Heating, Ventilation & Air Conditioning

(HVAC) Design using HAP


Instructor-Led Online Training
Course Curriculum (Duration: 40 Hrs)

Chapter 1: Introduction to HVAC

 What is HVAC?
 Understanding Sensible Heat, Latent Heat and Enthalpy
 Standards and codes used in HVAC

Chapter 2: Modes of Heat Transfer

 Conduction
 Convection
 Radiation

Chapter 3: Refrigeration Cycles

 Basic Refrigeration System or Vapor Compression Cycle


 Types of Compressors, Condenser, Expansion Valve & Evaporator Coil,
 Temperature TON of Refrigeration
 Commonly used metrics, units and conversions

Chapter 4: Psychometrics

 Psychometrics definition
 Dry Bulb Temperature
 Wet Bulb Temperature
 Dew point Temperature
 Relative Humidity
 Humidity Ratio
 Processes
 Heating
 Cooling
 Cooling and Dehumidification
 Heating and Humidification
 Finding Values Using the Chart (Manually and using software)

1
Chapter 5: Types Air-Conditioning System and Equipment

 Window A/C
 Split A/C
 Ductable Split A/C
 Variable Refrigerant Volume (VRV)/Variable Refrigerant Flow (VRF)
 Ductable Package A/C
 Package Roof Top Units
 Central Plant Chilled Water System

Chapter 6: Comfort Conditions and Cooling Load Calculations

 Comfort Parameters
 Understanding Indoor & Outdoor Design Conditions
 Cooling load calculation methods
 Calculation of U values
 Sources of Heat Gain
 External :
 Heat Gain through Glass/Window
 Heat Gain through Roof/Wall/ Wall Partition gain
 Internal:
 Heat Gain through People, Lights, Electrical Equipments, Motors, Kitchen
Appliances
 Heat gain through Infiltration air
 Heat gain through Ventilation
 ESHF, ADP & Air Flow Rate(CFM) Calculation
 Cooling load calculation manually using E-20 form
 Cooling load calculation using HAP (Hourly Analysis Program)

Chapter 7: Air Distribution System- Ducting and Air Terminals

 Duct-Definition & Terminology


 Types of Ducts, Duct fittings, Dampers, Flexible ducts
 Classification of Duct(Low, Medium & High pressure)
 Selection of Duct Gauges & thickness
 Comparison between different shapes of duct, Duct Fabrication, Insulation &
Installation procedure
 Type of Duct Materials, Calculation of total sheet required for Duct Fabrication &
Estimating duct weight in kgs
 Ducts-Sizing
 Selection of Grills and Diffusers
 Duct designing methods (Manually)
 Velocity reduction method.
 Equal friction Method.
 Static regain method
 Fan selection & ESP calculation.
 Components of Air Distribution System
 Concept of CAV & VAV

2
Chapter 8: Design of Ventilation system

 Fresh Air Handling Unit Designing as per ASHRAE 62.1


 Restaurant/Residence kitchen ventilation system designing as per ASHRAE 90.1
 Non Central and Central Toilet Exhaust Calculations as per ASHRAE 62.1
 Car Parking Ventilation system Designing

Chapter 9: Refrigerants

 Types of refrigerant
 Evaporating & condensing properties of refrigerant
 Refrigerant Pipe sizing methods

Chapter 10: Chilled Water Distribution System

 Chilled water system components


 Various types of Chillers
 Chilled water pipe sizing as per ASHRAE standards
 Typical Installation of Chilled water FCU and AHU
 Valves and accessories used in Chilled water system
 District cooling system

Chapter 11: Pumps Design

 Pump classifications
 Selection of Pump
 Pump Head Calculation

Chapter 12: Cooling Tower

 Types of cooling tower


 Cooling tower water losses
 Cycles of concentration
 Cooling tower selection

Chapter 13: SOFTWARES

 Load calculation using Hourly Analysis Program (HAP)


 Calculation of duct sizes by McQuay Duct sizer
 Calculation of Chilled water pipe sizes by McQuay pipe sizer Software
 Psychometry Software
 Air terminal (Grills, Diffusers, Registers, LBG-Linear Bar Grills, SLSD-Supply
Linear Slot Diffuser) selection by using BETA Program