AMES25-277NZ

AC-DC Converter

Click to

AMES25-277NZ ORDER
samples

The AMES25-277NZ is a 25W AC/DC converter that offers greater cost effectiveness
due to material normalization and production automation also leading to improved
reliability and performance. Offering a commercial input voltage range of 85-305VAC
and an output voltage range from 3.3-48V, this series will offer many benefits to your
new system design.
This new series offers great operating temperatures, from -30℃ to 70℃ and also
features an isolation of 4000VAC for improved reliability and system safety.
Furthermore, a high MTBF of 450,000h, output short circuit protection (OSCP), output
over-current protection (OCP) and an output over-voltage protection (OVP) come
standard with the series.
The AMES25-277NZ is suitable for street lighting controls, grid power,
Enclosed
instrumentation, industrial controls, communication and civil applications.

Features Summary

• Universal Input: 85 - 305VAC/100 - 430VDC AMES25-277NZ


528 48 4000 100
• Operating Temp: -30 °C to +70 °C
• High isolation voltage: Up to 4000VAC
125 125
• Low ripple & noise, 120mV(p-p) max.
305
• Output short circuit, over-current, over-voltage
protection 70

• Regulated Output 50
1000 15.6
85
3.3 9.9
0 1
-30 -25

Input voltage Output voltage Isolation Power Temp. range Derating


(VAC) (V) (VAC) (W) (°C) (°C)

Training Applications

Press Release

Coming Soon!

Power Grid Industrial Telecom Instrumentation

Product Training Video Application Notes


(click to open)

F 052e R4 www.Aimtec.com 1
Rev: 05/24/A
AMES25-277NZ
AC-DC Converter

Models & Specifications


Single Output
Max
Input Input Output Output Maximum Efficiency
Output Output Voltage
Model Voltage Voltage Voltage Current max capacitive @230VAC
Wattage Adjustable Range (V)
(VAC/Hz) (VDC) (V) (A) load (µF) Typ. (%)
(W)
AMES25-3S277NZ 85-305/47-63 100-430 19.8 3.3 2.85-3.6 6 5000 78
AMES25-5S277NZ 85-305/47-63 100-430 25 5 4.5-5.5 5 4000 81
AMES25-12S277NZ 85-305/47-63 100-430 25.2 12 10.8-13.2 2.1 3000 85
AMES25-15S277NZ 85-305/47-63 100-430 25.5 15 13.5-16.5 1.7 2000 86
AMES25-24S277NZ 85-305/47-63 100-430 26.4 24 22-27.6 1.1 1000 87
AMES25-48S277NZ 85-305/47-63 100-430 27.36 48 42-54 0.57 500 88
Note: Add suffix “-P” for optional terminal protective cover (ex. AMES25-3S277NZ-P is terminal with protective cover version) or suffix “-Q” for
conformal coating (ex. AMES25-3S277NZ-Q is conformal coating version).

Input Specifications
Parameters Conditions Typical Maximum Units
115VAC 0.6 A
Input current
230VAC 0.34 A
Cold start, 115VAC 20 A
Inrush current
Cold start, 230VAC 40 A
Leakage current 277VAC 0.5 mA

Output Specifications
Parameters Conditions Typical Maximum Units
3.3V output ±3 %
Voltage accuracy 5V output ±2 %
Others ±1 %
3.3, 5V output ±0.5 ±1 %
Line regulation
Others ±0.5 %
0-100% load, 3.3, 5V output ±1 ±2 %
Load regulation
0-100% load, Others ±0.5 ±1 %
48V output 120 mV p-p
Ripple & Noise*
Others 100 mV p-p
Start-up delay time 300 ms
115VAC 8 ms
Hold up time
230VAC 60 ms
* Ripple and Noise are measured at 20MHz bandwidth. Please refer to the application note for specific details. Measured with a 47μF electrolytic
capacitor and a 0.1μF ceramic capacitor.

Isolation Specifications
Parameters Conditions Typical Rated Units
Tested I/O voltage 60 sec, leakage current < 10mA 4000 VAC
Tested Input to GND voltage 60 sec, leakage current < 10mA 2000 VAC
Tested Output to GND voltage 60 sec, leakage current < 10mA 1250 VAC
Resistance (I/O, I/O to GND) 500VDC 100 MΩ

