Measuring Level Correctly & Reliably !!

Ultimate Solution for Stock Management

The housing is so robust that the unit’s durability under


harsh conditions may be incomparable.
It can be appliedto every process !!

CAT.No.S-150-1405E
Ultimate Solution for Stock
Management Reliably Catching Level
for Powder, Granules & Lumps
This is the general-purpose level meter having a good
market share as a level meter for powder, granules
and lumps stored in a tank, a silo or the like.
It can be used for versatile purposes as a level meter
for all sorts of powder, granules, and lumps.
CPU Built-in

■ PRINCIPLE OF OPERATION
1 When a start signal is input, the motor
starts up and then the metering tape comes
out, followed by the weight descending.

2 The motor stops when the weight touches on the


measuring substance, and level measurements are output

3 When the motor reversely rotates to get the weight


back to the roll-up-complete position, it stops.

4 The unit stands by awaiting the next start signal


Withstand-pressure
Explosion-proof
ExdⅡ BT4

Just push a measuring button on


any tanks, and, with only this touch,
you can select the tank to measure
and start measuring !!

1
CPU Built-in

Standard

Standard

Standard

2
Intelligent CPU Built-in
Model Overload Detection Spring

Balance Weight

Photosensor for Powder


Winding Drum Surface Detection

Count Cam
Motor
Overload Detection
Photosensor

CPU Built-in
Count Pulley
Ultimate Solution for
Stock Management !! Roll-up-complete Lever

CPU being built in a rugged Pulse Transmission Roll-up-complete Photosensor


Photosensor
body, the unit is weatherproof Roll-up Cam
and can effectively operate
under any circumstances including
a pressured tank. 160
4
Tape 1
3 2
Tape Stopper Chain

385
Φ180
Example of Equipment Configuration Weight

199
Chain Rotation Axis
89
Transmitted pulses may be indicated directly
220 215
on an Electromagnetic counter or on an electronic
counter via Control Unit, or may be displayed as
analog outputs via P/I Converter from Control Unit.

182
500
Start Push-button Start Push-button

365
C C 1 Main Frame AC 9
P P 2 Motor Cover AC
U Power U Power
3 Drum Cover AC 5
4 Control Board AC
Terminal Box JIS5K125A
5 Mounting Flange SS400 8
390±50
RST
K/P
OUT
6 Weight SUS304
7
Pulse MODE 4 3 2 1
DC4∼20mA 7 Chain Rotation Axis SUS304 Φ90
RST
8 Tape Stopper SUS304
Bar-graph Meter 6
Electronic Digital Counter 9 Conduit Connection 2-G 1/2

■ Standard Specification ■ Circuit Board Layout / Interconnecting Diagram


Power Voltage : 100VAC or 200VAC, Single-phase 50/60Hz Measurement Light Output Pulse(1cm/10cm) / 1 pulse
Consumption : Max. 150VA Weight Descending Light Changeover Jumper(10cm at short-circuit)
Allowable Temperature : ambient - 10°C ~ + 50°C (No freezing /condensation) Power Indication Light (1cm at open-circuit)
Inside tank - 10°C ~ + 80°C (No freezing/ condensation)
Measuring Span : Standard 20m ( Max. 40m Option) Failure Alarm Light
Measuring Method : Pulse Counting Pushing Button for Site Measuring
Measuring Unit : 1 pulse/10cm, or 1 pulse/1cm Auto-measuring-time Setup Dial
Measuring Accuracy : ±10cm / ±1cm ×10
Motor : Single-phase, Reversible, Output 40W Setup Dial for Lower Limit
×100
(unit by cm)
30 minutes rating, with brake ×1000
Elevating Speed : 8.8m/min(50Hz), 11.0m/min(60Hz), ×10
Setup Dial for Upper Limit
Measure : SUS304, CSP tape W32 x Thick 0.3mm ×100
(unit by cm)
Cutoff Load : 9kN ×1000
Output Signal : Current signal DC4 ~ 20mA (indicate remains). Power Switch
User can set up
DC20 ~ 4mA(indicate vacated portion) either one Circuit Fuse for Operation
Pulse contact signal 1 pulse / 1cm 1110 9 8 7 6 5 4 3 2 1
User can set up
(No-volt signal) 1pulse / 10cm either one − Output
M
+ R C
Built-in Timer : Measuring stand-by time can be adjusted via a set-up.. Pulse Contact for Counter
:50msec ON
Measuring Contact Output (Closed in measurement)
Current Indicator
Pushing & Auto Measuring Switch
Failure Alarm Contact Output
Measuring & Failure Alarm Contract Common Terminal,
Counter Common Terminal
Reset-pulse Contact Output
Count-pulse Contact Output
AC Power Input

