Power Supply
Danish, Swedish, Finnish, Portuguese, German,
Spanish, French, Portuguese, Turkish.
AC/DC Adaptor:
Additional Requirement: Russia.
Input: 100-240Va.c., 1.5-0.75A, 50-60Hz;
Output: 19Vd.c., 4.74A
3. Physical Specification
Main unit: 19Vd.c., 4.74A
3.1 Dimensions and Weight
Height: 352mm
4. Imaging Parameters
Width: 378mm
Depth: 114mm
4.1 B-Mode
Weight: approx. 6.1kg (without battery)
approx. 6.5kg (with battery) Display Format: B, Dual (B+B), Quad (4B)
Gain: 1-255 adjustable
3.2 Monitor
Frame Rate: up to 80 fps (Probe dependent)
Gray Shades: 256
15.6-inch widescreen and high resolution color
Scan Depth: 40.0 cm (Probe dependent)
LCD monitor
Image Zoom (Ratio: 0.8-10 times)
Resolution: 1920*1080
TDS-DUS5000+
Rev.00
DUS-5000+ Technical Data Sheet
TGC: 8-level slides, adjustable Optimization)
LGC Left & LGC Right: adjustable
Image Flip: Left/ Right, Up/Down 4.2 Color/PDI
Panoramic: available
Gain: 0-255
Compound Imaging: Off, 1, 2, 3,4 (Probe
Frame Rate: up to 209 fps (Probe dependent)
dependent)
Size and Position of Color ROI: adjustable
PHI/THI: On/Off
Image Flip: Up/Down, Left/Right
Frequency: 5 bands, adjustable
Frequency: 3 levels, adjustable
Chroma: 12 types, selectable
Wall Filter: 5 levels, Min, Low, Med, High, Max
μ-Scan: Off,1,2,3,4,5 adjustable
adjustable (Probe dependent)
Line Density: 3 levels, adjustable
PRF: 0.5-10kHz (Probe dependent)
(High/Medium/Low)
Line Density: 4 levels (Min/Low/ Med/ High)
Persist: Off, Low, Med, High, Max 4 levels ,
Color Map: 1-5 levels for CFM mode
adjustable
Persist: 4 levels, Off/Low/Med/High/Max
Biopsy Guide: Off/On (preset adjustable)
adjustable (Probe dependent)
Dot Size: Min, Med, Max, 3 levels adjustable
B Reject: 0-255 adjustable
Biopsy Calibration
Steer: 0°, ±8, ± 12°, ± 16°adjustable
Angle adjustable
PDI: On/Off
Offset adjustable
Color Map (PDI)/DPDI: 7 types selectable, former
Save
for PDI, latter for DPDI (Probe dependent)
Load Default
Dual Live: On/Off
Dynamic Range (DYN): 20-200 (Probe
Invert: On/Off
dependent)
Gray Map: 16 levels, selectable (Probe
dependent) 4.3 M-Mode
Sector Width: adjustable
Focus Position: adjustable AMM: On/Off, 3 sample lines
Focus area 1 -21 Frequency: 5 levels, adjustable
Power%: 1-100 adjustable, 5 step each Gray Map: 16 types, selectable
Tissue Specific Imaging (TSI): Adipose, Muscle, Chroma: 12 types, selectable
Fluid, Normal tissue Display Format: V2/1, V1/1, V1/2, H1/1, Full
Widescan: Off/On Sweep Speed: 5 levels adjustable for M mode
Steer: 0, ±2°, ± 4°, ±6°degrees, adjustable (Min/ Slow/ Med/ Fast/ Max), and 5 levels
Rotation: Off/ 90°/ 180°/ 270° adjustable for AMM (Min/ Slow/ Med/ Fast/ Max)
Vis-Needle AMM Power%: 1-100, adjustable
On/Off Focus area 1-21 levels, adjustable
Steer Angle Persist: Low, Med, High, Max 4 levels, adjustable
Dual Live: On/Off Power:1-100%, selectable
Auto (One-button B-mode Parameter
TDS-DUS5000+
Rev.00
DUS-5000+ Technical Data Sheet
4.4 PW/CW Mode Auto focus
Inversion: On/Off
Doppler Methods
Power: 1% - 100%
PW Doppler
Frequency range: 3 steps, adjustable
CW Doppler
PRF: 0.5 - 10KHz (probe dependent)
Simult: On/Off
Line density: Low, Med, High adjustable
Sample Volume (PW): 0.5-24.0 mm, adjustable
Color Map: 10 levels
Position: adjustable
Dual Live: On/Off
Invert: On/Off
Flow Reject: 1 - 255
