ESCORT ConsolePlus

(EA-SWP-PLUS)

User Manual
Ver. 3.1

Console Plus User Manual version 3.1 Page 1


Contents
1. Quick start Guide .................................................................................................................................. 3
2. Dependences ........................................................................................................................................ 4
3. Accessories ............................................................................................................................................ 4
4. Installation ............................................................................................................................................ 5
5. Introduction .......................................................................................................................................... 8
6. Main Menu .......................................................................................................................................... 10
7. Icons .................................................................................................................................................... 11
8. Tabs ..................................................................................................................................................... 11
9. Options (program settings) ................................................................................................................. 12
 General tab ..................................................................................................................................... 12
 View tab .......................................................................................................................................... 13
 Languages tab ................................................................................................................................. 14
10. Program........................................................................................................................................... 15
 Program Functions .......................................................................................................................... 17
11. Lock program settings ..................................................................................................................... 19
12. Template (Save / Load) ................................................................................................................... 19
13. Password protection ....................................................................................................................... 20
14. User defined settings ...................................................................................................................... 21
15. Download ........................................................................................................................................ 22
16. Graph .............................................................................................................................................. 23
 Mouse Zoom: .................................................................................................................................. 24
 Mouse Tool Tip: .............................................................................................................................. 24
17. Save/ save as ................................................................................................................................... 24
18. Auto-open PDF ................................................................................................................................ 25
19. Histogram ........................................................................................................................................ 25
20. Table ................................................................................................................................................ 26
21. Summary ......................................................................................................................................... 27
22. Bookmark ........................................................................................................................................ 28
23. MKT ................................................................................................................................................. 29
24. Multilink .......................................................................................................................................... 29
25. Battery Status.................................................................................................................................. 34
26. Print / Print-preview ....................................................................................................................... 34
27. Update ............................................................................................................................................ 34

Console Plus User Manual version 3.1 Page 2


Console Plus is new revolutionary software for new product line iMINI, iMINI USB PDF, xTag and all
future releases of Escort Verification Technologies/Cryopak Verification Technologies (EVT/CVT)
products. It has all features to program, download, view and analyze critical data.

1. Quick start Guide


ConsolePlus software currently supports following product range

Product Product code Type Total Sensor Sensor


Family No. of Location Type
Sensors
iMINI
MX-IN-S-8-L Multi-use 1 Internal NTC
(yellow case)
iMINI
MX-ST-S-8-L Single Use 1 Internal NTC
(yellow case)
iMINI
MX-OE-S-8-L Multi-use 1 External NTC
(yellow case)
iMINI One Internal &
MX-1E-S-8-L Multi-use 2 NTC
(yellow case) One External
iMINI
MX-2E-S-8-L Multi-use 2 Both External NTC
(yellow case)
iMINI
MX-HS-S-8-L Multi-use 2 Both Internal Digital sensor
(yellow case)
iMINI Two Internal & Digital sensor &
MX-HE-S-8-L Multi-use 3
(yellow case) One External NTC
iMINIUSB pdf
MS-ST-S-8 Single Use 1 Internal NTC
(Plug & Play)

All new products from EVT/CVT will be supported by ConsolePlus. Software has in-built auto update
feature, when a new release is available it will prompt user to upgrade to newest version. And with one
click it will be updated.

Console Plus User Manual version 3.1 Page 3


2. Dependences
ConsolePlus can be installed on following platforms
 Windows XP
 Windows 7
 Windows 8

Adobe reader (latest Version) must be installed on the computer. If not, user may encounter error
 in PDF generation
 Print
 Print preview
 Software crash

3. Accessories
 For all iMINI (yellow case) data loggers Type A to Mini-B USB cable is required to connect data
logger to the workstation

 iMINIUSB pdf data logger is Plug and Play data logger

Console Plus User Manual version 3.1 Page 4


4. Installation
Setup file can be downloaded from www.escortdataloggers.com for free
File name: ConsolePlusSetup.exe / ConsolePlusSetup.zip
I. When you get started you should try to install the following application file:

II. Once you have double clicked ConsolePlusSetup.exe file you will get the following Step
through Wizard:

Note: Version no. *.** is being updated regularly


III. Browse to select the location of installation, if it is necessary or leave as default

Console Plus User Manual version 3.1 Page 5


Click NEXT

Click NEXT

Console Plus User Manual version 3.1 Page 6


Click INSTALL to install the necessary drivers

Click INSTALL

Console Plus User Manual version 3.1 Page 7


Click FINISH to complete the installation process

5. Introduction

ConsolePlus icon is created and placed on desktop after the installation is completed.