Output Contact : Reset Contact / for Remote Indication Counter, ON at the time of reset (The setup of 1 pulse/1cm and 1 pulse/10cm
Failure Alarm Contact/ Flickers when the measuring tape is cut off. can arbitrarily be made by the jumper)
The contact is closed when the weight is buried. Reset Contact for Counter
Body material : Aluminum casting : Setting commencement 0.1sec ON 1a.
Current Output DC4-20mA
Mounting Method : JIS 5K 125A Load Resistance max. 400Ω
Protection Rank : IP67 Failure Alarm Contact
Weight : 45kg : Flickers when the measuring tape is cut off.
The contact is closed when the weight is buried.
Note: Use a shielded cable for Terminal 3 – 5 and 8 – 10

3
Rugged Withstand-pressure Explosion-proof
The level indications are directed from the remote.
That requires no site measurement, and you can For Explosive Environment
expect much improvement in terms of the working
Withstand-pressure
and safety environment. Explosion-proof
ExdⅡ BT4

It can reliably operate


regardless of particulates,
temperature changes,
CPU Built-in and electric fluctuation of
measuring substances.
CPU Built-in Model of It can measure explosive substances
Compact Size as well as effectively function in the
explosive gas environments such as
Suitable for level control chemical/medical factories, power
of Hopper Bin or the like station or the like.
in smaller capacity

278
187
68 372
339 314
200 139 66 248 465 440
3 1
1
71
2 10
309

3
573

4
440

314
8 2
100

5
6
1 Main Frame AC
2 Motor Cover AC JIS10K100A
JIS5K100A 4
3 Pulley Cover AC
Control Board AC
400±50

4 6
560±50

7 Terminal Box 7
5 Mounting Flange SS400 1 Main Frame AC 5
Φ38 6 Measuring Tape SUS304 2 Motor Cover AC
170

7 Weight SUS304 3 Drum Cover AC 8


8 Conduit Connection 2-G 1/2 4 Mounting Flange SS400 9
5 Tape SUS304
6 Cleaner PA
7 Roll-up-complete Rod SUS304
■ Standard Specification 8 Chain SUS304
9 Weight SUS304
Power Voltage : 100VAC or 200VAC, Single-phase 50/60Hz 10 Conduit Connection G 3/4”
Consumption : Max. 90VA Pressure Tight Gland(Cable dia. Φ14 – Φ16)
Allowable Temperature : - 10°C ~ + 50°C (No freezing / no condensation)
Measuring Span : 0 ~ 20m
Measuring Method : Pulse Counting ■ Standard Specification
Measuring Unit : 1 pulse/10cm or 1 pulse/1cm
Power Voltage : 100VAC or 200VAC, Single-phase 50/60Hz
Measuring Accuracy : ±10cm / ±1cm
Consumption : 150VA
Motor : Single-phase, Reversible, Output 25W
Allowable Temperature : ambient -10°C ~ + 40°C (No freezing / condensation)
30 minutes rating, with brake
inside tank -10°C ~ + 40°C (No freezing / condensation)
Elevating Speed : 7.2m/min (50Hz), 8.5m/min (60Hz),
Measuring Span : 0 ~ 20m (Max. 30m Option)
Measure : SUS304, CSP tape W10 x Thick 0.2mm
Measuring Method : Pulse Counting
Cutoff Load : 1kN
Measuring Unit : 1 pulse/10cm
Output Signal : Current signal DC4 ~ 20mA (indicate remains).
User can set up Measuring Accuracy : ±10cm
DC20 ~ 4mA(indicate vacated portion) either one Motor : Single-phase Output 40W, Class E Insulating
Pulse contact signal 1 pulse / 1cm
User can set up 33% ED twice/hour (condenser 15μF)
(No-volt signal) 1pulse / 10cm either one Single-phase 200VAC 40W Class E Insulating
Built-in Timer : Measuring standby time can be adjusted by a set-up.
33% ED twice/hour (condenser 3.5μF)
Output Contact : Reset Contact / for Remote Indication Counter, ON at the time of reset
Elevating Speed : 8.8m/min(50Hz), 11.0m/min(60Hz),
Failure Alarm Contact/ Flickers when the measuring tape is cut off.
Measure : SUS304 - CSP tape W32 x Thick 0.3mm
The contact is closed when the weight is buried.
Cutoff Load : 9kN
Body material : Aluminum casting
Body material : Aluminum casting
Mounting Method : JIS 5K 100A
Mounting Method : JIS 10K 100A
Protection Rank : IP67
Protection Rank : Indoor (Provide with raintight cover for outdoor use)
Weight : 20kg
Weight : 75kg

