TEST REPORT
Applicant Name : PO FUNG ELECTRONIC(HK) INTERNATIOANL GROUP COMPANY
LIMITED
Address : Room 1508, 15/F, Office Tower II, Grand Plaza, 625 Nathan Road,
Kowloon, Hong Kong
Report Number : XMTN1211208-63393E-01
FCC ID: 2AJGM-UV16R
Test Standard (s)
FCC PART 15B
Sample Description
Product Type: Amateur Radio
Model No.: UV-16R
Multiple Model: UV-16S, UV-16X, UV-16Plus, UV-16Pro, UV-16
Trade Mark: BAOFENG, POFUNG
Date Received: 2021-12-08
Date of Test: 2021-12-14 to 2021-12-20
Report Date: 2021-12-24
Test Result: Pass*
* In the configuration tested, the EUT complied with the standards above.
Prepared and Checked By: Approved By:
Black Ding Candy Li
EMC Engineer EMC Engineer
Note: This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “★”.
Shenzhen Accurate Technology Co., Ltd. is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant
that may affect test results are marked with an asterisk ’*’. Customer model name, addresses, names, trademarks etc. are not considered data.
This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report
refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software
above version 7.0.
Shenzhen Accurate Technology Co., Ltd.
1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China
Tel: +86 755-26503290 Fax: +86 755-26503396 Web: www.atc-lab.com
Version 59 2021-11-09 Page 1 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
TABLE OF CONTENTS
GENERAL INFORMATION .......................................................................................................................................3
PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................3
OBJECTIVE ...................................................................................................................................................................3
RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
TEST METHODOLOGY ..................................................................................................................................................3
MEASUREMENT UNCERTAINTY ....................................................................................................................................4
TEST FACILITY .............................................................................................................................................................4
SYSTEM TEST CONFIGURATION ..........................................................................................................................5
JUSTIFICATION .............................................................................................................................................................5
EUT EXERCISE SOFTWARE ..........................................................................................................................................5
SPECIAL ACCESSORIES .................................................................................................................................................5
EQUIPMENT MODIFICATIONS .......................................................................................................................................5
SUPPORT EQUIPMENT LIST AND DETAILS ....................................................................................................................5
BLOCK DIAGRAM OF RADIATED TEST SETUP...............................................................................................................6
SUMMARY OF TEST RESULTS ...............................................................................................................................8
TEST EQUIPMENT LIST ...........................................................................................................................................9
FCC §15.107 – CONDUCTED EMISSIONS ............................................................................................................10
APPLICABLE STANDARD ............................................................................................................................................10
EUT SETUP ................................................................................................................................................................10
EMI TEST RECEIVER SETUP .......................................................................................................................................10
TEST PROCEDURE ......................................................................................................................................................11
FACTOR & OVER LIMIT CALCULATION ......................................................................................................................11
TEST DATA ................................................................................................................................................................11
FCC §15.109 - RADIATED EMISSIONS .................................................................................................................14
APPLICABLE STANDARD ............................................................................................................................................14
EUT SETUP ................................................................................................................................................................14
EMI TEST RECEIVER SETUP .......................................................................................................................................15
TEST PROCEDURE ......................................................................................................................................................15
FACTOR & OVER LIMIT CALCULATION – FOR BELOW 1GHZ.....................................................................................15
TEST DATA ................................................................................................................................................................16
FCC §15.111 - ANTENNA CONDUCTED POWER FOR RECEIVERS ..............................................................60
APPLICABLE STANDARD ............................................................................................................................................60
EUT SETUP ................................................................................................................................................................60
TEST PROCEDURE ......................................................................................................................................................60
TEST DATA ................................................................................................................................................................60
FCC §15.121(B) - SCANNING RECEIVERS AND FREQUENCY CONVERTERS USED WITH SCANNING
RECEIVERS ................................................................................................................................................................63
APPLICABLE STANDARD ............................................................................................................................................63
EUT SETUP ................................................................................................................................................................63
TEST PROCEDURE ......................................................................................................................................................63
TEST DATA ................................................................................................................................................................64
Version 59 2021-11-09 Page 2 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
GENERAL INFORMATION
Product Description for Equipment under Test (EUT)
Product Amateur Radio
Tested Model UV-16R
Multiple Model UV-16S, UV-16X, UV-16Plus, UV-16Pro, UV-16
Model Difference Please refer to the DoS letter
RX: 136-174MHz, 400-520MHz(Scanning receiver)
Frequency Range
FM: 76-108MHz(Receiver)
Highest Operation
520 MHz (provided by the applicant.)
Frequency
Voltage Range DC 5V from Adapter or DC 7.4V from battery
Sample number XMTN1211208-63393E-RF-S1 (Assigned by ATC)
Sample/EUT Status Good condition
Model: BF-0502000
Adapter information Input: AC 100-240V, 50/60Hz, 0.5A
Output: DC 5V, 2.0A
Objective
This report is in accordance with Part 2-Subpart J, and Part 15-Subparts A and B of the Federal
Communication Commission’s rules.
