ARCHITECTURAL DESIGN 3
AR2111 – SY 2023-2024
1A-D1-2MP1-101322
Student
Instructor
PD 1096 – Philippine National Building Code. Adopting National Bldg. Code of the
Philippines, Revising R.A. 6541
R.A. 6541 – An Act to Ordain and Institute a National Building Code of the Philippines.
- Does not confirm with the developmental goals and infastracture program of
government.
- Does not Adequately provide all technological requirements of building or
structure, in terms of up to date design and construction standard criteria.
- Purpose of PD 1096 is to provide and regulate bldg. structures to reach
the minimum standards requirements and to control the location, site design and
quality of materials, construction use occupancy and maintenance.
PD 1096 must apply to design, location, siting , construction, alteration, repair, conversion, use
occupancy, maintenance , moving, demolition, addition to public and private building and
structure except traditional indigenous houses.
- Building and structures constructed before the approval on this code shall not be affected.
Except it will apply when some portions will be altered, added, converted or repair.
TYPES OF CONSTRUCTIONS
Type 1 – Buildings shall be wood construction.
Type 2 – Buildings shall be wood construction with protective fire resistant materials and with
one hour fire resistively. Except for non- bearing partitions.
Type 3 - Building shall be masonry and wood construction. It shall have 1 hour fire resistive
through out. Exterior wall shall be fire resistive construction.
Type 4 - Building shall be steel iron concrete or masonry construction. Permanent walls and
partitions shall be fire in combustion. Except permanent non-bearing partition of 1 hour fire
resistive construction, may use fire retardant treated wood for framing.
Type 5 – Building shall be fire resistive, structural shall be steel. Iron , concrete and masonry
construction.
CEILING HEIGHTS
-Habitable room with artificial ventilation is 2.40 meters from floor to ceiling.
-Ground floor: 2.70 mts. 2nd floor: 2.40 mts. Floor to ceiling
-Succeeding floors not less than 2.10 mts. Above finish floor line.
-For natural ventilation: not less than 2.70 meters
-Mezzanine is not more than 1.80 meters.
SIZES AND DIMENSIONS OF ROOMS (sec. 806)
-Human habitation: 6.0 sqm. with least dim. of 2.0 meters 2.0x3.0
-Kitchen : 3.0 sqm with least dim. of 1.5 meters. 1.5x2.0
-T&B : 1.20 sqm with least dim. of .90 meters .90 x 1.30
-Every floor having an occupant load of 500 - 999 shall have 3 exits.
-Having occupant load 1000 or more must have 4 exits. PERMITS AND APPLICATION
(chapter 3)
Sec 302 Application of Permit – 5 Corresponding Plans and Specifications signed by license
architect and engineers.
Sec 309 Certificate of Occupancy – shall issue by building official within 30 days after the final
inspection and submittal of certificate of completion.
STAIRWAY WIDTH
- Occupant more than 50, minimum of 1.10 meters wide
- 50 or less minimum of .90 meters wide
- Private stairways less than 10 have .75 meters wide.
- Vertical distance between landing not morethan 3.60 meters.
- Minimum Thread = .20 meters Maximum riser = .25 meters
HANDRAILS
- 3.0 meters width of stairs – provide not less than 2 handrails.
- 1.10 meters or less – serving Group A and B have 1 handrails
- Intermediate railings is not less than 80 mm and not more than 90 mm.
- stairways not more than 4 risers don’t need railings.
- Handrail distance to wall – minimum of 38mm.
- Handrails – .80 meters to 1.20 meters high.
- Handrails diameters are 30mm – 50mm diameter
INTERIOR WET STAND PIPE – 38mm diameter in every storey
1.20 meters above the floor.
· 1 wet standpipe for more than 1000 persons for assembly building
· 15 meters high is known as a high rise building
· Fire hose – required 38mm diameter
· Down feed water distribution = 132 lit./min.
DEFINITION OF TERMS:
BLDG OFFICIAL – Charge of duties of issuing bldg permit. BLDG PERMIT – Written
authorization granted by bldg official to applicant to proceed with the construction.
AGENCY OF THE GOVERNMENT – Refers to any various units of governments.
