LOCO No DATE LP remark Remarks

At GDR station F0703P1 AUX-2 contactor


Loco arrived on 06/06/2024 till
4/18/2024 fault and AUX-2 isolated VCU rest working
date no attention paied by firm
normal

39273 Train stopped due to F0803P1 AUX-3


(12.04.2024) isolated and panto lowered vcu rest
Loco arrived on 06/06/2024 AUX-
became normal, again train stopped due to
31.05.2024 1 rectifier module card changed ,
F0803P1 AUX-3 isolated and panto lowered
no attention paid on AUX-3
vcu rest became normal, after some train
stopped due to F0603P1 AUX-1 isolated

LP experienced AUX-2 & AUX-3 internal Loco arrived on 30/05/2024 no


02.05.2024
temperature warning. attention paid by firm
At times CP's continuously working (MR
Loco arrived on 30/05/2024 no
39245 07.05.2024 overshooting above 11kg/cm2 and comes
attention paid by firm
(29.04.2024) to normal after BLCP off and on)

LP experienced F0703P1 AUX-2 contactor


Loco arrived on 30/05/2024 no
07.05.2024 fault and AUX-2 isolated VCU rest working
attention paid by firm
normal

LP experienced VCB open with out any


Loco arrived on 19/05/2024 no
12.05.2024 message LP closed VCB second time VCB
attention paid by firm
tripped and Bogie-1 isolated.

message code 0057,VCB off without any


Loco arrived on 19/05/2024 no
39275 12.05.2024 message two times and further VCB closed
attention paid by firm
(05.05.2024) normal.

LP experienced EF battery ckt msg, VCB Due to earth fault in HLC control
18.05.2024 tripped, panto lowered and message Ckt,( in power car ) caused MCE
displayed 'no communication to CCU ' off

after opening VCB at neutral section display Due to earth fault in HLC control
39299
20.05.2024 got blank , panto lowered and BP dropped Ckt,( in power car ) caused MCE
(16.05.2024)
CE off and on not succeed hence loco failed. off