Optical Switch

OSX-100
Optical Switch Invisible
In all aspects, OSX-100 is designed to be invisible within your application. Its repeatability
of ± 0.005 dB makes it ideal for any automated or long term measurement application and
IL < 0.5 dB makes it a perfect fit for tight IL budgets. Each channel will maintain a high
signal-to-noise ratio thanks to the OSX’s excellent crosstalk < -80 dB.
Features

Benchtop or Rackmount
• Up to 400 outputs
• Ultra low IL < 0.5 dB
• ± 0.005 dB repeatability OSX-100 is available in 3 form factors:

• Crosstalk < -80 dB • 2U half rack benchtop up to 48 ch (rack ears available)


• Customization available
• 3U full rack up to 185 ch

• 6U full rack up to 400 ch


Product Overview
The OSX Optical Switch, OSX-100, is a customizable
benchtop/rackmount instrument ideal for high-volume Applications
manufacturing production testing. Available in single-mode or
Use with the RLM Return Loss Meter
• High-volume production
multimode, channel counts range from 1x2 up to 1x400. Extra testing OSX-100 can be connected directly to an RLM for multifiber testing. The RLM takes full
common inputs are possible by adding a 1xN or in 2B or 2C • Multiple device testing control of the switch, automating measurements while storing all references and results. If
configurations. A variety of other path routing configurations are desired, a second OSX switch can be connected to measure insertion loss, return loss, and
• Test automation
available upon request. verify mapping of multifiber connectors or complex assemblies.
• Pair with RLM for multifiber
The switch can be controlled through USB or Ethernet and the testing
front panel bulkheads fitted with FC, SC or LC connector types.

Customizable
OSX-100 switch can be customized to suit your needs at no additional cost. If you need
Compliance
multiple switches of different configurations within one chassis or a custom spliced
• UL/CSA 61010 schematic including couplers or various output connector types, talk to us and we’ll make
• IEC 61010 it happen!
• FCC Part 15 (Class A)
• EN 61326 (Class A)

95
www.santec.com
The Photonics Pioneer
Optical Switch

Ordering Scheme & Instructions


1. Configure OSX optical switch 2. Add Accessories
Opto-mechanical version 2U-Rack-Short-Ear 2U-Rack-Long-Ear
OSX-100 - - - - - - 2U Rack Short Ear 2U Rack Long Ear Filler Plate

CONFIGURATION FIBER TYPE CONNECTOR OPTIONS


1A 1xN 05 5/125 μm TYPE D touchscreen display
2A 1x2 in front of 1xN 09 9/125 μm FA FC/APC no display (leave blank)
2B ganged 50 50/125 μm FP FC/UPC
2C trailing 62 62.5/125 μm SA SC/APC
10 100/140 μm SP SC/UPC
OUTPUTS 20 200/225 μm LA LC/APC
002 2-outputs LP LC/UPC
30 300/325 μm
004 4-outputs
PM Panda PMF
2U-Connector-Plate 2U-Bezel
008 8-outputs CONNECTOR POSITION 2U Chassis Connector Plate 2U Rubber Bezels
016 16-outputs 00B front panel bulkhead
032 32-outputs XXF XXm front pigtails
400 400-outputs XXR XXm rear pigtails

Configuration Options

1A 2A 2B 2C

O O
O O 1A O
1 A 1 A 2A 1
A 2 2 3A
.. B 2
3 3
nA A 3
B ..
..
n n O
1B n-1
2B n
B 3B
.. O
nB

Position 0 Position A, 0 Position 0 Position 0


1A Configuration 2A Configuration 2B Configuration 2C Configuration
Single input, Two switchable inputs, Two inputs switched to Two inputs switched to
switched to any output switched to any output synchronized outputs any output with second
input trailing first input

97
www.santec.com
The Photonics Pioneer
OSX Optical / Electrical Specifications Mechanical / Environmental Specifications
Specification Parameter Specification
Parameter
Single-mode Multimode Unit Dimensions W x H x D (cm) 48.3 x 4.4 x 45.7
Fiber Type 9/125 Panda PM 50/125 62/125 Shipping Box Dimensions W x H x D (cm) 53 x 20 x 55
Wavelength Range (nm) 1250-1670 840-1350 Unit Weight (kg) 5
Insertion Loss (dB) ¹ , 2, 3
≤0.5 ≤1.0 ≤0.5 Total Shipment Weight (kg) 6
Backreflection (dB)¹ ≤-60 ≤-40 Operating Temperature (°C) 0 to 55
PDL (dB) 2
≤0.05 N/A N/A Storage Temperature (°C) –40 to 70
PER (dB) 1, 2
N/A ≥23 N/A Humidity (Non-Condensing) (°C) Maximum 95% RH from 0 to 40
Repeatability (dB) 2, 4
± 0.005
Crosstalk (dB) <-80
Maximum Input Power (dBm) 23

In the Box
Switch Life 10⁸ cycles
Switching Time (ms) 300
Remote Interface Ethernet / USB
Input Voltage 100 - 240 V AC, 50 - 60 Hz
OSX-100 - Optical Switch
Power Consumption (VA) 60 maximum
• OSX-100
Display Optional 5” touch screen
Notes:
• USB A to USB B cable (1.5 m)

1
Excluding Connectors
2
Standard switch size (< 80 ch), 1A and 2B configurations. • Ethernet cable (1.5 m)
3
Add 0.2 for 2C and 0.7 for 2A.
4
Sequential switching. Add + 0.02 for random.

Mechanical / Environmental Specifications


Specification
Parameter
2U half rack 3U full rack 6U full rack
Max Channel Count FC SC FC SC FC SC
Without Touchscreen
1x48 1x185 1x135 1x400
(front panel output)
Santec Regional Sales Offices
With 5” Touchscreen
1x12 1x24 1x125 1x9 5 1x360
(front or back panel output) SANTEC CORPORATION SANTEC U.S.A. CORPORATION
Unit Dimensions W x H x D (cm) 23.5 x 12 x 32.5 44.5 x 13.5 x 45 44.5 x 26.6 x 49.6 5823 Ohkusa-Nenjozaka, Komaki, 433 Hackensack Ave., Hackensack
Aichi, 485-0802, Japan NJ, 07601, USA. Toll Free: +1-800-SANTEC1 (726-8321)
Shipping Box Dimensions W x H x D (cm) 36.5 x 39 x 53 53 x 32 x 57 55 x 55 x 55 Tel: +81-568-79-3536 | Fax: +81-568-79-1718 Tel: +1-201-488-5505 | Fax: +1-201-488-7702
Unit Weight (kg) 8 14 16
Santec Europe Ltd. Santec (Shanghai) Corporation Limited
Total Shipment Weight (kg) 9 15 17 99 Park Drive, Milton Park, Abingdon, 21F Room H, Hua Du Bldg., No.838 Zhangyang Road
Oxfordshire, OX14 4RY, United Kingdom Pudong District, Shanghai, 200122, China
Operating Temperature (°C) 0 to 55 Tel: +44-20-3176-1550 Tel: +86-21-5836-1261 | Fax: +86-21-5836-1263
Storage Temperature (°C) -40 to 70
2022© SANTEC CORPORATION Santec reserves the right to make changes in equipment design, components or specifications without notice.
Humidity (Non-Condensing) Maximum 95% RH from 0 to 40C OSX-100-C-E/Ver.1.1 CODE-202303-MB-KT-CPY