APPALICANT/PERMITTEE – Any character applying for an issuance of permits and
certificate.
NATIONAL GOVERNMENT – Entire machinery of central government.
PERMIT PRINCIPAL – Ancillary permit pertaining to building structures.
TYPES OF OCCUPANCY
· Category l - Residential
· Category ll – Commercial and industrial
· Category lll – Social, educational, institutional
· Category lV – Agricultural
· Category V – Ancillary
FLOOR TO FLOOR HEIGHT – min of 3.0 meters for structures finish floor to finish floor.
LOWRISE – From 1 storey to 5 store’s in height from 3.0 meters – max of 15.00 meters high.
MEDIUM RISE – From 6 storey to 15 storey’s in height.( 18.0 meters
– 45.0 meters)
HIGH RISE – 16 storey above ( 48.0 meters above)
BUILDING HEIGHT;
· BASEMENT – Below natural and finish grade.
· BASEMENT FOOTPRINT – Actual land area occupied by the basement, measured by its
outer wall.
· BUILDING HEIGHT LIMIT – Max. height to be allowed for the building.
· ESTABLISH GRADE ELEVATION – Highest adjoining natural grade.
· FLOOR TO FLOOR HEIGHT – Max. distance of 3.0 meters . A perpendicular distance
between 2 upper floor levels.
· GRADE – 1.50 meters horizontal distance between fin. Surface of the ground to exterior
wall/property line.
· HEIGHT OF THE STRUCTURE – Vert. clearance from fin. Grade line from the highest
point of couping.
· PODIUM – Full enclosed part of the building. First of typical floors of the building.
· RESULTANT HEIGHT – Vertical measurement of propose building.
· STOREY – Upper floor to floor finish building.
· TOWER – Fully enclosed component of the building, Not more than 5 times the height of
the podium.
· ALLOWABLE MAX. BUILDING FOOTPRINT – Max. pportion of lot that occupied by
building . measure at the outermost part wall of the building.
· FRONT YARD – Created by setbacks along RROW. Transition area between sidewalk and
other similar portion of RROW.
· FRONT LOT – Side opf the lot which the main pedestrian and vehicular access in the
property shall be situated.
· COURT – An occupied space between the faces of the building lines.
· INNER COURT – Court bounded on all sides
· OPEN COURT – Bounded on 3 sides by building lines.
· THROUGH COURT – Bounded on 2 opposite side by building lines.
· COURT YARD – A portion of a yard had limit on hardscaping not exceeding 50% of yard
area.
· VENT WELL – Permitted opening along vertical portion of firewall. Max. width of 3.0
mts. And min depth of 1.50 mts.
· ROAD RIGHT OF WAY (RROW) – Public open space for continuous flow of pedestrian
and vehicular traffic.
---------------------------------------------------------------------------------------
· EASEMENT – Public open space define under water code
· Min. easement for urban areas 3.0 meters
· Min. court width 2.o mts.
· Min. walkway is 1.20 mts.
---------------------------------------------------------------------------------------
· .60 meters footing extension from property line (national road and public highways
· .30 meters for public sidewalk
SIGNS:
· ADVERTISING SIGN – Off-premises sign
· BILLBOARD – Panel for posting bills or posters
· DISPLAY SIGN – On premises sign
· GROUND SIGN – Resting on the ground
- Maximun height of 6.0 meters on sign dimension
· PROJECTING SIGN – Suspended form the building. Perpendicular to the angle of the
surface of the wall.
- Non Arcaded – min. of 3.0 mts high - max 1.50 mts from bldg. line
- Arcaded – min of 5.0 meters high - max 1.0 mts from wall line
· ROOF SIGN – Parallel to wall surface
· TEMPORARY SIGN – On light and combustible material.
PARKING REQUIREMENTS:
Low cost housing – 1:10 minimum
Condominiums – less than 50 ( 1: 8 ) 50-100 (1:4) morethan 100 1:1
Hotels – 1:10 (10 room 1 parking slot)
RAMPS:
Class A: 8-10% slope Class B: 10-17% slope
Max. Curb: .20 mts. Ideal Ramp : 1:20 SIZES OF LOT:
Economic : 72 Sqm. Duplex Single Detached : 48 Sqm.
