0% found this document useful (0 votes)
135 views49 pages

Pre-Compliance-Testing-Facility Haryana

Uploaded by

Manohar Tm
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
135 views49 pages

Pre-Compliance-Testing-Facility Haryana

Uploaded by

Manohar Tm
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 49

About Us

AA EMT Labs (AA Electro Magnetic Test,


Private Limited), is an independent testing
and international approval laboratory
ideally located in Udyog Vihar, Gurugram,
Delhi-NCR, which is one of the largest
engineering development regions. AA EMT
Labs is Accredited as per ISO 17025:2017 by
NABL , BIS, TEC, ILAC, FDA ,A2LA for FCC
(USA), ISED (Canada), CE(Europe) , VCCI
(Japan), RCM (Australia) and BSMI and
NCC(Taiwan) We provide One Stop Solution
for Testing & Certification. Automotive
standard for Testing Certifications in New
Delhi, India. Also, AA EMT provides
international approval services.
Quality
WE BELIEVE IN
DELIVERING THE
HIGHEST
QUALITY OF
SERVICES TO
OUR CLIENTS.
Credibility
WE AIM TO CREATE A
‘ONE-STOP
DESTINATION’ THAT CREDIBILITY
COVERS ALL YOUR
TESTING AND
CERTIFICATION
REQUIREMENTS.
Safety
We adhere to the best

SAFETY testing practices in


complying with local,
national and
international
regulations
•First Lab In India Has 6 Chambers Includes 2

1
Semi Anechoic Chamber, 2 Pre-compliance
Semi Anechoic Chamber For Product
Development , 2 Shielding Chamber

Why •An ISO 9001:2015,

2 •ISO 17025:2017

Choose Accredited Laboratory

•More Than 3 Decades Experienced Field

Us 3 EMC Engineers Owned And Run The


Organization

•First Lab In India which Has FR1 Testing for Base

4
Station & Microwave etc.
•First Lab In India Has The One Stop Solution For
TEC & BIS Requirements
ACCREDITATION
&
INTERNATIONAL
APPROVALS
ACCREDITATION CERTIFICATES- NABL & A2LA
CAB DESIGNATION - TEC
CAB REORGANIZATION – BIS ( CRS & MEDICAL)
FCC SCOPES – WIRELESS /CELLULAR
VCCI – JAPAN CERTIFICATION – CONDUCTED
EMISSION
VCCI – JAPAN CERTIFICATION – RADIATED
EMISSION
INTERNATIONAL TELECOMMUNICATION UNION (ITU)
RECOGNIZED TEST LAB ITU CONFORMITY AND
INTEROPERABILITY
ISED – CANADA – WIRELESS TESTING
(HTTPS://ISED-ISDE.CANADA.CA/SITE/MUTUAL-RECOGNITION-
AGREEMENTS/EN/WIRELESS-DEVICE-TESTING-LABORATORIES)
AA ELECTRO MAGNETIC TEST (AA EMT) FOR YOU …..
About
EMI/EMC
1. AA EMT accredited as per ISO 17025:2017 by NABL – TC
8597 (ILAC-India) EMI/
2. AA EMT accredited as per ISO 17025:2017 by A2LA –
5593.01 (ILAC-Global) EMC
3. AA EMT recognized by FCC – Facility No. 137777 (USA)
4. AA EMT recognized by ISED – Facility No. 26046 (Canada)
5. AA EMT recognized BIS – India – 816586 (India)
6. AAEMT Designated by TEC – DoT – IND063 (India)
7. AA EMT recognized& Site validated by VCCI– Facility
No.4053 (Japan)
8. AA EMT recognized by FDA / ASCA through A2LA – 5503.01
(USA)
9. AA EMT Empanelled by RCM/NZ through A2LA – 5503.01
(AUS / NZ)
10. AAEMT Empanelled as per CE & UKCA requirements for LVD,
EMC, Radio Directives
FACILITY IN EMC IN
GROUP WISE
Commercial Products – Telecom, Electronics,
Lighting etc.,

CISPR Series ( all the Emission Standards)


Telecom Standards ( ETSI EN 300 386, ETSI EN 301 893 etc.,)
Indian EMC Standards (IS 6873, IS 14700 Series, TEC Standards)
Industry Standards IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3 & IEC 61000-6-4
FCC Part 15 B ,FCC 18
Product Standards IEC 61547, IEC 61326-2-6, EN 50121 etc.,
ETSI EN – EMC standards for CE Marking & BS EN Standards for UKCA requirements
Automobile Products EMC Tests

