Swing Guard T SPECIFICATION MANUAL
Swing Guard T SPECIFICATION MANUAL
MANUFACTURER'S
MANUFACTURER'S STATEMENT
5924421 FEB 2016
32(1 1/4")
Disregard of the caution symbol can cause improper operation which may cause injury of a
CAUTION person or damage the object.
275(10 13/16")
NOTE Special attention is required to the section of this symbol.
56.5(2 1/4")
NOTE 1. This sensor is a non-contact switch intended for door mounting and to use on automatic swing doors.
Do not use for any other application.
2. When setting the sensor's detection area, make sure that there is no traffic around the installation site.
3. Before turning the power ON, check the wiring to prevent damage or malfunction of equipment connected
to the sensor.
4. Only use the sensor as specified in the operation manual provided.
5. Be sure to install and adjust the sensor in accordance with the local laws and standards of the country in 248(9 3/4")
which the sensor is installed. 1 : Connector
6. Before leaving the installation site, make sure that the sensor is operating properly and instruct the building 2 : Sensitivity potentiometer
(1) (3) (2) (4) (1)
owner/operator on proper operation of the door and the sensor. 3 : Mode setting switches
7.The sensor settings can only be changed by an installer or service engineer. When changed, the 1ST ROW 2nd & 3rd ROW
4 : Area width setting switch
changed settings and the date shall be registered in the maintenance logbook accompanying the door. IMMUNITY
5 : 1st row angle screw
OPERATION INDICATOR 6 : 1st row area angle gauge
WARNING (10) (10)
Green : Stand-by
(4)
(0.5 to 10sec.) (0.5 to 10sec.)
Min Max Min Max
Model (System name) : Swing-Guard T / Swing-Guard T LE Model (Sensor head) : 700356 3 : N/A
Door Mode 1 2 3 4 5 6 7 8 Manufacturer
code
1 5 6 7 8
Full Low
energy energy
Power supply : 12 to 24VAC ±10% (50 / 60Hz) Cover color : Black 4 : N/A
Sensor active
85(3 2/8")
(5)
mode
2
Always Only on Operation
active closing Indicator
12 to 30VDC Mounting height : 2.0 (6'7") to 2.5m (8'2") 5 : Activate input(+) Purple
Activation
operation 700357
0.6(2')
3
Auto Knowing
Power consumption : < 3.5W (< 4VA at AC) Detection area : See DETECTION AREA
Act
(6)
Master Slave
(Swing-Guard T) at 2 700356 Sensor head & Detection method : Active infrared reflection ** 7 : N/A
Activate
Activate
Safety
output
output
output
Made in Japan
input
Stall
LOT.xxxxyzzzz
Power : AC 12-24V
1 700357 Controller Depth angle adjustment : 1st row area ±5° 8 : N/A
DC 12-30V
WIRING Color STANLEY Door controller
Power supply(+) Red TB1 PIN1
Communication TXD Green TB1 PIN2
Power consumption : < 3.5W (< 4VA at AC) 2nd & 3rd row area ±5° 9 : N/A
Communication RXD White TB1 PIN3
Power supply(-) Black TB1 PIN4
Activate input Purple Directly to 700357
(1)
NOTE Self-monitoring is performed in Sensor head, Controller, and Daughter board. (6)
50(1 15/16")
When the result of Self-monitoring is positive as a system, LED of each unit shows such result. (2) (7)
Position error Green & Orange blinking 1650 (5'5") 1898 (6'2")
F
Mixed version error Red & Green blinking
G 252 (10")
Interface LED : 700357 Controller
LED indication When outputting H 593 (1'11") 645 (2'1")
E
700356
Red : Swing Area Det.
Yellow Blink : Learning ON, and supply 115VAC to the controller.
(2) After supplying 115VAC, within 4sec., press "First / Reset auto learn
switch" for approx. 2sec.
1st area depth angle must be set to Start with 2nd & 3rd area depth angle at +5 degrees(deep). NOTE See Swing-Guard T / Swing-Guard T LE installation manual
+5 degrees (deep) If after walk test the pattern is too deep, adjust towards section 10 (Setup process).
shallow as necessary. When failed to complete First / Reset auto learn, repeat the First / Reset auto learn switch
procedure above from step "1".
2 Adjusting the Sensitivity
Adjust the sensitivity to your installation
3 Initial setup
This sensor has the function to fit floor condition 2 Setting the dipswitches
environment. changes automatically. Set the dipswitches as shown below.
1st row area 2nd & 3rd row Therefore, even if objects are put in the detection NOTE * If dipswitch 1 set to ON (UP) after
sensitivity area sensitivity area, sensor will learn the changes gradually and 10sec. of continuous stall
potentiometer potentiometer
set back to normal operations automatically after 700357 Controller emits a creep
several detections. Dipswitch setting OFF ON signal.