RAW HOUSING:
Economic : 36 Sqm. Socialize 32 Sqm. Maximum Cluster : 20 Frontage: 3.0 mts
Maximum Block: 100 mts.
WINDOW REQUIREMENTS:
· 1:10 of room floor area.
· 1:20 or 5% of toilet floor area
BATAS PAMBANSA BLG.344 ( BP344 ) – The law to enhance mobility of disable person, by
requiring certain building, institution, establishment and public utitlities to install facilities and
other device. ANTHROPOMETRICS:
· Length of wheel chair : 1.0 – 1.30 mts.
· Width of wheel chair: .60 - .75 meters
· Turning Radius: 1.50 meters
· Comfortable Reach : .70 – 1.20 meters from the floor.
· Room Corner Reach: .40 meters
· Clearance of leg under the table: .75 meters
SIGNAGES:
· Min Headroom for walkway: 2.0 meters
· Signs on Doors and Walls: Max of 1.60 meters Min. of 1.40 meters
· Signage Symbols and Letters: .10 meters
PARKING:
· Min. Width: 3.70 meters
· Min Width for front and end passage: 1.20 meters
RAMP:
· Provide landing for every 6.0 meters
· Min clear width of 1.20 meters
· Maximum gradient is 1:12
· Min curb for both side of ramp is .10 meters
· Handrails for 2 sides of the ramp .90 meters and .70 meters highramp greater than .20
meters leads toward the vehicular traffic railings, min. of 1.80 meters from the foot of
ramp.
DOORS:
· Min Width: .80 meters
· Door Opening Pressure: more than 4.0 kg
· Clear Space for Extending Beyond the Door: 1.50 meters – 1.50 meters (minimum)
· Door Knobs height from floor: .82 meters - 1.06 meters
· Kick Plates: .30 meters - .40 meters
-------------------------------------------------------------
Threshold / Change in Floor Level: 0.205 meters
SWITCH:
· 1.20 meters - 1.30 meters above the floor
· .20 meters from latch side of the door
CORRIDOR:
· Min clear width of 1.20 meters
· Turn About spaces to pass another wheelchair min. of 1.50 x 1.50 meters space at
maximum of 12.0 meters
· Turn about should be provided within 3.50 meters of every dead end
ELEVATORS:
· Max of 30.0 meters from entrance
· Elevator min dimension: 1.10 x 1.40 meters
· Control panel should be between .90 meters to 1.20 meters high.
STAIRS:
· Tactive Strip for change level is .30 meters
WATER FOUNTAINS:
· 1 for every 2000 sqm of floor, atlease 1 for every floor
· Wall mounted maximum height of .85 meters.
PUBLIC TELEPHONES:
· 1.50 meters from un-obstruction space
· 1.10 meters hight of the units.
PD 1185 THE FIRE CODE OF THE PHILIPPINES AND REGULATION ( August 26, 1977)
Fire Protection Equipment:
· Utilities
· Heating , Ventilation , Air-conditioning
· Smoke control
· Elevators and Escalators
· Rubbish Chutes, Incinerators and Laundry Chutes
· Fire Detection, Alarm, Communication Systems
· Automatic Sprinklers, and other Extinguishing Equipment
DEFINITION OF TERMS:
· Automatic Fire Suppression System – Integrated system of underground and overhead
piping connected to a source of extinguishing agent.
· Fire Alerting System – Activated by the presence of fire, where the signal is transmitted
to designated locations.
· Fire Protective Assembly – Incorporated to structure to prevent the spread of fire.
· Dry Standpipe – Pipe that does not filled with water
· Fire Wall – To prevent the spread of fire. Have a fire resistance of 4 hours.
· Means of Egress – Continuous and unobstructed rout of exit to any point of the building
to a public way.
· Fire Retardant – Any compound mixture, which applied to materials to improve its fire
resistant
· Panic Hardware – Mechanical device consisting of linkages and a horizontal bar across a
door.
· Organic Coating – Liquid mixture of binders and combustible solvents which when
pread to the surface it becomes durable protective and decorative finish.
· Fire Resistance Rating – Time duration of material can stand the effect of fire.
