Date 22/10/2024 KRUGER M & E INDUSTRIES CORPORATION

Company B3 Welborne Industrial Park, Bancal, Carmona,


Customer Ref. Cavite, 4116 Philippines
Manila 4116
Project TÜV Office
Email: [email protected]
Reference
Tel: +63‑2‑7 6223260 Fax:
Line 1 Website: www.krugerfan.com

Tag: FAF‑2 & EAF‑1


Fan Selection
Fan Type Centrifugal Mixed Flow Fan
Unit MXC-D 400
Operating Conditions Ducted
Required Volume 1782 m³/h
Required Pressure (Ps) 1.000 in. wg.
Total Pressure 1.082 in. wg.
Outlet Velocity 4.03 m/s
Fan Total Efficiency 63.9 %
Fan Static Efficiency 61.7 %
Fan Speed 1614 rpm
Air Temperature 30 °C
Altitude 1.0 m
Fan Absorbed Power 0.214 kW
FEG ‑
Motor Selection
Recommended Motor 0.37kW(4P D71)
Motor Speed 1614 rpm
Service Factor 73 %
Operating Limits
Max. Absorbed Power 4.10 kW
Max. Fan Speed 4250 rpm
Temperature (Min‑Max) ‑20 to 55 °C

Hz 63 125 250 500 1k 2k 4k 8k Overall


Lwi(Lin) 88 80 79 69 67 70 64 61 89 dB
Lwi(A) 61 64 71 66 67 71 65 59 76 dB(A)
Lpi(A) 44 46 53 48 50 53 47 42 59 dB(A)
* Sound data is for the inlet side * Sound Pressure Level 3.0 m, Room Conditions

A B C D E KG*
400 440 480 630 505 33.0
*weight excludes motor and drive All dimensions in mm.