4
VERSATILE MODEL HAVING CUSTOMERS’
Standard
CONFIDENCE AND A GOOD MARKET SHARE
This is the general-purpose A Model of Medium size, suitable
level meter having a good market for Pressured Tank, Silo or the like.
share as a level meter for powder
& granules. Housed in aluminum casting, it is so
occlusive that it may be dustproof,
Stainless tape being adopted as a metering pressure-proof and weatherproof.
device, it can be used for versatile purposes
as a level meter for all sorts of powder &
granules.

Standard
425 360
350 75 294 66 326 314
1 200 126 66 248
1
Main Frame 2
1 SPCC
Measuring Tape

309
2 304SS
577

3
3 Mounting Flange SS400
4
4 Weight 304SS
5 Cleaner Polyacetal 8
3
100

6 Chain 304SS 5
7 5
2
7 Conduit Connection Φ27 1 Main Frame AC
6
2 Motor Cover AC
3 Pulley Cover AC
JIS10K100A 6 JIS5K100A

400±50
560±50

4 Terminal Box AC
7
5 Mounting Flange SS400
4
Φ38 Measuring Tape 304SS
170
6
Φ90
190

7 Weight 304SS
8 Conduit Connection G 3/4

Standard Specification Standard Specification


Power Voltage : 100VAC or 200VAC 50/60Hz Power Voltage : 100VAC or 200VAC 50/60Hz
Consumption : 150VA Consumption : 90VA
Allowable Temperature : ambient -10°C to +50°C (No freezing / condensation) Allowable Temperature : ambient -10°C to +50°C (No freezing / condensation)
inside tank -10°C to +80°C (No freezing / condensation) inside tank -10°C to +80°C (No freezing / condensation)
Measuring Span : 0 – 20m (Max. 40m Option) Measuring Span : 0 - 20m
Measuring Method : Pulse Counting Measuring Method : Pulse Counting
Measuring Unit : 1 pulse/10cm Measuring Unit : 1 pulse/10cm
Measuring Accuracy : ±10cm Measuring Accuracy : ±10cm
Motor : Single-phase, Reversible, Output 40W Motor : Single-phase, Reversible, Output 25W
30 minutes rating, with brake 30 minutes rating, with brake
Elevating Speed : 9.3m/min (50Hz), 11.0m/min (60Hz), Elevating Speed : 7.2m/min (50Hz), 8.5m/min (60Hz),
Measure : Tape / 304SS W32 x Thick 0.3mm Measure : 304SS – CSP tape W10 x Thick 0.2mm
Cutoff Load : 9kN Cutoff Load : 1kN
Body material : SPCC Body material : Aluminum Casting
Mounting Method : JIS 10K 100A Mounting Method : JIS 5K 100A
Protection Rank : IP33 or equivalent Protection Rank : IP67
Weight : 53kg

Start Push-button Start Push-button


Auto-measuring Timer
Auto-measuring Timer
Example of Equipment Configuration
Transmitted pulses may be indicated RST
K/P
OUT

directly on an electromagnetic counter or MODE 4 3 2 1

on an electronic counter via Control Unit, RST

or may be displayed as analog outputs AU P/I Bar-graph Meter AU Electronic Counter


via P/I Converter from Control Unit. Control Unit Converter M-B101 Control Unit
Power Power

