Sika Anchorfix - 3001

This document provides product data and application instructions for Sika AnchorFix-3001, an epoxy resin based two-part anchoring adhesive. It has high load capacity and fire resistance and is suitable for anchoring rebar, bolts, and other fasteners in cracked and uncracked concrete.

Uploaded by

rana.das
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
33 views5 pages

Sika Anchorfix - 3001

This document provides product data and application instructions for Sika AnchorFix-3001, an epoxy resin based two-part anchoring adhesive. It has high load capacity and fire resistance and is suitable for anchoring rebar, bolts, and other fasteners in cracked and uncracked concrete.

Uploaded by

rana.das
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

PRODUCT DATA SHEET

Sika AnchorFix®-3001
Epoxy high performance chemical anchoring adhesive

DESCRIPTION ▪ Fire resistant


▪ Styrene-free
Sika AnchorFix®-3001 is an epoxy resin based, 2-part, ▪ Good adhesion to the substrate
thixotropic, 1:1 mixing ratio, high performance an- ▪ Shrinkage-free hardening
choring adhesive. It is specifically designed for anchor- ▪ Standard sealant guns can be used (250 ml cartridge)
ing threaded rods and reinforcement bars in both ▪ Low wastage
cracked and un-cracked dry or damp concrete.
ENVIRONMENTAL INFORMATION
USES
▪ Conformity with LEED v4 MRc 2 (Option 1): Building
Sika AnchorFix®-3001 may only be used by experi- Product Disclosure and Optimization – Environment-
enced professionals. al Product Declarations
▪ Conformity with LEED v4 MRc 4 (Option 2): Building
Anchoring adhesive for fixing of non-expanding an- Product Disclosure and Optimization - Material In-
chors in the following: gredients
Structural work
▪ Rebar / steel reinforcement anchoring in new and re- APPROVALS / STANDARDS
furbishment works
▪ Threaded rods ▪ CE Marking and Declaration of Performance to ETA
▪ Bolts and special fastening / fixing systems 14/0157, based on ETAG 001 Part 1 and Part 5 - Bon-
Metalwork, carpentry ded injection type anchor for use in cracked and un-
▪ Handrails, balustrades and supports cracked concrete
▪ Railings ▪ CE Marking and Declaration of Performance to ETA
▪ Window and door frames 14/0368, based on ETAG 001 Part 1 and Part 5 - Post
Substrates installed rebar connections
▪ Adhesive Anchors for Cracked and Un-cracked Con-
▪ Concrete (cracked and un-cracked)
crete IBC/IRC, Sika AnchorFix®-3001, ICC-ES, Evalu-
▪ Hollow and solid masonry ation report No. ESR-3608
▪ Wood ▪ Drinking Water System Components NSF/ANSI 61,
▪ Natural and reconstituted stone Sika AnchorFix®-3001, IAPMO R&T, Certificate No. K-
▪ Solid rock 8319
▪ Fire Testing ISO 834-1, Sika AnchorFix®-3001, CSTB,
CHARACTERISTICS / ADVANTAGES Test report No. 26054326/B

▪ Long open time


▪ Can be used in damp concrete
▪ High load capacity
▪ ETA to ETAG 001 for anchoring in cracked concrete
▪ ETA to ETAG 001 for rebar connections
▪ ESR to AC308 by ICC-ES, anchoring in cracked con-
crete for static, wind and earthquake loading
▪ Seismic tested (C1)
▪ Suitable for contact with drinking water

Product Data Sheet


Sika AnchorFix®-3001
June 2023, Version 04.02
020205010030000004

1/5
PRODUCT INFORMATION
Chemical Base Epoxy
Packaging 250 ml standard cartridge 12 cartridges per box
pallet: 75 boxes

Shelf Life 24 months from date of production


Storage Conditions The product must be stored in original, unopened and undamaged sealed
packaging in dry conditions at temperatures between +10 °C and +25 °C.
Always refer to packaging.
Colour Part A off-white
Part B dark grey / black
A+B mixed grey

Density A+B mixed ~1.49 kg/l

SYSTEM INFORMATION
System Structure Ancillary products:
▪ Sika AnchorFix® Static Mixers -Nozzles

TECHNICAL INFORMATION
Compressive Strength ~85 N/mm2 (7 days, +20 °C) (ASTM D 695)

Modulus of Elasticity in Compression ~5 000 N/mm2 (7 days, +20 °C) (ASTM D 695)

Flexural Strength ~45 N/mm2 (7 days, +20 °C) (ASTM D 790)

Tensile Strength ~23 N/mm2 (7 days, +20 °C) (ASTM D 638)

Modulus of Elasticity in Tension ~5 500 N/mm2 (7 days, +20 °C) (ASTM D 638)

Service Temperature Long term -40 °C min. / +40 °C max. (ETAG 001, Part 5)
Short term (1–2 hours) +80 °C

APPLICATION INFORMATION
Mixing Ratio Part A : Part B = 1 : 1 by volume
Layer Thickness ~7 mm max
Sag Flow Non-sag, including overhead
Product Temperature 10 °C min. / +30 °C max.
Ambient Air Temperature +5 °C min. / +40 °C max.
Dew Point Beware of condensation.
Substrate temperature during application must be at least +3 °C above
dew point.
Substrate Temperature +5 °C min. / +40 °C max.

