0980476382

02 500 4600
MEGAFRIOSA
MEGAFRIO_SA
MEGAFRIO_SA

WWW.MEGAFRIOSA.COM
60Hz Top-discharge
60Hz Top-discharge
Condensing
Condensing Unit Unit

48/60k Btu/h

24/36k Btu/h

Features
Features
High efficiency compressor 24V communication
Famous brand high efficiency rotary compressor for 24V universal communication connection, safe and reliable,
24/36K model, and scroll compressor for 48/60k and it allows to connect with 3rd party indoor units, very
model, reliable quality and quiet operation. suitable for equipment renewal projects.

Pic.1 Pic.2 Pic.3

Pic.4 Pic.5 Pic.6

Fixed Scroll Active Scroll Compressing Area

Scroll Comp. Sroll Plate Working Principle

High efficiency condenser Golden fin


Composed of inner groove copper tube and hydrophilic Golden hydrophic aluminum fins for option.
aluminum foil, which has better heat exchange efficiency.

Condenser guard grille


Optional louvered steel grille and standard plastic grille
can be selected to effectively protect the condenser.
Multi protections
60Hz ON/OFF SERIES
Discharge Temp. Sensor T3 Low Pressure High Pressure
Protection Protection Protection Protection Louvered steel grille Plastic grille
Specification Specification
60Hz R410A Heat Pump 60Hz R410A Cooling Only
Outdoor unit COT-24HNR1 COT-36HNR1 COT-48HNR1 COT-60HNR1 Outdoor unit COT-24CNR1 COT-36CNR1 COT-48CNR1 COT-60CNR1
Power supply V/Hz/N 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 Power supply V/Hz/N 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1

Capacity Capacity

Btu/h 24000 36000 48000 60000 Btu/h 24000 36000 48000 60000
Cooling Cooling
RT 2 3 4 5 RT 2 3 4 5

Btu/h 26400 39600 52800 66000 Physical data


Heating
RT 2 3 4 5 CFM
Air flow volume 2600 2600 3200 3200
Physical data Noise level dB(A) 60 60 65 60

Air flow volume CFM 2600 2600 3200 3200 mm 554x554x633 554x554x633 740x740x835 740x740x835
Net dimension(WxDxH)

Noise level dB(A) 60 60 65 65 mm 575x575x660 575x575x660 760x760x875 760x760x875


Packing dimension(WxDxH)

Net dimension(WxDxH) mm 554x554x635 554x554x675 740x740x835 740x740x835 46 46.5 74 74.5


Net weight kg

Packing dimension(WxDxH) mm 575x575x690 575x575x690 760x760x875 760x760x875 49 49.5 78.5 79


Gross weight kg

kg 52 60 80 91
Net weight Piping data

kg 55 63 84 96 Liquid size in 3/8" 3/8" 3/8" 3/8"


Gross weight

Piping data Gas size in 5/8" 3/4" 3/4" 3/4"

Liquid size in 3/8" 1/2" 1/2" 1/2" Max. pipe length m 20 20 20 20

Gas size in 5/8" 3/4" 3/4" 3/4" Max. height difference m 10 10 10 10

Max. pipe length m 20 20 20 20

Max. height difference m 10 10 10 10

60Hz R410A Cooling Only


60Hz R410A Heat Pump Outdoor unit COT-36CXR1 COT-48CXR1 COT-60CXR1 COT-48CYR1 COT-60CYR1

Outdoor unit COT-36HXR1 COT-48HXR1 COT-60HXR1 COT-48HYR1 COT-60HYR1 Power supply V/Hz/N 208-230/60/3 208-230/60/3 208-230/60/3 380-415/60/3 380-415/60/3
Power supply V/Hz/N 208-230/60/3 208-230/60/3 208-230/60/3 380-415/60/3 380-415/60/3 Capacity

Btu/h 36000 48000 60000 48000 60000


Capacity Cooling
Btu/h 36000 48000 60000 48000 60000 RT 3 4 5 4 5
Cooling Physical data
RT 3 4 5 4 5

Air flow volume CFM 2600 3200 3200 3200 3200


Btu/h 39600 52800 66000 52800 66000
Heating
Noise level dB(A) 60 65 65 60 60
RT 3 4 5 4 5

