1 System Wiring 2 Installation

Scan the QR code to view the


installation and wiring video.

L + 284 mm Steps:
Fix each pedestal Cable Hole: 1. Get ready for installation with tools and accessories.
130 mm with 6 expansion 226 mm × 84 mm
84 mm bolts of M12 × 150 2. Choose a proper installing place. Put 6 expansion bolts for each pedestal.
Steps: 3. Place the pedestals on the ground and pull out the cables for wiring.
1. Draw a central line on the installation surface of the left or 4. Fix each pedestal with screws.
Main Switch Main Switch right pedestal.
Power Supply HIgh Voltage Power Supply
2. Draw other parallel lines for installing the other pedestals.

272 mm
Sub Access Low Voltage Sub Access
Low Voltage The distance between the nearest two lines is L + 284 mm.
Control Board Control Board L represents the lane width.
L 3. Slot on the installation surface and dig installation holes
according to the hole position.
20 mm
4. Bury cables. Each lane buries 1 network cable, 1 high voltage
cable and 1 low voltage cable. For details, refer to the system
wiring diagram. 207 mm Lane Width

1496 mm

837 mm
130 mm 777 mm

DS-K3B631TX Series High voltage: AC power input


50 mm

Swing Barrier Low voltage: interconnecting cable (communication cable


and 24 V power cable) and network communication cable.
The supplied interconnecting cable length is 3 m.
The suggested inner diameter of the low voltage conduit is
larger than 30 mm.
Quick Start Guide Main Access Main Access

1005 mm
Control Board Control Board If you want to bury both of the AC power cord and the low
voltage cable, the two cables should be in separated conduits

862 mm
to avoid interference.
If more peripherals are required to connect, you should
UD30184B increase the conduit diameter or bury another conduit for
the external cables.
The external AC power cord should be double-insulated.
The CAT6e network cable is suggested.

162 mm

162 mm
Entrance

If the installation area is close to the wall, make sure the distance
between the pedestal and the wall should be more than 20 mm, 1496 mm
or you cannot open the pedestal's top panel.

3 Wiring Main User Extended Sub User Extended


Interface Board Interface Board 100 ~ 260 VAC
Power Input
©2022 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.
About this Manual
The Manual includes instructions for using and managing the Product. Pictures, charts, Circuit Breaker Circuit Breaker
images and all other information hereinafter are for description and explanation only.
The information contained in the Manual is subject to change, without notice, due to DIP Switch
firmware updates or other reasons. Please find the latest version of this Manual at the
Hikvision website (https://www.hikvision.com/). 24 V Power Cable 24 V Power Cable SCL
Reserved Power Supply Power Supply
SDA
Please use this Manual with the guidance and assistance of professionals trained in Interface Interface
supporting the Product. CASE1 CASE1 Network
Trademarks Sub User Extended Sub User Extended GND
Event Input GND
Reserved Cable Network
and other Hikvision’s trademarks and logos are the properties of Hikvision in Interface Board Interface Board CASE2 CASE2
Cable
various jurisdictions. GND GND
Interconnecting Cable 232RX RS-232 232RX RS-232
Other trademarks and logos mentioned are the properties of their respective owners. 3 interconnecting cables are contained in the package:
Disclaimer
Interconnecting Cable Interconnecting Cable Interface 232TX (Port 4) 232TX (Port 4) PoE PoE
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE Interface Interface 12V 12V
24 V Power Cable 1. 24 VAC Power Interconnecting Cable
PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED Circuit Breaker Circuit Breaker BZ BZ 24 V Power Cable 24 V Power Cable
“AS IS” AND “WITH ALL FAULTS AND ERRORS”. HIKVISION MAKES NO WARRANTIES, Interface W1 W1
(Main Lane) (Main Lane) W0 Wiegand W0 Wiegand
EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, GND GND The 24 VAC Power Interconnecting Cable of 12AWG is placed Communication Cable Communication Cable
SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE GND GND
PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU NC1
inside of the right/middle pedestal at the exit direction. Communication Cable Communication Cable
FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, COM1
AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, NO1 2. Lane Control Interconnecting Cable
OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER NC2 Alarm Output
BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, COM2
OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION NO2 The gray CAT5e cable is used for connection between main lane Sub User Main User Sub User Main User
HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS. NC3 control board and sub lane control board, and is placed inside
YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR INHERENT COM3 Extended Extended Extended Extended
SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL NO3
Lock of the package of the right/middle pedestal. You need to plug Interface Interface Interface Interface
NC4
OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK, COM4 the cable into the gray adaptor. Board Board Board Board
HACKER ATTACK, VIRUS INFECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, NO4
HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.
YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND 24VOUT1 24VOUT1 3. Access Control Interconnecting Cable
YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE GND GND
24VOUT2 24 VDC Output 24VOUT2 24 VDC Output
APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A GND GND The black CAT5e cable is used for connection between main
MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING Sub Lane Main Sub Lane Main
WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA 12VOUT1 12VOUT1 access control board and sub access control board, and is
PROTECTION AND OTHER PRIVACY RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY GND 12 VDC Output GND 12 VDC Output placed inside of the package of the right/middle pedestal. You Control Lane Control Lane
PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS 12VOUT2 12VOUT2 Board Control Board Control
OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR GND GND need to plug the cable into the black adaptor. Board Board
BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR 5VOUT1 5VOUT1
EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS GND
5VOUT2 5 VDC Output
GND
5VOUT2 5 VDC Output
ABUSES. Entrance GND GND
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, Main User Extended Main User Extended
THE LATTER PREVAILS. Interface Board Interface Board BTN BTN
Exit Button Exit Button
Data Protection GND GND
Sub Main Sub Main
During the use of device, personal data will be collected, stored and processed. To ALARM IN
protect data, the development of Hikvision devices incorporates privacy by design GND Fire Input Access Access Access Access
principles. For example, for device with facial recognition features, biometrics data is Control Control Control Control
stored in your device with encryption method; for fingerprint device, only fingerprint Board Board Board Board
template will be saved, which is impossible to reconstruct a fingerprint image.
As data controller, you are advised to collect, store, process and transfer data in 232RX 232TX 485- 485+ 232RX 232TX 485- 485+
accordance with the applicable data protection laws and regulations, including without
limitation, conducting security controls to safeguard personal data, such as,
implementing reasonable administrative and physical security controls, conduct periodic RS-232 RS-485 RS-232 RS-485
reviews and assessments of the effectiveness of your security controls. (Port 2) (Port 5) (Port 2) (Port 5)

