Series ISO 3
Individual mounting Series
Valve only – Valve only –
No base No base
non “plug-in” “plug-in”
Conform to Conform to
ISO 5599/1 ISO 5599/2
33
Manifold mounting 34
Valve only – Valve only –
No base
non “plug-in”
No base
“plug-in” 36
Conform to Conform to
ISO 5599/1 ISO 5599/2
32
42
Air return
47
48P
External pilot 3 2 1 4 5
supply 48
400
92
SERIES FEATURES
93
• Plug-in (5599/2) and non plug-in (5599/1) models. ISO 01
• 2-position, single or double operator. (Solenoid or Remote Air)
• 3-position, double solenoid, open center, closed center, and pressure center.
ISO 02
• Extended or recessed manual operators. ISO 1
• Single pressure and dual pressure. ISO 2
• Individual base or add-a-unit manifold base.
• Plug-in, sandwich, single and dual pressure regulators for both individual and manifold valves.
ISO 3
191 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Direct solenoid and solenoid pilot operated valves
Series ISO 3
Function Port size Flow (Max) Individual/Manifold mounting Series
Valve only –
No base
5/2, 5/3 1/2” - 3/4” 6.1 Cv “non plug-in”
Conform to
ISO 5599/1
OPERATIONAL BENEFITS
33
1. Unique patented Macsolenoid® for fastest 6. Plug-in design of valves, bases and
possible response times and virtually burn- regulators for modular assembly and ease of
34
out proof AC solenoid operation. maintenance.
2. Balanced poppet 4-way pilot valve provides 7. Internal or external pilot operation. 36
maximum shifting forces, precise Manifolds supplied with common external
repeatability and consistent operation. pilot.
3. MAC spool and bore combination wipes 8. Air only return. Optional memory spring is
away contamination, eliminates sticking and also available.
32
allows for use on non-lube service. 9. Optional low wattage DC solenoid down to
4. Large spool area for maximum shifting forces 1.0 watt. 37
even at minimum operating pressure.
5. Very high flow in a compact package. 38
52
HOW TO ORDER
67
SINGLE PRESSURE MODELS 69
Pilot air 5/2
Single operator
5/2
Double operator
5/3
Closed center
5/3
Open center
44
14 4 2 12 14 4 2 12 14 4 2 12 14 4 2 12
46
5 3 5 3
5 1 3 5 1 3 1 1
5 1 3 5 1 3
5
1
3 48
Internal pilot From port #3 MV-B3A-ACAD-DM-DXXX-XXX MV-B3A-ADAD-DM-DXXX-XXX MV-B3A-AGAD-DM-DXXX-XXX
Internal pilot From port #5 MV-B3A-ACAE-DM-DXXX-XXX MV-B3A-ADAE-DM-DXXX-XXX MV-B3A-AGAE-DM-DXXX-XXX
External pilot From "12" end MV-B3A-ACAB-DM-DXXX-XXX MV-B3A-ADAB-DM-DXXX-XXX MV-B3A-AGAB-DM-DXXX-XXX 400
SOLENOID OPERATOR ® DM-D XXX-XXX * 92
OF
PRODUCTION
TESTED
100%
18 MONTHS
Series ISO 3
TECHNICAL DATA
Spare parts : • Pilot valve: DMB-Dxxx-xxx • Valve to base pressure seal: 16614
• Valve mounting screws (x4): 35451
40.0 19.0
139.9
MODIF.
WATTS
LIEGE,BELGIUM
AUCKLAND,N.Z.
WIXOM,MI. USA
138.5
160.8
5 3
44.5 1 2
4
27.0 33.0
23.5 65.8 63.3
1 3
48.8 47.0
32.8 48.0
29.0 5 27.8
COND
57.5
17.3
78.0 50.2
96.0
98.5
140.0
127.0 162.0
175.2
126.0
8.3 DIA. THRU 188.9
77.0 4 MTG. HOLES
232.1
7.5 28.0
8.25 DIA. THRU
2 MTG HOLES 136.4
18.5
24.5 99.9
5 3 25.8
66.5 1
54.5
2
27.0 19.0
33.4 39.0
64.0
4 2 59.0
78.0
31.0 5
1
OPTIONAL BTM PORTS 3
4
7.0 140.0
59.5 208.0 9.0
55.7
94.5
194 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Direct solenoid and solenoid pilot operated valves
Series ISO 3
Function Port size Flow (Max) Individual/Manifold mounting Series
Valve only –
No base
5/2, 5/3 1/2” - 3/4” 6.1 Cv “plug-in”
Conform to
ISO 5599/2
OPERATIONAL BENEFITS
33
1. Unique patented Macsolenoid® for fastest 6. Plug-in design of valves, bases and
possible response times and virtually burn- regulators for modular assembly and ease of
34
out proof AC solenoid operation. maintenance.
