STEPS DESCRIPTION FORMULA VALUES UNITS
DATA
Load on Column 109 kN
Moment about z or x axis 20 kNm
Compressive Strength of Concrete (fck) 30 N/mm2
Grade of Steel Fe 500 N/mm2
Length of Column 4000 mm
End Condition BOTH ENDS FIXED
Depth/Breadth 1
Diameter of Main Rod 12 mm
Area of Rods 113.04 mm2
Cover 40 mm
Reinforcement Distribution 4 sides
STEP 1
CALCULATION OF GROSS AREA
Breadth of Column 300 mm
Depth of Column 300 mm
Gross Area 90000 mm2
STEP 2
CALCULATION OF % OF TENSION REINFORCEMENT
Pu/fckbd 0.04
Mu/fckbd2 0.025
d'= cover+D/2+Dt/2 49
d'/D 0.16
REFERING CHART 50 FROM DESIGN AIDS SP 16
P/fck 0.04
% of Tension Reinforcem 1.2
% of Tension Reinforcement 1080 mm2
Min Reinforcement 0.8% of Gross Area 720 mm2
Max Rein forcement 4% of Gross Area 3600 mm2
Provided Reinforcement 0 SAFE
No.of Rods 7
Provide 8 nos of 16mm rods ON FOUR SIDES
STEP 3
CHECK FOR ECCENTRICITY
emin= L/500+D/30 26.7 mm
emin= L/500+B/30 26.7 mm
emin 20 mm
Eccentricity of Coulmn 26.7 mm
STEP 4
CALCULATION OF TRANSVERSE REINFORCEMENT
Diametre of Lateral ties
Diameter of Transverse rods 1/4*Dia of Longitudial rod 3 mm
Minimum Diameter of Transverse rods 6 mm
Diameter of Lateral Ties 6 mm
Spacing of Lateral ties
Minimum of Breadth or Depth of Column 300 mm
16*Dia of Min Logitudinal Reinforcement 192 mm
300mm 300 mm
SPACING OF LATERAL TIES 192 mm