The objective of the manufacturer is to determine the compliance of EUT with FCC Part 15, Class B
device.
Related Submittal(s)/Grant(s)
No related submittal(s).
Test Methodology
All measurements contained in this report were conducted with ANSI C63.4-2014, American National
Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and
Electronic Equipment in the range of 9 kHz to 40 GHz.
All radiated and conducted emissions measurement was performed at Accurate Technology Co., Ltd. The
radiated testing was performed at an antenna-to-EUT distance of 3 meters.
Version 59 2021-11-09 Page 3 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Measurement Uncertainty
Parameter Uncertainty
Occupied Channel Bandwidth 5%
RF Frequency 0.082*10-7
RF output power, conducted 0.73dB
Unwanted Emission, conducted 1.6dB
AC Power Lines Conducted Emissions 2.72dB
9kHz - 30MHz 2.66dB
30MHz - 1GHz 4.28dB
Emissions,
1GHz - 18GHz 4.98dB
Radiated
18GHz - 26.5GHz 5.06dB
26.5GHz - 40GHz 4.72dB
Temperature 1℃
Humidity 6%
Supply voltages 0.4%
Note: The extended uncertainty given in this report is obtained by combining the standard uncertainty times the
coverage factor K with the 95% confidence interval. Otherwise required by the applicant or Product Regulations,
Decision Rule in this report did not consider the uncertainty.
Test Facility
The test site used by Shenzhen Accurate Technology Co., Ltd. to collect test data is located on the 1/F., Building
A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R.
China.
The test site has been approved by the FCC under the KDB 974614 D01 and is listed in the FCC Public Access
Link (PAL) database, FCC Registration No.: 708358, the FCC Designation No.: CN1189.
Accredited by American Association for Laboratory Accreditation (A2LA) The Certificate Number is 4297.01.
Listed by Innovation, Science and Economic Development Canada (ISEDC), the Registration Number is
5077A.
Version 59 2021-11-09 Page 4 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
SYSTEM TEST CONFIGURATION
Justification
The system was configured for testing in a typical fashion (as normally used by a typical user).
Test mode 1: Charging
Test mode 2: Scanning receiver
Test mode 3: Receiver at FM 76MHz
Test mode 4: Receiver at FM 92MHz
Test mode 5: Receiver at FM 108MHz
Test mode 6: Receiver at 136MHz
Test mode 7: Receiver at 155MHz
Test mode 8: Receiver at 174MHz
Test mode 9: Receiver at 400MHz
Test mode 10: Receiver at 460MHz
Test mode 11: Receiver at 520MHz
EUT Exercise Software
No exercise software.
Special Accessories
No special accessory was used.
Equipment Modifications
No modification was made to the EUT tested.
