Model Power Amplifier Output(s) Digital Signal Processor Mic/Line Inputs Line Outputs
A-9060SM2 1 × 60W @ 25/70V, 4/8Ω 2 Channels Up to 8 (4 × D-001T) Up to 7 (1 built-in plus 3 × T-001T)
A-9120SM2 1 × 120W @ 25/70V, 4/8Ω 2 Channels Up to 8 (4 × D-001T) Up to 7 (1 built-in plus 3 × T-001T)
A-9240SHM2 1 × 240W @ 70V 2 Channels Up to 8 (4 × D-001T) Up to 7 (1 built-in plus 3 × T-001T)
A-9060DHM2 2 × 60W @ 70V 2 Channels Up to 8 (4 × D-001T) Up to 6 (3 × T-001T)
A-9120DHM2 2 × 120W @ 70V 2 Channels Up to 8 (4 × D-001T) Up to 6 (3 × T-001T)
M-9000M2 2 × Line Level 2 Channels Up to 8 (4 × D-001T) Up to 8 (2 built-in plus 3 × T-001T)
Features
■ Multiple Input Priority Modes sets priority order when multiple inputs with ■ Alphanumeric Input/Output Channel and Memory Naming
the same priority level and output assignment are broadcast ■ Two Remote Volume Control Terminals on mainframe
• First-In-First-Out (FIFO): input that occurs first is broadcast
■ Four Control Inputs – programmable to activate Paging/Scene
• Last-In-First-Out (LIFO): the most recent input is broadcast
Memory, Volume Up/Down (Input or Output), Mute (Input or Output),
• MIX: all inputs are simultaneously mixed and broadcast
Power On/Off, Emergency Mute, Sync On/Off (expandable to twelve
■ Voice Operated (VOX) paging activation with adjustable with C-001T module). Works with optional ZM-9003 or custom contact
threshold/sensitivity and gate release time panel
■ Stereo Link – Mirrors all the settings of one channel to the adjacent ■ Four Control Outputs (open collector) programmable to activate
channel, reducing redundant setup tasks for stereo signals external relays (expandable to twelve with C-001T module)
■ Speaker Line Switching – select up to four speaker lines from a single synchronized with Event/Scene Memory, Channel On/Off (Input or
amplifier output using optional model SS-9001 Speaker Selector and Output) and Power On/Off. Works with optional ZM-9003 or custom
AD-246 Power Supply contact panel.
■ Mixer Out/Power Amp In Patching Loops (Except M-9000M2) for ■ RS-232C serial port
connection of external processor(s) • Allows upload & download of programming templates and firmware
upgrades as well as real-time control of various parameters.
■ Balanced Line Output(s) – two: M-9000M2, one: A-9060SM2,
• Control protocol available
A-9120SM2, A-9240SHM2; expandable with T-001T dual line
• AMX and Crestron control modules available
output modules
*AMX is a trademark of AMX Corporation
■ Keylock Security sets password-protected access to prevent access to *Crestron is a trademark of Crestron Electronics, Inc.
Input, Output, Utility & Power functions
9000M2 GUI
Detailed screens make even complex setting
Paging Settings
Set 3-level prioritized paging for each activation trigger (up to 32)
To handle multiple simultaneous paging calls with the same priority
level, the system can be set for “FIFO” (first in, first out), “LIFO” (last in,
first out), or “MIX” (mixing). This allows paging settings to handle
situations requiring sophisticated priority orders, for example in mass
notification systems. It is also possible to make settings that cause a
contact to be closed with the initiation of each page, a feature that can
be used to illuminate a strobe, call up a CCTV camera’s preset
positions, or enable audio or video recording via external equipment.
Additionally, the optional S-20S module allows different messages to
be broadcast corresponding to individual triggered outputs.
gs intuitive and easy to understand
EQ Settings
Select from 3 types: LPF, HPF and PEQ. Up to 12 filters can be
applied to each input-output channel
TOA's Speaker preset EQ is visible in graphic display
Use the Adjust button to change and check the effects of EQ settings on
the fly. Use the Enable check boxes to deactivate filters without erasing
their settings. Use the All Bypass button to disable all filters at once.
Using these in conjunction with the Adjust button allows EQ effects to be
compared efficiently.
Cross Point
Settings
Up to 32 preprogram-
med broadcast patterns
that switch according to
each scene can be
stored in the scene
memory.
MODULES
D-001T ZP-001T AN-001T
Dual Mic/Line Input Module Telephone Zone Paging Ambient Noise Controller
with DSP Module Module
■ Two Balanced Mic / Line Inputs ■ Telephone Paging to up to eight zones ■ Automatically adjusts output gain to
■ Digital Signal Processing ■ Uses DTMF dialing to access outputs compensate for changes in
• 10-Band Parametric EQ ■ Dial up to eight output zones in ambient noise level
• Bass / Treble one operation ■ Each input can be assigned to
• Loudness ■ Analog extension or page port compatible control a specific output
• High and Low Pass Filters ■ Two inputs with +24VDC phantom power for
■ Page port operation requires contact closure activation
• Compressor condenser mics
■ RJ-11 Telephone Jack and Removable Terminal Blocks
■ Adjustable Sensitivity (nine levels, -60 to -10 dBV) ■ 14 preset gain ratios
■ Maximum one per chassis
■ Phantom Power (24 VDC) ■ Accessory sensing microphone available, model AN-9001
■ Removable Terminal Block ■ Maximum two per chassis
■ Maximum four per chassis T-001T
■ Required for VOX function and input metering Dual Line Output Expansion C-001T
Module with DSP Input/Output Control Module
D-001R ■ Two Balanced Line Outputs
■ Eight assignable control inputs for
Line Input Module with DSP ■ Digital Signal Processing activating Event, Volume Up/Down,
•10-Band Parametric EQ
■ Two RCA phone inputs per channel Mute, Power On/Off, Emergency
•Bass / Treble Mute or Sync On/Off
provides stereo summing
•Loudness
■ Digital Signal Processing ■ Eight assignable control outputs for
•High and Low Pass Filters
•10-Band Parametric EQ activating external relays
•Compressor
•Bass / Treble •TOA speaker EQ presets ■ Removable Terminal Block
•Loudness
■ Removable Terminal Block ■ Maximum one per chassis
•High and Low Pass Filters
•Compressor ■ Maximum three per chassis
RC-001T
RS-485 Control Modules
■ Allows use of up o 16 RS-485 remote
control panels
■ Bi-directional RS-485 communication
provides control and status feedback
display for each remote function
■ Dual ports allows independent home
runs for up to 8 modules each
■ 24V DC power adapter (optional AD-246) required for
each 1 port used
■ May be used in any control option slot on 9000M2 frame in
addition to a C-001T when spare slots are available
ACCESSORIES
ZM-9001 ZM-9002 ZM-9003
Remote Panel Remote Panel Remote Panel
■ Six assignable buttons to activate preset ■ Four assignable buttons to activate preset ■ Works with contact inputs on 9000M2
selection or volume up/down selection or volume up/down mainframe and on C-001T
■ Operates on Remote Volume Control ■ Variable knob to control volume ■ Six buttons - 4 locking with label strips
terminal on the 9000M2 back panel ■ Operates on Remote Volume Control and two momentary buttons - may be
terminal on the 9000M2 back panel assigned to control program change,
volume up/down, channel on/mute, emergency mute, power
and paging prohibit function.