Quick Angle: 0°, 60°, -60°, adjustable
θ Correction: θ angle correction: -88°to 88°, 2°
steps each 5. System Setting
(Real-time) Auto Trace: On/Off
Baseline: 9 levels, adjustable 5.1 General
Frequency: 3 levels, adjustable
Wall Filter: 5 levels, Min, Low, Med, High, Max, 5.1.1 General Settings
adjustable
Hospital Name
PRF: 1-16 kHz (PW) (Probe dependent)
Freeze Response: Cine, Annot, Body
PRF: 1-50KHz (CW) (Probe dependent)
mark, Arrow
Max Velocity Range
Trackball Sensitivity: 1, 2, 3, 4, 5
±0.0576 - ±6.14m/s (PW) (probe
Language: English, Simplified Chinese,
dependent, sampling angle range: ±60°)
Spanish, Russian, French, Italian,
±0.0761 - ±10.35m/s (CW) (probe
Germany, Norwegian Portuguese
dependent, sampling angle: 0)
Time Zone
Sweep Speed: 5 levels, adjustable (Min/ Slow/
Date/Time Setting
Med/ Fast/ Max)
Date Format: MM/DD/YYYY,
Chroma: 12 types, selectable
YYYY/MM/DD, DD/MM/YYYY, selectable
Display Format: V2/1, V1/1, V1/2, H1/1, Full,
Time Format: 12 Hour, 24 Hour, selectable
Steer: 4 levels: 0°, ± 8°,± 12°, ± 16°, adjustable
Volume: 0-100, 5 each step, adjustable
5.1.2 Display
Power:1-100%
Auto (One-button Parameter Optimization) Screen Saver: On/ Off
Baseline Screen Saver wait (min): 5-60 minutes
PRF Auto standby wait (min): 20-90 minutes
Key Volume: On/Off
Keyboard & Monitor Brightness
4.5 Tissue Doppler Mode (TDI) Monitor Colors: Warm/Cool
Gain: 0 - 255 Width Ruler: On/Off
Frame rate: 121 fps (probe dependent) Trackball Light Color: 6 types
Size and position of color ROI: adjustable Show Gallery
TDS-DUS5000+
Rev.00
DUS-5000+ Technical Data Sheet
Config.: Top, up, down, bottom
Play Interval:1-5 seconds, selectable
Import 5.3 Comment
Delete
Load Default 5.3.1 Tools
Exit Annotation
Select annotation Language
5.1.3 Save
Font size
Retrospective store Clear annotation while unfreezing
Prospective store image
Freeze Store Arrow
Save Format/Area Arrow size: Large/Medium/Small
Cine Format: AVI, W MV Clear arrow while unfreezing image: On/Off
Image Format: BMP, JPG, TIF
Area: Full Screen, Image Area, Image 5.3.2 List
area+InfoBar
Classified by specific exams: Abdomen,
Save Operation
Obstetrics, Gynecology, Vascular, Breast,
Send image to DICOM storage
Cardiology, Urology, Small parts, Musculoskeletal
Send cine to DICOM storage
Edit comment item
Key Function
Add to Library
P1,P2,F3,F4, Cine
Delete
Selected (Comment List):
5.1.4 Biopsy
To first
Biopsy Guide Line Previous
Bracket Next
Guide line type: Line, Range To Last
Guide line display: On/Off
5.4 Bodymark
DICOM Print
Biopsy Grid
Classified by specific exams: Abdomen,
Biopsy Grid Display Style: +/.
Obstetrics, Gynecology, Vascular, Breast,
Biopsy Grid Display Color:
Cardiology, Urology, Small Parts, Musculoskeletal
Green/Yellow
5.2 Exam Preset
Probe Selection
Available Items
Selected Items
TDS-DUS5000+
Rev.00
DUS-5000+ Technical Data Sheet
5.5 Measure CUA
Equation (SMP)
5.5.1 General Thyroid (Volume) Calculation Coefficient: 0.52
(US). 0.479 (EURO), selectable
BSA (Body Surface Area): Eastern, Western Load default
Cross Cursor Size: Small, Medium, Large,
selectable 5.5.3 List
Measure Line Size: Small, Medium, Large
Distance Dash Line Display: On/ Off For editing measure lists classified into different
Velocity Cross Line Display: On/ Off applications, categories and modes.
