Latest WIFI Tuya Thermosats

Wifi Control

HY818 / HY818 WIFI


1.Can be used for 3heat/2 cool system ,heat pump
system etc. 3 stages heating
2.Power supply: Battery or AC20-28V
3.Load:30DC/2A or 125AC/5A
4.Working environment temperature:-10-60℃
5. Default of setting point:5~35℃
6. Accuracy:±0.5℃
7.Size:140*90*32mm
8. Program mode :7 /5+1+1 day program
9. Support Centigrade and Fahrenheit
10.Reminder of replacing filter, Reminder of replacing
UV lamp

HY517/ HY517 -WIFI


1.Power: 90-240Vac 50/60HZ
2. Range of temperature display::0~40°C
3.Display accuracy::0.5°C
4. Insulating condition: Normal environment
5. Probe sensor::NTC(10k)1%
6. Running program: Set per 1 week as a cycle
7.Contact capacity::3A/250V(WW);16A/250V(WE)
8.Output: Switch relay
9. Working environment temperature::0~90°C
10. Installation: Wall mounted
11. Range of temperature adjustment::5~35°C
12. Size(mm):55*55*27

HY518/ HY518-WIFI
1.Power: 90-240 Vac 50/60HZ
2. Range of temperature display::0~40°C
3.Display accuracy::0.5°C
4. Insulating condition: Normal environment
5. Probe sensor::NTC(10k)1%
6. Running program: Set per 1 week as a cycle
7.Contact capacity::3A/250V(WW);16A/250V(WE)
8.Output: Switch relay
9. Working environment temperature::0~90°C
10. Installation: Wall mounted
11. Range of temperature adjustment::5~35°C
12. Size(mm):55*55*27

HY607/HY607-WiFi
1.Power: 90-240Vac 50/60HZ
2.Range of temperature display::0~40°C
3.Display accuracy::0.5°C
4.Insulating condition: Normal environment
5.Probe sensor::NTC(10k)1%
6.Running program: Set per 1 week as a cycle
7.Contact capacity::3A/250V(WW);16A/250V(WE)
8.Output: Switch relay
9.Working environment temperature::0~90°C
10.Installation: Wall mounted
11.Range of temperature adjustment::5~35°C
12.Size(mm):86*86*27
Zigbee Radiator Heating Thermostat
HY366/HY366-WIFI ZigBee
(work with control box for boiler Optional)
1.Power: 2* AA* 1.5V alkaline batteries
2.Maximum current:90mA
3.Working temperature:-10~60°C
4.Display accuracy:0.5°C
5.Default range of temperature adjustment:5~35°C
6.Probe sensor: NTC(10k)1%
7.Range of temperature display:0~70°C
8.Thread size:M30*1.5
9.Insulating condition: Normal environment
10.Size(mm): 66*52*82+20mm
11.Running program: Set per 1 week as a cycle
12.Maximum route:4.5mm

HY367/HY367-WIFI ZigBee
(work with control box for boiler Optional)
1.Power: 2*AA* 1.5V alkaline batteries
2.Maximum current:90mA
3.Working temperature:-10~60°C
4.Display accuracy:0.5°C
5.Default range of temperature adjustment:5~35°C
6.Probe sensor: NTC(10k)1%
7.Range of temperature display:0~70°C
8.Thread size:M30*1.5
9.Insulating condition: Normal environment
10.Size(mm): 66*52*82+20mm
11.Running program: Set per 1 week as a cycle
12.Maximum route:4.5mm

HY368/HY368-WIFI ZigBee
(work with control box for boiler Optional)
1.Power: 2*AA* 1.5V alkaline batteries
2.Maximum current:90mA
3.Working temperature:-10~60°C
4.Display accuracy:0.5°C
5.Default range of temperature adjustment:5~35°C
6.Probe sensor: NTC(10k)1%
7.Range of temperature display:0~70°C
8.Thread size:M30*1.5
9.Insulating condition: Normal environment
10.Size(mm):66*52*82+20mm
11.Running program: Set per 1 week as a cycle
12.Maximum route:4.5mm

