Big Calculator
Big Calculator
Contact
[email protected]
Area
Annular Area Single String
Annular Area Multiple Strings
Area Of A Circle
Area Between Two Circles
Cross-Sectional Area ( Seal Assy. Inserted )
Circle
Circumference Of A Circle
Diameter Of A Circle
Radius Of A Circle
Constants
Thermal Coefficients
Fresh Water Facts
Conversions
Barrel To Cu./ Ft.
Cubic Foot To Barrel
Cubic Foot To Cubic Inches
Gradient
Specific Gravity To Gradient
API Gravity To Gradient
Density lb./ ft.3 To Gradient
Measurement
Decimal To Fraction
Fraction To Decimal
Inche To Foot Converion
Specific Gravity
Fluid Weight lb./ gal. To Specific Gravity
API Gravity To Specific Gravity
Density lb./ ft.3 To Specific Gravity
Fluid
Fluid Weight To Gradient
Fluid Velocity
Fluid Weigh Up
Fluid Cut Back
KCL
CaCl2 Weigh Up ( Using 94-97% CaCl2 )
CaBr2 & ZnBr2 Weigh Up ( Using 94-97% CaCl2 )
CaBr2 & ZnBr2 Weigh Up ( Using 95% CaBr2 )
Gravel Pack
Yield & Fluid Wt. Of Slurry After Adding Sand
Wash Pipe / Screen Ratio ( Optimum Is 80% )
Minimum Clearance For Gravel Pack Completions
Drift Plate Tolerance
Leaks
Locating
Packer
Velocity Of Fluid Across Packer Elements
Piston Effects
Piston Force Exerted
Piston Pressure Created
Pressure
Hydrostatic Pressure
Fluid Weight Required For BHP @ Depth
Maximum Allowable Pump Pressure
Pumps
Triplex Pump Output Barrels Per Stroke
SCSSV
Maximum Leakage Rate of SCSSV and Plugs
Maximum Fail-Closed Setting Depth
Specific Gravity To Gradient
Recommended Control Line Hold Open Pressure
Control Line Fluid Volume
Shear Pins
To Calculate Pin Shear Force
Pressure Required To Shear Pins
Slickline
Area Of A Slickline
Tool String Balance Weight Neglecting Friction
Stem Weight
Stem Length Needed Neglecting Friction
Minimum Bending Diameter Of Wire
Wire Weight
Wire Weight Balance Depth
Wire Strength ( approximate / standard plow steel )
Spool Capacity
Tubing Fill-Up Rule Of Thumb
Hydrostatic Rule Of Thumb
Rule Of Thumb For WireLine Fall-Back
Area Of Pipe
Temperature
Average Pipe Temperature
Change In pipe length ( inches ) due to temperature change
Change In Average Tubing Temperature, Injecting / Acidizing Condition
Change In Average Tubing Temperature, Flowing Condition
Converting Temperature Change To Length Change
Tubing
I.D. Calculated
Joint Yield Strength Of EUE Tubing
Cross-Sectional Area Of Pipe
Tubing Weight In Air
Tubing Weight With Upsets & Coupling
Tubing Weight In Fluid
Buoyancy Factor
Buoyancy Factor Bull Plugged In Fluid ( lb./ ft. )
Tubing Capacity
Tubing Fill-Up Factors
Tubing Fill-Up
Tubing Displacement
Pipe Stretch
Slack-Off Data
Slack-Off Factor
Determining Pipe Pull
Free Pipe Depth
Volume
Rectangular Volume / Capacity
Cylindrical Volume / Capacity
Spherical Volume / Capacity
Pipe / Hose Volume
Enter Necessary Information In Highlighted A
FOR REFERENCE ONLY
Annular Area Single String
( ID2 x .7854 ) - ( OD2 x .7854 ) = Annular Area
Casing ID 8.291 Area In2
Tubing OD 2.875 47.497
Casing ID 8.291
Tubing OD #1 2.375
Tubing OD #2 2.375 Area In2
Tubing OD #3 45.129
Tubing OD #4
ormation In Highlighted Areas
EFERENCE ONLY
Enter Necessary Information In Highlighted A
FOR REFERENCE ONLY
Area Of A Circle
3.1416 x Radius2 = Area
Radius 6.000 Area 113.098
Diameter2 x .7854 = Area
Diameter 3.000 Area 7.069
0.094
e Less Than 60 FPS To Avoid Tool Erosion.
56.778
sents The Minimum Needed To Safely Pump
The Job.
1.316
adial Clearance 0.085
t Completion Clearance
0.171
0.085
Enter Necessary Information In Highlighted A
FOR REFERENCE ONLY
To Locate Leak ( Different Wt. Fluids Tbg. / Csg. )
Conversion Data
1 Barrel = 5.61458 Cu. / Ft.
1 Gallon = 0.133681 Cu. / Ft.
Tool String Balance Weight Neglecting Friction Length 13800 Total Weight
( OD2 x .7854 ) x Pressure = Tool Sting Weight ( balanced ) 311.48
Wire Size 0.092 Tool String Weight
Pressure 1500 9.97
Wire Weight Balance Depth
Stem Weight .2945 x Pressure = Depth
( OD2 x 8 ) / 3 = Lbs./ Ft. Pressure 1500 Depth
OD 1.5 Lb./ Ft. 6.00 441.75
OD x OD x 2.667 = Lbs./ Ft.