Net dimension(WxDxH) mm 554x554x675 740x740x835 740x740x835 740x740x835 740x740x835


Physical data

2550 5440 5440 5440 5440 Packing dimension(WxDxH) mm 575x575x690 760x760x875 760x760x875 760x760x875 760x760x875
Air flow volume CFM

60 66 65 65 65 Net weight kg 58 72 72 72 72
Noise level dB(A)

554x554x675 740x740x835 740x740x835 740x740x835 740x740x835 Gross weight kg 61 77 77 77 77


Net dimension(WxDxH) mm

575x575x690 760x760x875 760x760x875 760x760x875 760x760x875 Piping data


Packing dimension(WxDxH) mm

60 80 80 80 80 Liquid size in 3/8" 3/8" 3/8" 3/8" 3/8"


Net weight kg

63 84 84 84 84 Gas size in 3/4" 3/4" 3/4" 3/4" 3/4"


Gross weight kg
Max. pipe length m 20 20 20 20 20
Piping data

Liquid size in 1/2" 1/2" 1/2" 1/2" 1/2" Max. height difference m 10 10 10 10 10

Gas size in 3/4" 3/4" 3/4" 3/4" 3/4"


1.The cooling condition: T1 condition: indoor side 27℃(80.6℉) DB, 19℃(60℉) WB, outdoor side 35℃(95℉) DB;
Max. pipe length m 20 20 20 20 20 2.The heating condition: indoor side 20℃(68℉) DB, 15℃(44.6℉) WB, outdoor side 7℃(42.8℉) DB
Note 3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Max. height difference m 10 10 10 10 10 4.The above data may be changed without notice for future improvement on quality and performance.

1.The cooling condition: T1 condition: indoor side 27℃(80.6℉) DB, 19 (60℉) WB, outdoor side 35℃(95℉) DB;
2.The heating condition: indoor side 20℃(68℉) DB, 15℃(44.6℉) WB, outdoor side 7℃(42.8℉) DB
Note 3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
4.The above data may be changed without notice for future improvement on quality and performance.
Floor & Ceiling Unit
Specification
60Hz R410A Cooling Only(New)
Wired Indoor unit CUAi-24CR1 CUAi-36CR1 CUAi-48CR1 CUAi-60CR1-B
(Optional)
Power supply V/Hz/N 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1
Wireless
(Standard)
Capacity
24k Btu/h 36K Btu/h Btu/h 24000 36000 48000 60000
Cooling Capacity
RT 2 3 4 5

Physical data

Wireless Air flow volume (Hi/Med/Low) CFM 880/760/640 880/760/640 1230/1110/1000 1230/1110/1000
(Optional)
Noise level (Hi/Med/Low) dB(A) 51/48/46 57/54/52 58/55/52 58/55/52

Net dimension(WxDxH) mm 1050x235x676 1250x235x675 1670x235x675 1670x235x675


48/60K Btu/h Packing dimension(WxDxH) mm 1130x325x765 1380x325x765 1750x325x770 1750x325x770

Net weight kg 27 32 40 40

Features Gross weight kg 31 37 46 46

Piping data

Flexible installation Optional water pump Liquid in 1/4" 3/8" 3/8" 3/8"

Piping size Gas in 1/2" 3/4" 3/4" 3/4"


Flexible installation, you can choose ceiling suspend- Water pump is optional, the pumping head is up to 700mm.
ed or floor standing installation style according to Drainage in 1" 1" 1" 1"
your project requirement.
1.The cooling condition: T1 condition: indoor side 27℃(80.6℉) DB, 19℃(60℉) WB, outdoor side 35℃(95℉) DB;
2.The heating condition: indoor side 20℃(68℉) DB, 15℃(44.6℉) WB, outdoor side 7℃(42.8℉) DB
Note 3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
4.The above data may be changed without notice for future improvement on quality and performance.

AC fan motor Digital display


AC motor is standard, stable operation, high efficiency Digital display is standard, on the right side. It is more intuitive
and low noise. and simple, and error code can be shown in the display.

Washable filter
Long term filter can effectively remove PM2.5 in the air, and it
could be take out from grille easily to clean, aims to provide
healthy indoor environment. 3D airflow

washable
Auto-swing function, built-in two louver motor,
vertical and horizontal air-flow adjustment.
Floor
filter

Ceiling
Take out from grille

Optional honeycomb grille


Horizontal grille is standard, and honeycomb type is available
for your customization.