Left Middle Right


4 Wiring Diagram 5 DIP Switch Description Regulatory Information Safety Instruction
FCC Information
Please take attention that changes or modification not expressly
CASE1
approved by the party responsible for compliance could void the
Reserved GND
CASE2 user’s authority to operate the equipment. !Warning
GND The DIP swtich is on the main user extended interface board.
FCC compliance: This equipment has been tested and found to In the use of the product, you must be in strict compliance
232RX
232TX RS-232 comply with the limits for a Class B digital device, pursuant to part with the electrical safety regulations of the nation and
PWR 15 of the FCC Rules. These limits are designed to provide region.
12V
BZ Beep reasonable protection against harmful interference in a residential Do not connect several devices to one power adapter as
Wiegand
W1
W1 Wiegand installation. This equipment generates, uses and can radiate radio adapter overload may cause over-heat or fire hazard.
W0
GND W0 Card Reader Work Mode frequency energy and, if not installed and used in accordance with If smoke, odors or noise rise from the device, turn off the
GND
GND the instructions, may cause harmful interference to radio power at once and unplug the power cable, and then
ERR Normal Mode Study Mode
communications. However, there is no guarantee that interference please contact the service center.
OK will not occur in a particular installation. If this equipment does The socket-outlet shall be installed near the equipment
cause harmful interference to radio or television reception, which and shall be easily accessible.
can be determined by turning the equipment off and on, the user is 1. Do not ingest battery. Chemical burn hazard!
encouraged to try to correct the interference by one or more of the 2. This product contains a coin/button cell battery. If the
following measures: coin/button cell battery is swallowed, it can cause severe
—Reorient or relocate the receiving antenna. internal burns in just 2 hours and can lead to death.
—Increase the separation between the equipment and receiver. 3. Keep new and used batteries away from children.
—Connect the equipment into an outlet on a circuit different from 4. If the battery compartment does not close securely,
24VOUT1 that to which the receiver is connected. stop using the product and keep it away from children.
24 V Output GND —Consult the dealer or an experienced radio/TV technician for
24VOUT2
GND help. 5. If you think batteries might have been swallowed or
This equipment should be installed and operated with a minimum placed inside any part of the body, seek immediate
12 V Output
12VOUT1
GND Keyfob Paring Mode distance 20cm between the radiator and your body. medical attention.
12VOUT2 FCC Conditions 6. CAUTION: Risk of explosion if the battery is replaced by
GND
Exit: This device complies with part 15 of the FCC Rules. Operation is an incorrect type.
5VOUT1 Enable Keyfob Paring Mode Disable Keyfob Paring Mode 7. Improper replacement of the battery with an incorrect
RS-232:Port 2, Port 4 5 V Output GND subject to the following two conditions:
RS-485:Port 5 5VOUT2 1. This device may not cause harmful interference. type may defeat a safeguard (for example, in the case of
GND
2. This device must accept any interference received, including some lithium battery types).
PWR
Exit Button
BTN
GND
Exit
Button GND
interference that may cause undesired operation. 8. Do not dispose of the battery into fire or a hot oven, or
Peripheral mechanically crush or cut the battery, which may result in
Sub User Extended Device
Interface Board
485+ This product and - if applicable - the supplied an explosion.
See Wiring Diagram of 485+ 485- accessories too are marked with "CE" and comply 9. Do not leave the battery in an extremely high
Right Pedestal for therefore with the applicable harmonized European
Sub User Extended 485- temperature surrounding environment, which may result
standards listed under the RE Directive
Interface Board 2014/53/EU, the EMC Directive 2014/30/EU, the in an explosion or the leakage of flammable liquid or gas.
232RX 232TX 485- 485+
232TX PWR
GND Peripheral RoHS Directive 2011/65/EU. 10. Do not subject the battery to extremely low air
232RX
232RX Device 2006/66/EC (battery directive): This product pressure, which may result in an explosion or the leakage
232TX
contains a battery that cannot be disposed of as of flammable liquid or gas.
DIP Switch unsorted municipal waste in the European Union. 11. Dispose of used batteries according to the instructions