** Please set the dipswitch 2 as for
Min Max Min Max To enable an Swing-Guard T / Swing-Guard T LE 1 Creep feature * OFF ON the door type and position.
Learn process only, flip any dipswitch on either 2 Door setting ** Single Double
the swing or approach side 700356 Sensor head Continuous stall can occur when both an
OPERATION INDICATOR 3 Future development N/A N/A activation signal and stall signal occur at the
and then flip it back to the original position
(necessary on only one sensor per door panel only). 4 Future development N/A N/A same time.
After 10 seconds a creep signal is emitted and
700356 NOTE See Swing-Guard T / Swing-Guard T LE the door will creep to the full open position.
1st row area 2nd & 3rd row area installation manual section 10
sensitivity potentiometer sensitivity potentiometer (Setup process).
INFORM BUILDING OWNER / OPERATOR OF THE FOLLOWING ITEMS
4 Area width setting switch
(Right bank)
5 Mode setting switch
(Left bank) WARNING
1. Always keep the detection window clean. If dirty, wipe the window with a damp cloth.(Do not use any cleaner / solvent.)
Set the dipswitch as necessary.
1,2 : Presence timer 2. Do not wash the sensor with water.
Active : Enable area
3 : Frequency 3. Do not disassemble, rebuild or repair the sensor yourself, otherwise electric shock may occur.
Inactive : Disable area Active Inactive
MUNITY
4 : Rain mode 4. When the operation indicator Green blinking, contact installer or service engineer.
5 : Snow mode 5. Always contact your installer or service engineer when changing the settings.
6 : Area depth 6. Do not paint the detection window.
7 : Hinge side
8 : Sensor side
NOTE 1. After applying power, wait 10 seconds then walk test detection area to ensure proper operation.
2. Do not place any objects that move or emit light in the detection area. (e.g. Plant, illumination, etc.)
NOTE Whenever a dipswitch is moved an Swing-Guard T / Swing-Guard T LE Learn process is enabled, ensure
proper completion of process (See step 3).
TROUBLESHOOTING
5-1. Setting the Presence timer 5-2. Setting the Frequency Operation indicator
To comply with ANSI standard, set to "30sec." or longer. When using more than one Symptom 700356 Possible cause Possible countermeasures
Sensor 700357
sensor close to each other, Controller
15 Sec. 30 Sec. 60 Sec. 120 Sec. set the different frequency Setting1 Setting2 head
for each sensor by Initial setup None None Power supply voltage. Set to the stated voltage.
dipswitches 3. can not start. Wrong wiring cable (Red & Black wires) Check the wiring cable.
1 2 1 2 1 2 1 2 3 3 of 700357 Controller.
5-3. Setting the Rain mode 5-4. Setting the Snow mode Green & Orange Wrong wiring cable (Green & White wires) Check the wiring cable.
Set dipswitch 4 to "Rain" if the sensor malfunctions. Set dipswitch 5 to "Snow" blinking of 700357 Controller.
if the sensor is used in Twice Twice Connection failure from 700356 Sensor head Check the connector.
NORMAL RAIN NORMAL SNOW to 700357 Controller.
a region with snow or a Orange Orange
NOTE When set to "Rain", lot of insects. blinking blinking Connection failure to both 700356 Sensor head. Check the connector.
the actual detection area or
Defective communication cable. Replace as necessary.
may become smaller. 4 4 5 5 None
Dipswitch setting are set for Full energy Check controller’s setting.
application when only one sensor is See installation manual section 7.
5-5. Setting the Area depth DEEP SHALLOW installed.
Change dipswitch 6 to "SHALLOW" if false detections occur Dipswitch setting are set for Low energy Check controller’s setting.
from cross traffic / close by objects. In "SHALLOW" mode the application when more than 2 sensors are See installation manual section 7.
shallow pattern is applied only during the opening and closing 6 6 connected.
cycles. Slow When all the area are inactive. (Right bank Verify proper settings.
Orange
blinking dipswitches on 700356 Sensor head) See installation manual section 8.
Incomplete Blinking Blinking 700357 Controller dipswitches set wrong. Check the dipswitch settings.
initial setup. Yellow Green
Door operates Solid Proper After initial setup door ghosts several times Happens on 15% of installations if stops
5-6. Setting the Hinge side 5-7. Setting the Sensor side when no one Green on first activation after first activation, system is OK.
is in the or
When facing the 700356 Sensor head, if the hinge is If you install the 700356 Sensor head on swing side, Improper 1st row or 2nd & 3rd row area Set 1st row or 2nd & 3rd row area angle
detection area. Solid
to the right of the sensor set dipswitch 7 to choose "SWING SIDE", if non-swing side, choose angle adjustment. at +5 degrees (deep).
