A failing disk is still visible in the format command.

=====================================================

AVAILABLE DISK SELECTIONS:


0. c1t0d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
/pci@780/pci@0/pci@9/scsi@0/sd@0,0
1. c1t1d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
/pci@780/pci@0/pci@9/scsi@0/sd@1,0
2. c1t2d0 <SEAGATE-ST973402SSUN72G-0400-68.37GB>
/pci@780/pci@0/pci@9/scsi@0/sd@2,0
3. c1t3d0 <SEAGATE-ST973402SSUN72G-0400-68.37GB>
/pci@780/pci@0/pci@9/scsi@0/sd@3,0
Specify disk (enter its number):

A failed disk is marked �drive not available�.


-=============================================

AVAILABLE DISK SELECTIONS:


0. c1t0d0 <SUN72G cyl 14087 alt 2 hd 24 sec 424>
/pci@1f,700000/scsi@2/sd@0,0
1. c1t1d0 <drive not available>
/pci@1f,700000/scsi@2/sd@1,0
2. c1t2d0 <SUN72G cyl 14087 alt 2 hd 24 sec 424>
/pci@1f,700000/scsi@2/sd@2,0
3. c1t3d0 <SUN72G cyl 14087 alt 2 hd 24 sec 424>
/pci@1f,700000/scsi@2/sd@3,0
Specify disk (enter its number):

A failing disk will show read or write errors in /var/adm/messages.


====================================================================

Jan 1 03:11:19 solaris_1 scsi: [ID 107833 kern.warning] WARNING:


/pci@1c,600000/scsi@2/sd@1,0 (sd1):
Jan 1 03:11:19 solaris_1 Error for Command: write(10) Error Level:
Retryable
Jan 1 03:11:19 solaris_1 scsi: [ID 107833 kern.notice] Requested Block:
37782714 Error Block: 37782714
Jan 1 03:11:19 solaris_1 scsi: [ID 107833 kern.notice] Vendor: SEAGATE
Serial Number: 0344A6E4EG
Jan 1 03:11:19 solaris_1 scsi: [ID 107833 kern.notice] Sense Key: Unit
Attention
Jan 1 03:11:19 solaris_1 scsi: [ID 107833 kern.notice] ASC: 0x29 (bus device
reset message occurred), ASCQ: 0x3, FRU: 0x4

A failed disk just won�t respond:


=================================

Jul 19 11:21:59 solaris_1 scsi: [ID 107833 kern.warning] WARNING:


/pci@1f,700000/scsi@2/sd@1,0 (sd2):
Jul 19 11:21:59 solaris_1 disk not responding to selection
Jul 19 11:22:01 solaris_1 scsi: [ID 107833 kern.warning] WARNING:
/pci@1f,700000/scsi@2/sd@1,0 (sd2):
Jul 19 11:22:01 solaris_1 disk not responding to selection
A failing disk will show an increase in the number of hard and transport errors
over time.
===================================================================================
=======

# iostat -En c1t1d0

c1t1d0 Soft Errors: 0 Hard Errors: 28473 Transport Errors: 107662


Vendor: SEAGATE Product: ST336607LSUN36G Revision: 0307 Serial No: 0344A6E4EG
Size: 36.42GB <36418595328 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 28473 Recoverable: 0
Illegal Request: 0 Predictive Failure Analysis: 0
#

A failed disk will only show an increase in the number of transport errors.
=============================================================================

# iostat -En c1t1d0


c1t1d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 18
Vendor: FUJITSU Product: MAW3073NCSUN72G Revision: 1703 Serial No: 0708B0KP9L
Size: 73.40GB <73400057856 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0
Illegal Request: 0 Predictive Failure Analysis: 0

#
Now that you�re sure that the disk has failed, you can skip the metadevice related
operations � metadetach and metaclear � that must be done prior to replacing a
failing disk. In fact, SVM will not allow you to do metadetach and metaclear on a
failed disk.

# metadetach d0 d20
metadetach: solaris_1: d0: attempt an operation on a submirror that has erred
components
#
You will still need to delete the state database replicas. But that�s one command
compared to the dozen or so metadetaches and metaclears that you need to do for a
failing disk.

Read these articles for instructions on How To Replace A Failed SVM Disk and How To
Replace A Failing SVM Disk.