See the product documentation for specific
SCL battery information. The battery is marked with ! Caution
SDA
CASE1
Reserved Event Input
6 Quick Operation this symbol, which may include lettering to
indicate cadmium (Cd), lead (Pb), or mercury
Do not drop the device or subject it to physical shock, and
do not expose it to high electromagnetism radiation. Avoid
Event Input GND (Hg). For proper recycling, return the battery to
CASE2
The device can be configured via local settings, PC web, mobile web, and your supplier or to a designated collection point. the equipment installation on vibrations surface or places
GND
Event Input For more information see: www.recyclethis.info subject to shock (ignorance can cause equipment
232RX
RS-232 clint software. damage).
232TX
12V PWR Lcal Quick Start 2012/19/EU (WEEE directive): Products marked Do not place the device in extremely hot (refer to the
BZ Beep 1. Hotspot Settings with this symbol cannot be disposed of as specification of the device for the detailed operating
Wiegand
W1
W0 W1 Wiegand When hotspot is enabled, you can connect mobile phone to the device
unsorted municipal waste in the European Union. temperature), cold, dusty or damp locations, and do not
GND W0 Card Reader
hotspot for configuration.
For proper recycling, return this product to your expose it to high electromagnetic radiation.
GND local supplier upon the purchase of equivalent
+ - GND Exposing the equipment to direct sun light, low ventilation
Entrance: NC1 12 V ERR 2. Local Activation new equipment, or dispose of it at designated or heat source such as heater or radiator is forbidden
RS-232:Port 2, Port 4 COM1 collection points. For more information see:
RS-485:Port 5 Alarm Output NO1
OK On the Activate Device page, create a password and confirm the password. (ignorance can cause fire danger). The device cover for
NC2
3. Set application mode. www.recyclethis.info indoor use shall be kept from rain and moisture.
See Wiring Diagram of COM2 Alarm Output
Right Pedestal for NO2 4. Set wired network parameters. Exposing the equipment to direct sun light, low ventilation
Main User Extended
NC3
or heat source such as heater or radiator is forbidden
Interface Board 5. Privacy Settings
Main User Extended COM3 (ignorance can cause fire danger).
Interface Board NO3 Remain Open
Lock NC4
Select if you need to upload or save captured pictures. Please use a soft and dry cloth when clean inside and
COM4 6. Add keyfob. outside surfaces of the device cover, do not use alkaline
NO4
7. Add administrator. detergents.
24 V Output
24VOUT1
GND
Biometric recognition products are not 100% applicable to
24VOUT2 Configuration via PC Web anti-spoofing environments. If you require a higher
GND
Make sure the device is activated. Enter the device IP address in the address
security level, use multiple authentication modes.
12VOUT1 The serial port of the equipment is used for debugging
12 V Output GND bar of the web browser and press Enter to enter the login page. Scan the QR code to get the user only.
12VOUT2
GND Enter the device user name and the password. Click Login. manual for detailed informa�on. Wall Mounting: Install the equipment according to the
5VOUT1 instructions in this manual. To prevent injury, this
5 V Output GND Configuration via Mobile Web equipment must be securely attached to the floor/wall in
5VOUT2
GND
When the device hotpot is enabled, you can also scan the QR code and the
accordance with the installation instructions.
Fire Alarm Module Improper use or replacement of the battery may result in
Exit Button
BTN Exit login page will pop up.
GND Button hazard of explosion. Replace with the same or equivalent
ALARM IN Fire Alarm Enter the device user name and the password. Click Login. type only. Dispose of used batteries according to the
GND Input You can configure the turnsile basic parameters, keyfob settings, light instructions provided by the battery manufacturer.
Remain Open PWR
This bracket is intended for use only with equipped
GND Peripheral settings, network settings, access control settings and face parameters, etc.
RX Device devices. Use with other equipment may result in instability
232RX 232TX 485- 485+ 232RX TX causing injury.
Configuration via Client Software This equipment is for use only with equipped bracket. Use
232TX with other (carts, stands, or carriers) may result in
After downloading the client software, you can conduct device
485- PWR instability causing injury.
485+
GND Peripheral management, group management, person managment and access
RS-485- Device control management.
RS-485+