2. Balanced poppet 4-way pilot valve provides 7. Internal or external pilot operation. 36
maximum shifting forces, precise Manifolds supplied with common external
repeatability and consistent operation. pilot.
3. MAC spool and bore combination wipes 8. Air only return. Optional memory spring is
away contamination, eliminates sticking and also available.
32
allows for use on non-lube service. 9. Optional low wattage DC solenoid down to
4. Large spool area for maximum shifting forces 1.0 watt. 37
even at minimum operating pressure.
5. Very high flow in a compact package. 38
52
HOW TO ORDER
67
SINGLE PRESSURE MODELS 69
Pilot air 5/2
Single operator
5/2
Double operator
5/3
Closed center
5/3
Open center
44
14 4 2 12 14 4 2 12 14 4 2 12 14 4 2 12
46
5 3 5 3
5 1 3 5 1 3 1 1
5 1 3 5 1 3
5
1
3 48
Internal pilot From port #3 MV-P3A-ACAD-DM-DXXP-XXX MV-P3A-ADAD-DM-DXXP-XXX MV-P3A-AGAD-DM-DXXP-XXX
Internal pilot From port #5 MV-P3A-ACAE-DM-DXXP-XXX MV-P3A-ADAE-DM-DXXP-XXX MV-P3A-AGAE-DM-DXXP-XXX
External pilot From "12" end MV-P3A-ACAB-DM-DXXP-XXX MV-P3A-ADAB-DM-DXXP-XXX MV-P3A-AGAB-DM-DXXP-XXX 400
SOLENOID OPERATOR ® DM-D XX P-XXX * 92
OF
PRODUCTION
TESTED
100%
18 MONTHS
Series ISO 3
TECHNICAL DATA
Spare parts : • Pilot valve: DMB-DxxP-xxx • Valve to base pressure seal: 16614
• Valve mounting screws (x4): 35451
WATTS
WIXOM,MI. USA
AUCKLAND,N.Z.
LIEGE,BELGIUM
12
ELECTRICAL
MODEL
P
77,9
50.0
23.0
2 4
139.9
MODIF.
WATTS
LIEGE,BELGIUM
AUCKLAND,N.Z.
WIXOM,MI. USA
28.5
MODEL
29.0 23.5
31.0
48.5 160.8
69.0
14 12 27.0 19.0
33.4
39.0
59.0
78.0
158.0 31.0 5
1
24.0 3
4
51.5
86.5 208.0 9.0
55.7
114.0
196 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
R e m o t e a i r v a l v e s
Series ISO 3
Function Port size Flow (Max) Individual/Manifold mounting Series
5/2 – 5/3 1/2" – 3/4" 6.2 Cv Valve only –
no base
OPERATIONAL BENEFITS
HOW TO ORDER
5 3 5 3
5 1 3 5 1 3 1 1
Internal MV-R3A-BACF
MV-R3A-BBAK MV-R3A-BEAK MV-R3A-BFAK
External MV-R3A-BACG
5 3
5 1 3 5 1 3 1
Note: ISO series, valve and base are ordered separately, see page 239 for base code.
221 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
100% WARRANTY
100%
OF
PRODUCTION
TESTED
18 MONTHS
Series ISO 3
TECHNICAL DATA
Spare parts : • Valve to base pressure seal: 16614 • Valve mounting screws (x4): 35451
WIXOM,MI USA
LIEGE,BELGIUM
AUCKLAND,N.J.
MODIF. ISO
5599/2
63.4
MODEL VAC TO
150 PSI
160.0
56.8
222 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
B a s e s a c c o r d i n g t o I S O 5 5 9 9 / 1
Series ISO 3
Series
ISO 01
ISO 02
ISO 1
ISO 2
ISO 3
HOW TO ORDER
INDIVIDUAL BASE
Port size Side ports Bottom ports Bottom cylinder Bottom inlet port 1
ports 2 and 4.