· Flame Spread Rating – Time in which the flame will spread in the surface of material.
· Smoke Developed Rating – Volume of smoke developed within a certain period of time.
SEPARATION OF EXIT
· 1 hour fire resistance rating for 3 stories or less
· 2 hour fire resistance rating for 4 and more stories
TRAVEL DISTANCE
· Without fire suppression system – 45.0 meters
· With Fire Suppression system – 60.0 meters
· Min width of the door - .71 meters Maximum of 1.22 meters
· Area separation - 0.205 meters
LOADS
· Stair, flat form, loading, balcony stair hallway have carrying load of 88 kg per sq.meter
or concentrated load of 136 kg.
SLIDE ESCAPES
· 1 exit unit per slide. Traveling time of 60 person per minute
EMERGENCY LIGHTING
· Light should last 1.5 hours in building more than 36.5 meters high
EXIT SIGNS
· Exit signs shall have max height of 15 cm and principal strokes of letters at lease 19 mm
wide.
GENERAL PROVISION FEATURES OF FIRE PROTECTION
· Sprinkler Vent Method – Combination of Automatic smoke detection system, automatic
exhaust system and automatic water curtain
· Spray Nozzle Methods – Combination of automatic smoke detection system and high
velocity water spray nozzle.
· Rolling Shutter Method – Automatic self rolling shutter. Completely enclose the top of
escalator
· Partial Enclosure Method – Kiosk designed to provide an effective barrier to the spread
of smoke floor to floor
· Fire Stopping Concealed Spaces – Concealed space in which expose materials have fire
spread ratings greater than Class A.
CONTENT
Fire Safety in Places of Assembly
· Main exit must occupied 50% of occupant load
· Travel distance with Automatic Fire Suppression is 46 meters
· Without protection 61 meters from the exit.
Multiple Seating
· Rows of seat between aisles max of 14 seats
· 7 rows to open 1 aisles only
· back to back facing max of 0.83
· seats without dividing arms: .60 per person
· aisles width: 0.91 – 1.0 for more than 60 seats
0.76 for less than 60 seats
Occupant Loads
· Without fixed seats such as auditorium, church: 0.65 sqm./ person
· Less concentrated such as conference room, dining room, exhibition room, gymnasium:
1.4 sqm/person
· Standing Room or Waiting Space: 0.28 sq.m/person
GENERAL PROVISIONS:
Educational Occupancies
· Room with 50 person or over 93 sqm shall have 2 exits
Occupant Loads
· Classroom 1.80 sq.m/person
· Shop, Lab, vocational room 1.40 sq.m/person
· Dry nurses w/ sleeping facility 3.25 sq/m/person
Institutional Occupancies
· Healthcare facilities: hospital and nursing homes
· Residential Custodial area: Nurseries, Home for the Age, Mentally Retarded Care
· Residential – Restrained Care: Penal Institutions, Reformaries, Jails
Residential Occupancies
· Hotels: More than 15 accommodations for hire
· Apartment : 3 or more accommodating units with T&B
· Dormitories: Group sleeping accommodations
· Lodging or Rooming Houses: Separated rented living rooms for 15 or less, transient or
permanent basis
Miscellaneous Occupancies
· Ordinary Hazard
· High Hazard
· Low Hazard
Ramps
· 1/8 or 12.5% slope
· Handrails required for 1/10 slopes
DEFINITION OF TERMS
· Combination Standpipe – with constant water supply use for fire service
- minimum of 15 cm diameter
- 4 way connection for combination of 2 system
- (2) 4way connection for combination of 3 or more system
- 64 mm diameter outlet in .61 mts to 1.22 mts above floor each storey
· Dry Standpipe – without a constant water supply with a fire service inlet and outlet
connections.
- One outlet connection every floor level
- Will stand 21 kg/sq.cm of water pressure
- 20% slope of horizontal runs
- 102 mm diameter for 23 meters highest outlet connection
- 153 mm diameter for higher than 23 meters outlet connection
- 102 mm diameter dry standpipe for 4way connections
- .46 meters – 1.22 meters high connection at front street above grade
- 6.4 cm outlet and .61 mts – 1.22 mts above flr level each storey
· Wet Standpipe – with constant water supply installed primary for emergency
- Assembly bldg. more than 1000 occupants.