Horizontal Type Grill Honeycomb Type Grill


(Standard) (Optional)
Round flow cassette
Features
Washable filter Cold catalyst filter(optional)
Long term filter can effectively remove PM2.5 in the It can initiate a catalytic reaction under normal temperature
Wired air, and it could be take out from grille easily to clean, and pressure, decompose a variety of harmful and odorous
(Optional) gases into harmless and odorless substances under normal
aims to provide healthy indoor environment.
Wireless
temperature and pressure, effectively remove formaldehyde,
(Standard) benzene, xylene, toluene, TVOC and other harmful gases, and
provide a fresh and healthy interior environment.

1 2
Wireless
(Optional) 3 4
Filter can be taken
from the panel

18K-60K Btu/h
it is washable

Features
360° air supply Fresh air intake
Round-flow ceiling mounted cassette adopts 360° air supply Four interfaces to connect with duct for fresh air intake,
panel design, it could distributes comfort to every corner of provides healthy indoor environment.

Specification
the room.

Fresh air

60Hz R410A Cooling Only


Indoor unit CCR-24CR1 CCR-36CR1 CCR-48CR1 CCR-60CR1
Power supply V/Hz/N 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1
V/Hz/Ph

Capacity
Btu/h
RT Btu/h 24000 36000 48000 60000
Cooling Capacity
Btu/h RT 2 3 4 5
Digital display 3D fan blade Physical data RT

Air flow volume (Hi/Med/Low) CFM 710/600/500 1000/860/740 1200/1000/800 1200/1000/800


Digital tube display is optional your choice, standard Streamlined design 3D spiral fan blade, reduces air resistance
is LED display. and operation noise. Noise level (Hi/Med/Low) dB(A) 52/48/45 52/48/45 57/54/51 52/48/45
Net dimension Body mm 840x230x840 840x285x840 840x285x840 840x285x840
(WxHxD) Panel mm 950x50x950 950x50x950 950x50x950 950x50x950
Packing Body
Three-dimensional mm 920x265x920 920x265x920 920x310x920 920x310x920
spiral fan blade dimension
(WxHxD) Panel mm 1030x105x1030 1030x105x1030 1030x105x1030 1030x105x1030
Body kg 28 28 31 31
Option Standard type Diffuser Net weight
Panel kg 5.4 5.4 5.4 5.4
Body kg 32 32 35 35
Gross weight
Panel kg 8 8 8 8
Ultra-thin body Water pump Applicable area m² 28-50 40-70 55-95 60-105
Piping data
Ultra-thin body design, the min. height is only Built-in water pump, water head up to 1200mm.
Liquid in 3/8" 3/8" 3/8" 3/8"
230mm, save installation space.
Piping size Gas in 5/8" 3/4" 3/4" 3/4"
Drainage in 1" 1" 1" 1"

1200mm
230mm 1.The cooling condition: T1 condition: indoor side 27℃(80.6℉) DB, 19℃(60℉)WB, outdoor side 35℃(95℉) DB;
2.The heating condition: indoor side 20℃(68℉) DB, 15℃(44.6℉)WB, outdoor side 7℃(42.8℉)DB
Note 3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
4.The above data may be changed without notice for future improvement on quality and performance.
Ducted unit
Specification
60Hz R410A Cooling Only
Wired Wired
(Standard) (Optional) Indoor unit CTB-24CR1 CTB-36CR1 CTB-48CR1 CTB-60CR1
Power supply V/Hz/N 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1

Capacity

Btu/h 24000 36000 48000 60000


Cooling
RT 2 3 4 5

Physical data

Air flow volume(Hi/Med/Low) CFM 680/600/480 1170/940/760 1170/940/760 1170/940/760


Wireless
(Optional) Noise level(Hi/Med/Low) dB(A) 52/45/40 50/47/45 56/54/51 56/54/51