MANIFOLD BASE
Port size Side ports Bottom ports Bottom cylinder Bottom inlet port 1
ports 2 and 4.
239 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
100% WARRANTY
100%
OF
PRODUCTION
TESTED
18 MONTHS
Series ISO 3
Individual
ISO DIN 5599/1
140,0 Ø 8,3
4 MTG. HOLES
70,0
35,0
17,5
15,0
39,5
12 14
32,0 2 4
64,0 79,0
55,0 21,0
46,0 2 4 43,5 1
33,0 27,0 3 5
22,0
15,0
45,0 45,0 49,0 49,0
78,0 OPTIONAL BOTTOM
20,5 20,5 PORTS
156,0
49,0 49,0
1/8” EXTERNAL PILOT/
REMOTE AIR PILOT PORT (2 PLACES)
Manifold
26.5
12
P
77,9
50.0
23.0
2 4
40.0 19.0
8.25 DIA. THRU 136.4
2 MTG HOLES
99.9
25.8
2
27.0 19.0
33.4 39.0
65.8 63.3 59.0
1 3 78.0
48.8 47.0 31.0 5
32.8 48.0 1
3
5 27.8
COND
4
240 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
B a s e s a c c o r d i n g t o I S O 5 5 9 9 / 1
Series ISO 3
Series
Plug-in manifold
ISO 01
ISO 02
ISO 1
ISO 2
ISO 3
HOW TO ORDER
MANIFOLD BASE
Port size Wired for Side ports Side ports w/ bottom All side & bottom ports
2 & 4 ports (see note)
OPTIONS
light(s) MM-P3A-XXX-XJA
JA 110/120 volt
JB 220/240 volt
DA 24 volt
241 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
100% WARRANTY
OF
PRODUCTION
TESTED
100%
18 MONTHS
Series ISO 3
MODIF.
WATTS
LIEGE,BELGIUM
AUCKLAND,N.Z.
WIXOM,MI. USA
139.4
29.0 28.5
23.5
31.0
48.5
69.0
89.5
106.5
142.0
193.0
166.5
8.25 DIA THRU
2 MTG HOLES 107.0
69.0
31.0
5 1 3 24.5
69.5 8.5
54.5 79.0
62.0
4 2
14 12
158.0
24.0
51.5
86.5
114.0
242 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
P r e s s u r e r e g u l a t o r s
Series PRA3C
Series
Non plug-in sandwich pressure regulator with manual adjust knob
OPERATIONAL BENEFITS
PR37A
1. Easy mounting : saves on installation costs in
comparison with inline regulators.
2. Allows to have compact, all-included units.
PR42B
3. Large orifice provides high flow.
4. Various functions available.
PR46A
5. Simple, reliable and solid design.
PR47A
PR48B
HOW TO ORDER
PR92C
INTERNAL PILOT
Single pressure Single pressure Dual pressure * Dual pressure * Dual pressure *
Gage Regulator 14 end Regulator 12 end Regulator 14 end Regulator 12 end Dual regulator
Same regulated pressure Same regulated pressure Regulated pressure Regulated pressure Two regulated pressures
to ports 2 and 4 to ports 2 and 4 to port 4 to port 2 to ports 2 and 4 PR93A
No gage PRA3C-1AAA PRA3C-1EAA PRA3C-1BAA PRA3C-1FAA PRA3C-1JAA
Non-filled gage PRA3C-1ADA PRA3C-1EDA PRA3C-1BDA PRA3C-1FDA PRA3C-1JEA
on regulator(s)
Non-filled gage PRA3C-1CDA PRA3C-1GDA PRA3C-1DDA PRA3C-1HDA ----- PRA01A
opposite to regulator
Glycerine filled gage PRA3C-1ABA PRA3C-1EBA PRA3C-1BBA PRA3C-1FBA PRA3C-1JCA
on regulator(s) PRA02A
Glycerine filled gage PRA3C-1CBA PRA3C-1GBA PRA3C-1DBA PRA3C-1HBA -----
opposite to regulator
* - To be used with dual pressure valves. Main valve body assembly must be external pilot model. Pilots
Note : regulating range for above models is 0-150 PSI. are supplied internally from primary pressure in regulator block. PRA3C
For other ranges see technical data page. Cannot field convert regulator block from Single Pressure to dual
pressure. Body/Block to base mounting screw #35418.
