Unidades Evaporadoras Serie AVS
Unidades Evaporadoras Serie AVS
Indoor Unit
A
F
conditions. Btu/h 5,800 7,500 9,600 12,300 15,400 19,100 24,200 28,700
greatly in comparison to the old AC product. The minimum power consump-
Capacity
tion is only 20W, which is reduced by 60%. It can achieve low-cost opera- Rest Working Exercise kW 2.0 2.5 3.3 4.0 5.0 6.3 8.0 8.4
Heating
tion. Btu/h 6,500 8,500 11,300 13,700 17,100 21,500 27,300 28,700
Cooling W 20 20 20 30 20 30 50 80
Power Input
60% Heating W 20 20 20 30 30 30 70 80
Sound Pressure dB(A) 33/32/32/30/30/28 36/35/33/32/30/28 36/35/33/32/30/28 38/35/33/32/30/28 38/37/36/32/31/29 40/38/36/35/33/31 45/42/41/38/35/31 50/48/45/41/36/33
Power Input 8.7/8.3/8.2/ 9.8/9.2/8.7/ 9.8/9.2/8.7/ 10.3/9.2/8.7/ 11.5/11.0/10.3/ 16.2/15.0/14.2/ 20.0/18.0/17.0/ 23.3/22.0/20.0/
Reduced by Airflow Rate m3/min
7.5/7.2/7.0 8.2/7.5/7.0 8.2/7.5/7.0 8.2/7.5/7.0 9.0/8.7/8.0 13.3/12.2/11.5 15.0/13.3/11.7 17.0/14.2/12.2
Liquid mm Φ 6.35
Piping
1/4" Φ 6.35
1/4" Φ 9.53
3/8"
1 Fan Speed 2 Fan Speed 3 Fan Speed 4 Fan Speed 5 Fan Speed 6 Fan Speed Gas mm Φ 9.53
3/8" Φ 12.70
1/2" Φ 15.88
5/8"
Condensate Drain VP 16
Optimal noise control Self-cleaning function
Net Weight kg 9.0 13.0 14.5
The low-noise DC fan motor and the enhanced vibration pad on the distri- Featured with self-cleaning technology, the evaporator can be Weight
bution pipe and EEV will ensure a quieter operation. Besides, with Hisense self-cleaned automatically just with the tap of a button in the controller, Gross Weight kg 12.5 17.0 19.0
special smart noise reduction technology, the operation noise can also be which is very convenient and saves the cost of manual cleaning, while
External (H×W×D) mm 270×845×203 315×960×230 315×1120×230
decreased effectively. During the high airflow operation, maximum 5dB(A)* ensuing a clean environment. Dimensions
Packaging(H×W×D) mm 375×943×310 430×1058×328 430×1223×328
is decreased compare with the previous generation. What's more, sleep
mode and quiet mode are also available for users to further enjoy a quiet Ⅰ
Notes:
Heating
environment. *Take AVS-12* as an example
1. "1.The nominal cooling capacity and heating capacity are based on following conditions: The above data was 2. The sound pressure level is based on following
mesaured in an anechoic chamber so that reflected sound should be taken into consideration in the field." conditions:0.8m(2.6ft.) below the unit and 1m(3.3ft.) in front of the
Cooling Operation Conditions unit. " The above data was mesaured in an anechoic chamber so that
Indoor Air Inlet Temperature:27℃ DB(80°F DB),19.0℃ WB(66°F WB) reflected sound should be taken into consideration in the field. The
Outdoor Air Inlet Temperature:35℃ DB(95°F DB) Heating Operation Conditions above noise values are measured under the condition of air supply.
Indoor Air Inlet Temperature:20℃ DB(68°F DB)
Ⅳ Ⅱ Outdoor Air Inlet Temperature:7℃ DB(44°F DB),6℃ WB(42°F WB)
Before After
Dry Frost Piping Length:7.5m(2.6ft.) Piping Lift:0m(0ft.)
5dB(A)
Ⅲ
Defrost