2-Φ4.5
Control Unit (KSLAU)
Supply Voltage : 100 / 110AC, 200 / 220V
50/60Hz as specified (same voltage as detector)
Output Contact Capacity : Rated load 250VAC 5A 30VDC 5A (resistance load)
230
208
250
230
250

Minimum Applicable Resistance Load 5VDC 10mA


Allowable Ambient Temperature : 0°C to +50°C
Color : Munsell 5Y 7/1
12
Housing Material : Steel Plate
Weight : 1.7kg 2 -Φ 5
120 100 70 143.5

5
Microprocessor-Control
CONTROLLER
●Selecting a Tank with One-touch Operation
●Discretionary Detection by Application
Compact model used ●Intelligent Diagnosis, Equipped with Memory
for a hopper bin in smaller Function
capacity.
This is a convenient type to be used for System Outline
a less capacious storage tank which is The descent distance of measuring tape/wire may be converted to
placed in light-industry processing the stock volume in a tank.
facilities including flour, feeding stuff, The detector detects in a mechanical manner.
plastic and so on. The measuring findings can be shown by height(m), %, ton & m3.
You can select an indication of either Remains or Vacated Portion.

Applicable Models
KSL-T8(AUType), KSL-T2, KSL-W3T, KSL-W2B
Indicator / Indication Light
Standard

Clearance between
two mounting holes
320 312

254

278
280 228 84

4UNITS
connectable
4-Φ7Hole
290

164
1 Clearance between Detector-selection
two mounting holes Push Button
188 Depth130
100

3 1 Main Frame SPCC


JIS5K100A 2 2 Measuring Wire 304SS
300±50

3 Mounting Flange SS400 H F D B


Φ38 5 Weight
170

4 304SS
5 Chain 304SS G E C A
4
6 Conduit Connection Φ27

Standard Specification 8 UNITS


connectable
Indicator / Indication Light

Power Voltage : 100VAC or 200VAC 50/60Hz


Clearance between
two mounting holes

Consumption : 70VA
Allowable Temperature : ambient -10°C to +50°C (No freezing / condensation)
272

300

inside tank -10°C to +80°C (No freezing / condensation)


Measuring Span : 0 – 20m
Measuring Method : Pulse Counting
Measuring Unit : 1 pulse/10cm 372 4-Φ7Hole
Measuring Accuracy : ±10cm Clearance between two mounting holes
Motor : Single-phase, Reversible, Output 15W 400 Depth180
30 minutes rating, with brake Detector-selection
Push Button
Elevating Speed : 7.0m/min (50Hz), 8.6m/min (60Hz), Standard Specification
Measure : 304SS Wire Φ1.5mm 7 x 19 Z-Stranding Housing Type : Indoor Wall-mounted Type DS4
Cutoff Load : 1.7kN W188 x H278 x D130mm
Body material : SPCC DS8 W400 x H300 x D180mm
Mounting Method : JIS 5K 100A Allowablee Temperature : 0 to +50°C
Protection Rank : IP33 or equivalent Power : 100VAC or 200VAC±10% 50/60Hz
Weight : 20kg Configured Detector : Select from KSL-W2B, W3T, T2,
T8 (AU model) and so on.
Number of Connected Detectors : DS4 / 4 units, DS8 / 8 units
Cable Type : Regular Control Cable (No extension limit)
Number of Cable Cores : W2B : 6 cores
W3T, T2, T8 (AU model) : 7 cores
Installed Equipment Measuring Range : 0 – 20m (T2, T8(AU model) Option Max.40m)
*Varied by a selected detector
P/I Converter (PSC-222) Indicator : 7-segment LED (W8 x H14.2mm)
Supply Voltage : 100/200VAC ±10% 50/60Hz Level Indication : Height (m), Specific Volume Bulk (%),
Consumption : 4VA Conversion (m3, ton) – No
Level Output : 4 – 20mADC Allowable load resistance 1kΩ unit indicated
Output Contact Capacity : Rated load 250VAC 3A 30VDC 3A (Resistance load) Indication Format : Set up to indicate either vacated portion or remains.
*Contact output of Upper/Lower limit Minimum Applicable Indicated Conversion Values : Discretional (in the range of 0 to 999)
Load 1VDC 10mA
Memory Function : EEPROM, Set Values or Values formerly measured
Allowable Ambient Temperature : 0°C to +50°C
Diagnostic Function : Burial Alarm, Measure Cut-off Alarm
Painted Color : Munsell N7
Housing Material : Steel Plate
depend on Selected Detector
Setting Range : 0-99.9m External Output : Not available