Support Equipment List and Details
Manufacturer Description Model Serial Number
AGILENT Vector Signal Generator N5182A MY50143401
External I/O Cable
Cable Description Length (m) From Port To Port
Unshielded Detachable DC power Cable 1.0 Adapter EUT
Unshielded Detachable Earphone Cable 1.2 EUT Earphone
Version 59 2021-11-09 Page 5 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Block Diagram of Radiated Test Setup
For conducted emission:
AC Mains:
Test Mode 1:
Adapter
LISN
EUT
10cm
Receptacle
1.0 Meter
Earphone
Non-Conductive Table
80 cm above Ground Plane
1.5 Meters
Version 59 2021-11-09 Page 6 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
For Radiated emission:
Test mode 1:
AC Mains
Adapter
EUT
10cm
Receptacle
1.0 Meter
Earphone
Non-Conductive Table
80 cm above Ground Plane
1.5 Meters
Test mode 2-11:
Signal Generator
Antenna
1.0 Meter
EUT
Earphone
Non-Conductive Table
80 cm above Ground Plane
1.5 Meters
Version 59 2021-11-09 Page 7 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
SUMMARY OF TEST RESULTS
FCC Rules Description of Test Results
§15.107 Conducted Emissions Compliant
§15.109 Radiated Emissions Compliant
§15.111 Antenna Conducted Power for receivers Compliant
Scanning receivers and frequency converters used with
§15.121(b) Compliant
scanning receivers
Version 59 2021-11-09 Page 8 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
TEST EQUIPMENT LIST
Calibration Calibration
Manufacturer Description Model Serial Number
Date Due Date
Conducted Emissions Test
Rohde& Schwarz EMI Test Receiver ESCI 100784 2021/02/03 2022/02/02
R&S L.I.S.N. ENV216 101314 2020/12/25 2021/12/24
Anritsu Corp 50Ω Coaxial Switch MP59B 6200506474 2020/12/25 2021/12/24
Unknown RF Coaxial Cable No.17 N0350 2020/12/25 2021/12/24
Conducted Emission Test Software: e3 19821b(V9)
Radiated Emissions Test
Rohde& Schwarz Test Receiver ESR 102725 2020/12/25 2021/12/24
Rohde&Schwarz Spectrum Analyzer FSV40 101949 2021/5/18 2022/5/17
A.H. Systems, inc. Preamplifier PAM-0118P 531 2021/11/9 2022/11/8
SONOMA
Amplifier 310 N 186131 2020/12/25 2021/12/24
INSTRUMENT
Schwarzbeck Bilog Antenna VULB9163 9163-323 2020/01/05 2023/01/04
Schwarzbeck Horn Antenna BBHA9120D 9120D-1067 2020/01/05 2023/01/04
Unknown RF Coaxial Cable No.10 N050 2021/12/14 2022/12/13
Unknown RF Coaxial Cable No.11 N1000 2021/12/14 2022/12/13
Unknown RF Coaxial Cable No.12 N040 2021/12/14 2022/12/13
Unknown RF Coaxial Cable No.13 N300 2021/12/14 2022/12/13
Unknown RF Coaxial Cable No.14 N800 2021/12/14 2022/12/13
HPM-1.2/18G
CD High Pass Filter 110 2020/12/25 2021/12/24
-60
Radiated Emission Test Software: e3 19821b(V9)
RF Conducted Test
Rohde&Schwarz Spectrum Analyzer FSV40 101949 2021/05/18 2022/05/17
Vector Signal
AGILENT N5182A MY50143401 2021/01/04 2022/01/03
Generator
30dB Attenuator
Aeroflex/Weinschel (Input 250W/Output 58-30-33 PS467 2020/12/25 2021/12/24
50W)
RF Communication
HP Agilent 8920B 3325U00859 2021/03/15 2022/03/15
test set
* Statement of Traceability: Shenzhen Accurate Technology Co., Ltd. attests that all calibrations have been
performed in accordance to requirements that traceable to National Primary Standards and International System of
Units (SI).
Version 59 2021-11-09 Page 9 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
FCC §15.107 – CONDUCTED EMISSIONS
Applicable Standard
According to FCC§15.107
EUT Setup
The measurement procedure of EUT setup is according with ANSI C63.4-2014. The related limit was
specified in FCC Part 15.107 Class B.
The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the
middle.
The spacing between the peripherals was 10 cm.
EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.
During the conducted emission test, the EMI test receiver was set with the following configurations:
Frequency Range IF B/W
150 kHz – 30 MHz 9 kHz
Version 59 2021-11-09 Page 10 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Test Procedure
Maximizing procedure was performed on the six (6) highest emissions of the EUT.
All final data was recorded in the Quasi-peak and average detection mode.
Factor & Over Limit Calculation
The Transd factor is calculated by adding LISN VDF (Voltage Division Factor) and Cable Loss. The basic
equation is as follows:
Transd Factor = LISN VDF + Cable Loss
The “Over limit” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, an Over limit of -7 dB means the emission is 7 dB below the limit. The equation for
calculation is as follows:
Over Limit = Level – Limit
Level = Read Level + Factor
Test Data
Environmental Conditions
Temperature: 25 ℃
Relative Humidity: 49 %
ATM Pressure: 101.0 kPa
The testing was performed by Bin Duan on 2021-12-14.
Version 59 2021-11-09 Page 11 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Test mode 1:
AC 120V/60Hz, Line:
Version 59 2021-11-09 Page 12 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
AC 120V/60Hz, Neutral:
Version 59 2021-11-09 Page 13 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
FCC §15.109 - RADIATED EMISSIONS
Applicable Standard
FCC §15.109
EUT Setup
Below 1GHz:
Above 1GHz:
Version 59 2021-11-09 Page 14 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
The radiated emission tests were performed in the 3 meters chamber test site, using the setup accordance
with the ANSI C63.4-2014. The specification used was the FCC Part 15.109 Class B limits.
