0% found this document useful (0 votes)
29 views7 pages

RRU5904 (2100Mhz) - Technical Specifications

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
29 views7 pages

RRU5904 (2100Mhz) - Technical Specifications

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

HedEx Startpage Page 1 of 7

3900 & 5900 Series Base Station Product Documentation


Product Version: V100R016C00
Library Version: Draft A
Date: 2019-09-10

For any question, please contact us.


Copyright © Huawei Technologies Co., Ltd. 2019. All rights reserved.

RRU5904 Technical Specifications


Contents
6.2.4.3.6 RRU5904 Technical Specifications

6.2.4.3.6 RRU5904 Technical Specifications


The RRU5904 is a multimode remote radio unit. With the software-defined radio (SDR) technology, the
RRU5904 can work in multiple modes through software configuration.

Supported Modes and Frequency Bands


The following table lists the modes and frequency bands supported by an RRU5904.

Table 1 Modes and frequency bands supported by an RRU5904


Type Frequency RX Frequency TX Frequency Mode IBW
Band Band (MHz) Band (MHz) (MHz)
(MHz)

RRU5904 1800 1710 to 1785 1805 to 1880 GSM, LTE FDD, 45


GL, LM, GLM, NR
FDD, LN FDD, GLN
(SUL)

RRU5904 2100 1920 to 1980 2110 to 2170 UMTS, LTE FDD, 60


UL, LN (SUL), ULN
(SUL)

http://localhost:7890/printtopics.html?time=Thu Sep 19 12:48:55 UTC-0300 2019 9/19/2019


HedEx Startpage Page 2 of 7

RF Specifications
The following tables list RF specifications of an RRU5904.

Table 2 Receiver sensitivity of an RRU5904


Type TX/RX Receiver Sensitivity Receiver Sensitivity Receiver Sensitivity
Channel with One Antenna with Two Antennas with Four Antennas
(dBm) (dBm) (dBm)

RRU5904 4T4R GSM: -114.0 GSM: -116.8 GSM: -119.5


UMTS: -126.1 UMTS: -128.9 (theoretical value)
LTE FDD: LTE FDD: UMTS: -131.6
• 1800 LTE FDD:
• 1800 MHz:
-106.6 MHz: • 1800 MHz:
• 2100 MHz: -109.4 -112.1
-106.9 • 2100 • 2100 MHz:
MHz: -112.4
LTE NB-IoT: -127.3
-109.7 LTE NB-IoT: -132.8
NR FDD:
LTE NB-IoT: NR FDD:
• 1800 MHz: -130.1
-106.3 • 1800 MHz:
NR FDD: -111.8
• 1800
MHz:
-109.1

NOTE:

• ATBR in the TX/RX Channel column indicates that the RF module uses A transmit
channels and B receive channels.
• The GSM receiver sensitivity, as recommended in 3GPP TS 51.021, is measured at the
antenna connector assuming that the channel rate is 13 kbit/s and the bit error rate (BER)
is lower than or equal to 2%.
• The UMTS receiver sensitivity, as recommended in 3GPP TS 25.104, is measured at the
antenna connector assuming that the channel rate is 12.2 kbit/s and the BER is lower than
or equal to 0.001.
• The LTE FDD receiver sensitivity, as recommended in 3GPP TS 36.104, is measured
under a 5 MHz channel bandwidth based on the FRC A1-3 in Annex A.1 (QPSK, R = 1/3,
25 RBs) standard.
• The LTE NB-IoT receiver sensitivity, as recommended in 3GPP TS 36.104, is measured
under a 200 kHz bandwidth and a 15 kHz subcarrier spacing based on the FRC A14-1 in
Annex A.14 (π/2 BPSK, R = 1/3, one RB) standard.
• The NR FDD receiver sensitivity, as recommended in 3GPP TS 38.104, is measured under
a 5 MHz bandwidth based on the Annex A.1 (QPSK, R = 1/3) standard.