Product Data Sheet


Sika AnchorFix®-3001
June 2023, Version 04.02
020205010030000004

2/5
Curing Time Temperature Open time - T gel Curing time - T cur
+40 °C 3 minutes 3 hours
+35 °C to +40 °C 4 minutes 4 hours
+30 °C to +35 °C 6 minutes 5 hours
+25 °C to +30 °C 8 minutes 6 hours
+20 °C to +25 °C 11 minutes 7 hours
+15 °C to +20 °C 15 minutes 8 hours
+10 °C to +15°C 20 minutes 12 hours
+5 °C to +10 °C —* 24 hours
* Minimum cartridge temperature: +10 °C

BASIS OF PRODUCT DATA MIXING


Preparing cartridge: 250 ml
All technical data stated in this Product Data Sheet are
1. Unscrew and remove
based on laboratory tests. Actual measured data may
the cap
vary due to circumstances beyond our control.

FURTHER DOCUMENTS
▪ For specific information on design refer to: Technical
Documentation Sika AnchorFix®-3001 870 43 10
▪ Sika Method Statement: Sika AnchorFix®
▪ Sika AnchorFix®: Approvals
2. Pull out the plug
LIMITATIONS
▪ Natural / reconstituted stone and solid rock proper-
ties vary particular with regard to strength, composi-
tion and porosity. For each application, the suitability
of Sika AnchorFix®-3001 must be tested for bond
strength, surface staining and discoloration by first
applying the product to a sample area before full
project application.

ECOLOGY HEALTH AND SAFETY 3. Screw on the static


mixer
For information and advice on the safe handling, stor-
age and disposal of chemical products, users shall
refer to the most recent Safety Data Sheet (SDS) con-
taining physical, ecological, toxicological and other
safety-related data.

APPLICATION INSTRUCTIONS
SUBSTRATE QUALITY 4. Place the cartridge into
the application gun ready
Mortar and concrete must be at the required design for use
strength.
Substrate tensile / compressive strengths (concrete,
masonry, natural stone) must be confirmed by testing.
The anchor hole must always be clean, free from oil
and grease etc.
Loose particles must be removed from the holes.
Threaded rods and rebar's must be cleaned thor-
oughly and free from dirt, oil, grease, corrosion When the work is interrupted the static mixer nozzle
products or any other substances and particles which can remain on the cartridge after the gun pressure has
could affect adhesion. been released. If the resin has hardened in the nozzle
when work is resumed, a new nozzle must be at-
tached.

Product Data Sheet


Sika AnchorFix®-3001
June 2023, Version 04.02
020205010030000004

3/5
APPLICATION METHOD / TOOLS Anchors in solid masonry/concrete
1. Drill hole with an elec-
Reference must be made to further documentation tric drill to the diameter
where applicable, such as relevant method statement, and depth required. Drill
application manual and installation or working instruc- hole diameter must be in
tions. accordance with anchor
size
2. The drill hole must be
cleaned with oil free com-
pressed air using an air
lance, pressure: 6 Bar (90
psi). Start from the bot-
tom of the hole and clean
minimum 2x until return
air stream is free of dust
3. The drill hole must be
thoroughly cleaned with
the special steel brush (at
least 2x). The diameter of
the brush must be larger
than the diameter of the
drill hole
4. The drill hole must be
cleaned again as stage 2

5. The drill hole must be


thoroughly cleaned again
as stage 3

6. The drill hole must be


cleaned again as stage 2
&4

7. Pump gun at least 2x


until both parts are ex-
truded as a one consist-
ent colour. Do not use
this material. Release the
gun pressure and clean
the static mixer opening
with a cloth

Product Data Sheet


Sika AnchorFix®-3001
June 2023, Version 04.02
020205010030000004

4/5
8. Inject the adhesive into LEGAL NOTES
the drill hole, starting from
the bottom and slowly pull The information, and, in particular, the recommenda-
out the static mixer while tions relating to the application and end-use of Sika
extruding the resin into products, are given in good faith based on Sika’s cur-
the hole. Avoid entrapping rent knowledge and experience of the products when
air. For deep holes use ex- properly stored, handled and applied under normal
tension tubing conditions in accordance with Sika’s recommenda-
9. Insert the anchor with tions. In practice, the differences in materials, sub-
a rotary motion into the strates and actual site conditions are such that no war-
filled drill hole within the ranty in respect of merchantability or of fitness for a
adhesive open time. particular purpose, nor any liability arising out of any
Some of the adhesive legal relationship whatsoever, can be inferred either
must flow out of the hole from this information, or from any written recom-
mendations, or from any other advice offered. The
10. During the resin user of the product must test the product’s suitability
hardening time the an- for the intended application and purpose. Sika re-
chor must not be moved serves the right to change the properties of its
or loaded products. The proprietary rights of third parties must
be observed. All orders are accepted subject to our
current terms of sale and delivery. Users must always
Important Note: Anchors in hollow blocks: Use Sika refer to the most recent issue of the local Product
AnchorFix®-1. Data Sheet for the product concerned, copies of which
will be supplied on request. It may be necessary to ad-
CLEANING OF TOOLS apt the above disclaimer to specific local laws and reg-
ulations. Any changes to this disclaimer may only be
Clean all tools and application equipment with Sika® implemented with permission of Sika® Corporate Legal
Thinner C immediately after use. Hardened material in Baar.
can only be removed mechanically.

LOCAL RESTRICTIONS
Please note that as a result of specific local regulations
the performance of this product may vary from coun-
try to country. Please consult the local Product Data
Sheet for the exact description of the application
fields.

Sika (NZ) Limited


85-91 Patiki Road
Avondale, Auckland 1026
New Zealand
0800 745 269
www.sika.co.nz

SikaAnchorFix-3001-en-NZ-(06-2023)-4-2.pdf