Launch ConsolePlus

a. ConsolePlus *.** on top Left Corner, *.** denotes current version number
b. When the application is launched for first time, the application window will open OPTIONS window
and highlight in red text
c. A default directory for the data can be assigned here, once default directory is assigned, path
becomes black

Console Plus User Manual version 3.1 Page 8


d. Home page is displayed and
most of the tabs and
functions are greyed out.
User can do initial settings
at this stage or whenever
required by selecting
options.

e. Make sure to manually


check for updates before
proceeding to next step.

Refer to Step 27

Console Plus User Manual version 3.1 Page 9


6. Main Menu

Most of the functions are disabled initially, and will be highlighted


or available depending on if the data logger is plugged in or a file
is open.
User a sele t optio s a y ti e a d ha ge the fields

Open a previously saved file (target default directory)

Save downloaded data of a logger

Save downloaded data of a logger in different format


e.g. csv & txt

If multiple files are open and want to remove selected files


from the list

If multiple files are open and want to remove from list

Select to open Options window

Open a previously saved template, to program logger

Save a new template, based on new program settings

Create PDF from the open file, save in default directory

Print preview

Print

Manually check for available software updates

Console Plus User Manual version 3.1 Page 10


7. Icons

8. Tabs

Home: It display homepage


Program: Program settings of a programmed logger, or to program a logger
Graph: Graph view of downloaded data a logger or a file
Histogram: Histogram view of downloaded data a logger or a file
Table: data/readings of all sensors of downloaded data of a logger or a file
Summary: Summary view of downloaded data of a logger or a file

Console Plus User Manual version 3.1 Page 11


9. Options program settings
 General tab
a. Click options, either from MENU, File – Options or simply by clicking icon

b. By default opens General tab,

Displays Help window on right hand side of application if checked

If checked- auto download data from a logger as soon as logger is connected

If checked- downloaded data from a logger is auto-saved in default directory

If checked- data from a logger is auto-saved as txt file in default directory


If checked- data from a logger is auto-saved as CSV file in default directory

If checked- data from a logger is auto-saved as PDF file in default directory

If checked- saved PDF file will auto-open (adobe acrobat must be installed)

Can be selected Celsius or Fahrenheit

When data is multi-linked (actual time)

When data is multi-linked (from 1st reading)

User a usto ize A ti atio E ergy alue,


to calculate MKT

c. Select / de-select any of the available options from General tab (e.g. if auto download or auto save
required)

Console Plus User Manual version 3.1 Page 12


 View tab

In View Tab, Graph and Histogram color settings can be changed and set as required

Console Plus User Manual version 3.1 Page 13


 Languages tab

Six languages available to select from the list

Console Plus User Manual version 3.1 Page 14


10. Program

a. Plugin USB mini port to iMINI and connect the USB port into an available USB slot on workstation.
(USB 5pin Mini cable to USB)

b. ConsolePlus application will recognize the iMINI and will be available on left hand Logger / File
List pane

c. ConsolePlus application will display the serial number of iMINI and the alarm status. In
functions tab it will reach to GRAPH tab by default.

Connected logger- Communication port


number, Serial number and Alarm status

Open File- File location, Serial number


and Alarm status

Text Description Icon

LL If Low Low Alarm has triggered

L If Low Alarm has triggered

OK If no alarm has triggered

H If High Alarm has triggered


HH If High High Alarm has triggered

d. If the fu tio ta s are greyed out, li k do load i o fro the top

e. Select PROGRAM tab. All the previous program information of connected logger is displayed.

f. If logger has only one sensor or other sensor combination, the respected tabs are greyed out by
default. Software auto-detects the type of logger and display existing information
Logger with external sensor only (MX-OE-S-8-L) will appear on 1st tab and title will appear int/ext
temp. (NTC) Instead of Int. Temp (NTC)

Console Plus User Manual version 3.1 Page 15


PROGRAM TAB

Console Plus User Manual version 3.1 Page 16


 Program Functions

24

No. Details Read / write


1 Firmware version of connected logger, or the logger of saved file Read only
2 Enter Password, up to 8 numbers write only
3 Allow to read the logger without password
4 Allow to program the logger without password
5 Serial number of the logger Read only
6 Product code of the logger Read only
7 Memory size of the logger Read only
8 Trip number of the logger Read only
9 Temperature range of the logger Read only
10 Description Read / Write
11 Sensor Int temp. / ext temp / Humidity
12 High High Alarm threshold Read / Write
13 High Alarm threshold Read / Write
14 Low Alarm threshold Read / Write
15 Low Low Alarm threshold Read / Write
16 Sensor enable / disable Read / Write
17 Consecutive delay before alarm (1 – 254) Read / Write

