Coarse and Fine Aggregate Specification Limit
Coarse and Fine Aggregate Specification Limit
383- 2016
Graded Aggregate of Nominal
20 MM Aggregate 10 MM Aggregate
Size (20 MM)
Fine Aggregate
Silt & Clay content of FA Not more than 3% as per RVNL specification Volume-1, Part-A-Bridges.
Clause No. 2.1
AIV Not more than 45% as per IS 383:2016, Clause No. 5.4.2
Combined FI & EI Not more than 40% as per IS 383:2016, Clause No. 5.3
Abrasion Value Not more than 50% as per IS 383:2016, Clause No. 5.4.3
ITL- KEC JV
Package-3- Construction of Roadbed, bridges, supply of ballast, Installation of track (excluding supply of rails, thick web
switches & BG main Line PSC sleepers),Electrical (Railway Electrification and General Electrification), "Design, Supply, Erection,
Project Testing and commissioning of signalling and Telecommunication works involving Outdoor works at 3(Three) Stations
AMBODALA, DOIKALLU, MUNIGUDA, in connection with construction of 3rd line track between Lanjigarh road(KM 250.4)(ex)
Bissamcuttack (KM 304.80)(ex) in Sambalpur Division of East Coast Railway, Odisha, India.”
Proposed Use:
63 mm 100
40 mm 85-100
20 mm 0-20
10 mm 0-5
Remarks :