Net dimension(WxDxH) mm 1190x643x260 1190*643*260 1425x643x260 1425x643x260

Packing dimension(WxDxH) mm 1255x720x325 1255x720x325 1490x720x325 1490x720x325

Net weight kg 32 32 46 46

Features Gross weight

Applicable area
kg

m 2
36

28-50
36

40-70
50

55-95
50

60-105

Ultra-thin body Flexible installation Piping data

Liquid in 3/8" 3/8" 3/8" 3/8"


Ultra-thin body design, Installation space is greatly Ducted could be easily connected according to the various
reduced. The thickness of the three cases are 210mm, project demands, especially for complex projects. And the ESP Pipe size Gas in 5/8" 3/4" 3/4" 3/4"
260, 370mm respectively. of short duct, medium ESP duct, high ESP duct are 30Pa, 70Pa,
Drainage in 1" 1" 1" 1"
150Pa respectively.

Short duct 210mm

Medium ESP duct 260mm


1.The cooling condition: T1 condition: indoor side 27℃(80.6℉) DB, 19℃(60℉) WB, outdoor side 35℃(95℉) DB;
2.The heating condition: indoor side 20℃(68℉) DB, 15℃(44.6℉)WB, outdoor side 7℃(42.8℉)DB
High ESP duct 370mm Note 3. Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
4.The above data may be changed without notice for future improvement on quality and performance.
L Shape U Shape I Shape

Centrifugal fan Washable filter


Adopting aviation centrifugal fans, and CFD technology Long term filter can effectively remove PM2.5 in the air, and it
design, increasing air volume and decreasing noise could be take out from grille easily to clean, aims to provide
level, noise level only 29dB(A) for Low ESP Ducted Unit. healthy indoor environment. And the filter could be take out
from different direction which is convenience for clean.

20dB(A)

30dB(A)

Fan speed Air return


Three fan speed, meet different requirements. Air return from rear or bottom is easy to change on site
according to actual situation, convenient for installation.

Air inlet frame Air inlet block board


Filter

Filter
Air inlet block board
Air inlet frame

Air outlet
Air outlet

Air inlet Air inlet


Air inlet from rear Air inlet from bottom
Air Handling Unit Rooftop Package Unit

Controller

Wired Wired
3/4/5 TR (Standard) (Optional)

36/60K Btu/h

Features
Features High efficiency: Word famous
Scroll compressor with quick
Fresh air inlet is available.

reactivity and operation stable.


Compressor staging is Flexible installation, whether on rooftop
Use R410A refrigerant, can be matched Easily controlled by thermostate and controlled directly by the or ground. Anywhere removable as
with top-discharge condensing unit. compatible with other manufactor's control temperature, high EER. requirement without fixed.
products.
Provide easy access to system components
for maintenance and service.

Centrifugal fan rotor with a stastic


pressure of 50 Pa, can provide large
Flexible installation, can be installed
vertical or horizontal. Specification
air volume.
R410A
Outdoor unit CRS-036CNR1-W CRS-048CNR1-W CRS-060CNR1-W
Specification Cooling Btu/h 36000 48000 55000
Capacity
Heating Btu/h / / /

EER 10.3 10.7 10.0

Indoor unit CAHi-36CNR1 CAHi-60CNR1 Dimension(WxHxD) mm 1130x754x825 1130x754x825 1130x754x825


Power supply V/Hz/N 208-230/1/60 208-230/1/60 Net weight kg 135 135 135

Drive type Axial flow Axial flow Axial flow


Capacity
Motor quantity 1 1 1
Btu/h 36000 60000
Cooling Capacity Input W 452 452 452
RT 3 5 Outdoor fan
Output W 230 230 230
Physical data
Speed r/min 1110 1110 1110
Air flow volume CFM 1000 1470
Rated current A 1.9 1.9 1.9
External static pressure (Hi) Pa 37 50
Drive type FC centrifugal FC centrifugal FC centrifugal
Noise level dB(A) 51-56 51-57
Motor quantity 1 1 1
Indoor Unit (WxHxD) mm 460x774x520 500x970x550
dimension Input W 527 527 527
Packing (WxHxD) mm 520x834x565 560x1030x595 Indoor fan
Output W 350 350 350
Net weight kg 37 45
Speed r/min 1045 1045 1045
Gross weight kg 39 48
Rated current A 2.4 2.4 2.4

