SSI-ICP-08-2016

Multitype ICP Emission Spectrometer

ICPE-9000 Series
Supplies and Maintenance Parts
Contents
Sample Introduction .................................................................................................. 3

Torches ................................................................................................................ 3
Nebulizers/Tubing ................................................................................................ 6
Spray Chambers .................................................................................................. 7
Drains .................................................................................................................. 9
Orifices ............................................................................................................. 10
Miscellaneous .................................................................................................... 10

ICPE-9000 ................................................................................................................. 12

Main unit .......................................................................................................... 12


Plasma Stand .................................................................................................... 12
Argon Supply .................................................................................................... 14
Vacuum System ................................................................................................. 15

ASC-6100F ................................................................................................................ 16

Maintenance Parts ............................................................................................ 16


Sample Cups / Accessories ................................................................................ 16

Peripheral Equipment ............................................................................................. 17


Software ........................................................................................................... 17
Auto-Samplers .................................................................................................. 17
High-Sensitivity Analysis ..................................................................................... 18
Peristaltic Pumps ............................................................................................... 18
Chillers/Cooling Kits .......................................................................................... 20

Chemical Compatibility Charts ................................................................................. 21


ASC-6100F......................................................................................................... 21
Organic Solvents ............................................................................................... 22

Sample System Configurations ................................................................................ 23


Sample Introduction
See System Configurations chart on page 21.

Torches

P/N Part Name Remarks External Appearance

211-81448-00 Mini Torch Mini torch (comes standard)

Used when introducing an undiluted


solution of a sample where the base
204-74323-00 High Salts Torch
element is on the percent order of
concentration

204-70272-00 Standard Torch Used with non-volatile organics

Used when analyzing organic solvent


Volatile Organics
204-77296-00 samples that are difficult to inject into
Torch
the plasma

Semi-Demountable Used for samples in HF


220-95356-20
Torch (see replacement parts – page 4)

Used for samples in HF


205-09627-01 Demountable Torch
(see replacement parts – page 5)

3
Back to Contents
Order at 800-477-1227, x2 or online at store.shimadzu.com
Semi-Demountable Type

Semi-Demountable
220-95356-20 Used for samples in HF
Torch

Semi-Demountable
220-95356-30
Torch Body

Semi-Demountable
220-95356-31
Torch Adaptor

Tapered Alumina
220-95356-32
Injector 1.5mm

220-95356-33 Joint Clip B14-Nickel

GazFit Connectors for


220-95356-34 4mm OD side arm
(PKT4)

4
Back to Contents
Order at 800-477-1227, x2 or online at store.shimadzu.com
Demountable Type

205-09627-01 Demountable Torch Used for samples in HF

Plasma Torch
205-09631-00
Sheathing

205-09630-00 Sapphire Chip 1.8 mm

205-09632-01 Injector Tube

036-11213-00 O-Ring, 4DP12

5
Back to Contents
Order at 800-477-1227, x2 or online at store.shimadzu.com
Nebulizers
Part Name P/N Remarks External Appearance
046-00092-20 Standard Nebulizer
Includes:
046-00092-09 Connector, QSM
046-00092-10 Tube adaptor, 0735
Nebulizer, 10UES
037-61113-01 Clamp, SNP-1

046-00092-18 Take-up tube ASSY, NFTS-075

046-00092-21 For small sample amounts


Includes:
046-00092-09 Connector, QSM
046-00092-10 Tube adaptor, 0735
Nebulizer, 07UES
037-61113-01 Clamp, SNP-1

046-00092-18 Take-up tube ASSY, NFTS-075

220-95356-25 For samples containing >5% HF


Includes:
220-95356-13 Sample Tubing ASSY, NFT-050
Nebulizer, DuraMist 046-00092-09 Connector, QSM
046-00092-10 Tube Adaptor, 0735
037-61113-01 Clamp, SNP-1
046-00092-19 Ratchet UniFit Kit

