0% found this document useful (0 votes)
24 views1 page

Final Submission Drawing of Plot No.187 F-T

FdSubmit

Uploaded by

roshanalikhan554
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
24 views1 page

Final Submission Drawing of Plot No.187 F-T

FdSubmit

Uploaded by

roshanalikhan554
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

PLOT NO.

158
25'
SCHEDULE OF OPENING
REAR LAWN 5'-0" WIDE
S./NO. TYPE WIDTH HEIGHT REMARKS
01- DW 4'-3'' 8'-0'' WOODEN GLAZED
5'

5'

MH MH 25'
02- D1 4'-0'' 7'-0'' //
6"

6"
6"

6" THICK RCC SLAB 03- D2 3'-6'' 7'-0'' //


9" THICK BRICK WALL 04- D3 2'-6'' 7'-0'' //

157
158
159
IN CMT (1:6) 05- W1 6'-6'' 6'-0'' ALLUMINIUM
06- W2 4'-3'' 6'-0'' //
9'-6"

9'-6"

9'-6"

O.H.W.T 07- W3 4'-0'' 4'-0'' //


08- V 2'-0'' 2'-0'' //
PLOT NO.188

A
SCHEDULE OF AREAS
PLOT NO. 186
3'

6" 3'

6" 3'

G.FLOOR
6"

6"

48'

48'
38'

38'

25'-0"x40'-0"

40'
TOTAL AREA OF PLOT

188
= 25'-0"X50'-0" = 1250.00 SFT
6"

6"

SITE
187
186
6" THICK RCC SLAB MAIN BUILDING 1000.00 SFT
9" THICK BRICK WALL
187 COV. AREA OF GROUND FLOOR :
IN CMT (1:6) A = 25'-0"x40'-0" = 1000.00 SFT
TOTAL = 1000.00 SFT
10'

10'

10'

10'

10'

10'

COV. AREA OF FIRST FLOOR :


33'-6"

33'-6"

B = 25'-0"x40'-0" = 1000.00 SFT


STREET NO. 03
T = 10"
R = 7" TOTAL = 1000.00 SFT
SEPTIC TANK
6"

6"

6"

6"

5'-0"

U G W T R.W.T
5'

5'
COV. AREA OF MUMTY :
6"

6"

STEEL
7'-9"x5'-0"
G/F BLOCK PLAN
GRATING
6" THICK RCC SLAB
KEY PLAN 12'-6"x19'-9"
GATE
7'-9" C = = 246.875 SFT
9" THICK BRICK WALL DRAIN LINE TO MAIN LINE WATER SUPPLY LINE DRAIN LINE TO MAIN LINE
T = 10"
IN CMT (1:6) R = 6.94" SEWER LINE TO MAIN LINE FROM MAIN LINE
SCALE : 1"=16'-0" TOTAL = 246.875 SFT
N.T.S
T = 10"
R = 6.94"
G. TOTAL = G/F + F/F + MUMTY
10'

10'

10'

10'

10'

10'

STREET NO. 03 (50'-0" WIDE) 25' G. TOTAL = 1000.00 +1000.00+246.875


GRAND TOTAL = 2246.875 SFT
SITE & SERVISES PLAN
F.F.L F.F.L F.F.L F.F.L F.F.L F.F.L
SCALE : 1"=16'-0" SUBMISSION DRAWING
2'-6"

2'-6"

2'-6"

2'-6"

2'-6"

2'-6"

G.L G.L G.L G.L G.L G.L


10" 10" 10" 10" 10" 10" 10"
PROPOSED DESIGN OF HOUSE AT PLOT
NO.187, ST-NO.03" FAISAL TOWN"
FRONT ELEVATION REAR ELEVATION B
BLOCK, C HOUSING PROJECT OF
SCALE : 1"=8'-0" SCALE : 1"=8'-0" X-SECTION AT A'- A' F.FLOOR
25'-0"x40'-0" ZEDEM INTERNATIONAL (PVT.) LTD.

40'
SCALE : 1"=8'-0" 1000.00 SFT CERTIFICATE
1 -THE SOUNDNESS &STABLITY OF STRUCTURE IS CERTIFIED
2 - THE FOUNDATION ARE QUITE ENOUGH TO BEAR LODE
25'
OF PROPOSED CONSTRUCTION
G.F.F.L 3/8"Ø-7"C/C 3/8"Ø-12"C/C 3/8"Ø-12"C/C 3/8"Ø-7"C/C
25' 3 - THE SANITARY&STORMWATER LINES WILL BE EFECTIVELY
+ 2'-0" +2'-0" 9"
REAR LAWN 5'-0" WIDE
9"
41" 41" 41 41" CONNECTED WITH MAIN LINES
3'-0" 3'-0"
2" 6'-41 2 4'-71
9" 5' 2 6'-41" 9" 6' 2 4'-71" 9" 9" 5' 2" 9" 6' 2" 9" G.L
5'

5'

3/8"Ø-8"C/C
OWNER'S NAME & SIGN:1
1'-6"
1'-6"

2 2
IN LET
1'-6"

8" 3/8"Ø-9"C/C 3/8"Ø-5"C/C OUT LET


V DW W2 V V BALCONY 1'-6" WIDE V MR.SHAKEEL AHMED.
S/O
9"

9"

9"

9"

C2 C2 C2 C2 C2 C2 3-1/2" Ø
1'-6"

BATH BATH BATH


W2 W2
BATH O.H.W.T
RAIN WATER 3/8"Ø-8"C/C 3/8"Ø-7"C/C
3/8"Ø-9"C/C
1/2" TH
C.M PLASTER
1/2" TH
C.M PLASTER F/F BLOCK PLAN MR.ABDUL LATIF.
2"

+2'-6" 3-1/2" Ø WITH 5% PADLO WITH 5% PADLO N.I.C. NO.37105-0233536-5.


