Line sizing is an important activity in process design, the primary requirement is to find an inside
diameter that will permit a certain required throughput at a given pressure drop. This usually
involves a trial and error procedure. A diameter is chosen and the pressure drop is calculated for
the required throughput. If the calculated pressure drop is too high, a larger diameter is taken
for the next trial. If the pressure drop is smaller than necessary, a smaller diameter is chosen.
Important Factors To Consider:
Design Margin
Velocity Limitation
Pressure Drop
Economy
To save time, line sizing can be carried out by excel tools or Software applications in conjunction
with Codes and Standards. API RP 14E is the recommended standard practice for Line Sizing.
Velocity Limitations As Per API RP 14E
Liquid Line
Minimum Velocity: 3 ft/sec (To avoid sand/solid deposition)
Maximum Velocity: 15 ft/sec (To avoid flashing of liquid)
Gas Line
Maximum Velocity: 60 ft/sec (To avoid noise / vibration)
Two-Phase Line
Minimum Velocity: 10 ft/sec (To minimize slugging)
Maximum Velocity: Should be less than erosion velocity
Please follow the below steps to determine the accurate line size by using Aspen HYSYS.
Components Methane
Property Package Peng Robinson
Temperature 25 oC
Pressure 600 Kpa
Flow Rate 100,000 Kg/Hr
Pipe Length 100 ft
Fittings (Elbow) 02
Email: [email protected] Website: www.omesolglobal.com
Global A Potential Hub To Deliver Dynamic Professionals.
Step: 01
Start a New Case
Step: 02
Add Methane in a component list
Step: 03
Select Peng Robinson as a property package
Step: 04
Enter in to the Simulation Environment and add the Material Stream and input the following
parameters:
Temperature 25 oC
Pressure 600 Kpa
Flow Rate 100,000 Kg/Hr
Composition ( Methane) 100%
Email: [email protected] Website: www.omesolglobal.com
Global A Potential Hub To Deliver Dynamic Professionals.
Step: 05
Once the stream converged. Go to Attachments Analysis Click Create button
Step: 06
Select Line Sizing Manager Click Add button.
Email: [email protected] Website: www.omesolglobal.com
Global A Potential Hub To Deliver Dynamic Professionals.
Step: 07
Select Pipe Material Carbon Steel, Schedule 40 then Input the pipe length 100 ft
Click Edit button to define fittings.
Step: 08
Click Add FittingSelect Elbow Input quantity 2 and close the detailed fittings window.
Email: [email protected] Website: www.omesolglobal.com
Global A Potential Hub To Deliver Dynamic Professionals.
Step: 09
Select Flow Correlation (According to your system requirement)
Input Max Pressure Gradient 1Psi / 100ft Input Max Velocity (According To Fluid Phase)
Step: 10
Go to Details to view results.
Email: [email protected] Website: www.omesolglobal.com
Global A Potential Hub To Deliver Dynamic Professionals.
On Analysis: Recommended pipe is 800 mm.
If you want to learn new skills online. Join or expert LED training courses.
Registration Process
Kindly follow the mentioned below steps to proceed further.
Step #01: Please follow the mentioned below link for registration application submission:
https://omesolglobal.com/student_registration.php
Step #02: Please follow the mentioned below link for fee submission:
https://omesolglobal.com/submit-fee-online.php
2CheckOut.com Inc. (Ohio, USA) is a payment facilitator for goods and services provided by
Octagon Management & Engineering Solutions (Omesol).
Available Payment Methods: VISA, MASTER CARD, Paypal, Discover, American Express, Diners
Club International, JCB, Skrill, Wise.
Email: [email protected] Website: www.omesolglobal.com
Global A Potential Hub To Deliver Dynamic Professionals.
Inquire Now
E-mail: [email protected]
Web: www.omesolglobal.com
WhatsApp / Call: +1 -251-285-4593
Our Clients
Email: [email protected] Website: www.omesolglobal.com