Table 3 Capacity and output power of an RRU5904

http://localhost:7890/printtopics.html?time=Thu Sep 19 12:48:55 UTC-0300 2019 9/19/2019


HedEx Startpage Page 3 of 7

Type Capacity Maximum Output Typical Output Power


Power

RRU5904 GSM: 8 carriers 4x60 W For details, see Typical


(1800 MHz) LTE FDD: 3 carriers. The Power Configuration Reference
for RRU (Excluding NB-IoT)
bandwidth per carrier is 5, and NB-IoT Typical Power
10, 15, or 20 MHz. Configurations (RRU).
LTE NB-IoT: 1 carrier
NR FDD: 1 carrier. The
bandwidth per carrier is 5,
10, 15, or 20 MHz.

RRU5904 UMTS: 4x60 W For details, see Typical


(2100 MHz) Power Configuration Reference
• 8 carriers for RRU (Excluding NB-IoT) .
without MIMO
• 4 carriers with
MIMO
LTE FDD: 3 carriers. The
bandwidth per carrier is 5,
10, 15, or 20 MHz.
NR (SUL): 1 carrier. The
bandwidth per carrier is
15 or 20 MHz.

NOTE:
For details about power configuration principles for RF modules, see Power Configuration Principles for
RF Modules.

NR SUL Carrier Configuration


When NR SUL carriers are configured, the uplink bandwidth of LTE carriers enabled with LTE and NR
uplink spectrum sharing must be the same as the uplink bandwidth of NR carriers. The following table
lists the bandwidths. The uplink bandwidth of LTE carriers not enabled with uplink spectrum sharing is
the same as their downlink bandwidth. For details about the downlink bandwidth, see "Typical Output
Power".

Table 4 SUL carrier configuration of an RRU5904 (LN, 1800 MHz/2100 MHz, 4R)
Total Number of LTE FDD Total Number of NR SUL Bandwidth per NR SUL Carrier
Carriers Carriers (MHz)

3 (MIMO) 1 15, 20

Table 5 SUL carrier configuration of an RRU5904 (GLN, 1800 MHz, 4R)


Total Number of Total Number of LTE Total Number of Bandwidth per NR SUL
GSM Carriers FDD Carriers NR SUL Carriers Carrier (MHz)

8 2 (MIMO) 1 15, 20

http://localhost:7890/printtopics.html?time=Thu Sep 19 12:48:55 UTC-0300 2019 9/19/2019


HedEx Startpage Page 4 of 7

Total Number of Total Number of LTE Total Number of Bandwidth per NR SUL
GSM Carriers FDD Carriers NR SUL Carriers Carrier (MHz)

Table 6 SUL carrier configuration of an RRU5904 (ULN, 2100 MHz, 4R)


Total Number of Total Number of LTE Total Number of Bandwidth per NR SUL
UMTS Carriers FDD Carriers NR SUL Carriers Carrier (MHz)

8 2 (MIMO) 1 15, 20

2 (MIMO) 2 (MIMO) 1 15, 20

3 (MIMO) 1 (MIMO) 1 15, 20

Engineering Specifications
The following tables list the equipment specifications of an RRU5904.

Table 7 Input power of an RRU5904


Type Power

RRU5904 -48 V DC; voltage range: -36 V DC to -57 V DC

Table 8 Equipment specifications of an RRU5904


Type Dimensions (H x W x D) Weight (kg)

RRU5904 400 mm x 300 mm x 150 mm 22 (without the housing)


(18 L, without the housing)

Table 9 Power consumption of an RRU5904


Type Frequency Band (MHz) Typical Power Consumption (W)

RRU5904 1800 492

RRU5904 2100 492

NOTE:

• DC RRUs can use external power modules (such as AC/DC power modules, OPM15M,
and OPM50M) to support AC scenarios. For details about the external power modules, see
user guides of the corresponding models.
• The typical power consumption of an RF module is measured when the ambient
temperature is 25°C and the traffic load reaches 50%. The actual power consumption has a
10% deviation from this value.

The following table lists the environmental specifications of an RRU5904.

http://localhost:7890/printtopics.html?time=Thu Sep 19 12:48:55 UTC-0300 2019 9/19/2019


HedEx Startpage Page 5 of 7

Table 10 Environmental specifications of an RRU5904


Type Operating Temperature Relative Absolute Atmospheric
Humidity Humidity Pressure

RRU5904 • Without solar 5% RH to 1 g/m3 to 30 70 kPa to 106


radiation: -40° 100% RH g/m3 kPa
C to +55°C
• With solar
radiation: -40°
C to +50°C

NOTE:
According to the installation scenario, traffic load, and carrier configuration, the output power of an
RF module decreases when the RF module reaches a temperature 10°C less than its maximum
operating temperature.

