Manual Protocol Reader O EN

This document provides information about protocol readers READER O-1-B and READER O-3-B, including their technical specifications, installation instructions, and connection details. The readers are used with access controllers and have either 125kHz or 13.56MHz reading frequencies. Proper installation and cabling is required to ensure optimal reading range and avoid interference.

Uploaded by

Sándor Vámos
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
30 views1 page

Manual Protocol Reader O EN

This document provides information about protocol readers READER O-1-B and READER O-3-B, including their technical specifications, installation instructions, and connection details. The readers are used with access controllers and have either 125kHz or 13.56MHz reading frequencies. Proper installation and cabling is required to ensure optimal reading range and avoid interference.

Uploaded by

Sándor Vámos
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

READER O-1-B and READER O-3-B – Protocol reader

Reading range:
The reader has a program algorithm that, at power start, sets parameters
based on the installation environment, so as to ensure an optimal reading
range. DO NOT install the reader directly on metal surfaces and/or cover it
with a metal cover; it may stop working/reading. If you plan to test the
controller and move it onto different surfaces, then you have to reset it
(power off/on) on each surface.
Reading distance depends on where the reader is installed. The presence of
metal or interferences can significantly reduce reading distance.
It is not recommended to install readers closer than 30cm from each other
in any direction. Otherwise, it may result in inaccurate readings or, indeed,
in the device not reading at all.
READER O-1-B and READER O-3-B – PROTOCOL
READER Installation of Reader O

Readers are used as external readers for access controllers Populus V9. Remove black plastic screw covers on the top and the bottom
Access controller needs to be connected to the network switch with protocol of the Reader. Install it to the wall with two supplied screws.
readers connected to its RS485 line. Communication between the controller Use diagonal holes - it enables a small correction of the
and the reader is RS485 and it is encrypted. position of the device (up, down, left, right). When the reader
The Reader can have 125kHz or 13.56MHz reading frequency. The device is installed, put the screw covers back on.
signals normal operation with flashing red and green LED.

TECHNICAL DATA
READER B
READER O-1-B reading frequency 125kHz Connection:
READER O-1-B reading distance Up to 13cm Access controller which is used with protocol readers must not be connected
READER O-1-B current consumption 40mA to common RS485 line. To ensure proper operation, the access controller
READER O-3-B reading frequency 13.56MHz must be connected to the network switch.
READER O-3-B reading distance Up to 7cm Protocol readers must be connected to:
READER O-3-B current consumption 55mA - connector for reader connection (RDR1 ... - Power supply 12V, GND)
- connector for communication (RDR - RS485 line XA, XB)
Dimensions (mm) 58x120x17 (WxHxD)
Protection IP65
Communication RS485 Usage:
In connection with the protocol readers the access controllers are used only
Operating voltage From 9V to 14V DC
with V9 communication protocol. When you are searching for the controller
Operating temperature From -20°C to 70°C
and readers in the Codeks Device Manager software, you must enable
Cabel Flat cable 20cm
checkbox "V9 communication". In the Codeks AC or Codeks TA program you
need to set for the communication line the function "Protocol - V9" under the
CONNECTION CABLE "Options" tab.
Wire-Color Description Specification
1 – red 9-14V DC Power supply Protocol readers have a default address 50 to 100. The address can be
2 – gray GND Ground changed in Codeks Device Manager software to the address from 1 to 8 to
3 – gray CA RS485 A line improve transparency in the program Codeks. The choice of address number
4 – gray CB RS485 B line depends on the placement of the reader in the system.
In the Codeks AC or Codeks TA software simply select the type (Protocol)
and address of the reader individually for each reader.
LED DIODES
Color Description
Flashing red/green Normal mode ORDERING CODES
Lit green El. strike is unlocked
Lit red Card has no rights READER [box]-[card]-[software]
Box: O
Card: 1 – reading frequency 125kHz (cards)
Voltage drops and cable signal interferences 3 – reading frequency 13.56MHz (cards)
When you connect the reader, use cable with a diameter of at least
Model: B – Black line
0.22mm2. If the cable length exceeds 25m, use one twisted pair of UTP
Software: CODEKS (from v. 9.0.1.53)
cables for the positive (+) pole and one for the negative (-) pole.
To achieve cable distances of over 200m, use one twisted pair (two wires) of CODEKS DEVICE MANAGER (from v. 9.6.)
UTP cable, for each data line. From each twisted pair, use one wire for the
Reader’s negative pole (connect them to the readers and controllers GND). Code Description
In this way you create a shield over the data wires, which remove’s READER O-1-B 125kHz Protocol reader in O box
interferences between them. READER O-3-B 13,56MHz Protocol reader in O box
Take into consideration that a 0.22mm2 cable has a resistance of
approximately 9 ohm per 100m. The power supply at the end of cable should
be a minimum of 9V. If you are using el. strike, it is highly recommended
that the voltage drop is calculated. At greater distances, a thicker cable of OTHER
0.5mm2 or more should be used wherever possible.
If the load is, for example, 0.5A (with el. strike) then, on the 0.22mm 2 cable Please read through our warranty and disclaimer statements.
voltage drop will be 4.5V at 100m. For the device with 60mA consumption,
the voltage drop is 0.5V. Connection scheme and additional support for the use of this product can be
found on:
For READER O-3-B to comply with EMC directives (CE), you have to http://www.jantar.si/forum/en
put ferrite core on the cable as close to the reader as possible,
making two turns! CONTACT:
Jantar d.o.o.
Environment: Kranjska cesta 24
Device has IP65 protection, but you must assure good cable joints, protected 4202 Naklo web: www.jantar.si
against moisture, otherwise corrosion may damage the device. Damage in SLOVENIA mail: [email protected]
such cases is not covered by the warranty.

12/2016
Black line www.jantar.si