Console Plus User Manual version 3.1 Page 17


18 Total delay before alarm (1 – 254) Read / Write
19 Interval between each reading (5 seconds to 17H:59M:59S) Read / Write
20 Start the logger at pre-defined date and time Read / Write
21 Select the start delay Read / Write
22 Show Alarms on the display Read / Write
23 Show temperature on the display Read / Write
24 Enable alarms, select / deselect, any or all Read / Write
25 Duration of the trip, can be user defined, or choose from list Read / Write
26 Memory used in previous trip Read only
27 Stop the logger at pre-defined time (if selected) Read / Write
28 Stop the logger after “ “ number of readings have been taken Read / Write
29 Enable stop button Read /Write
30 Battery status Icon Read only
31 Enable non-stop logging (not available for single use loggers) Read /Write(multi use)
32 Auto-reset enabled (not available for single use loggers) Read /Write(multi use)
33 Total time for the designated trip Read only

NOTE: Logger can be started by TIME / START button (immediate start or with delay) or with both
options enabled. Please select these settings carefully

And hit PROGRAM icon


g. A confirmation dialogue will appear for the final approval

h. After acceptance bottom left corner progress bar will progress and display 100%.

i. READY ill e o the LCD display of iMINI

Logger is ready to start logging, according to settings (timer or button) logger will start measuring
and recording the data.

Console Plus User Manual version 3.1 Page 18


11. Lock program settings

Adjust the necessary fields or program settings


for the next trip, (user can lock these settings if
more loggers need to be programmed
automatically (when connected). By clicking
icon , it will turn as and the locked fields
will be highlighted in PROGRAM tab in RED font
as shown
This function is only available for the same
product; product code must be similar for the
next logger to be auto-programmed

12. Template Save / Load

Program settings of a Data Logger can be saved as template and be used for future.

Save Template Program: User can save template from a data file (CVT) or from a connected logger. File
will be with extension *.xtp and saved at default location

Load Template Program: User can use previously save template (extension *.xtp). If loaded, program
will fill all the settings in the fields and will be displayed in Red color fonts (as above). Program lock icon
will be locked and program icon will be highlighted as soon as the logger is plugged in and can be
programmed with these saved settings

Console Plus User Manual version 3.1 Page 19


13. Password protection

In password protection, from one to eight numbers can be assigned during program, no alphabets are
accepted.

 Initially entire filed is blank and Allow RD / Allow WR are greyed out

 Allow RD / Allow WR will be available to select as soon as number is entered Pass R/W filed
If none of the options, Allow RD / Allow WR is selected, user has to enter password to Program /
Download data

 If Allow RD is selected during program, user can Download the data without password, but not
be able to Program

 If Allow WR is selected during program, user can Program the logger without password, but not
be able to Download the data

When logger is connected next time, ConsolePlus ask for a password depending on the option selected,

if Allow RD is selected during program, Read Without Password – READ button will be highlighted and
clickable. After the li k Do load utto ill e enabled and data can be downloaded manually by
li k or if Auto Do load is e a led
if Allow WR is selected during program, Write Without Password – WRITE button will be highlighted
a d li ka le. After the li k Progra ta ill e e a led

Console Plus User Manual version 3.1 Page 20


14. User defined settings

User can program the logger by selecting the list of pre-set no. of days from drop down list

Settings of 1 day to 60 day are available. Program will use full memory of the logger and set the time
interval between each reading accordingly

Console Plus User Manual version 3.1 Page 21


15. Download

a. Plug iMINI into the USB mini port and run the USB port into an available USB slot on workstation.

b. ConsolePlus will auto download (if checked in options)

c. Or user can always force the software to download by clicking icon

d. A progress bar will appear (left bottom corner)

e. Currently captured data or data of previous trip (if logger is displaying STOPPED) will be
downloaded and will render the graph immediately of the data

f. Download is also possible even if there is no data in the logger or new mission / trip has not started
and device is displaying READY. In some events previous trip data is available.

This helps if logger is a ide tly progra ed a d has t yet started, user has a ha e to re o er
the data

g. Download option will be disabled if logger is password protected and Allow RD is disabled.