DRESS

DRESS

5'-71
2" 4'-6"

4'-6"

2" 4'-6"

4'-6"
DRESS

DRESS

3/8"Ø-9"C/C 3/8"Ø-9"C/C
5'-0"x4'-6" 5'-0"x4'-6" 5'-0"x4'-6" 5'-0"x4'-6" 6'-1½"x5'-7½" P.C.C. (1:4:8)
3/8"Ø-7"C/C 3/8"Ø-7"C/C 3/8"Ø-7"C/C SCALE : 1"=16'-0"
SCHEDULE OF RCC SLAB
2"

2"
41

41

D3 D3 D3 D3 12" 3/8"Ø-9"C/C
3" 3"
41

41

3/8"Ø-8"C/C HAUNCH 6"X6"


6'-11"
2
SECTION DETAIL OF STAIRS 3/8"Ø-6"C/C
3/8"Ø-9"C/C
S./NO. TH. MAIN BARS DIST. BARS REMARKS
S1 6" 5/8"Ø5" C/C 5/8"Ø7" C/C TWO WAY SLAB
W
N.T.S P.C.C. (1:4:8:)

WAT
AT
BED BED
E
BED BED
RS
LO 1'-1 1/2" 1'-1 1/2"
S2 6" 1/2"Ø6" C/C 1/2"Ø8" C/C TWO WAY SLAB
11'-0"x10'-0" 11'-0"x10'-0"

ER
PE
11'-9"x10'-0" 11'-9"x10'-0" X-SECTION OF RAIN WATER TANK
10'

10'

10'

10'

12'-6" S3 6" 1/2"Ø5" C/C 1/2"Ø7" C/C TWO WAY SLAB

SLOP
9" 11'-9" 9" 11' 9" 9" 11'-9" 9" 11' 9" 9" 11' 9" #3@6"c/c 9" #4@6"c/c #4@6"c/c 9" #3@6"c/c #3@6"c/c #3@6"c/c
ARCHITECT'S SIGN & ENG. SIGN

E
4#6 9" #4@6"c/c #4@6"c/c 9" 4#6
9"

#4@6"c/c
9"

9"

9"

9"

C2 D2 D2 C2 C2 D2 D2 C2 C2
C2 C2 #4@8"c/c
SLIDING DOOR

SLIDING DOOR

2"
40'

40'

40'

40'
43'
50'

+2'-6"
STORE #4@6"c/c #4@6"c/c
10'-101

11'-0"x10'-10½"
KITCHEN STORE
43'
50'

LOUNGE SITTING 12'-6"


8'

8'

7'-1½"x8'-0" 7'-1½"x8'-0" W1 #4@6"c/c #4@6"c/c #3@8"c/c


16'-0"x10'-0" 16'-0"x10'-0"
10'

10'

#3@6"c/c
19'-9"
41
2" 41
2"
9" 7'-11
2" 16' 9" 9" 7'-11
2" W3 16' 9" #6 Rings
C2 W3 C2 C2 C2 C2 #3@8"c/c
D1 D2
9"

9"

D1

2"
41
C

19'-9"
OPE
3'-6"
T = 10"

3'-6" +2'-0" #4@6"c/c


MUMTY
2 3'-6"

3'-6"

3'-6"

R = 7"

#4@8"c/c #4@8"c/c
MUMTY
9"

9"

UP C2 UP C2
W. STOPPER

L
11'-0"x7'-0"

ER S
12'-6"x18'-9"
41"

D2 D2 #3@8"c/c 6"x 6" FILLET


8'-41"

7'
246.875 SFT
2

#4@8"c/c #4@8"c/c

WAT
3#6
C. JOINT
3'-6"

3'-6"

T = 10"
R = 7"
DN P.C.C 1:4:8
+1'-6" +2'-6" D2
2"
14'-11

C2 T = 10" C2 C2 W1
MUMTYBLOCK PLAN
12'-11"

2"

R =6.94"

9"
2#4
2

Typ. Section Of Under Ground Water Tank


12'-11

DRAWING 3'-6" 9'-3" LIVING #4@8"c/c


10'-3"

41"
PORCH 10'-0"x12'-1½" 10'-0"x12'-1½"
2"