ADJUSTMENT OPTIONS
PRA3C-XXXX PRP3B
A for slotted stem adjustment (internal pilot)
B for slotted stem adjustment (external pilot)
D for slotted stem with locknut (internal pilot)
E for slotted stem with locknut (external pilot) 291 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
100% WARRANTY
100%
OF
PRODUCTION
TESTED
18 MONTHS
Series PRA3C
TECHNICAL DATA
Spare parts : • Pressure regulator (less sandwich block) : PRA3C-30AA (KNOB), PRA3C-C0AA (SLOTTED STEM), PRA3C-F0AA (SLOTTED STEM WITH LOCKNUT).
• Gage : • Glycerine filled : N-62015-01
• Non filled : N-62016-01
340.1
APPROX. WITH
REGOLATOR '12' END
MODIF.
WATTS
WIXOM,MI. USA
AUCKLAND,N.Z.
LIEGE,BELGIUM
234.0
7
3 1
5 COND
78.0
324.3
APPROX. WITH
REGULATOR '14' END
432.3
APPROX. WITH
DOUBLE REGULATOR
292 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
P r e s s u r e r e g u l a t o r s
Series PRA3C
Series
Non plug-in sandwich pressure regulator with air pilot adjust
OPERATIONAL BENEFITS
PR37A
1. Easy mounting : saves on installation costs in
comparison with inline regulators.
2. Allows to have compact, all-included units.
PR42B
3. Large orifice provides high flow.
4. Various functions available.
PR46A
5. Simple, reliable and solid design.
PR47A
PR48B
HOW TO ORDER
PR92C
INTERNAL PILOT
Single pressure Single pressure Dual pressure * Dual pressure * Dual pressure *
Gage Regulator 14 end Regulator 12 end Regulator 14 end Regulator 12 end Dual regulator
Same regulated pressure Same regulated pressure Regulated pressure Regulated pressure Two regulated pressures
to ports 2 and 4 to ports 2 and 4 to port 4 to port 2 to ports 2 and 4 PR93A
No gage PRA3C-4AAA PRA3C-4EAA PRA3C-4BAA PRA3C-4FAA PRA3C-4JAA
Non-filled gage PRA3C-4ADA PRA3C-4EDA PRA3C-4BDA PRA3C-4FDA PRA3C-4JEA
on regulator(s)
Non-filled gage PRA3C-4CDA PRA3C-4GDA PRA3C-4DDA PRA3C-4HDA ----- PRA01A
opposite to regulator
Glycerine filled gage PRA3C-4ABA PRA3C-4EBA PRA3C-4BBA PRA3C-4FBA PRA3C-4JCA
on regulator(s)
PRA02A
Glycerine filled gage PRA3C-4CBA PRA3C-4GBA PRA3C-4DBA PRA3C-4HBA -----
opposite to regulator
293 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
100% WARRANTY
100%
OF
PRODUCTION
TESTED
18 MONTHS
Series PRA3C
TECHNICAL DATA
212.0
294 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
P r e s s u r e r e g u l a t o r s
Series PRP3B
Series
Plug-in sandwich pressure regulator with manual adjust knob
OPERATIONAL BENEFITS
PR37A
1. Easy mounting: saves on installation costs in
comparison with inline regulators.
2. Compact all-included units.
PR42B
3. Large orifice provides high flow.
4. Various functions available.
PR46A
5. Simple, reliable and solid design.
PR47A
PR48B
HOW TO ORDER
PR92C
REGULATORS FOR INTERNAL PILOT (CODED FOR KNOB ADJUSTMENT)
Single pressure Single pressure Dual pressure * Dual pressure * Dual pressure *
Gage Regulator 14 end Regulator 12 end Regulator 14 end Regulator 12 end Dual regulator
Same regulated pressure Same regulated pressure Regulated pressure Regulated pressure Two regulated pressures
to ports 2 and 4 to ports 2 and 4 to port 4 to port 2 to ports 2 and 4 PR93A
No gage PRP3B-AAAA PRP3B-AEAA PRP3B-ABAA PRP3B-AFAA PRP3B-AJAA
PRP3B-XXXX
G for slotted stem (internal pilot) Notes:
PRA3C
H for slotted stem (external pilot) 1. Regulating range for above models is 0-150 PSI. For other ranges, see
K for slotted stem with locknut (internal pilot) technical data page.