Console Plus User Manual version 3.1 Page 22


16. Graph

 Graph tab will auto open after a download or a previously saved file is open
 X-axis is always date & time axis
 Y-axis is Temperature or Temperature/Humidity (depending on the data logger type)
 If the logger is with one sensor, graph will display different colors in background at respective
alarm range
 If the logger is multi-sensor, by default background is light blue (as above), settings can always
be changed at any time
Options  View Tab
 Graph Legend area has all the sensors available with respective information (S.No. & sensor)
 User can click each or any of these bullets to select / deselect that particular sensor in the graph.
Graph will change accordingly in real time

Console Plus User Manual version 3.1 Page 23


 If only one sensor at a given time is selected, the background will display colors based on alarm
conditions (HH, H, L, LL)

High High

High

Low

Low Low

Colored Background available


When one sensor selected

 Mouse Zoom:
User can select some area in graph and it will zoom to the range for closer look

 Mouse Tool Tip:


Hovering the mouse over the graph will show the reading no., time and data information in entire graph

17. Save/ save as


If AUTO SAVE is checked in options, the data file will be saved automatically in default folder or user can
manually save the data from the icon or from

MENU  File  Save/save as

Save: by default extension *.CVT in default folder


Save as: user can choose extension from drop down list *.CVT, *.TXT, *.CSV
Or as PDF file, by default (PDF icon ) saves in default directory

Console Plus User Manual version 3.1 Page 24


Above options can be selected to auto save different file types, this feature helps users to not to lose
the data.

18. Auto-open PDF


ConsolePlus generates PDF automatically if selected in options  auto sa e PDF .
If the next option  auto ope PDF is e a led, ge erated PDF ill ope auto ati ally as soo as the
logger is connected and data is downloaded.

Adobe PDF applications must be installed on the computer. If Adobe PDF is not installed, user may
receive a message during installation of ConsolePlus. If not installed, option  auto ope PDF ill e
permanently greyed out / disabled. Until the Adobe PDF is installed

19. Histogram
Analytical view of the data is displayed

Console Plus User Manual version 3.1 Page 25


20. Table
All the data from the logger (from START to FINISH of the current/last trip) can be viewed here. Scroll
down to view all the data of the logger. Readings are in colored fonts according to alarm settings
triggered to make them easier to understand and detect.

Below LOW LOW alarm


Dark Blue color

Readings within specification


GREEN color

Below HIGH alarm


Light RED color

Above HIGH HIGH alarm


Below LOW alarm Dark RED color
Light BLUE color

Console Plus User Manual version 3.1 Page 26


21. Summary
Detailed summary of the trip and basic information
of the logger and all sensors can be viewed here

Basic Summary

Internal Temp (Digital)


Or
NTC (or Ext Left)
(if not with Humidity sensor)

Internal Humidity (Digital)

External Temp NTC


(Ext Right)
1M Grey Cable

Console Plus User Manual version 3.1 Page 27


22. Bookmark
A Bookmark displays a MARKED
reading, users can mark a
reading during the logging by
briefly holding START button on
the logger for 3-5 seconds,
MARKED text displayed on the
LCD display of the logger screen
for few seconds, and that
reading is marked with time
stamp

Once data is downloaded

Graph view, a STAR is placed at


the time and reading

Bookmarked readings

Table view, bookmarked readings are


highlighted with grey background

Bookmarked readings

Console Plus User Manual version 3.1 Page 28


23. MKT

User can view Mean Kinetic Temperature; on summary tab.


Mean kinetic temperature (MKT) is a simplified way of expressing the overall effect of temperature
fluctuations during storage or transit of perishable goods

Activation energy (typically within 60–100 kJ·mol-1 for solids or liquids), ConsolePlus allow users to
customize activation energy. This option is available in Options / settings on general tab

24. Multilink

User is allowed to link multiple files (with extension CVT) by selecting with mouse or by pressing shift
and selecting individual files. Compare the results with different options.
I. Compare trip data based on actual date/time of each reading
II. Compare trip data from different date/time period(s)
The linked files also can be saved into TXT and CSV format for further evaluation or to print. Data from
multiple files also reflects in Graph, Histogram, Table and Summary
I. Compare trip data based on actual date/time of each reading

Console Plus User Manual version 3.1 Page 29


Console Plus User Manual version 3.1 Page 30
Console Plus User Manual version 3.1 Page 31
II. Compare trip data from different date/time period(s)

Console Plus User Manual version 3.1 Page 32


Console Plus User Manual version 3.1 Page 33
25. Battery Status

Logger s attery status is dire tly displayed o progra ta . Soft are a dete t the status a d report
with icon

OK battery

Low battery

If the data logger has low battery, low battery symbol is displayed on LCD of the data logger (if logger
supports LCD)

26. Print / Print-preview

Print / Print-preview functions are available in ConsolePlus, when a file is open or logger is connected
and downloaded. Available in main menu and icons are at the top of the application

27. Update

ConsolePlus software will check for updates automatically and will display a confirmation message
when application is launched.

Also it can be easily updated manually fro MENU ta , y sele ti g he k for update . So user eed ot
to download a separate file all the time.

For more information about product and applications please contact


[email protected]

Console Plus User Manual version 3.1 Page 34