Oil Analysis Web
Oil Analysis Web
WHAT’S IN MY OIL?
Check for:
Wear Metal Elements
Contamination Levels
Oil Analysis provides vital information as to the condition of both the oil and the engine being tested. It can
detect wear and contamination problems that, if left unchecked, can severely effect engine performance or
cause engine failure.
To achieve the maximum benefit oil samples must be taken at regular intervals with details supplied about the
sample to include:
• Lube brand/type • Total engine hours
• Viscosity grade • Engine hours since last oil change/sample
• Lube system capacity • Amount of oil added since last oil change/sample
The more information provided the more useful the results of the analysis are likely to be.
The recommended oil sampling interval for a marine diesel engine is every 500hrs & just prior to oil changes.
Regular sampling will enable abnormalities to be detected, allowing pre-emptive action to be taken to prevent
further damage.
The easy to interpret laboratory report includes readings for each element tested with abnormal readings
highlighted, along with an overall rating for your engine as either “normal”, “caution” or “warning”.
Don’t wait until it is too late and expensive repairs are necessary.
Contact AMS today to find out more about how regular oil analysis can save you money.
m
Alarm Limit
B
Lab ID 359005 A Alarm Limit Matrix -Set Name
S (Equipment type / oil type)
Test Method
Bottle ID 1111992
E
Result
co
L
Oil Hours (Kms) Not Given I XXX General SAE 40
Unit Hours (Kms) s- le 1026.2 N
Oil Change E
Oil Added (Liters)
Filters Hours (Kms)
a.
Fine Wear Coarse Wear
Wear Condition
m p
Reference (RDE) (RFS)
Fine Wear Coarse Wear Oil U-Caution U-Warning U-Caution U-Warning
Wear Element
Method Unit (RDE) (RFS) (RO)
Iron D-6595 PPM 14.7 0.1 >25 >50 >25 >50
Chromium D-6595 PPM 1.0 0.1 >5 >10 >5 >10
.a m
se
Lead D-6595 PPM 0.0 0.1 >10 >20 >10 >20
Copper D-6595 PPM 14.4 C 1.0 >10 >15 >10 >15
Tin D-6595 PPM 0.0 0.1 >5 >10 >5 >10
Aluminum D-6595 PPM 0.9 0.1 >10 >20 >10 >20
Sa
Note: Alarm Limits are variable and dependent upon dataset size and to be used as general guideline.
No Sign or : NORMAL , C or : CAUTION ( first level warning limit ) , W or : Warning ( second level warning limit )
Samutprakan 10280, Thailand.
Accuracy of interpretation and recommendation are based on representatives sample and information supplied. No warranty is expressed or implied for this report.