The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the
middle.
The spacing between the peripherals was 10 cm.
EMI Test Receiver Setup
The system was investigated from 30 MHz to 5 GHz.
During the radiated emission test, the EMI test receiver was set with the following configurations:
Frequency Range RBW Video B/W IF B/W Detector
30MHz – 1000 MHz 120 kHz 300 kHz 120kHz QP
1MHz 3 MHz / Peak
Above 1 GHz
1MHz 3 MHz 1MHz Ave.
Test Procedure
Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.
All data was recorded in the Quasi-peak detector mode from 30 MHz to 1 GHz, Peak and average
detection mode above 1 GHz.
If the maximized peak measured value complies with the limit, then it is unnecessary to perform
QP/Average measurement.
Factor & Over Limit Calculation
The Factor is calculated by adding the Antenna Factor and Cable Loss, and subtracting the Amplifier Gain. The
basic equation is as follows:
Factor = Antenna Factor + Cable Loss - Amplifier Gain
The “Over Limit/Margin” column of the following data tables indicates the degree of compliance with the
applicable limit. For example, an Over Limit/margin of -7dB means the emission is 7dB below the limit. The
equation for calculation is as follows:
Over Limit/Margin = Level / Corrected Amplitude – Limit
Level / Corrected Amplitude = Read Level + Factor
Version 59 2021-11-09 Page 15 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Test Data
Environmental Conditions
Temperature: 25℃
Relative Humidity: 53 %
ATM Pressure: 101.0 kPa
The testing was performed by Bin Deng on 2021-12-14
Note: Pre-scan in the X,Y and Z axes of orientation, the worst case Y-axis of orientation was recorded.
30MHz-1GHz:
Test mode 1:
Horizontal:
Version 59 2021-11-09 Page 16 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Vertical
Version 59 2021-11-09 Page 17 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Test mode 2:
Horizontal:
Version 59 2021-11-09 Page 18 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Vertical
Version 59 2021-11-09 Page 19 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Test mode 3:
Horizontal:
Signal from Generator
Version 59 2021-11-09 Page 20 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Vertical
Signal from Generator
Version 59 2021-11-09 Page 21 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Test mode 4:
Horizontal:
Signal from Generator
Version 59 2021-11-09 Page 22 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Vertical
Signal from Generator
Version 59 2021-11-09 Page 23 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Test mode 5:
Horizontal:
Signal from Generator
Version 59 2021-11-09 Page 24 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Vertical
Signal from Generator
Version 59 2021-11-09 Page 25 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Test mode 6:
Horizontal:
Signal from Generator
Version 59 2021-11-09 Page 26 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Vertical
Signal from Generator
Version 59 2021-11-09 Page 27 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Test mode 7:
Horizontal:
Signal from Generator
Version 59 2021-11-09 Page 28 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Vertical
Signal from Generator
Version 59 2021-11-09 Page 29 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Test mode 8:
Horizontal:
Signal from Generator
Version 59 2021-11-09 Page 30 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Vertical
Signal from Generator
Version 59 2021-11-09 Page 31 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Test mode 9:
Horizontal:
Signal from Generator
Version 59 2021-11-09 Page 32 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Vertical
Signal from Generator
Version 59 2021-11-09 Page 33 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Test mode 10:
Horizontal:
Signal from Generator
Version 59 2021-11-09 Page 34 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Vertical
Signal from Generator
Version 59 2021-11-09 Page 35 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Test mode 11:
Horizontal:
Signal from Generator
Version 59 2021-11-09 Page 36 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Vertical
Signal from Generator
Version 59 2021-11-09 Page 37 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Above 1 GHz:
Test mode 1:
Horizontal:
Version 59 2021-11-09 Page 38 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Vertical
Version 59 2021-11-09 Page 39 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Test mode 2:
Horizontal:
Version 59 2021-11-09 Page 40 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Vertical
Version 59 2021-11-09 Page 41 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Test mode 3:
Horizontal:
Version 59 2021-11-09 Page 42 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Vertical
Version 59 2021-11-09 Page 43 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Test mode 4:
Horizontal:
Version 59 2021-11-09 Page 44 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Vertical
Version 59 2021-11-09 Page 45 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Test mode 5:
Horizontal:
Version 59 2021-11-09 Page 46 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Vertical
Version 59 2021-11-09 Page 47 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Test mode 6:
Horizontal:
Version 59 2021-11-09 Page 48 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Vertical
Version 59 2021-11-09 Page 49 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Test mode 7:
Horizontal:
Version 59 2021-11-09 Page 50 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Vertical
Version 59 2021-11-09 Page 51 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Test mode 8:
Horizontal:
Version 59 2021-11-09 Page 52 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Vertical
Version 59 2021-11-09 Page 53 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Test mode 9:
Horizontal:
Version 59 2021-11-09 Page 54 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Vertical
Version 59 2021-11-09 Page 55 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Test mode 10:
Horizontal:
Version 59 2021-11-09 Page 56 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Vertical
Version 59 2021-11-09 Page 57 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Test mode 11:
Horizontal:
Version 59 2021-11-09 Page 58 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Vertical
Version 59 2021-11-09 Page 59 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
FCC §15.111 - ANTENNA CONDUCTED POWER FOR RECEIVERS
Applicable Standard
FCC §15.111
Limit
The antenna conducted power of the receiver as defined in §15.111 shall not exceed the values given in the following
tables
Frequency Range Limit
9 kHz to 5 GHz 2.0 nW (-57 dBm )
