FORMAT NO: QA-FR-04
REVISION NO: 0
DATE: 21-06-2017
MATERIAL TEST CERTIFICATE AS PER EN -10204 / 2004 / TYPE 3.1
PROJECT TC NO.: ASPL/2795/ T-038 DATE :- 09/01/2024
CUSTOMER NAME
PO. NO.
PRODUCT :- AUSTENITIC SUPER DUPLEX SEAMLESS PIPES
SPECIFICATION :- ASTM A790/A790M-22 UNS S32750
Hydro Test Pressure
Length In Qty. Qty.
Sr. No. Heat No. Size Pressure Results Holding End Finish
Mtrs In Nos. In Mtrs
(PSI) Time
1 ASPL28304 2" NB X SCH 40S 5.0 - 7.0 26 163.50 2500 Satisfactory 5 - 10 SEC. PE
2 ASPL28415 2-1/2" NB X SCH 40S 5.0 - 7.0 35 220.30 2500 Satisfactory 5 - 10 SEC. PE
3 ASPL28426 3" NB X SCH 40S 5.0 - 7.0 19 120.50 2500 Satisfactory 5 - 10 SEC. PE
CHEMICAL COMPOSITION %
C% Si % Mn % P% S% Ni % Cr % Mo % N% Cu % PREN
Sr. No. Heat No.
0.030 0.80 1.20 0.035 0.020 6.00 Min. 24.00 Min. 3.00 Min. 0.24 Min. 0.50
Max. Max. Max. Max. Max. 8.00 Max. 26.00 Max. 5.00 Max. 0.32 Max. Max.
1 ASPL28304 0.018 0.31 0.86 0.024 0.003 6.24 25.12 3.47 0.26 0.27 40.73
2 ASPL28415 0.019 0.26 0.91 0.025 0.003 6.28 24.85 3.56 0.28 0.25 41.08
3 ASPL28426 0.018 0.24 0.82 0.022 0.002 6.19 25.24 3.54 0.28 0.32 41.40
MECHANICAL TEST
Yeild Strength Elongation % Hardness
Tensile Strength (Mpa.) Flattening
Sr. No. Heat No. (Mpa.) GL = 50mm HBW Macro Test Flange Test Flaring Test
800 Min. Test
550 Min. 15 Min. 300 Max.
Confirming
1 ASPL28304 915.34 623.21 28.13 265 Satisfactory NA NA
Seamless
Confirming
2 ASPL28415 907.13 617.48 24.26 269 Satisfactory NA NA
Seamless
882.75 631.52 Confirming
3 ASPL28426 25.71 267 Satisfactory NA NA
Seamless
HEAT TREATMENTS :- SOLUTION ANNEALED AT 1100° C & RAPIDLY WATER QUENCHED.
REMARK:-
1. 100% Visual Checked - Found Satisfactory.
2. 100% Dimensions as per ASME B36.19M - Found Satisfactory.
3. No welding or weld repair
4. 100% PMI Checked - Found Satisfactory.
5. 100% Pickling & Passivation Carried out - Found Satisfactory.
6. Corrosion Test - Satisfactory.
7. This is to Certify That above Pipes also Meet The Genernal Requirement of Specification ASTM A - 999
8. Material free from mercury and radioactive contamination.
INSPECTORS / CLIENT'S SIGN INSPECTION AUTHORITY MANAGER - QUALITY CONTROL
The Material was Manufactured, Tested & Inspected in accordance with Specification & P.O Requirements.
Office & Works
Office : 7 , Bhanshali House , 1 st Floor , 9 Th Khetwadi Line , Mumbai - 400 004 / Tel - 022 23862124 / 022 6636 2233 / 022 23879241
Works : F - 1/6 - 1 /8 M I D C Tarapur ,Boisar (W ) , Dist - Palghar -401506 / Tel - 02525 273289 / 279063