Product Data Sheet
Edition 3, 2012
Identification no.
02 06 06 01 001 0 000001
Version no. 0010
Sikagard® -62
®
Sikagard -62
2-Part Epoxy Protective coating
®
Product Sikagard -62 is a 2-pack solvent-free high build coating material based on epoxy
Description resin.
Uses ■ As an abrasion-resistant universal coating material designed for normal to
moderately aggressive chemical environments. Sikagard®-62 is suitable for
Construction
use on concrete, stone, cementitious mortars and renderings (not polymer-
modified), epoxy cements (EpoCem), epoxy mortars, iron and steel.
■ For linings in storage tanks and silos, bund areas. As anti-corrosion coating in
food-processing plants, sewage works, farms and agricultural enterprises,
chemical and pharmaceutical plants, beverage industries and bottling plants.
Characteristics / ■ Solvent-free
Advantages ■ Good chemical and mechanical resistance
■ Easy to mix and work
■ High-build
■ Impervious to liquids
Product Data
Form
Appearance / Colours Resin - Part A: Coloured, liquid
Hardener - Part B: Transparent, liquid
Pebble grey (RAL 7032). Additional colour shades on request.
Under sun radiation it may come to discolouration and colour deviation; this has no
influence to the function of the coating.
Packaging Part A: 3.75 kg containers
Part B: 1.25 kg, containers
Part A+B: 5.0 kg ready to mix units
Storage
Storage Conditions/ 12 months from date of production if stored properly in undamaged sealed
Shelf-Life containers in dry conditions at temperatures between +5°C and +30°C.
Technical Data
Chemical Base Epoxy resin
Density Part A: ~ 1.45 kg/litre
Part B: ~ 1.02 kg/litre
Mixed resin: ~ 1.37 kg/litre
All density values at +23°C
Solid Content ~ 100% (by volume), ~ 100% (by weight)
Mechanical / Physical
Properties
Bond Strength > 1.5 N/mm² (failure in concrete) ISO 4624
Resistance
Chemical Resistance See separate chemical resistance list
Thermal Resistance
Exposure* Dry heat
Permanent +50°C
Short-term max. 7d +80°C
Short-term max. 12 h +100°C
Short-term humid heat* up to +80°C where exposure i s only occasional (steam
cleaning etc.).
*No simultaneous chemical load.
1 Sikagard® 62 1/4
System
Information
System Structure Roller coating:
Primer: 1 x Sikagard®-62
Coating: 2 - 3 x Sikagard®-62
Application Details
Consumption / Dosage
Coating System Product Consumption
Roller coating
®
Priming Sikagard -62 0.3 - 0.5 kg/m²
®
Roller coating Sikagard -62 0.3 - 0.7 kg/m² per coat,
depending on substrate
condition and coating
thickness required
For a theoretical dry film thickness of 100 microns (0.1 mm) approx. 0.14 kg/m².
These figures are theoretical and do not include for any additional material required
due to surface porosity, surface profile, variations in level or wastage etc.
Substrate Quality The concrete substrate must be sound and of sufficient compressive strength
2 2
(minimum 25 N/mm ) with a minimum pull off strength of 1.5 N/mm .
The substrate must be clean, dry and free of all contaminants such as dirt, oil, grease,
coatings and surface treatments, etc.
If in doubt apply a test area first.
Substrate Preparation Concrete substrates must be prepared mechanically using abrasive blast cleaning
or scarifying equipment to remove cement laitance and achieve an open textured
surface.
Weak concrete must be removed and surface defects such as blowholes and voids
must be fully exposed.
Repairs to the substrate, filling of blowholes/voids and surface levelling must be
® ® ®
carried out using appropriate products from the Sikafloor , SikaDur and Sikagard
range of materials.
The concrete or screed substrate has to be primed or levelled in order to achieve
an even surface.
High spots must be removed by e.g. grinding.
All dust, loose and friable material must be completely removed from all surfaces
before application of the product, preferably by brush and/or vacuum.
Steel surfaces must be prepared by blast cleaning to Sa 2 ½ (ISO 8501-1) or
SSPC-SP 10. All weld splatter has to be removed joints and welds must be grinded
in accordance with EN 14879-1. An average surface profile Rz ≥ 50µm must be
achieved, the substrate has to be free from contaminants detrimental to adhesion,
preferably by high pressure water jetting prior of blast cleaning.
Application
Conditions / Limitations
Substrate Temperature +8°C min, +30 °C max
Ambient Temperature +8C min, +30 °C max
Substrate Moisture ≤4% moisture content. Test method: Sika®-Tramex or CM.
Content No rising moisture according to ASTM (Polyethylene-sheet).