OD 1.25 Lb./ Ft. 4.17 Wire Strength ( approximate / standard plow steel )
( OD2 x .7854 ) x 280000 = Approximate Maximum Breaking Strength
Stem Length Needed Neglecting Friction Wire Size 0.092
Stem Weight Needed / Stem Weight lb./ ft. Approximate Max. Strength 1861
Weight Needed 10 Length Needed Ft. (( OD2 x .7854 ) x 280000)*.85 = Approximate Minimum Breaking Strength
Stem Weight lb./ ft. 6 1.667 Wire Size 0.092
Approximate Min. Strength 1582
Minimum Bending Diameter Of Wire
Spool Capacity
NOTE: Larger sheaves, wheels or pulleys could extend cable / wire life. Reference Only ( Assumes Wire Is Perfectly Spooled
Stranded, Braided or Conductor Cables (Drum Width x ( Flange OD - Drum OD ) / 2 ) x ( Drum OD + ( Flange OD -
Diameter of Cable X 64 = Minimum Bending Diameter In Inches Drum OD ) / 2 ) / (( 4 x ( Wire OD )))
Cable Diameter Minimum Diameter In. Enter All Information In Inches
1 /2 32 Drum Width Between Flanges 31
3 /4 48 Flange OD 29
6 /8 48 Drum OD 14
3 /16 12 Wire OD ( Decimal ) 0.25
6 /32 12 Spool Capacity Ft. 19,995
12 /64 12
Slickline Wire ( Piano, Solid )
Diameter of Wire X 120 = Minimum Bending Diameter In Inches
Wire Size Minimum Diameter In.
0.092 11.04
as
Tubing Length x Tubing Wt./ Ft. = Total Air Weight Tbg. ID 2.441 Ft./ Gal. 4.1135
Tbg. Length Pipe Wt./ Ft. Total Wt. Tubing Fill-Up Factors
1000 4.7 4,700.00 ( 3.141592654 x ID2 ) / 77 = Fill-Up Factor Gal./ Ft.
In Air ( Does not allow for upsets or couplings ) Tubing I.D. Fill-Up Factor Gal./ Ft.
( OD2 - ID2 ) x 2.67 x Length feet 2.441 0.24310
Pipe OD 2.375 Pipe Weight ( 3.141592654 x ID2 ) / 576 = Fill-Up Factor Ft.3./ Ft.
Pipe ID 1.995 4.43 Tubing I.D. Fill-Up Factor Ft.3/ Ft.
Length 1 2.441 0.03250
In Fluid ( lb./ ft. ) Tubing Fill-Up
Tbg. Air Wt. lb./ ft. x (1- (.01528 x Fluid Wt. lb./ ft.)) Fill-Up Factor x Barrels = Fill-Up Footage
Tbg. Wt.lb./ ft. Air Fluid Wt.lb./ gal. Tbg. Wt. In Fluid Fill-Up Factor Barrel Fill-Up Ft.
6.5 10 5.5068 172.765 10 1,727.65
Buoyancy Factor x Tubing Air Weight = Fluid Weight
Buoyancy Factor Tbg. Air Wt. Tbg. Wt. In Fluid Tubing Displacement
0.8471 4.7 3.98137 Tubing weight lb./ ft. x .0003638 = Displacement bbl./ ft.
Tubing Wt. lb./ ft. 6.5
Buoyancy Factor Displacement bbl./ ft. 0.00236
( 65.42 - Fluid Wt.) / 65.42
Fluid Wt.lb./ gal. 8.33 Factor 0.8727
Tubing Air Wt. x Buoyancy Factor x Length = Tbg. Fluid Wt.
Tbg. Wt.lb./ ft. Air 6.5 Tbg. Wt. In Fluid
Buoyancy Factor 0.8471 5506.15
Tbg. Length 1000
Pipe Stretch
Pull x Depth x 12 / ((( OD2 - ID2 ) x 0.7854 ) x 30000000 ) = Inches
Pull Depth Pipe OD Pipe ID
10000 5000 2.875 2.441
Stretch In Inches 11.04
Slack-Off Data
( Desired Wt. Dwn. / 1000 ) x ( Packer Depth / 1000 ) x Factor
Desired Wt. Down Packer Depth Factor
10000 10000 0.26
Slack-Off In. Required
Factors For Standard Weight Pipe 26
1.900" 0.68
2 3/8" 4.7 # 0.39
2 7/8" 6.5# 0.26
3 1/2" 9.3# 0.17
Factors For Standard Weight Drill Pipe
2 7/8" 10.4# 0.16
3 1/2" 13.3# 0.12
4 1/2" 16.6# 0.11
To Calculate Slack-Off Factor
e / Hose Volume
ID x ID / 1029.4
2.323
15300
Per Foot 0.0052
Total Volume 80.21
Enter Necessary Information In Highlighted A
FOR REFERENCE ONLY
Stem Weight Tubing Weight With Upsets & Coupling
( OD2 x 8 ) / 3 = Lbs./ Ft. ( OD2 - ID2 ) x .7854 x 0.29665 x 12
OD 2.125 Lb./ Ft. 12.04 Pipe OD 2.875
OD x OD x 2.667 = Lbs./ Ft. Pipe ID 2.441
OD 2.125 Lb./ Ft. 12.04
Calculated I.D.
Pipe OD 2.875
Weight 6.5
I.D. 2.415
Drift 2.290
ormation In Highlighted Areas
EFERENCE ONLY
ht With Upsets & Coupling Area Between Two Circles
D2 ) x .7854 x 0.29665 x 12 ( ID2 x .7854 ) - ( OD2 x .7854 ) = Area Between Circles
Pipe Weight Lb. / Ft. Outer Circle ID 5.000 Area
6.450 Inner Circle OD 4.000 7.069