HY10RT/HY369-WIFI ZigBee
(work with control box for boiler Optional)
1.Power: 3* AA* 1.5V alkaline batteries
2.Maximum current:90mA
3.Working temperature:-10~60°C
4.Display accuracy:0.5℃
5.Default range of temperature adjustment:5~35°C
6.Probe sensor: NTC(10k)1%
7.Range of temperature display:0~70°C
8.Thread size:M30*1.5
9.Insulating condition: Normal environment
10.Size(mm):66*52*82+20mm
11.Running program: Set per 1 week as a cycle
12.Maximum route:4.5mm
Wireless Heating Thermostat

HY02B05RF (different receiver optional)


1.Used for electric floor heating, infrared heater
2.Wireless control
3.Weekly programmable
4.Button
5.Color:black,white
6.Backlight:blue,white
7.Frequency:433MHz/470MHz
8.Power Supply:2 AA* 1.5V alkaline batteries
9.Set Point Range: 5~35°C
10.Size: 86 *86*25mm
11.Accuracy: ±0.5°C

HY01RF-P ( different receiver optional)


1.Used for electric floor heating, infrared
heater
2.Wireless control 3.Weekly programmable
4.LCD touch screen
5.Color:black,white
6.Backlight:blue,white
7.Frequency:433MHz/470MHz
8.Power Supply:2 AA* 1.5V alkaline batteries
9.Set Point Range: 5~35°C
10.Size: 130 *90*27mm
11.Accuracy: ±0.5°C

HY06RF ( different receiver optional)


1.Used for gas wall-hung boiler heating/electric
floor heating, infrared heater 2.Weekly programmable
3.Backlight:blue,white
4.Contact capacity:5Amp/16A(electric heating)/3A
(water heating)
5.Power Supply:2 AA* 1.5V alkaline batteries
6.Set Point Range: 5~35°C
7.Size: 86*86*27mm
8.Accuracy: ±0.5°C

HY05RF ( different receiver optional)


1.Used for electric floor heating, infrared
heater
2.Wireless control 3.Weekly programmable
4.LCD touch screen
5.Color:black,white
6.Backlight:blue,white
7.Frequency:433MHz/470MHz
8.Power Supply:2 AA* 1.5V alkaline batteries
9.Set Point Range: 5~35°C
10.Size: 130 *90*27mm
11.Accuracy: ±0.5°C

HY09RF / HY09RF-WIFI ( different receiver optional)


1.Used for electric floor heating, infrared heater
2.Wireless control 3.Weekly programmable
4.LCD touch screen
5.Color:black,white
6.Backlight:blue,white
7.Frequency:433MHz/470MHz
8.Power Supply:4 AAA* 1.5V alkaline batteries
9.Set Point Range: 5~35°C
10.Size: 130 *90*25mm
11.Accuracy: ±0.5°C
12. WIFI Control (Optional)
Underfloor Heating
Thermostat / WIFI / RS485

HY02B05 / HY02B05-WIFI
1.Used for electric floor heating,infrared heater or water
floor heating/manifold/valve 2.Weekly programmable
3.Backlight:White, Blue
4.Load current: 16A(electric heating)
3A (Water heating)
5.Power Supply: AC200-240V /110V /24V
6.Set Point Range: 5~35 °C
7.Accuracy: ±0.5°C
8.WIFI Control (Optional)

HY03-1 / HY03-1-WIFI
1.Used for electric floor heating,infrared heater or water
floor heating/manifold/valve 2.Weekly programmable
3.Backlight:White, Blue
4.Load current: 16A(electric heating)
3A (Water heating)
5.Power Supply: AC200-240V /110V /24V
6.Set Point Range: 5~35 °C
7.Accuracy: ±0.5°C
8.WIFI Control (Optional)

HY03-2 / HY03-2-WIFI
1.Used for electric floor heating,infrared heater or water
floor heating/manifold/valve 2.Weekly programmable
3.Backlight:White, Blue
4.Load current: 16A(electric heating)
3A (Water heating)
5.Power Supply: AC200-240V /110V /24V
6.Set Point Range: 5~35 °C
7.Accuracy: ±0.5°C
8.WIFI Control (Optional)

HY03-4 / HY03-4-WIFI
1.Used for electric floor heating,infrared heater or water
floor heating/manifold/valve 2.Weekly programmable
3.Backlight:Black
4.Load current: 16A(electric heating)
3A (Water heating)
5.Power Supply: AC200-240V /110V /24V
6.Set Point Range: 5~35 °C
7.Accuracy: ±0.5°C
8.WIFI Control (Optional)
Underfloor Heating Thermostat
WIFI / RS485