Relative Air Humidity 80% r.h. max
Dew Point Beware of condensation!
The substrate and uncured floor must be at least 3ºC above the dew point to
reduce the risk of condensation or blooming on the floor finish.
Application
Instructions
Mixing Ratio / Dosage Part A : Part B = 75 : 25 (by weight)
Mixing Time Prior to mixing stir Part A mechanically. When all of Part B has been added to Part
A continuously mix for 3 minutes until a uniform mix has been achieved.
To ensure thorough mixing pour materials into another container and mix again to
achieve a consistent mix.
Over mixing must be avoided to reduce air entrainment.
®
Mixing Tools Sikagard -62 must be mechanically mixed using an electric power stirrer (300 -
400 rpm) or other suitable equipment.
Sikagard® 62 2/4
2
Application Method / Coating:
Tools Sikagard®-62 , can be applied with a distemper brush, a short-piled, solvent
resistant, non-fuzzy roller or by airless spray equipment
Cleaning of Tools Clean all tools and application equipment with Thinner C immediately after use.
Hardened/cured material can only be mechanically removed.
Potlife Max. open times
Temperatures Time
+10°C ~ 30 mins
+20°C ~ 20 mins
+30°C ~ 10 mins
Waiting Time / ® ®
Before applying Sikagard -62 on Sikagard -62 allow:
Overcoatability Substrate Temperature minimum maximum
+10°C 30 hours 3 days
+20°C 10 hours 2 days
+30°C 6 hours 1 days
Times are approximate and will be affected by changing ambient conditions.
®
Notes on Application / Do not apply Sikagard -62 on substrates in which significant vapour pressure may
Limitations occur.
® ®
If > 4% moisture content, Sikafloor EpoCem may be applied as a T.M.B.
(temporary moisture barrier) system.
Stability in vertical surface: < 300 µm (wet film thickness)
®
Freshly applied Sikagard -62 must be protected from damp, condensation and
water for at least 24 hours.
Avoid puddles on surface.
The incorrect assessment and treatment of cracks may lead to a reduced service
life and reflective cracking.
®
For exact colour matching, ensure Sikagard -62 is applied from the same control
batch numbers.
Curing Details
Applied Product ready
for use Temperature Foot Traffic Light Traffic Full cure
+10°C ~ 2 days ~ 5 days ~ 14 days
+20°C ~ 1 day ~ 4 days ~ 10 days
+30°C ~ 18 hours ~ 2 days ~ 5 days
Times are approximate and will be affected by changing ambient conditions.
Value Base All technical data stated in this Product Data Sheet are based on laboratory tests.
Actual measured data may vary due to circumstances beyond our control.
Local Restrictions Please note that as a result of specific local regulations the performance of this
product may vary from country to country. Please consult the local Product Data
Sheet for the exact description of the application fields.
Health and Safety For information and advice on the safe handling, storage and disposal of chemical
Information products, users shall refer to the most recent Material Safety Data Sheet containing
physical, ecological, toxicological and other safety-related data.
Sikagard® 62 3/4
3
Value Base All technical data stated in this Product Data Sheet are based on laboratory
tests. Actual measured data may vary due to circumstances beyond our control.
Legal Notes The information, and, in particular, the recommendations relating to the application and end-use of Sika
products, are given in good faith based on Sika’s current knowledge and experience of the product when
properly stored, handled and applied under normal conditions in accordances with Sika’s recommendations. In
practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect
of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship
whatsoever, can be inferred either from this information, or from any written recommendations, or from any
other advice offered. The user of the product must test the product’s suitability for the intended application and
purpose. Sika reserves the right to change the properties of its products. The proprietary rights of third parties
must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always
refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will
be supplied on request.
Construction
PT. Sika Indonesia Branches
Jl. Raya Cibinong- Bekasi km. Surabaya :
20 Komp. Pergudangan Meiko Abadi III Blok B-52 & B-53, Ds. Gemurung,
Limusnunggal- Cileungsi Gedangan, Sidoarjo 61254
BOGOR 16820 - Indonesia Tel : 031-8911333; Fax : 031-8916333
Tel. +62 21 8230025 Medan :
Fax +62 21 8230026 Jl. Serbaguna (Simp. Jalan Veteran), Kompleks Pergudangan Brayan
Website : www.sika.co. id Trade Center No. 34, Medan 20239
idn.sika.com Tel : 844 6697, 844 6997 ; Fax : (061) 844 6698
e-mail:
[email protected] Batam :
Jl. Laksamana Bintan, Komp. Bumi Riau Makmur Blok E No.3, Sungai
Panas
Tel : (0778) 424928; Fax : (0778) 450189
Sikagard® 62 4/4
4