6
KSL-T8
KSL-GT
KSL-T2 Standard Weight Opened/Float-type Chain-type Weight
SUS304 Weight SS400 or
Various Types SUS304 SUS304
(Low Specific Gravity) (for lumps)
of Weight
Φ90
Φ400

KSL-MT
KSL-W2B
KSL-W3T
Standard Weight Umbrella-type Weight Disc-shaped Weight
Various Types SUS304 SUS304
(Low Specific Gravity)
SUS304
(Low Specific Gravity) Φ90
of Weight
Φ38 Φ300

Please advise the following information for your inquiries and ordering. Installed Equipment

1.Name of Measuring Substance Meter Relay LV1000-AI-A2


Power supply : AC85 to 264V (50/60Hz)
2.Specific Gravity of the Substance DC12 to 24V ±10%
Power consumption : Max 22VA (Option 10W)
Sensor supply voltage : DC24V (150mA)
3.Granularity of the Substance
Analog Current Output : DC4 to 20mA
(Resistance load Max.500Ω)
4.Granularity of the Substance Analog Current Input : DC4 to 20mA
(Input resistance 250Ω)
5.Temperature in a Tank °C Contact capacity : AC250V 0.3A
(Resistance load)
DC30V 2A
B 6.Pressure in a Tank Pa (Resistance load) Max 60w
Linearization function : 20 points
7.Ambient Temperature °C Alarm contact output : 2c

8.Power Voltage
Electronic Digital Counter (H7CX-A114)
Size : DIN48 x 48mm
Power Voltage : 100 – 240VAC
A
50/60Hz (common)
Consumption : about 9.2VA
Display : 7 segment, Negative
A.Measuring Range
Transmissive LCD in 4 digit)
Input : Contact / Open the contact or
B.Nozzle Height short circuit.
Features : Select either addition or subtraction.
A counter that can operate the control
output when a set number is counted

Line of business All-round Manufacturer of Level Controllers for Powder, Granules and Liquid
• Rotary Paddle Type Level Switch • Conductance Type Level Switch
• Vibration Type Level Switch • Float Switch
Headquarters :
• Swing Type Level Switch • Float Type Level Indicator
2-14, Togano-cho, Kita-ku, Osaka 530-0056, Japan
• Acoustic Level Switch • Ultrasonic Type Level Indicator
TEL. 81-6-6312-2071 FAX. 81-6-6314-0848
• Capacitance Type Level Switch • Equipments For Conveyor Lines e-mail: [email protected]
• Capacitive Proximity Sensor • Dust Monitor System http://www.kansai-automation.co.jp
• Capacitance Type Level Indicator • Zirconia Oxygen Analyzer
Tokyo Branch : 1-29-6, Hamamatsu-cho, Minato-ku. Tokyo 105-0013, Japan
• Diaphragm Type Level Switch • Laser Type Level Indicator TEL. 81-3-5777-6931 FAX. 81-3-5777-6933
• Tilt Switch • RADAR Type Level Indicator Nagoya Office : 3-31-27, Uchiyama, Chigusa-ku, Nagoya 464-0075, Japan
• Leak Type Level Switch • On-line Sensors for Accurate TEL. 81-52-741-2432 FAX. 81-52-741-1588
• Microwave Switch Liquid Analysis Kyushu Office: 1-2-39, Asano, Kokura Kita-ku, Kitakyushu 802-0001, Japan
TEL. 81-93-511-4741 FAX. 81-93-511-4580
• Sounding Bob Type Level Indicator • Ultrasonic Flow meter
• Flow Switch Agent

*Please be sure to read USER'S GUIDE, Installation & Operation


Instructions before using the instrument.
*The specifications herein may be subject to change without advance notice.

You might also like