F 052e R4 www.Aimtec.com 2
Rev: 05/24/A
AMES25-277NZ
AC-DC Converter

General Specifications
Parameters Conditions Typical Maximum Units
Safety class Class I
Switching Frequency 65 KHz
Over Current protection Auto recovery ≥ 110 300 % of Iout
3.3V output, hiccup or voltage clamp 6.75 VDC
5V output, hiccup or voltage clamp 7.75 VDC
12V output, hiccup or voltage clamp 16.2 VDC
Over voltage protection
15V output, hiccup or voltage clamp 20.25 VDC
24V output, hiccup or voltage clamp 32.4 VDC
48V output, hiccup or voltage clamp 60 VDC
Short circuit protection Hiccup, Continuous, Auto recovery, Recovery time < 5 sec
Operating temperature See derating graph -30 to +70 °C
Storage temperature -40 to +85 °C
230VAC, 48V output 0.5 W
No load power consumption
230VAC, Others 0.3 W
-30°C to -25°C, 85VAC - 100VAC 6 % / °C
40 °C to 70 °C, 3V 1.33 % / °C
Power derating 50 °C to 70 °C, 5/12/15/24/48V 2 % / °C
85VAC - 100VAC 1.33 % / VAC
277VAC - 305VAC 0.72 % / VAC
Ambient temperature derating Operating altitude > 2000m 3.5 °C / 1000m
Temperature coefficient ±0.03 % / °C
Cooling Free air convection
Non-condensing, storage 95 % RH
Humidity
Non-condensing, operating >20 90 % RH
Case material Metal (5052 Aluminum, SGCC)
Weight 115 g
Dimensions (L x W x H) 3.15 x 2.16 x 0.98inch (80.0 x 55.0 x 25.0mm)
MTBF > 450 000 hrs (MIL-HDBK -217F, t=+25°C)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated
output load unless otherwise specified.

Safety Specifications
Parameters
Agency approvals CE EN62368-1
Design to meet IEC/UL 62368-1, GB4943
EMC - Conducted and radiated emission CISPR32 / EN55032, class B
Electrostatic Discharge Immunity IEC 61000-4-2 Contact ±6KV / Air ±8KV, Criteria B
RF, Electromagnetic Field Immunity IEC 61000-4-3 10V/m, Criteria A
Standards
Electrical Fast Transient/Burst Immunity IEC 61000-4-4 ±2KV, Criteria A
Surge Immunity IEC 61000-4-5 L-L ±1KV/L-G ±2KV, Criteria A
RF, Conducted Disturbance Immunity IEC 61000-4-6 10Vr.m.s, Criteria A
Voltage dips, Short Interruptions Immunity IEC 61000-4-11 0%, 70%, Criteria B

F 052e R4 www.Aimtec.com 3
Rev: 05/24/A
AMES25-277NZ
AC-DC Converter

Derating
Free Air Convection Free Air Convection at 25°C

3.3Vout model 100


100
100VAC

Output Power (%)


Output Power (%)

80 80
70

60
Safe Operating 60
Area Safe Operating Area
40 40
Input Voltage
85-305VAC 20
20
100-430VDC
0 0
-25 40 85 100 277 305
-30 -10 10 30 50 70 90 110 (100)(120) (390) (430)

Ambient Temperature º C Input Voltage VAC(60Hz) (VDC)

Dimensions
80.00
(3.15)
2-M3 L=3
The customer
1 system case

(1.00)
25.40
2 Power Supply Case
(0.30)

3
7.62

(2.16)
55.00

4 Screw

(1.65)
5 29.60
(0.26)

ADJ
6.50

55.00
(2.16) 10.50 L
(0.41)
2-M3 L=3 66.50 2.75
Max. 14.00 (2.62) (0.11)
Note:
(0.55)
Unit: mm(inch)
(0.55) (0.43)
14.00 11.00

Wire gauge: 22-12AWG


Screw terminal tightening torque: M3, 0.4N-m
Mounting screw tightening torque: M3, 0.4N-m
General tolerance: ±1.0(0.04)
At least one of the - location must be connected to PE

Single Pin Output Specifications


Pin Function
1 -V Input (L)
2 +V Input (N)
3 PE GND
4 -V Output
5 +V Output
ADJ Voltage adj knob

F 052e R4 www.Aimtec.com 4
Rev: 05/24/A
AMES25-277NZ
AC-DC Converter

-P terminal with protective cover version


80.00
(3.15)
2-M3 L=3
The customer
1 system case

(1.00)
25.40
2 Power Supply Case
(0.30)

3
7.62

(2.16)
55.00
4 Screw

(1.65)
29.60
5
(0.26)

ADJ
6.50

55.00
(2.16) 10.50 L
(0.41)
2-M3 L=3 66.50 2.75
Max. 14.00 (2.62) (0.11)
Note:
(0.55)
Unit: mm(inch)
(0.55) (0.43)
14.00 11.00

Wire gauge: 22-12AWG


Screw terminal tightening torque: M3, 0.4N-m
Mounting screw tightening torque: M3, 0.4N-m
General tolerance: ±1.0(0.04)
At least one of the - location must be connected to PE

Single Pin Output Specifications


Pin Function
1 -V Input (L)
2 +V Input (N)
3 PE GND
4 -V Output
5 +V Output
ADJ Voltage adj knob

NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to
www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical
drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless
otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and
other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous
environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with
Aimtec’s standard Terms of Sale available at www.aimtec.com.

F 052e R4 www.Aimtec.com 5
Rev: 05/24/A