L for slotted stem with locknut (external pilot) 2. Valves used with above models must be external pilot models.
3. Cannot field convert regulator block from single pressure to dual pressure. PRP3B
4. Cannot field convert from internal pilot to external pilot.
5. Wired for double solenoid valves.
295 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
100% WARRANTY
100%
OF
PRODUCTION
TESTED
18 MONTHS
Series PRP3B
TECHNICAL DATA
Spare parts : •Pressure regulator (less sandwich block): PRP3B-C0AA (knob), PRP3B-J0AA (slotted stem), PRP3B-M0AA (slotted stem with locknut)
• Regulating block to base mounting screw: 19457
• Regulating range options: PRP3B-xxxA
Replace by B for 0 to 100 PSI
Replace by C for 0 to 45 PSI
212.0
296 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
P r e s s u r e r e g u l a t o r s
Series PRP3B
Series
Plug-in sandwich pressure regulator with air pilot adjust
OPERATIONAL BENEFITS
PR37A
1. Easy mounting: saves on installation costs in
comparison with inline regulators.
2. Compact all-included units.
PR42B
3. Large orifice provides high flow.
4. Various functions available.
PR46A
5. Simple, reliable and solid design.
PR47A
PR48B
HOW TO ORDER
PR92C
REGULATORS FOR INTERNAL PILOT
Single pressure Single pressure Dual pressure * Dual pressure * Dual pressure *
Gage Regulator 14 end Regulator 12 end Regulator 14 end Regulator 12 end Dual regulator
Same regulated pressure Same regulated pressure Regulated pressure Regulated pressure Two regulated pressures
to ports 2 and 4 to ports 2 and 4 to port 4 to port 2 to ports 2 and 4 PR93A
No gage PRP3B-DAAA PRP3B-DEAA PRP3B-DBAA PRP3B-DFAA PRP3B-DJAA
PRP2B
* - To be used with dual pressure valves.
Notes:
1. Valves used with above models must be external pilot models.
2. Cannot field convert regulator block from single pressure to dual pressure.
3. Cannot field convert from internal pilot to external pilot. PRA3C
4. Wired for double solenoid valves.
PRP3B
297 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
100% WARRANTY
100%
OF
PRODUCTION
TESTED
18 MONTHS
Series PRP3B
TECHNICAL DATA
212.0
298 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
OPTIONS
- Pilot operated valves 52, 67, 92, 93, 400, ISO1, ISO2, ISO3 Series
309 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
OPTIONS
3. MANUAL OPERATOR
310 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
How To Order
ISO 3 Non Plug-In Regulator
PRA3C - X X X X - X
The warnings and precautions below are important to be read and understood before OPERATING SPECIFICATIONS -
designing into a system any MAC Valves products, and before installing or servicing any MAC Valves MAC Valves products are to be installed only on applications that meet all operating specifications
product. Improper use, installation or servicing of any MAC Valves product in some systems could described in the MAC catalog for the MAC Valves product.
create a hazard to personnel or equipment. No distinction in importance should be made between
the terms warnings and precautions. MANUAL OPERATORS-
Most MAC valves can be ordered with manual operators. Manual operators when depressed, are
WARNING : . designed to shift the valve to the same position as would the corresponding solenoid or remote air
Under no circumstances are MAC Valves products to be used in any application or in any manner pilot operator if it were activated. Care must be taken to order a type, if any, that will be safe for the
where failure of the MAC Valves product to operate as intended could in any way jeopardize the physical location of the manual operator in the system. If intentional or accidental operation of a
safety of the operator or any other person or property. valve by a manual operator could cause personal injury or property damage, a manual operator
• Do not operate outside of pressure range listed on a valve label or outside of the designated should not be used.
temperature range.
