Specifica�ons Range
40Hz~100Hz:±(2.0%+5)
Current (ACA) 999.9A
100Hz~1000Hz:±(2.5%+5)
Current (DCA) 999.9A ±(2.0%+5)
Voltage (ACV) 999.9V/1500V 40Hz~1000Hz: ±(1.0%+5)
Voltage (DCV) 999.9V/2500V ±(1.0%+5)
Voltage (DC mV) 999.9mV ±(1.0%+5)
ACV (with LPF) 999.9V ±(2.0%+9)
ACA (with LPF) 999.9A ±(2.5%+9)
ACA (with LPF): flex clamp sensor 30.00A/300.0A/3000A ±(4.0%+9) (center area)
ACA: with flex clamp sensor 30.00A/300.0A/3000A ±(3.0%+5) (center area)
Power (DC) 999.9 kVA/2500 kVA ±(2.0%+20)
Frequency (A&V) 5.0 Hz to 999.9Hz ±(0.5%+5)
Resistance (Ω) 999.9Ω/9.999KΩ/99.99kΩ ±(1.0%+5)
Capacitance (F) 100.0μF/1000μF ±(1.0%+5)
Temperature -40°C~400°C/-40°F~752°F ±(1.0%+30); ±(1.0%+60)
Features
True RMS √
Display count 9999
Display LCD: Dual display (V+A)
Jaw (Max conductor dia.) 35mm
Diode √
Solar panel polarity indica�on when <-10 DCV, Audible & Visual alarm
Nega�ve indica�on (DC) Audible + Visual alarm
High voltage alarm √
UT219PV
Over range indica�on √
AUTO HOLD √
Inrush current √
PEAK √
DC
UNI-TREND AC IP65
TECHNOLOGY meters.uni-trend.com 35mm Safety & High-voltage Audible & Bluetooth IP65
Ultra-thin Jaw reliable measurement Visual alarm APP protec�on
Ultra-thin Clamp
External clamp sensor
35mm ultra-thin clamp, designed for narrow gaps in
the combiner or inverter and other �ght spaces The UT-CS09D flex clamp sensor is
environment. supported, which means the
AC current measurement range can
expand to 3000A, and the flexible
coils can handle measurements in
35mm narrow spaces.
Polarity indication
If the voltage is below -10V DC,
the system will ac�vate a series
of indicators: The red LED will
flash for a period of 10 seconds,
accompanied by buzzing.
High voltage measurement IP65 protection Addi�onally, the LCD screen will
display the "POLARITY" symbol,
aler�ng the user to the reversed
probes.
Bluetooth APP
By u�lizing the Bluetooth app, you can conveniently record the tes�ng results and measurement
Choosing a clamp meter with IP65
details. Moreover, the tes�ng reports and data can be effortlessly transported and shared with
func�on offers you reliable
your colleagues or team members.
High voltage measurement (up to AC 1500V, measurements in dusty and wet
DC 2500V) can fulfill the voltage measurement environments, with increased
requirements of exis�ng photovoltaic systems, durability and protec�on against
as well as large motors like high-power motors water damage.
found in mines and oil fields.