0% found this document useful (0 votes)
37 views15 pages

Release Notes

Uploaded by

xeyeci7054
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
37 views15 pages

Release Notes

Uploaded by

xeyeci7054
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 15

MIL-STD-1553

Xenomai2 BSP

Release
Notes

Version 14.1.3
July, 2022

www.aim-online.com
MIL-STD-1553

Xenomai2 BSP

Release
Notes

Version 14.1.3
July, 2022

AIM NO. 60-11935-32-14.1.3

MIL-STD-1553 - V14.1.3 I
AIM – Gesellschaft für angewandte Informatik und Mikroelektronik mbH

AIM GmbH AIM GmbH – Munich Sales Office


Sasbacher Str. 2 Terofalstr. 23a
D-79111 Freiburg / Germany D-80689 München / Germany
Phone +49 (0)761 4 52 29-0 Phone +49 (0)89 70 92 92-92
Fax +49 (0)761 4 52 29-33 Fax +49 (0)89 70 92 92-94
[email protected] [email protected]

AIM UK Office AIM USA LLC


Cressex Enterprise Centre, Lincoln Rd. Seven Neshaminy Interplex
High Wycombe, Bucks. HP12 3RB / UK Suite 211 Trevose, PA 19053
Phone +44 (0)1494-446844 Phone 267-982-2600
Fax +44 (0)1494-449324 Fax 215-645-1580
[email protected] [email protected]

© AIM GmbH 2022

Notice: The information that is provided in this document is believed to be accurate. No responsibility
is assumed by AIM GmbH for its use. No license or rights are granted by implication in connection
therewith. Specifications are subject to change without notice.

II MIL-STD-1553 - V14.1.3
TABLE OF CONTENTS

TABLE OF CONTENTS
1 Important Notes.......................................................................................................................... 1

2 Known Issues ............................................................................................................................. 2

3 Version and Change History ..................................................................................................... 3


3.1 BSP 14.1.3 - (2022.07: Xenomai2)................................................................................... 3
3.2 BSP 14.1.2 - (2022.06: Windows,Linux,LabViewRT)........................................................ 3
3.3 BSP 14.1.1 - (2022.03: Windows,Linux) ........................................................................... 3
3.4 BSP 14.1.0 - (2022.02: Windows,Linux) ........................................................................... 4
3.5 BSP 14.0.0 - (2021.12: LabViewRT)................................................................................. 5

4 System Requirements................................................................................................................ 6

5 Operating System Compatibility............................................................................................... 7

List of Abbreviations.......................................................................................................................... I

MIL-STD-1553 - V14.1.3 III


TABLE OF CONTENTS

IV MIL-STD-1553 - V14.1.3
1 IMPORTANT NOTES

1 Important Notes

• None.

MIL-STD-1553 - V14.1.3 1
2 KNOWN ISSUES

2 Known Issues

• Interrupt flush is not implemented. It can happen that an old event is still pending when an appli-
cation is started and calls ApiInstIntHandler.

• APE1553-1/2-DS Milscope not implemented.

• DMA memory read is not implemented.

• See Getting Started Manual for further Xenomai2 design limitations.

2 MIL-STD-1553 - V14.1.3
3 VERSION AND CHANGE HISTORY

3 Version and Change History

3.1 BSP 14.1.3 - (2022.07: Xenomai2)

Task

• BSPMIL-727 - Xenomai2: Update BSP to current component versions

Bug

• None

Incompatibilitiy Issues with Previous Versions

• None

3.2 BSP 14.1.2 - (2022.06: Windows,Linux,LabViewRT)

Task

• BSPMIL-683 - BSP Setup: use new Eula document

• BSPMIL-687 - ANET1553-2 Improve traffic override handling for multi channel boards

• BSPMIL-697 - Windows,LabViewRT: Improved 1553 VIs (see VIP installer for details)

Bug

• None

Incompatibilitiy Issues with Previous Versions

• None

3.3 BSP 14.1.1 - (2022.03: Windows,Linux)

Task

• BSPMIL-672 - Linux: Remove unused files from BSP

• BSPMIL-673 - LabViewRT: Set IPK architecture field to x64-PXI as ARM targets are not supported

• BSPMIL-675 - Linux: Add Aim Network Server (ANS1553) to BSP

MIL-STD-1553 - V14.1.3 3
3 VERSION AND CHANGE HISTORY

Bug

• BSPMIL-679 - ASC1553: ApiCmdSysGetBoardInfo returns invalid values for


TY_BOARD_INFO_HAS_EXTERNAL_IRIG and TY_BOARD_INFO_HAS_EXTERNAL_TRIGGER

Incompatibilitiy Issues with Previous Versions

• None

3.4 BSP 14.1.0 - (2022.02: Windows,Linux)

Task

• BSPMIL-426 - Windows: SmartCon update window hangs after shutdown is postponed by p key