AA EMT CAN DO ALL THE ESA AUTOMOBILES PRODUCTS AS FOLLOWS


CISPR 25, CISPR 12, AIS 004-3, AIS 148 STANDARDS
CONDUCTED EMISSION TESTS
RADIATED EMISSION TESTS
BULK CURRENT INJECTION TESTS
ELECTRIC PULSES AS PER ISO STANDARDS
ESD TEST
Military Products

AA EMT can do all the Single-phase products for MIL requirements


as per MIL 461 C,D,E,F & G the following tests,
CE 101, CE 102 & CE 106
RE 101, RE 102 & RE 103
CS 114 -1,2,3,4 & 5
CS 118 , HESD
Medical Products EMC Tests

AA EMT is only Indian Lab got approval by FDA / ASCA


IEC 60601-1-2 standard
IEC 61326-2 Series for IVR medical Devices
IEC 60601-2-21 Edition 2.1 2016-04
IEC 60601-2-20 Edition 2.1 2016-04
IEC 60601-2-2 Edition 6.0 2017-03
IEC 60601-2-25 Edition 2.0 2011-10
IEC 60601-2-27 Edition 3.0 2011-03
BS EN 60601-1; IEC 60601
IEC 60601-2-21/ IS 13450: PART 2: SEC 21: 2018
IEC 60601-2-20/IS 13450: PART 2: SEC 20: 2018
IEC 60601-2-2/ IS 13450: PART 2: SEC 2: 2019
IEC 60601-2-25/ IS 13450: PART2 : SEC 25: 2018
IEC 60601-2-27/ IS 13450: PART2: SEC 27: 2018
ISO 80601-2-69
ISO 80601-2-26/ IS 13450: PART 2: SEC 26: 2018
MEDICAL ELECTRICAL EQUIPMENT- PART 2-22: PARTICULAR REQUIREMENTS FOR BASIC
SAFETY AND ESSENTIAL PERFORMANCE OF SURGICAL, COSMETIC, THERAPEUTIC AND
DIAGNOSTIC LASER EQUIPMENT
IEC 80601-2-49/ IS 13450-2-49
ISO 80601-2-61
IEC 60601-2-47
IEC 60601-1-11
IEC 62304: 2006
AA EMT designated by TEC for all the EMC parameter
TEC/EMC/SD/DD/ 005-Oct 16 including Base Station / Active Antenna’s
ITU-T K.21, 22, 44, & ITU-T K.45 standards for Telecom Surge, Over Voltage
Protection
ETSI EN 300 386 series , ETSI EN 301 489 series
AA EMT is the prime Laboratory for Internet of Things products in last one
year we did 50+ and counts IoT Products
FACILITY IN WIRELESS TESTING – FOR EU

AA EMT can do the wide range of wireless testing


ETSI EN 300 328 (2.4GHz) for BLE / BT / WiFi / Zig Bee Testing
ETSI EN 301 893 (5GHz) for WiFi Access Point
ETSI EN 302 502 (5.8GHz) for RLAN / Access Point
ETSI EN 300 220 / 300 330 / 300 440 for SRD
Technology can be tested:
BT / BLE / WiFi -2.4GHz / WiFi -5GHz / LoRa / SigFox / RFID / NFC / RF Mesh / Ant / Ant
+ / Z Wave etc.,
Facility in Wireless Testing – for FCC / ISED

AA EMT can do the wide range of wireless testing as per FCC recognition.
FCC Part 15 C – 15.247 (2.4GHz)
FCC Part 15 C – 15.209 (SRD)
FCC Part 15 C – 15.407 (5GHz)
Part 15D - Unlicensed Personal Communications Service Devices FCC Part 15 E
FCC Part 15 E -U-NII without DFS Intentional Radiators
FCC Part 15 F - Ultra-Wideband Operation (UWB)
FCC Part 15 G - BPL Intentional Radiators
FCC Part 15 H- White Space Devices
AA EMT can do wide range of Cellular Testing
GSM - 3GPP TS 51 010-1 or EN 301 511 (GSM/GPRS/EDGE)
WCDMA / /HSPA - 3GPP TS 34.121-1 or EN 301 908-2 (UMTS)
CDMA - EN 301 908-04 (CDMA)
LTE - 3GPP TS 36.521-1 or EN 301 908-13 (LTE/LTE-A)
Base Station Antenna / Active Antenna System - 3GPP TS 37.145-1, ETSI EN 137.145-1
Multi-Standard Radio (MSR) / Base Station (BS) - 3GPP TS 37.141: 2016
Technology Covered :
2G / 3G / 4G / / BTS / AAS / NB-IoT
AA EMT Has The Complete Facility And Recognized By FCC
Commercial Mobile Services (FCC Licensed Radio Service Equipment)
Public Mobile Services - FCC Parts 22 (Cellular),
Personal Communications Services - FCC Part 24,
Satellite Communications - FCC Part 25 (Below 3 GHz),
Miscellaneous Wireless Communications Services – FCC Part 27
AA EMT done more than 10+ Projects in last one year.
Technology Covered :
FCC 22 / FCC 24 / FCC 27 / FCC 90
FDA / ASCA PROGRAM TESTING FACILITY