• Air supply must be clean and dry. Moisture or contamination can affect proper operation of the REMOTE AIR OPERATED VALVES
valve. Pilot valves supplying signal pressure to remote air operated valves should be 3-way valves with
• Before attempting to repair, adjust or clean a MAC Valves product, consult catalog, parts & operation adequate supply and exhaust capacity to provide positive pressurizing and exhausting of the pilot
sheet, or factory for proper maintenance procedures, lubrication and cleaning agents. Never supply line. Pilot lines should be open to exhaust when valves are deenergized.
attempt to repair or perform other maintenance with air pressure to the valve.
• If air line lubrication is used do not use any lubrication other than those recommended in the INSTALLATION PRECAUTIONS : .
catalog, parts & operation sheet or by the factory. A. Do not install any MAC Valves product without first turning off air (bleed system completely) and
electricity to the machine.
APPLICATION PRECAUTIONS : . B. MAC Valves products should only be installed by qualified, knowledgeable personnel who
INDUSTRIAL USE - understand how the specific valve is to be pneumatically piped and electrically connected (where
• MAC Valve products are intended for general use in industrial pneumatic and/or vacuum systems. applicable). Flow paths through the valve are shown in the catalog and on the valve by use of ANSI
They are general purpose industrial products with literally thousands of different applications in or ISO type standard graphic symbols. Do not install unless these symbols and the valve functions
industrial systems. These products are not inherently dangerous, but they are only a component of and operations are thoroughly understood.
an overall system. The system in which they are used must provide adequate safeguards to prevent C. If air line lubrication is used do not use any lubrication other than those recommended in the
injury or damage in the event failure occurs, whether it be failure of switches, regulators, cylinders, catalog, parts & operation sheet or by the factory.
valves or any other component.
SERVICE PRECAUTIONS :
POWER PRESSES - A. Do not service or remove from service any MAC Valves product without first shutting off both the
MAC Valve products are not designed nor intended to be used to operate and/or control the air and electricity to the valve and making certain no pressurized air which could present a hazard
operation of clutch and/or brake systems on power presses. There are special products on the market is retained in the system.
for such use. B. MAC Valves products should only be serviced or removed from service by qualified, knowledgeable
personnel who understand how the specific product is used and/or how the specific valve is piped
2-POSITION VALVES - and used and whether there is air retained in the connecting lines to the valve or electric power still
Some MAC valves are 2-position, 4-way valves. When air is supplied to the inlet port(s) of these valves, connected to the valve.
there will always be a flow path from the inlet to one of the outlets regardless of which of the two C. Before attempting to repair, adjust or clean a MAC Valves product, consult catalog, parts &
positions the valve is situated. Therefore, if pressurized air retained in the system would present a operation sheet, or factory for proper maintenance procedures, lubrication and cleaning agents.
hazard in the application or servicing of the valve or system, a separate method in the system must Never attempt to repair or perform other maintenance with air pressure to the valve.
be provided to remove the trapped air. D. MAC Valves products are never to be stepped on while working on a machine. Damage to a MAC
valve, or other product or lines to the product (either air or electrical lines) or accidental activation
3- POSITION VALVES- of a manual operator on the valve could result in personal injury or property damage.
Some MAC valves are 3-position, 4-way valves. These valves are either double solenoid or double
remote air operated. LIMITATION OF GUARANTEE .
If either of the two operators is in control, air supplied to the inlet port(s) will pass through the valve This Guarantee is limited to the replacement or rebuilding of any valve or other product which should
to one of the outlets as on 2-position, 4-way valves. However, if neither operator is in control, the fail to operate properly. Valves or other products, under the MAC Guarantee, must be returned (with
valve moves to a center position. Listed below are the various center position functions : or without bases) transportation prepaid and received at our factory within the Guarantee period.
They will be returned to the customer at the expense of MAC Valves, Inc., and will carry the same
A. CLOSED CENTER- guarantee as provided under the Flat Rate Rebuild Program.
With this type valve, when in the center position all ports are blocked (inlets and exhausts) meaning
the air at both outlet ports is trapped. If trapping the air in both outlet ports would present a hazard DISCLAIMER OF GUARANTEE .
in the application or servicing, a separate method in the system must be provided to remove the No claims for labor, material, time, damage, or transportation are allowable nor will any valve or other
trapped air or this type valve should not be used. product be replaced or rebuilt under this guarantee which has been damaged by the purchaser not
in the normal course of its use and maintenance during the warranty period. The guarantee does not
B. OPEN CENTER- apply to loss or damage caused by fire, theft, riot, explosion, labor dispute, act of God, or other causes
With this type valve, when in the center position, the inlet port(s) is blocked and the two outlet ports beyond the control of MAC Valves,Inc. MAC Valves, Inc. shall in no event be liable for remote, special
are open to the exhaust port(s) of the valve. If having no air in either outlet port would present a or consequential damages under the MAC Guarantee, nor under any implied warranties, including
hazard in the application or servicing, this type valve should not be used. the implied warranty of merchantability.