HY02B05 / HY02B05-WIFI
1.Used for electric floor heating,infrared heater or water
floor heating/manifold/valve 2.Weekly programmable
3.Backlight:White, Blue
4.Load current: 16A(electric heating)
3A (Water heating)
5.Power Supply: AC200-240V /110V /24V
6.Set Point Range: 5~35 °C
7.Accuracy: ±0.5°C
8.WIFI Control (Optional)

HY08-1 / HY08-1-WIFI
1.Used for electric floor heating,infrared heater or water
floor heating/manifold/valve 2.Weekly programmable
3.Backlight:White, Blue
4.Load current: 16A(electric heating)
3A (Water heating)
5.Power Supply: AC200-240V /110V /24V
6.Set Point Range: 5~35 °C
7.Accuracy: ±0.5°C
8.WIFI Control (Optional)

HY08-2 / HY08-2-WIFI
1.Used for electric floor heating,infrared heater or water
floor heating/manifold/valve 2.Weekly programmable
3.Backlight:Black
4.Load current: 16A(electric heating)
3A (Water heating)
5.Power Supply: AC200-240V /110V /24V
6.Set Point Range: 5~35 °C
7.Accuracy: ±0.5°C
8.WIFI Control (Optional)

HY08-3 / HY08-3-WIFI
1.Used for electric floor heating,infrared heater or water
floor heating/manifold/valve 2.Weekly programmable
3.Backlight:Black
4.Load current: 16A(electric heating)
3A (Water heating)
5.Power Supply: AC200-240V /110V /24V
6.Set Point Range: 5~35 °C
7.Accuracy: ±0.5°C
8.WIFI Control (Optional)

HY08-4 / HY08-4-WIFI
1.Used for electric floor heating,infrared heater or water
floor heating/manifold/valve 2.Weekly programmable
3.Backlight:White, Blue
4.Load current: 16A(electric heating)
3A (Water heating)
5.Power Supply: AC200-240V /110V /24V
6.Set Point Range: 5~35 °C
7.Accuracy: ±0.5°C
8.WIFI Control (Optional)
Underfloor Heating Thermostat
WIFI / RS485

HY603 WE/HY603 WE WiFi


1.Power: 90-240Vac 50/60HZ
2.Range of temperature display::0~40°C
3.Display accuracy::0.5°C
4.Insulating condition: Normal environment
5.Probe sensor::NTC(10k)1%
6.Running program: Set per 1 week as a cycle
7.Contact capacity::3A/250V(WW);16A/250V(WE)
8.Output: Switch relay
9.Working environment temperature::0~90°C
10.Installation: Wall mounted or on battery seat
11.Range of temperature adjustment::5~35°C
12.Size(mm):86*86*27

HY603 WE /HY603 WE WiFi


1.Power: 90-240Vac 50/60HZ
2.Range of temperature display::0~40°C
3.Display accuracy::0.5°C
4.Insulating condition: Normal environment
5.Probe sensor::NTC(10k)1%
6.Running program: Set per 1 week as a cycle
7.Contact capacity::3A/250V(WW);16A/250V(WE)
8.Output: Switch relay
9.Working environment temperature::0~90°C
10.Installation: Wall mounted or on battery seat
11.Range of temperature adjustment::5~35°C
12.Size(mm):86*86*27

HY312/HY312-WIFI
1.Used for electric floor heating,infrared heater or water
floor heating/manifold/valve 2.Weekly programmable
3.Backlight:Black
4.Load current: 16A(electric heating)
3A (Water heating)
5.Power Supply: AC200-240V /110V /24V
6.Set Point Range: 5~35°C
7.Accuracy: ±0.5°C
8.WIFI Control (Optional)