2
T = 10"
APPROVAL
12'-101

12'-9"x12'-10½" R = 6.94"
W.C SCALE : 1"=16'-0" Slab Steel Roof Slab Slab Steel 3#6
DN 4'-0"x5'-0" 3/8"Ø-7"C/C 3/8"Ø-12"C/C 3/8"Ø-12"C/C 3/8"Ø-7"C/C
VERANDAH V RAIN WATER 9"
9"
9" 12'-9" 9" 10' 9" 8'-41" D3
3'-0" 3'-0"
W1 2 W1
G.L
Section of O.H.Water Tank
1'-6"9"

9"

9"

9"
C1 C2 C2 C1 C2 C2
1'-6"

1'-6"
1'-6"

1'-6"
BALCONY BALCONY IN LET 3/8"Ø-9"C/C 3/8"Ø-5"C/C OUT LET
N.T.S
MUMTY PLAN
5'

5'

DRIVEWAY
+ 1'-0" STEEL
GRATING
FRONT LAWN 5'-0"WIDE
FIRST FLOOR PLAN 3/8"Ø-7"C/C 1/2" TH 1/2" TH
± 0'-0" MAIN GATE SCALE : 1"=8'-0" SCALE : 1"=8'-0" 3/8"Ø-9"C/C C.M PLASTER
WITH 5% PADLO
C.M PLASTER
WITH 5% PADLO
9" 11'-9" 9" 11'-9" 3/8"Ø-9"C/C 3/8"Ø-9"C/C
25' 3/8"Ø-7"C/C 3/8"Ø-7"C/C 3/8"Ø-7"C/C
GROUND FLOOR PLAN
3/8"Ø-9"C/C
3/8"Ø-6"C/C 3/8"Ø-8"C/C HAUNCH 6"X6"
3/8"Ø-9"C/C
SCALE : 1"=8'-0"

9"
P.C.C. (1:4:8:)

18"
9"
9"

6" 6"
GATE 9" X-SECTION OF SEPTIC TANK
Plinth Beam for 9" Th. Walls
9" 9" SIZE:- 9" X 9" 4'-6"
C.2 Lintel Beam for 9" Th. Walls
BARS:- 2-Ø1/2" (Top) 9"
SIZE:- 9" X 9"
6'-6"

SIZE:- 9" X 9"


BARS:- 3-Ø1/2" (Top) BARS:- 2-Ø1/2" (Bottom) C.1
6'

BARS:- 4-Ø1/2"
RINGS:- Ø3/8"@8" BARS:- 3-Ø1/2" (Bottom) RINGS:- Ø3/8"@8" SIZE:- 9" X 18" #4@8" (TOP)
RINGS:- Ø3/8"@8" BARS:- 6-Ø1/2"
9" #4@8" (BOTTOM)

#4@8" (BOTTOM)
RINGS:- Ø3/8"@8"
9" 11'-9" 9" 11'-9"
9"

#4@8" (TOP)
25'
4½" 1 1

4'-6"
BRICK WALL
DETAIL OF BOUNDARY WALL BRICK WALL 2 COATS OF HOT BITUMEN
BLINDED WITH SAND
SCALE : 1"=8'-0" 2 COATS OF HOT BITUMEN BRICK WALL
BLINDED WITH SAND FL 2 COATS OF HOT BITUMEN
4#4 BLINDED WITH SAND
FL PLINTH BEAM
(PB-1) 9"x9" #3@8"
PLINTH BEAM 4#4

2'-6"
FL
(PB-1) 9"x9" #3@8"
4#4 SECTION OF FOOTING (F-1)

2'-6"
PLINTH BEAM
BRICK WALL
(PB-1) 9"x9" #3@8"
Scale = NTS 9"

2'-6"
NSL
6"

NSL
BRICK WALL
RCC COL.

12"

1'-9"
NSL
R.C.C 2 COATS OF HOT BITUMEN
BEAM OVER WITH 1/2" TH: PLASTER (1:6)
4012" 2 COATS OF HOT BITUMEN
NSL

9"

4'

1'-9"
OVER WITH 1/2" TH: PLASTER (1:6) 13½"

3" 12" 12"


5'-0" 2 COATS OF HOT BITUMEN

4'
10'

54" OVER WITH 1/2" TH: PLASTER (1:6)

3" 12" 12"

1'-9"
4'
13½" #4@8"

3" 12" 12"

4'-0"
PCC(1:4:8)

6'-0"
PCC(1:4:8)

3" 12"
F.F.L +2'-6" #4@8"
+1'-6" STEEL GRATING PCC(1:4:8)
+1'-0" #4@8" #4@10"
2'-6"

ROAD LEVEL PCC(1:4:8)


+0'-0" #4@10" 3'-6" #4@8"
3'-0" 4'-0" #4@10" #4@8"
3'-6" #4@8"
DETAIL OF RAMP DRAIN
SECTION OF FOOTING ( WF-1)
3'-3" SECTION OF FOOTING ( WF-2) 4'-0"
4'-6"
SCALE : 1"=8'-0" Scale = NTS 4'-9"
Scale = NTS
SECTION OF FOOTING ( WF-3)
Scale = NTS SECTION 1-1 RAIN WATER HARVESTING DETAIL
SCALE : 1"=8'-0"
NEW. MANAN
MANAN

You might also like