220-95356-26 For samples containing ≤5% HF


Includes:
220-95356-14 Sample Tubing ASSY, NFT-075

Nebulizer, OpalMist 046-00092-09 Connector, QSM


046-00092-10 Tube Adaptor, 0735
037-61113-01 Clamp, SNP-1
046-00092-19 Ratchet UniFit Kit

046-00092-12 For samples with up to 20% TDS


Includes:
Nebulizer, SeaSpray, 046-00092-09 Connector, QSM
ARG-1-USS2S 046-00092-10 Tube adaptor, 0735
037-61113-01 Clamp, SNP-1
046-00092-18 Take-up tube ASSY, NFTS-075

6
Back to Contents
Order at 800-477-1227, x2 or online at store.shimadzu.com
220-95356-01 For samples with up to 40% TDS

Nebulizer, Includes:
Noordermeer, 01-801-
0749 037-61113-01 Clamp, SNP-1

-- Take-up tube ASSY

Used to flush nebulizer with cleaning


Eluo™ Cleaning Tool 220-95356-02
solution to dislodge particle build-up

Spray Chambers
P/N Part Name Remarks External Appearance

Cyclone For use with Mini Torch and High Salts


Chamber, HE Torch
046-00093-02

Includes:
046-00093-92 Locking Screw
046-00093-93 Seal

Twister Spray
220-95356-11 For use with non-volatile organics
Chamber

Temperature-controlled sample
introduction system. Programmable
from -10°C to +60°C.
IsoMist Kit
Ideal for volatile organics. Also aids in
stability for long durations of
220-95356-10 continuous analysis.
Includes:
220-95356-12 PuraFlex Transfer Tube
046-00093-01 Drain
-- Bench-top Jack
210-15508-01 Ball Joint Clip

7
Back to Contents
Order at 800-477-1227, x2 or online at store.shimadzu.com
Tracey TFE Spray
220-95356-22 For use with HF system
Chamber

Old Style

Straight Chamber
211-80437-01 For use with non-volatile organics*
Drain

Water-Cooled
211-43472-00 For use with VOC torch
Chamber Kit

HF Chamber
205-07778-02 For use with HF system
ASSY

*Requires Nebulizer Holder Kit, Type 2 (see page 10)

8
Back to Contents
Order at 800-477-1227, x2 or online at store.shimadzu.com
Drains
P/N Part Name Remarks External Appearance

Drain Trap
046-00093-01 Drain for cyclone spray chamber
(Leveler)

016-31429-10 Drain Tube For use with Drain Trap

Drain device used with Tracey HF


220-95356-23 HF Drain
System

Old Style

Used for straight chamber, water-


Drain Kit cooled chamber, organics, and HF
system

211-86140-91
Includes:

035-65014-13 Half Union, HZ-01-0-PP

035-65102-01 Union, FZ28-00-PP

9
Back to Contents
Order at 800-477-1227, x2 or online at store.shimadzu.com
Orifices

P/N Part Name Remarks External Appearance

For use with Standard configuration and Small


211-84352-91 Orifice ASSY, L
Sample Amounts configuration

211-43740-00 Orifice ASSY For use with High Salts or Standard Size torch

Miscellaneous
P/N Part Name Remarks External Appearance

Used to prevent blockages in the nebulizer


204-19281-00 Water Bubbler
when analyzing high salt samples

Nebulizer Holder
211-48062-00 Includes organic-solvent resistant O-rings
Kit, Type 2

10
Back to Contents
Order at 800-477-1227, x2 or online at store.shimadzu.com
211-86533-00 Connect Pipe L Connects torch to sample introduction accessories

210-15508-01 Ball Joint Clip Used with Connect Pipe L

046-00993-01 Clip Attaches Drain Trap to Cyclone Chamber

037-61113-04 Clamp, SNP-10 Attaches drain tubing to Drain Trap

220-95356-21 PFA Adapter Connect Pipe used with HF System

Old Style

211-84175-00 Connect Pipe HFS Connect Pipe used with HF System

11
Back to Contents
Order at 800-477-1227, x2 or online at store.shimadzu.com
ICPE-9000
Main Unit
P/N Part Name Remarks Replacement External Appearance