C. PRESSURE CENTER- The above Guarantee is our manner of extending the engineering and service resources of the MAC
With this type valve, when in the center position, the inlet port(s) is connected to both outlet ports of Valves, Inc. organization to assure our customer long, and continued satisfaction.
the valve. If having pressurized air to either or both outlet ports would present a hazard in the
application or servicing of the valve or system, a separate method in the system must be
provided to remove the retained air or this type valve should not be used.
327
MAC Valves Product Warranty Information
The MAC Valves organization has established a reputation over many years for fulfilling the needs and requirements of the
users of its products. All MAC Valves are quality products specifically designed and built for long and rugged service. For
this reason, MAC Valves is able to provide the Buyer a limited warranty.
WARRANTY:
MAC Valves, Inc. hereby warrants to Buyer that, for a period of 18 months from the original date of shipment of each valve
from our factory (“Warranty Period”), such valve will be free from significant defects in material and workmanship and will
conform to all specifications agreed to by MAC Valves, Inc.. In addition, MAC Valves, Inc. warrants that the electrical coils
on such valves will be free from significant defects in material and workmanship for their normal useful life. EXCEPT FOR
THESE LIMITED WARRANTIES, MAC VALVES, INC. EXPRESSLY DISCLAIMS ALL REPRESENTATIONS AND WARRANTIES OF
ANY KIND (WHETHER EXPRESS, IMPLIED OR ARISING BY OPERATION OF LAW) WITH RESPECT TO THE VALVES,
INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY, FITNESS FOR
A PARTICULAR PURPOSE OR ANY OTHER MATTER. THIS SECTION SURVIVES THE EXPIRATION, TERMINATION OR
CANCELLATION OF ANY AGREEMENTS BETWEEN THE PARTIES RELATING TO THE PURCHASE OF THE VALVES.
WARRANTY LIMITATIONS:
This Warranty does not apply where the valves have been (i) subjected to abuse, misuse, damage, neglect, negligence,
accident, improper testing, improper installation, improper storage, improper handling, abnormal physical stress, abnormal
environmental condition, or use contrary to any instructions issued by MAC Valves, Inc.; (ii) modified, reconstructed, repaired,
or altered by persons other than MAC Valves, Inc. or its authorized representative; or (iii) used with any third-party product,
hardware, software or other product that has not been previously approved in writing by MAC Valves, Inc. Additionally, this
Warranty does not cover claims for labor, material, time or transportation, and does not apply to loss or damage caused by
fire, theft, riot, explosion, labor dispute, act of God, or other causes beyond the control of MAC Valves, Inc.
EXCLUSIVE REMEDY:
The Buyer’s sole remedy under this Warranty is limited to the replacement or rebuilding of any valve which does not conform
to the warranties provided herein or, in MAC Valves, Inc.’s sole discretion, refund of the purchase price for the non-conform-
ing valve. Buyer’s remedy is conditioned on Buyer’s compliance with its obligations under this Warranty. Valves that Buyer
believes do not conform to this Warranty must be returned (with or without bases) transportation prepaid and received at our
factory within the Warranty Period. If MAC Valves, Inc. determines that the valve is non-conforming and is otherwise covered
by this Warranty, the rebuilt or replaced valve will be returned to the customer at the expense of MAC Valves, Inc., and will
carry the same warranties as provided under the Flat Rate Rebuild Program described below. MAC VALVES, INC. WILL NOT
BE RESPONSIBLE FOR ANY INCIDENTAL, SPECIAL, EXEMPLARY OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT
LIMITATION DIRECT AND INDIRECT LOST PROFITS, REGARDLESS OF WHETHER THOSE DAMAGES WERE FORESEEABLE.
Please note that any valves sent back for subsequent rebuild that have already been through the program previously
(indicated by the “R”) will not be eligible for additional rebuild.