(Ghosting) Red
"RIGHT SIDE". If hinge is to the left of the sensor set "APPROACH SIDE". For low energy application, or Stalling caused by traffic just outside of Set dipswitch 6 on left bank dipswitch of
the dipswitch 7 to "LEFT SIDE". mount 700356 Sensor head on approach side, and Blinking swing path. 700356 Sensor head on / up (shallow) .
set dipswitch 8 to "APPROACH SIDE". Red
RIGHT SIDE LEFT SIDE Objects near guide rails. Remove the objects.
APPROACH
SWING SIDE Area width dipswitches set wrong. (Right Verify proper settings.
SIDE
bank dipswitches on 700356 Sensor head) See installation manual section 8.
7 7 Wet floor. Check the installation condition referring
8 8 The exhaust emission or fog penetrate to MANUFACTURER'S STATEMENT.
into the detection area.
Reflecting objects in the detection area. Remove the objects.
Objects that move or emit light
(Ex.Plant, illumination, etc.)
NOTE Sensor system does not operate when dipswitch 7 or 8 are set the Water drops on the detection window. Use the rain-cover
same on both sides of door. (Separately available). Or install in a
place keeping the waterdrops off.
ADJUSTMENTS for 700357 Controller Sensitivity is too high. Adjust the Sensitivity lower.
Snow drifting. Set the Snow mode to ON.
1 Hold time adjustment
Adjust the output hold time for site.
Other than above. Set the Rain mode to ON.
Safety output Stall output Door does not Solid Proper Sensitivity is too low. Adjust the Sensitivity higher.
hold time hold time operate properly Green Area width dipswitches set wrong. (Right
NOTE For STANLEY Door controller, Min Max Min Max
when a person
Verify proper settings.
(0.5 to 10sec.) (0.5 to 10sec.) bank dipswitches on 700356 Sensor head) See installation manual section 8.
leave both fully counter clockwise. enters the
detection area. On Knowing Act applications poor or Verify proper connection.
2 Setting the dipswitches
Set the dipswitches as shown below.
(Sensor does not
detect.)
improper connection of Purple wires from
700357 Controller to activation device.
See installation manual section 5.
Slow Proper Improper 1st row or 2nd & 3rd row area Set 1st row or 2nd & 3rd row area angle
Dipswitch setting OFF ON Green angle adjustment. at +5 degrees (deep).
blinking Signal saturation. Remove highly reflecting objects from the
1 Door mode Full energy Low energy detection area. Or lower the Sensitivity.
2 Sensor active mode Always active Only on closing Fast Twice Dirty detection window. Wipe the detection window with a damp
3 Activation operation Auto. Knowing Act NOTE * When connected a single door Green Orange cloth. (Do not use any cleaner or solvent.)
(one door), select "Master blinking blinking
4 Controller selection * Master (Encoder 1) Slave (Encoder 2) Sensor failure. Contact your installer or service engineer.
(Encoder 1)".
5 When connecting to a double door Sensor detects Red or Proper 700357 Controller dipswitches set wrong. Check the dipswitch settings.
Manufacturer code but door does Blinking See installation manual section 7.
6 (Checkbox on the right are (two doors), select "Master
not operate. Red
(Encoder 1)"
7 setting for STANLEY Door
controller) and "Slave (Encoder 2)" Door remains Solid Proper On Knowing Act applications poor or Verify proper connection.
8 respectively. open. Green improper connection of Purple wires from See installation manual section 5.
700357 Controller to activation device.
Dipswitch OFF ON
Improper wiring of door equipment Verify proper wiring of on / off / hold
1 2 3 Settings on / off / hold switch. switch.
Full Sensor is always enabled. (Auto)
energy Sensor is only enabled upon output from activation devices. (Knowing Act) Manufacturer North and South America Subsidiary
Door type
Sensor is always enabled. (Auto) OPTEX Co.,LTD. OPTEX INCORPORATED East coast office
Low Sensor is only enabled upon output from activation devices. (Knowing Act) 5-8-12 Ogoto Otsu 520-0101, Japan 18730 S. Wilmington Avenue, Suite 100 8510 McAlpines Park Drive, Suite 108
energy TEL.: +81(0)77-579-8700 Rancho Dominguez CA 90220 U.S.A Charlotte, NC 28211 U.S.A.
Sensor is enabled upon output from activation devices or door is at full open position.
(Only on closing) FAX.: +81(0)77-579-7030 TEL.: +1-800-877-6656 TEL.: +1-800-877-6656
WEBSITE: FAX.: +1(310)898-1098 FAX.: +1(704)365-0818
NOTE Swing-Guard T /Swing-Guard T LE may not operate properly with settings other than listed above. www.optex.co.jp/as/eng/index.html WEBSITE: www.optextechnologies.com WEBSITE: www.optextechnologies.com