You are on page 1/ 1

CLEAN ROOM OVENS 23

up to 250 °C

0 1000 2000 3000 [°C]

CR – Clean Room Ovens


The CR range of 250 °C clean room ovens comprises
nine standard models in sizes from the 30 litre model
to the 1790 litre model which, once processed through a
customer’s standard material entry regime, are suitable for
operation within an ISO 14644-1 Class 5 environment*.
All sources of particulate contamination are fully sealed. Their
easily cleaned stainless steel interiors and gloss white epoxy
exteriors prevent the shedding of particulate contamination.

*Federal Standard 209E Class 100 was superseded in 2001 CR 70 & CR 30


by ISO 14644-1 Class 5

Options (specif y these at time of order)

• A range of sophisticated digital controllers, multisegment


programmers and data loggers with digital communication
options is available (see page 100)
• Over-temperature protection (recommended to protect
valuable contents & for unattended operation)
Standard features • Access port for independent thermocouple
• 250 °C maximum operating temperature • Cable access port
• Carbolite Gero 301 controller with single ramp • Viewing window
to setpoint
• Frame to enable units to be stacked one upon another
• 30 to 1790 litre chamber volumes
• Lockable door
• Fully sealed low thermal mass insulation
• Door switch to isolate elements and fan
to avoid shedding fibres
• Fully customised through wall (flange fitted)
• Fully enclosed brushless fan motor
designs are available
• Perforated stainless steel shelves
• Door interlock activated by temperature alarm relay or
• Particle free silicone rubber door seal program segment output (EPC3016, CC-T1, EPC3008 or
• Membrane control panel with clear bright LED display nanodac)
• NEW Inert atmosphere option

Technical data
Dimensions: Dimensions: Shelf
CG H
Max. Temp. Temperature Heat-up Recovery Internal External Shelves loading Max.
temp. stability uniformity time time HxWxD HxWxD fitted / each / total Volume power
Model [°C] [°C] [°C] [mins] [mins] [mm] [mm] accepted [kg] [litres] [W]

685 x 460 x 670


CR/30 250 ± 0.2 ± 3.0 @ 250 °C 35 4 310 x 310 x 310 2/2 10 / 20 30 1000
(Bench-top or optional stand)
685 x 620 x 820
CR/70 250 ± 0.2 ± 3.0 @ 250 °C 35 4 310 x 470 x 470 2/2 10 / 20 68 1500
(Bench-top or optional stand)
925 x 620 x 820
CR/130 250 ± 0.2 ± 4.0 @ 250 °C 35 4 550 x 470 x 470 3/5 10 / 40 121 2000
(Bench-top or optional stand)
1145 x 620 x 820
CR/180 250 ± 0.2 ± 5.0 @ 250 °C 58 5 770 x 470 x 470 3/7 10 / 50 170 2500
(Bench-top or optional stand)
1360 x 940 x 970
CR/220 250 ± 0.2 ± 5.0 @ 250 °C 75 4 610 x 610 x 610 3/5 15 / 45 227 3000
(Bench-top or optional stand)
1670 x 940 x 970
CR/330 250 ± 0.2 ± 5.0 @ 250 °C 80 6 915 x 610 x 610 4/8 15 / 60 340 4500
(Floor-standing or optional stand)
1930 x 940 x 970
CR/450 250 ± 0.3 ± 5.0 @ 250 °C 75 9 1220 x 610 x 610 5 / 11 15 / 75 450 6000
(Floor-standing or optional stand)
2235 x 1395 x 970
CR/840 250 ± 0.3 ± 5.0 @ 250 °C – – 1525 x 915 x 610 6 15 / – 850 12000
(Floor-standing)
1930 x 1750 x 1580
CR/1790 250 ± 0.3 ± 5.0 @ 250 °C – – 1220 x 1220 x 1220 5 15 / – 1810 18000
(Floor-standing)

Please note:
- Minimum operating temperature approximately ambient plus 30 °C - Shelf loadings are based on evenly distributed weight
- Uniformity is measured in an empty chamber with vents closed, after a stabilisation period - External dimensions with door closed
- Maximum power and heat up time based on a 240 V supply - The uniform volume is smaller than the total chamber volume

www.carbolite-gero.com | Leading Heat Technology