EUT Setup
Test Procedure
1. The receiver antenna terminal connected to a spectrum analyzer.
2. The test data of the worst case condition (mode 2) was reported on the following Data page.
Test Data
Environmental Conditions
Temperature: 25 ℃
Relative Humidity: 64 %
ATM Pressure: 101.0 kPa
The testing was performed by Paul liu on 2021-12-20
Version 59 2021-11-09 Page 60 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Test mode: Scan receiver mode
Conducted Measurement (9 kHz to 30 MHz)
Conducted Measurement (150 kHz to 30MHz)
Version 59 2021-11-09 Page 61 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Conducted Measurement (30MHz to 1GHz)
Conducted Measurement (1GHz to 5GHz)
Version 59 2021-11-09 Page 62 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
FCC §15.121(b) - SCANNING RECEIVERS AND FREQUENCY
CONVERTERS USED WITH SCANNING RECEIVERS
Applicable Standard
FCC §15.121(b)
Limit
Except as provided in paragraph (c) of this section, scanning receivers shall reject any signals from the Cellular
Radiotelephone Service frequency bands that are 38 dB or lower based upon a 12 dB SINAD measurement, which is
considered the threshold where a signal can be clearly discerned from any interference that may be present.
EUT Setup
Test Procedure
1) Connected the EUT as shown in the above block diagram.
2) Apply a RF signal to the receiver input port at lowest, middle and highest channel frequencies of
receiver operation band.
3) Adjust the audio output level of the receiver to it’s rated value with the distortion less than 10%.
4) Adjust the RF Signal Generator Output Power to produce 12 dB SINAD without the audio output
power dropping by more than 3 dB.This output level of the RF SG at each channel frequency is the
sensitivity of the receiver.
5) Select the lowest or worse-case sensitivity level for all of the bands as the reference sensitivity.
6) Adjust the RF Signal Generator output to a level of +60 dB above the reference sensitivity obtained in
step 5) and its frequency to the frequency points in the cellular band.
7) Set the Receiver squelch to threshold, the signal required to open the squelch must be lower than the
reference sensitivity level.
8) Set the receiver in a scanning mode and allow it to scan through it’s complete receiving range.
9) If the receiver unsquelched or stopped on any frequency, receiving at this frequency, then adjust the
signal generator output level until 12 dB SINAD is produced, this level is the spurious value and the
difference between the reference sensitivity and the spurious value is the rejection ratio and must be at
least 38dB.
10) Repeat above procedure at the frequencies 824, 836.0, and 849 MHz for the mobile band, and
869, 881.5, and 894 MHz for the cellular base band.
Version 59 2021-11-09 Page 63 of 64 FCC-EMC
Shenzhen Accurate Technology Co., Ltd. Report No.: XMTN1211208-63393E-01
Test Data
Environmental Conditions
Temperature: 25 ℃
Relative Humidity: 53 %
ATM Pressure: 101.0 kPa
The testing was performed by Pual liu on 2021-12-20.
Test mode: Scanning
EUT’s Scanning
Test Frequencies of
Frequency Measurement Result Limit
Cellular Band
Range (dB) (dB)
(MHz)
(MHz)
824, 836.0, 849,
136-174 48 >38
869, 881.5, 894
824, 836.0, 849,
400-520 46 >38
869, 881.5, 894
*****END OF REPORT*****