NOTES:-

A B C D E F G H J K L M N P Q R S 1. THIS DRAWING IS THE COPYRIGHT OF YA YAGHMOUR ARCHITECTS,


MUST NOT BE RETAINED, COPIED OR
USED WITHOUT THE ABOVE CONSULTANT'S AUTHORITY.

1 1 2. DO NOT SCALE FROM THE DRAWINGS.


3. ALL DIMENSIONS ARE IN METER & LEVELS IN METER. UNLESS

2 2 NOTED OTHERWISE. ALL DIMENSIONS TO BE VERIFIED ON SITE AND


APPROVED BY THE CONSULTANT ENGINEER.

4. THIS DRAWING SHOULD BE READ IN CONJUCTION WITH THE OTHER


RELEVANT ARCHITECTURAL, STRUCTURAL, MECHANICAL,
AND ELECTRICAL DRAWINGS AND ALL RELEVANT SECTIONS OF THE
SPECIFICATIONS.

3 3
4. ALL SERVICES CUT-OUTS, EQUIPMENTS & EQUIPMENTS PLINTH
ARE SHOWN INDICATIVE ONLY: CONTRACTOR TO COORDINATE
THESE WITH THE SERVICES & STRUCTURAL DRAWINGS.
ENTRY AREA FOR

4 4
SUBSTATION
52.92 m²
C-8
KEY PLAN:

5 STAIR-6 STAIR-4
5
12.87 m² 12.87 m² N
6 SUBSTATION
C-7 C-7
6 ROAD 21.00m

55.76 m²
C-7

7 +2500
7
PLOT 6181261
8 MAIN LOBBY
167.29 m² 8
+2650 C-1
+2650
+2650

Sim
LV ROOM
+2500

WATCHMAN KITCHEN WATCHMAN T&B


1
32.20 m²
6.25 m² 3.50 m² A-12-077
C-7 CCTV TELE. RM ELEC. RM ELEC. RM TELE. RM
C-3

9 9
10.96 m² 9.14 m² 9.43 m² 9.43 m² 9.14 m² C-3
STAIR-5 C-7 C-7 C-7 C-7 C-7 STAIR-3
12.87 m² 12.87 m²
C-7 +2500 +2500 C-7

10 GENERATOR ROOM
10
23.80 m² POD TOILET
C-7 5.49 m² WATCHMAN ROOM ROAD 21.00m
GARBAGE ROOM-3 15.53 m²
C-3
21.60 m² +2500 C-2

11 11
C-9

GARBAGE ROOM-2
22.66 m²

12 12
C-9

13 13

14 14

15

16
CEILING FINISHES
DETAILED DESIGN APPROVAL- DDA 00 15-12-23 R.Y.
MOISTURE RESISTANT WASHABLE ACRYLIC PAINTED GYPSUM
C-1
BOARD (COLOR TO CLIENT APPROVAL)

C-2 WASHABLE ACRYLIC PAINT TO SPRAY PLASTER

17
C-3 60X60 INSULATED GYPSUM TILES ELEC. RM TELE. RM
9.30 m² 9.48 m²
C-7 C-7 Purpose Of Issue Rev Date Authorized
C-4 STONE TILE CLADDING AS PER SPECIFICATION (color to client approval)
Client:

C-5 ALUMINUM STRIP PANEL AS PER SPECIFICATION (color to client approval) GARBAGE ROOM-1
21.12 m²
18
C-9

C-6 EXTERNAL PAINT


STAIR-2
SHAMAL ESTATES L.L.C.
CCTV
12.87 m²
C-7 19
EMULSION ACRYLIC PAINT TO SPRAY PLASTER
C-7 6.82 m²
(COLOR FOR APPROVAL)
20
C-7

C-8 ANTI-CARBONATE ACRYLIC PAINT (COLOR FOR APPROVAL) Project Title

C-9 ANTI-FUNGAL ACRYLIC PAINT (SKIM COATING)


21 PROPOSED RESIDENTIAL BUILDING
(G+2P+6)
C-10 GRP LINING NADD AL SHIBA FIRST, DUBAI
PLOT NO.6181261
LOBBY
49.99 m²
C-1
Main Consultant
STAIR-1
12.87 m²
22
23
C-7

architects DUBAI - UAE


Tel : +971 4 220 8666
planners Fax : +971 4 220 8066
+2650
engineers P.O. Box 99879

24
E-mail : [email protected]
www.yaghmourarchitects.com

+2500

25 Main Contractor

26

27
Drawing Title:

GROUND FLOOR REFLECTED CEILING


PLAN

28 Original Scale Drawn


KL / LD
Checked
MS
Approved
RY
Plot Size

GROUND FLOOR
As
indicated A1
1 Scale 1 : 175 29 NOTE: Project Number:
Date: NOV/2023 Date: NOV/2023 Date: NOV/2023

Sheet # Rev
ALL THE SPECIFICATIONS ARE COMPLIED
WITH THE AUTHORITY'S STANDARDS. 477-23 A-12-071 0