Ellipse Cross Line Display: On/ Off
Volume Flow Method: TAmean/TAmax Application: Abdomen, Urology, Small parts,
Volume Flow compensation with TAmax 0.5 – Gynecology, Obstetrics, Vascular, Cardiology,
Pediatrics, selectable
1.0
Measurement Categories: Caliper, Calculation,
Keep Result Window : On/ Off
selectable
Result Font Color: W hite/Yellow
Mode: B, Color, M, Doppler, selectable
Result Position:
List (items): Category, Collection, Measurement
2D: Right Top, Right Bottom, Left Top, Left
Measurement (Adjust Position): Add, Delete,
Bottom, selectable
Reorder
M+D: Right Top, Right Bottom, Left Top,
Load default
Left Bottom, selectable
5.5.2 Application 5.6 Report
Auto/ Manual Trace: Abdomen, Urology, Small Logo
Parts, Gynecology, Obstetrics, Vascular, Cardiac, Operation LOGO: Upload logo
selectable Left/Right: Choose logo
Num 0-9: Editable shortcut keys of measurement Title/Font/Color:
(OB/GYN//Cardiac) Title 1/ Title 2/ Title 3
Measurement Setting (OB) Title 1/ Title 2/ Title 3/ Title/
CUA/AUA SubTitle/Content
Add 1 week to EDD (Yes/ No) Font Size: 14-26, adjustable, 2 each
Show EDD on screen (Yes/ No) step
Growth Deviation Display: No, %, SD, Content Font Size: 12-16,adjustable, 1
selectable each step
Equation (OB) Background Color: Basic Colors (48 types),
GA & Growth (New Table): New GA Table, Screen Color
New Growth Table Text Color: Basic Colors (48 types), Screen
Fetal Weight: Estimation, Age by EFW, Color
EFW GP/SD, Unit Display Items for Report:
TDS-DUS5000+
Rev.00
DUS-5000+ Technical Data Sheet
Patient Information Advance (Advanced Setting)
Exam Information Network Name
Measurements (selectable) Signal Level
Image (selectable): 1*1, 2*2, 3*3, Encryption
selectable DHCP/Static IP (IP Address, Netmask,
Graphs (selectable) Default Gateway)
Comment (selectable)
Preview
5.8 DICOM
5.7 Peripheral
5.8.1 Local Setting
5.7.1 Basics
Local Device
Video output
Station Name
Area: Picture
AE Title
area/FullScreen/Info+PictureArea
Port Number
CVBS/S-VIDEO: NTSC/PAL/Close
Timeout(sec)
HDMI: Close/1920*1080 Storage Setting:
Printer 2D Compression:None/RLE/JPEG
Default Printer: USB Printer/Windows 2D JPEG Quality
Printer Cine Compression:None/RLE/JPEG
Printer IP Address Cine JPEG Quality
Send at end of exam: On/Off
Printer Port Number
Foot Switch 5.8.2 DICOM Service
Left/Right Key
Service List:
5.7.2 Network Service Type
Service Name
Local Network AE Title
DHCP/Static IP IP Address
DHCP: MAC Address Port
Static IP: IP Address, Netmask, Default
Gateway, Mac Address 5.9 Help
Ping IP Address
Wireless Network (Enable/Disable): User manual
List (Name, State, Level)
Connect
Disconnect
Refresh
TDS-DUS5000+
Rev.00
DUS-5000+ Technical Data Sheet
B+CFM+M
5.10 Load Default Anatomical M mode
5.10.1 Load 7. Connections
5.10.2 New: 7.1 Ethernet Network
StoreName
7.2 USB
Replace
New USB 2.0: 3 ports
5.10.3 Export/Import:
7.3 Wireless Network
USB Drive
7.4 DICOM 3.0
Copy user setting to USB
Copy user preset to USB
Storage: directly transmits images with patient
Load USB user setting to system
information to a DICOM file server
Load USB user preset to system
Medical digital images and communication
Export Log
DICOM 3.0 interface
5.11 About
8. Optional Transducers
General: System information
8.1 Phased Array Probe
6. Display Formats
3P-A
B+B Frequency: 1.0 - 6.0MHz
4B 7P-B
B + CFM
Frequency: 2.0 - 9.0MHz
B + PDI
B+DPDI
B+TDI
8.2 Linear probes
B+M
B+PW L741
B+CFM+PW
Frequency: 4.0 - 16.0MHz
B+PDI+PW
10I2
B+DPDI+PW
B+TDI+PW Frequency: 4.0 - 16.0MHz
B+CW L746
B+CFM+CW Frequency: 4.0 - 12.0MHz
B+PDI+CW
TDS-DUS5000+
Rev.00
DUS-5000+ Technical Data Sheet
8.3 Convex probes 10. Image/ Patient Data
3C-A
Management
Frequency: 1.0 - 7.0MHz
6V1 Static and Dynamic image storage
Frequency: 3.0 - 15.0MHz Support review of past exam by clipboard
Patient Registration: Name, ID, Gender, Date of
C361
Birth, Height, Weight, LMP, EDD and GA.
Frequency: 2.0 - 6.0MHz
Patient data and reports are archived by patient
C613 exams
Frequency: 4.0 - 13.0MHz Reports and images can be previewed
EC9-5 Preview size can be set to 1*1, 2*2,
File can be previewed, deleted, used for DICOM
Frequency: 3.0 - 15.0MHz
Send and DICOM Print or exported
9. Safety and Conformance Files can be exported to the USB drive or DVD.
BMP, JPG, TIF, AVI, W MV, PDF, TXT are
9.1 Quality Standard
selectable for export format.
ISO 9001
ISO 13485 11. Preset Function
9.2 Safety Standard Users can customize the presets based on
different probe and diagnostic part to optimize
Comply with IEC 60601-1, Class I BF, imaging parameters
Comply with IEC 60601-1-2, Group 1,
Users can arrange the presets
Class B Comply with IEC 60601-2-37
Users can import or export presets (not including
default preset)
TDS-DUS5000+
Rev.00
NOTE:
The specifications of this system m ay change without any prior notification.
Some products or features may not be available in some countries.
Please contact your local Advanced Instrumentations sales representative for m ore
information.
TDS-DUS5000+
Rev.00
6800 N.W. 77th Ct
Miami, Fl 33166
Teléfono: 305- 477-6331
Fax: 305-477-5351
Website: www.advanced-inst.com
e-mai: [email protected]