Diff Failing Failed Disks
Diff Failing Failed Disks
=====================================================
A failed disk will only show an increase in the number of transport errors.
=============================================================================
#
Now that you�re sure that the disk has failed, you can skip the metadevice related
operations � metadetach and metaclear � that must be done prior to replacing a
failing disk. In fact, SVM will not allow you to do metadetach and metaclear on a
failed disk.
# metadetach d0 d20
metadetach: solaris_1: d0: attempt an operation on a submirror that has erred
components
#
You will still need to delete the state database replicas. But that�s one command
compared to the dozen or so metadetaches and metaclears that you need to do for a
failing disk.
Read these articles for instructions on How To Replace A Failed SVM Disk and How To
Replace A Failing SVM Disk.