211-86308-00 Filter, Bottom RF Cooling Intake 1 Year

211-86287-00 Filter, Left Electronics Cooling 1 Year

Plasma Stand
For sample introduction accessories, see pages 3-9

P/N Part Name Remarks Replacement* External Appearance

Auxiliary gas and carrier gas


016-31404-00 Tygon Tubing 1/8" x 1/16" 1 Month
Specify length (meters)

Plasma Gas Tube


211-85118-91 Tube for plasma gas 1 Month
ASSY

Tygon tubing
016-31429-10 Drain Tube 7/16" x 1/16" 3 Months
Specify length (meters)

Tygon tubing
Leveler Exhaust
016-31428-00 3/16" x 5/16" x 7/16" 3 Months
Tube
Specify length (meters)

12
Back to Contents
Order at 800-477-1227, x2 or online at store.shimadzu.com
Partition Window
211-86114-95 Axial view window
Holder

*Varies by sample type

P/N Part Name Remarks External Appearance

Protects RF Induction Coil


211-80620-00 Bonnet
Only used with radial view kit

211-81444-00 Torch Adapter Used with Mini Torch

Torch Positioning
211-86093-91 Used to set torch height
Jig

211-88275-91 Axial Mirror Located in cooling jacket

Argon purge pipe for radial


211-85422-91 Ceramic Purge Pipe
view

13
Back to Contents
Order at 800-477-1227, x2 or online at store.shimadzu.com
Argon Supply
P/N Part Name Remarks Replacement External Appearance

210-14037-00 Inline Filter For argon supply 1 Year

035-69703-01 Insert, B-405-170 Two used when replacing filter 1 Year

035-62974-01 Sleeve Set, B400SET Two used when replacing filter 1 Year

Argon supply
016-43505-00 Tube, 44PP, White --
Specify length (meters)

Connect argon supply hose to


035-65503-00 Half Union, ¼” regulator. Comes with nut and --
ferrule.

14
Back to Contents
Order at 800-477-1227, x2 or online at store.shimadzu.com
Vacuum System
P/N Part Name Remarks Replacement External Appearance

017-30166-01 Pump Oil, R-2 1L 6 Months

210-07003-04 Molecular Sieve 1 kg 6 Months

017-30813-01 Silicone Grease HVAG-G, 50 g 6 Months

042-00125-25 Oil Mist Trap OMT-050A 6 Months

15
Back to Contents
Order at 800-477-1227, x2 or online at store.shimadzu.com
ASC-6100F
*Check Chemical Compatibility

Maintenance Parts

P/N Part Name Remarks External Appearance

206-50290-91 Nozzle ASSY, F Sample introduction nozzle for auto-sampler

Used to connect nozzle tubing to nebulizer


211-83697-00 Connection Tube
tubing

Sample Cups / Accessories

P/N Part Name Remarks External Appearance

046-00147-04 Vial, 16 mL Polypropylene vial, 16 mL

220-95369-00 Vials, 16 mL Polypropylene vials, 16 mL 1000/pk

200-93113-05 Reagent Tube Glass tube, 53 mL

046-00150-27 Vial, 12 mL Glass vial, 12 mL

16
Back to Contents
Order at 800-477-1227, x2 or online at store.shimadzu.com
220-95306-01 Vials, 12 mL Glass Vials, 12 mL 1000 /pk

Protects samples in auto-sampler from


206-50295-01 Turntable Cover
contamination

Peripheral Equipment
Software

P/N Part Name Remarks


211-44263-92 ICPEsolutions, v1.31 Win7 compatible (32-bit)
211-44280-91 QAQC Software Accuracy management software package
21 CRF Part 11 compliant.
Compatible with Win7 32-bit.
211-44482-93 ICPEsolution v2.00 For compliance, requires:
 QAQC Package (211-44280-91)
 CLASS-Public Agent (223-18236-92)

Auto-samplers

Part Name P/N Remarks External Appearance

Sample Capacity:
ASC-6100F 206-50100-30 60 x 15-mL sample tubes
8 x 20-/50-mL reagent cups