Testing Activities performed under the scope of the U.S FDA ASCA Pilot Program Specifications:
Basic Safety and Essential Performance of Medical Electrical Equipment, Medical Electrical Systems, and
Laboratory Medical Equipment – Standards Specific Information for the Accreditation Scheme for
Conformity Assessment (ASCA) Pilot Program published on September 25th, 2020, and in accordance with all
requirements of A2LA R256 Specific Requirements- FDA ASCA Program1
Standards
IEC 60601-2-21 Edition 2.1 2016-04
IEC 60601-2-20 Edition 2.1 2016-04
IEC 60601-2-2 Edition 6.0 2017-03
IEC 60601-2-25 Edition 2.0 2011-10
IEC 60601-2-27 Edition 3.0 2011-03
5G Facility in Cellular Testing – EU

India’s First & Only Accredited Test Lab for


5G New Radio
3GPP 38.141-1 / ETSI EN 138.141-1 for Base
Station – FR 1 Frequency Test Lab
3GPP 38.104 / ETSI EN 138.141-1 for
Standalone Test Lab – BBU / RRU
3GPP 38.521 / ETSI EN 138.521 for User
Equipment – MIMO / SISO, IoT Products
Technology Covered :
1. 5G – FR 1 Frequency
2. < 600MHz Bandwidth devices
3. < 100MHz Bandwidth devices
FACILITY IN ELECTRICAL SAFETY TESTING UNDER BIS / TEC

Information technology equipment – Safety – Part 1: General requirements - IEC 60950-1


Audio/video, information and communication technology equipment Part 1:Safety
requirements - BS EN 623681-1; IEC 62368
Uninterruptible power systems (UPS) - Part 1 - BS EN 62040-1; IEC 62040-1
Audio, video and similar electronic apparatus – Safety requirement - BS EN 60065; IEC 60065
IS 16102-1 Electrical Safety for LED Bulbs
IS 15888 – Electrical Safety for Control Gears
IS 16333 – Mobile Language test for Indian Languages
BS EN 61010-1; IEC 61010-1
Facility in Electrical Safety Testing for Medical devices

Medical electrical equipment - Part 1: General requirements for basic safety and essential performance - BS EN 60601-1; IEC 60601-1
requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements - BS EN 61010-1;IEC 61010-1
Human Safety RF Exposure - 1 Hz to 300 GHz - IEC 62311; BS EN62311
Medical electrical equipment - Part 2-21: Particular requirements for the basic safety and essential performance of infant radiant warmers
IEC 60601-2-21/ IS 13450: Part 2 : Sec 21 : 2018
Medical Electrical Equipment Part 2 Particular Requirements for the Basic Safety and Essential Performance Section 20 Infant Transport Incubator
IEC 60601-2-20/ IS 13450: Part 2: Sec 20 : 2018
Medical electrical equipment – Part 2-2: Particular requirements for the basic safety and essential performance of high frequency Surgical equipment
and high frequency surgical accessories IEC 60601-2-2/ IS 13450: Part 2: Sec 2 : 2019
Medical electrical equipment – Part 2-25: Particular requirements for the basic safety and essential performance of electrocardiographs - IEC 60601-
2-25 / IS 13450: Part 2 : Sec 25 : 2018
Medical Electrical Equipment Part 2 Particular Requirements for the Basic Safety and Essential Performance Section 27 Electrocardiographic
Monitoring Equipment - IEC 60601-2-27 / IS 13450: Part 2 : Sec 27: 2018
Medical electrical equipment - Part 2-69: Particular Requirements for the basic safety and essential performance of oxygen concentrator equipment
ISO 80601-2-69
DRY HEAT
DAMP HEAT
Flammability Tests
COLD TEST
Vibration
THERMAL CYCLIC TEST Shock
THERMAL SHOCK TEST Bump
SALT SPRAY / SALT MIST Humidity Test
DROP / FALL / TOPPLE NEMA 250
DUST / SAND TEST Altitude up to 40,000 ft.
IP 1X.2X, 3X, 4X, 5X,6X & X1, X2, X3, X4, X5, Impact Test.
X6, X7 AS PER IEC 60529 / IEC 60950-22
IK Testing up to 50 J
DRY HEAT
DAMP HEAT
Flammability Tests
COLD TEST
Vibration
THERMAL CYCLIC TEST Shock
THERMAL SHOCK TEST Bump
SALT SPRAY / SALT MIST Humidity Test
DROP / FALL / TOPPLE NEMA 250
DUST / SAND TEST Altitude up to 40,000 ft.
IP 1X.2X, 3X, 4X, 5X,6X & X1, X2, X3, X4, X5, Impact Test.
X6, X7 AS PER IEC 60529 / IEC 60950-22
IK Testing up to 50 J
FACILITY AVAILABLE FOR ENVIRONMENTAL – INDIAN MILITARY –
JSS 55555 STANDARD