- Required for Hazardous storage, business and mercantile occupancies more than 1,860
sq.m
- 6 meters nozzle attached to 22 meters of hose
- 64 mm diameter if height of the riser is 15 meters above
- 51 mm diameter if less than 15 meters
- 38 mm diameter valve per storey, .91 mts to 1.92 mts above flr
- 132 lit/min with 1/8 kg/sq.cm pressure for each outlet for 30 mins.
- 38 mm diameter min. per standpipe
· Fire Dept. House Connection – a hose connection at the street level
THE URBAN DEVELOPMENT AND HOUSING ACT REPUBLIC ACT 7279 March 24, 1992
Objectives:
· Decent and affordable housing with basic services and livelihood opportunities,
· Disperse urban net and more balance urban-rural inter dependence
· Equitable land tenure system
· Improve LGU capability
Strategies:
· Balance housing
· Private sector participation
· Country side development
· Government intervention in land acquisition
Other Entities
· LGU – Comprehensive Land Use Plan
· NEDA – Data for forward planning
· Private Sectors and NGO – Investments
Products:
· Rationally site settlements, livelihood components, basic services, affordable package,
need specific units, use of indigenous materials and alternative technologies.
Basic Needs:
· Water, Movement and circulation, Storm drainage, Solid and liquid water disposal, Parks
and playgrounds, Power
Site Criteria:
· Conformity with zoning ordinances and land use plan
· Physical suitability
· Accessibility
Land Allocation:
· No fixed ratio between saleable and non salable portions
Parks and Playgrounds:
· Centrally located
· Mandatory of 1 Has. And above
· Non- alienable
Street:
· Aspalt - 2” min. thick for pavement
· Concrete – 6” min. thick for concrete
· Major Road: 1.0 mts sidewalk, 1.0 mts. Plant strip, 8.0 mts carriageway. Total of 12.0
mts ROW
· Minor Road: 1.0 mts. Sidewalk, 1.0 mts plant strip, 6.0 mts carriageway. Total of
10.0 mts ROW
Block Length:
· Max. of 400 mts.
· Provide 3.0 mts. Pathwalk or alley blocks exceeding 250 meters
Minimum Frontage:
Corner lot: 8.0 meters
Regular lot: 8.0 meters
Irregular lot: 4.0 meters
Interior lot : 3.0 meters
DUPLEX/SINGLE ATTACHED
Minimum lot areas
Economic: 54 sq. m 9.0 x 6.0
Socialize: 48 sq.m 8.0 x 6.0 Minimum frontage
Economic: 6.0 meters
Socialize: 6.0 meters
ROW HOUSE
Min lot areas
Economic: 36 sq.m 6.0 x 6.0
Socialized: 32 sq.m 8.0 x 4.0 Minimum frontage
Economic: 3.5 meters
Socialized: 3.5 meters
WATER SUPPLY
· Independent water supply system at 150 lit/capita/day
· Ground reservoir 25 meters from source of contaminants
POWER SUPPLY
· Provide 1 street light per pole when pole spaced at 50 meters
· Provide 1 street light every other poles when pole spaced less than 50 meters.
ELEVATOR
· Min of 5 storey to provide elevator
STAIRS
· Internal: .15 mts Middle: .30 mts. Outside: .30 meters
· Max. travel distance to stairways: 24.0 meters
· Min. head clearance: 2.0 meters
· Max. height of landing to landing: 3.60 meters
· Min. stairway width : .60 meters
· Handrail height: .80 – 1.20 meters
CORRIDORS
· Min clear 1.20 meters
FIREWALLS
· Min of .30 mts from apex of roof, and from wall for duplex/single detached.
Selling Price
· Open Market: P 2,000.00 Above
· Medium Cost: P 500,000 – 2,000,000
LOTS
· Single-Detached Units Min. lot areas
Open Market: 120 sq.m Medium Cost: 100 sq.m Minimum frontage
Corner lot: 12 meters
Regular lot: 10 meters
Irregular lot: 6.0 meters
Interior lot: 3.0 meters