Sample Capacity:
220-95336-01 240 x 14-mL sample tubes
8 x 50-mL reagent vials
CETAC ASX-520 Requires:
211-83697-00 Connecting Tube

088-52848-42 CETAC/ICPE-9000 Comm. Cable

17
Back to Contents
Order at 800-477-1227, x2 or online at store.shimadzu.com
High-Sensitivity Analysis

P/N Part Name Remarks External Appearance

Ultrasonic Nebulizer; Sample injection


system developed for high-sensitivity ICP
analysis. Uses ultrasonic energy to
nebulize a solution consisting of
220-95337-01 CETAC U5000 AT+
extremely fine particles. This enables the
ICPE-9000 to perform analyses at a
sensitivity 10 times higher than
conventional nebulizers

Hydride Vapor Generator; Provides high-


220-95370-01 ESI hydrideICP sensitivity measurement for Ge, As, Se,
Sn, Sb, Te, Pb, Bi, Hg

Peristaltic Pumps

Pumps

P/N Part Name Remarks External Appearance

220-95370-02 ESI MP2 Four-channel peristaltic pump

Shimadzu
One-channel peristaltic pump
Peristaltic Pump

211-88177-91 Includes:
016-31424-00 Tygon® tubing

205-09340-00 Retainer Strap

18
Back to Contents
Order at 800-477-1227, x2 or online at store.shimadzu.com
Accessories

Part Name P/N Remarks


HVG Upgrade Kit 220-95363-03 Converts ESI MP2 pump to hydride vapor generator unit
Internal Standard Addition Kit 220-95363-30 Allows for in-line addition of internal standards
Includes nebulizer adapter, ¼-28 male/female barbed fittings (4
ICP Connection Kit 220-95370-03
each), and ASC nozzle

HVG Diagram:

Internal Standard Mixing Kit:

19
Back to Contents
Order at 800-477-1227, x2 or online at store.shimadzu.com
Tubing

Part Name P/N Remarks


BLK/BLK, Santoprene 220-95363-20 2-stop, MPP-076-PHR, 12/pk
BLK/BLK, PVC 220-95363-23 2-stop, flared, MPP-076-F-PVC, 12/pk
BLK/BLK, Solva 220-95363-24 2-stop, flared, MPP-076-F-S, 12/pk
ORG/GRN, PVC 220-95363-25 2-stop, flared, MPP-038-F-PVC, 12/pk
RED/RED, PVC 220-95363-26 2-stop, MPP-114-PVC, 12/pk
GRY/GRY, Santoprene 220-95363-27 2-stop, MPP-130-PHR, 12/pk
BLK/BLK/BLK, Tygon 220-95363-40 3-stop, flared, ES-4397-3076, 12/pk
ORG/GRN/ORG Tygon 220-95363-41 3-stop, flared, ES-4397-3058, 12/pk
ORG/YEL/ORG PVC 220-95363-42 3-stop, flared, ES-4397-3051, 12/pk
YEL/BLU/YEL PVC 220-95363-43 3-stop, flared, ES-4397-3152, 12/pk

Probe ASSY 220-95363-50 For HVG; sample/reagents

Chillers/Cooling Kits

Part Name P/N Remarks External Appearance

Cooling water circulator for ICPE-


044-01813-01
9000
Cooling Water Requires:
Circulator, CA-
1115A-1
211-86152-91 Valve Kit

Low-temperature
Thermostatic
044-01910-01 Chiller for CCD
Chamber, NCB-
1200(SP)

Tap Water Required when tap water is used to


211-86153-91 --
Connection Kit cool ICPE-9000

20
Back to Contents
Order at 800-477-1227, x2 or online at store.shimadzu.com
Chemical Compatibility: ASC-6100F

Chemical Sample Rinse Liquid


Water (<0.5% acid) ✓ ✓
Ethanol ✓ ✓
Hydrochloric acid ✓ ✓
Nitric acid ✓ ✓
Sulfuric acid ✓ X
Xylene X X
Perchloric acid ✓** X
Methanol ✓ ✓
Sodium hydroxide ✓ X
Gasoline X X
Petroleum X X
Acetic acid X X
MIBK X X
Butyl acetate X X
Acetone X X
IPA X X
THF X X