1.The cooling condition: T1 condition: indoor side 27℃(80.6℉) DB, 19℃(60℉) WB, outdoor side 35℃(95℉) DB; 1.The cooling condition: T1 condition: indoor side 27℃(80.6℉) DB, 19℃(60℉) WB, outdoor side 35℃(95℉) DB;
2.The heating condition: indoor side 20℃(68℉) DB, 15℃(44.6℉) WB, outdoor side 7℃(42.8℉)DB
Note
2.The heating condition: indoor side 20℃(68℉) DB, 15℃(44.6℉) WB, outdoor side 7℃(42.8℉)DB
3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Note 3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
4.The above data may be changed without notice for future improvement on quality and performance. 4.The above data may be changed without notice for future improvement on quality and performance.

23 24
Controllers

Wireless Controller

Wireless 8m transmission Temperature control range 16-32℃


5 operation mode: Auto, Cooling, Dehumidification, Heating,Fan Three fan speed selection
Timer ON/OFF setting up to 24Hr Sleep mode function

Wired Controller

LCD display Timer ON/OFF setting up to 24Hr


5/8/10 m wire length Temperature control range 16-32℃
5 Operation modes: Auto, Cool, Dehumidification, Heat, Fan Three fan speed selection

14 SEER AIR
CONDITIONER
14 SEER ODU
Specification
1 R410a environmentally friendly refrigerant. 2 Painted galvanized steel cabinet.
14SEER condenser R410A Cooling Only
Outdoor unit COT-24CNR1-14 COT-36CNR1-14
Power supply V/Hz/N 208-230/60/1 208-230/60/1

3
Capacity
24V low voltage control Btu/h
Cooling capacity 24000 36000

Input W 1960 2830

SEER (AHRI Certified) 14 14

Physical data

Air flow volume CFM 1700 2800

Noise level dB(A) 60 60

4 The world famous brand scroll compressor with


quick reactivity,stronger and operation stable.
5 Various coil guard optional. Louvered steel coil
guard is standard, and it is acceptable to customize
Net dimension(WxDxH)

Packing dimension(WxDxH)
mm

mm
554x554x635

575x575x660
740x740x635

760x760x660

plastic net. Net weight kg 52 70

Gross weight kg 54 74
Pic.1 Pic.2 Pic.3
Piping data

Liquid size in 3/8" 3/8"

Pic.4 Pic.5 Pic.6 Gas size in 3/4" 3/4"

Fixed Scroll Active Scroll Compressing Area Max. pipe length m 15 15

Scroll Comp. Sroll Plate Working Principle Max. height difference m 8 8

6 Intelligent defrost programs, unit will choose


different defrost program according to real
7 AC motor is adopted, which is single speed.
14SEER condenser R410A Cooling Only
condition. Outdoor unit COT-48CNR1-14 COT-60CNR1-14
Power supply V/Hz/N 208-230/60/1 208-230/60/1

Capacity

Cooling capacity Btu/h 48000 60000

Input W 4088 4920

SEER (AHRI Certified) 14 14

8 Multi protections to avoid unit broken. 9 Condenser coils constructed with copper tubing
and enhanced aluminum fins.
Physical data

Air flow volume CFM 4000 4000

Noise level dB(A) 63 63

Net dimension(WxDxH) mm 740x740x835 740x740x835

Packing dimension(WxDxH) mm 760x760x875 760x760x875

Net weight kg 94 101


Discharge Temp. Sensor T3 Low Pressure High Pressure
Gross weight kg 98 104
Protection Protection Protection Protection
Piping data

10 Anticorrosion choice. 11 Wide operation temperature range Liquid size

Gas size
in

in
3/8"

7/8"
3/8"

7/8"
Golden fin
Max. pipe length m 18 18

Cooling range: 64℉- 109℉ Max. height difference m 10 10

Heating range: 20℉-109℉


1.The cooling condition: T1 condition: indoor side 27℃(80.6℉) DB, 19℃(60℉) WB, outdoor side 35℃(95℉) DB;
Intensified moisture proof PCB
12 AHRI Certified & ETL Listed.
2.The heating condition: indoor side 20℃(68℉) DB, 15℃(44.6℉) WB, outdoor side 7℃(42.8℉) DB
Note 3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
4.The above data may be changed without notice for future improvement on quality and performance.

You might also like