DRY HEAT
DAMP HEAT
Flammability Tests
COLD TEST
Vibration
THERMAL CYCLIC TEST Shock
THERMAL SHOCK TEST Bump
SALT SPRAY / SALT MIST Humidity Test
DROP / FALL / TOPPLE NEMA 250
DUST / SAND TEST Altitude up to 40,000 ft.
IP 1X.2X, 3X, 4X, 5X,6X & X1, X2, X3, X4, X5, Impact Test.
X6, X7 AS PER IEC 60529 / IEC 60950-22
IK Testing up to 50 J
DRY HEAT
DAMP HEAT
Flammability Tests
COLD TEST
Vibration
THERMAL CYCLIC TEST Shock
THERMAL SHOCK TEST Bump
SALT SPRAY / SALT MIST Humidity Test
DROP / FALL / TOPPLE NEMA 250
DUST / SAND TEST Altitude up to 40,000 ft.
IP 1X.2X, 3X, 4X, 5X,6X & X1, X2, X3, X4, X5, Impact Test.
X6, X7 AS PER IEC 60529 / IEC 60950-22
IK Testing up to 50 J
AA EMT OFFERS PRE – COMPLIANCE TESTING
FACILITY IN THE FOLLOWING TESTING
EMC COMPLIANCE TESTING WITH COMPLETE RAKE
FROM WURTH ELECTRONICS DESIGN KIT
RF ANTENNA DESIGN TESTING INCLUDE 5 G READY
MIMO ANTENNA WITH SMITH CHART EVALUATION
SAFETY – FLAMMABILITY, TRACKING, SCRATCHING,
HI-POT, THERMAL TEST ETC.,
AA EMT offers in future
Over the Air Testing for Cellular LTE as
per PTCRB, GCA, GSMA Requirements
Future Expansion plan of 2nd Lab in
Chennai or Hosur (Bangalore border)
IPV6 Ready logo Interface /
Interoperability Test Lab
FR 2 Expansion Plan in Gurgaon on
demand.
AA EMT is only one lab have multiple SAC (Semi Anechoic Chamber) in Single Roof
Only Accredited Test Lab for VCCI Japan
Only Selected / BIS Recognised Test Laboratory for Indian EMC Standards
Only BIS Selected / Recognised Test Laboratory for Medical Devices
Only TEC CAB has wide range of Wireless & Cellular Standards
First & Only Accredited Test Laboratory for 5G Base Station / Multi Standard Radio Test
Laboratory by NABL & A2LA
First & Only Accredited Test Laboratory for 5G User Equipment Test Laboratory by NABL
Maximum (Around 80%) product certified by TEC in total certification issued as on Date.
One Stop solution for the following
Product Safety as per IEC/IS 62368-1 : 2018
Product Safety as per IEC 60950-1 / IS 13252-1
Product Language Tests as per IS 16333-3
Complete EMC Compliance Standard as per IS / FCC/ ISED/ IEC / CISPR / ETSI EN / BS EN /
AS-NZ Standards
Environmental Testing as per IEC / IS / QM 333 / JSS 55555 / MIL 810 / ETSI EN 300 019
Standards
Cellular Testing from GSM/WCDMA/LTE/ LTE-A / CDMA & 5 G- NR
Wireless Test Facility for NRF,RFID, Sigfox, LoRa, RF Mesh, Z Wave, Ant +, Zigbee, BT,BLE,
WIFI
Meet Our Mr. Jackie Deng Mr. Jay Gandhi
( Director ) ( President )

Team

Dr. Lenin Raja

( Vice President
Engineering )
CONTACT US:
Website : www.aaemtlabs.com
Email : [email protected],
[email protected],
[email protected]
Phone No : +91-8929173839
+91 - 8929174772
Address : Plot No 174, Udyog Vihar -
Phase 4,Sector 18, Gurugram,
Haryana.

You might also like