• BSPMIL-531 - ANET WebConfig updated reboot note

• BSPMIL-580 - Linux: Support Ubuntu 20.04 Kernels

• BSPMIL-597 - Linux: net-detection-tool not working on systems that do not have QT4

• BSPMIL-665 - Linux: Add license statements to BSP source folders

• BSPMIL-666 - Windows: Add EULA to BSP and installer

• BSPMIL-667 - New functions ApiCmdBCTrafficOverrideControl and ApiCmdBCTrafficOverrideGet

• BSPMIL-668 - APE/AMCX/AXC/ACE/APXX/ACXX1553 Added acyclic retry if 1553 bus is busy

• BSPMIL-669 - AME1553-1/AP Added acyclic retry if 1553 bus is busy

• BSPMIL-670 - ASC1553-1 Added acyclic retry if 1553 bus is busy

• BSPMIL-671 - AMEE1553-2 Added acyclic retry if 1553 bus is busy

Bug

• BSPMIL-25 - ApiCmdRTSAMsgRead returns invalid status queue entry on qsize gt 1

• BSPMIL-565 - ASC1553: Sporadic no response error due to BSPMIL-515 fix

• BSPMIL-579 - HS BSP sample does not allow sample 62 (EfEfaEfexSwitchSample) for non full
function boards

• BSPMIL-581 - ASC1553: ApiCmdSetIrigTime/ ApiCmdSetIrigStatus might take longer than 3 sec-


onds

• BSPMIL-582 - AME1553: ApiCmdSetIrigTime/ ApiCmdSetIrigStatus might take longer than 3 sec-


onds

• BSPMIL-583 - AMEE1553: ApiCmdSetIrigTime/ ApiCmdSetIrigStatus might take longer than 3


seconds

• BSPMIL-589 - Linux: Make sample objects files write able after install.sh was called as root

4 MIL-STD-1553 - V14.1.3
3 VERSION AND CHANGE HISTORY

Incompatibilitiy Issues with Previous Versions

• BSPMIL-467 - Windows: New 1553 LabView VI interface bundled as VIP package

3.5 BSP 14.0.0 - (2021.12: LabViewRT)

Task

• BSPMIL-595 - LabViewRT: Added support for Linux targets

• BSPMIL-134 - ApiCmdCalXmtCon set primary and secondary amplitude for boards with a packed
amplitude

• BSPMIL-93 - Remove unsupported AyI, PC104 and PMC code and files from projects

Bug

• None

Incompatibilitiy Issues with Previous Versions

• BSPMIL-467 - LabViewRT: New 1553 LabView VI interface bundled as VIP package

• BSPMIL-594 - LabViewRT: Removed support for Phar Lap targets

MIL-STD-1553 - V14.1.3 5
4 SYSTEM REQUIREMENTS

4 System Requirements

• Personal Computer (PC) with running Linux Operating System (OS) and Xenomai2 installed. (See
Section 5 "Operating System Compatibility")

• AIM hardware device installed in local PC. Following devices are supported with this Board Soft-
ware Package (BSP):

– AMCX1553 (AIM PMC AyE Architecture)


– AMCE1553 (AIM PMC AyE Embedded Architecture)
– AXC1553 (AIM XMC AyE Architecture)
– AXE1553 (AIM XMC AyE Embedded Architecture)
– APE1553 (AIM PCIe Architecture)
– APXX1553 (AIM PCI Architecture)
– ACXX1553 (AIM PXI Architecture)
– ACE1553 (AIM PXIe Architecture)
– ACP1553 (AMCX1553 on ACP carrier)
– ACC1553-3U (AMCX1553 on ACC-3U carrier)
– ACC1553-6U (AMCX1553 on ACC-6U carrier)

6 MIL-STD-1553 - V14.1.3
5 OPERATING SYSTEM COMPATIBILITY

5 Operating System Compatibility

This BSP was tested with the following Linux and Xenomai versions. The software may also run on other
versions, not listed here.

Debian 8

• Linux Kernel 3.18.20

• Xenomai 2.6.5

MIL-STD-1553 - V14.1.3 7
5 OPERATING SYSTEM COMPATIBILITY

8 MIL-STD-1553 - V14.1.3
List of Abbreviations

List of Abbreviations

BSP Board Software Package

OS Operating System

PC Personal Computer

MIL-STD-1553 - V14.1.3 I

You might also like