The following table lists the compliance standards for an RRU5904.

Table 11 Compliance standards for an RRU5904


Item Standard

RF • 3GPP TS 45.005
• 3GPP TS 25.104
• 3GPP TS 36.104
• 3GPP TS 38.104
• 3GPP TS 37.104

Operating ETSI EN 300019-1-4 V2.1.2 (2003-04) Class 4.1: "Non-weatherprotected


environment locations"

Storage ETSI EN300019-1-1 V2.1.4 (2003-04) Class 1.2: "Weatherprotected, not


environment temperature-controlled storage locations"
NOTE:
• The validity period is one year.
• The product can function properly within the validity period
if the storage environment meets the preceding standards.

Shockproof NEBS GR63 zone4


protection

Ingress IP65
protection
rating

Surge • IEC 62305-1 Protection against lightning - Part 1: General


protection principles

http://localhost:7890/printtopics.html?time=Thu Sep 19 12:48:55 UTC-0300 2019 9/19/2019


HedEx Startpage Page 6 of 7

Item Standard
• IEC 62305-3 Protection against lightning - Part 3: Physical
damage to structures and life hazard
• IEC 62305-4 Protection against lightning - Part 4: Electrical and
electronic systems within structures
• ITU-T K.35 Bonding configurations and earthing at remote
electronic sites
• ITU-T K.56 Protection of radio base stations against lightning
discharges
• ITU-T K.97 Lightning protection of distributed base stations
• ETSI EN 300 253 Environmental Engineering (EE): Earthing
and bonding configuration inside telecommunications centers
• YD/T 2324-2011: Lightning protection requirements and test
methods for radio base stations
• GB 50689-2011: Code for design of lightning protection and
earthing engineering for telecommunication bureaus (stations)

The following table lists the surge protection specifications of ports on an RRU5904.

NOTE:

• Unless otherwise specified, the surge protection specifications depend on the surge
waveform of 8/20 μs.
• All the surge current items, unless otherwise specified as Maximum discharge current,
refer to Nominal discharge current.

Table 12 Surge protection specifications of ports on an RRU5904


Port Surge Protection Mode Surge Protection Specifications

Power supply port Surge current 20 kA

Specifications of CPRI Ports


The following tables list the specifications of CPRI ports on an RRU5904.

Table 13 Specifications of CPRI ports on an RRU5904


Type Number of CPRI Ports CPRI Data Rate (Gbit/s) CPRI Topology

RRU5904 2 1.25, 2.5, 4.9, or 9.8 Star, chain, or dual-star

Table 14 RRU5904 CPRI cascading levels and maximum distance from the BBU
Type Cascading Level Maximum Distance from the BBU (km)

RRU5904 Multimode Multimode (GL, UL, or GUL):


(excluding GU)

http://localhost:7890/printtopics.html?time=Thu Sep 19 12:48:55 UTC-0300 2019 9/19/2019


HedEx Startpage Page 7 of 7

Type Cascading Level Maximum Distance from the BBU (km)


CPRI MUX: 4 • When the LBBPc or LBBPd1 is
levels configured: 20
• When the LBBPd2, UBBPd3, UBBPd4,
UBBPd5, UBBPd6, UBBPg, or UBBPe is
configured: 40
• When the LBBPd3 is configured:
◾ Number of cells ≤ 3: 40
◾ Number of cells ≥ 4: 20
Multimode (including NB-IoT): 20
Multimode (including NR): 20

Antenna Capability
The following table lists the antenna capability of an RRU5904.

Table 15 Antenna capability of an RRU5904


Type TMA Support RET Antenna Support

RRU5904 Supported AISG2.0 and AISG1.1

NOTE:
For RF modules supporting RET antennas, the feeding voltage is 12 V and feeding current is 2.3 A.

Parent Topic: Technical Specifications of RRUs