✓Can be used
X CANNOT be used

** Glass sample cups required

21
Back to Contents
Order at 800-477-1227, x2 or online at store.shimadzu.com
Organic Solvents Compatibility
Boiling Point Vapor Pressure
Compound Torch Chamber
(°C) (mmHg)
Methanol 64.7 99 VOC Twister Spray Chamber
Ethanol 78.3 120 Standard Twister Spray Chamber
n-Propyl alcohol 97.5 15 Standard Twister Spray Chamber
Isopropyl alcohol 82.4 33 Standard Twister Spray Chamber
n-Butyl alcohol 117.5 4 Standard Twister Spray Chamber
n-Hexyl alcohol 157 3 Standard Twister Spray Chamber
Ethyl acetate 77.1 74 VOC Twister Spray Chamber
n-Butyl alcohol 126.3 10 Standard Twister Spray Chamber
Isobutyl acetate 118 13 Standard Twister Spray Chamber
Amyl acetate 148.8 Standard Twister Spray Chamber
Isoamyl acetate 142 4 Standard Twister Spray Chamber
Acetone 56.3 175 VOC IsoMist Spray Chamber
Dichloromethane 40 349 VOC Twister Spray Chamber
1,2-dichloroethane 83 64 VOC Twister Spray Chamber
Methyl isobutyl ketone (MIBK) 117 5 Standard Twister Spray Chamber
Di-isopropyl ketone 125 3 Standard Twister Spray Chamber
Di-isobutyl ketone (DIBK) 168 2 Standard Twister Spray Chamber
Acetylacetone 140.5 Standard Twister Spray Chamber
Acetic acid 117.8 12 Standard Twister Spray Chamber
Proprionic acid 141 2.8 Standard Twister Spray Chamber
n-Butyl Cellosolve 171.2 Standard Twister Spray Chamber
Chloroform 61.2 160 Standard Twister Spray Chamber
Carbon tetrachloride 76.7 90 Standard Twister Spray Chamber
o-Dichlorobenzene 180 1 Standard Twister Spray Chamber
Toluene 110.6 21 VOC Twister Spray Chamber
Xylene 138-144 47 Standard Twister Spray Chamber
Nitrobenzene 210.9 <1 Standard Twister Spray Chamber
Aniline 184.6 <1 Standard Twister Spray Chamber
Pyridine 115.5 15 Standard Twister Spray Chamber
Acetonitrile 81.6 70 Standard Twister Spray Chamber
Benzyl alcohol 205.4 <1 Standard Twister Spray Chamber
Tributyl phosphate 289 Standard Twister Spray Chamber
Dimethyl sulfoxide (DMSO) 189 0.4 Standard Twister Spray Chamber
n-Methyl-2-pyridone (NMP) 202 Standard Twister Spray Chamber
N,N-dimethylacetamide (DMA) 165.5 Standard Twister Spray Chamber
Gasoline 35-200 VOC IsoMist Spray Chamber
Kerosene 150-300 Standard Twister Spray Chamber
Light oil 220-350 Standard Twister Spray Chamber
Naphtha 30-200 VOC IsoMist Spray Chamber

22
Back to Contents
Order at 800-477-1227, x2 or online at store.shimadzu.com
System Configurations

23

Back to Contents
Order at 800-477-1227, x1710 or online at store.shimadzu.com

Shimadzu Corporation Company names, product/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation
and its affiliates, whether or not they are used with trademark symbol “TM” or “ R “.
URL: www.shimadzu.com/AN/ Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services.
Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own.
Shimadzu Scientific Instruments For Research Use Only. Not for use in diagnostic procedures.
7102 Riverwood Drive, Columbia, Maryland 21046, U.S.A. The contents of this publication are provided to you “as is” without warranty of any kind, and are subject to change without notice.
Phone: 800-477-1227/410-381-1227, Fax: 410-381-1222 Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this
URL: www.ssi.shimadzu.com publication.