HY609/HY609-WIFI
1. Power: 90-240VAC 50/60Hz
2. Range of temperature display:5-35℃
3. Accuracy:±0.5℃
4. Insulating condition: Normal environment
5. Probe sensor: NTC(10k)1%
6. Running program: Set per 1 week as a cycle
7. Contact capacity: 3A/250V(WW); 16A/250V(WE)
8. Output: switch relay
9. Working environment temperature: 0-90℃
10. Installation: wall mounted
11. Size: 86*86*11 mm, Standard European box
12. Colorful logo light
13. WIFI Control (Optional)
Gas Boiler Thermostat
HY09BW ( WIFI optional)
1.Used for gas wall-hung boiler heating
2.Weekly programmable
3.Large lcd display screen
4.Color:black,white
5.Backlight:blue,white
6.Power Supply:2 AA* 1.5V alkaline batteries
WIFI Power Supply: AC230V
7.Set Point Range: 5~35°C
8.Size: 130 *90*25mm
9.Accuracy: ±0.5°C
10.Type:Dry Contact

HY08BW
1.Used for gas wall-hung boiler heating
2.Weekly programmable
3.Large lcd display screen
4.Color:black,white
5.Backlight:blue,white
6.Power Supply:2 AA* 1.5V alkaline batteries
7.Set Point Range: 5~35°C
8. Size: 86*86*30mm
9. . Accuracy: ±0.5°C
.
10.Type:Dry Contact.

HY01BW
1.Used for gas wall-hung boiler heating
2.Weekly programmable
3.LCD touch screen
4.Color:black,white
5.Backlight:blue,white
6.Power Supply:2 AA* 1.5V alkaline batteries
7.Set Point Range: 5~35°C
8.Size: 130 *90*27mm
9.Accuracy: ±0.5
.
10.Type:Dry Contact.

HY04BW
1.Used for gas wall-hung boiler heating
2.Weekly programmable
3.Large lcd display screen
4.Color:black,white
5.Backlight:blue,white
6.Power Supply:2 AA* 1.5V alkaline batteries
7.Set Point Range: 5~35°C
8.Size: 140*91*27mm
9.Accuracy: ±0.5°C
.
10.Type:Dry Contact.

HY06BW
1.Used for wall-hung boiler heating
2.Weekly programmable
3.Large lcd display screen
4.Color:white
5.Backlight:blue,white
6.Power Supply:2 AA* 1.5V alkaline batteries
7.Set Point Range: 5~35°C
8.Size: 86*86*27mm
9.Accuracy: ±0.5°C
.
10.Type:Dry Contact.
More Heating Thermostats
Different Standard Socket
HY02TP / HY02TP-WIFI
1.Used for electric floor heating,infrared heater
2.Weekly programmable
3.Operating voltage: AC200-240V /110V
4.Load (Max): 16A 3000W – Resistive load
5.Operating Temperature: -10°C ~ 70°C.
6.Temperature Control range: 5°C ~30°C
7.Precision:±0.5°C
8.Measuring period: 10 S
9. WIFI Control (Optional)

HY02TPR/HY02TPR-WIFI
1.Used for electric floor heating,infrared heater
2.Weekly programmable
3.Operating voltage: AC200-240V /110V
4.Load (Max): 16A 3000W – Resistive load
5.Operating Temperature: -10°C ~ 70°C.
6.Temperature Control range: 5°C ~30°C
7.Precision:±0.5°C
8.Measuring period: 10 S

HY02TPA
1、Voltage:110vac 50Hz/60Hz or 240vac 50Hz/60Hz
2、Max. load output:10A
3、Display resolution:0.5℃/1°F
4、Display range:0--70℃/32F--158°F
5、Control precision:±0.5°C/±1°F
6、Control range:1℃--70℃/34°F--158°F
7、Temperature sensor: one NTC, length 2m; two NTC
(optional)
8、Input power wire:1.5m
9、Output signal: one temperature control, buzzer alarm;
output wire length 0.3cm

HY02DB/HY02DB-WiFi
1.Power:230Vac 50/60HZ
2.Probe Sensor:NTC(10k)1%
3.Current:10A
4.Limit temperature range:1~70°C
5.Default setting temperature range:5~35°C
6.Max. control accuracy:±0.5°C

HY02TP / HY02TP-WIFI With External Sensor


1.Used for electric floowr heating,infrared heater
2.Weekly programmable
3.Operating voltage: AC200-240V /110V
4.Load (Max):16A 3000W - Resistive load
5.Operating Temperature: -10℃~70°C
6.Temperature Control range: 5°C~30°C
7.Precision:±0.5°C
8.Measuring period:10 S
9.WIFI Control (Optional)