TS-103(F)
TYPE S Flowmeter
3/4”, 1”, & 2”
MODEL 157, 600 & 800 REGISTERS
DESCRIPTION system.
The Type S flowmeters utilize the nutating disc principle
positive displacement measuring chamber technology. LONG SERVICE LIFE
This design results in an extremely accurate flowmeter Rugged construction of Type S flowmeters, along with
that is insensitive to small changes in viscosity and flow continual design improvements, assure a system that
profile disturbances. Each flowmeter includes a base is simple to operate and economical to use. The overall
unit that houses and protects the measuring chamber design of the Type S yields a meter with the ability to
and a gear train. Registers provide reset of delivery and measure a wide variety of mild corrosive and erosive
totalization. A wide variety of digital pulse transmitters liquids. Furthermore, Type S flowmeters have been
permit remote operation and monitoring. proven through more than 100 years of manufacturing
experience.
DESIGN FEATURES
EASE OF MAINTENANCE
SUSTAINED ACCURACY The Type S flowmeters do not require elaborate
The Red Seal design nutating disc measuring chamber timing gears or difficult adjustment procedures to
is both accurate and dependable. The double case ensure proper functioning of the measuring element.
feature reduces the effect of higher pressure losses Replacement of a worn or damaged measuring
in measuring viscous liquids. In addition, the disc chamber, gear train, or register is both simple to
design permits accurate measurement of liquids with accomplish and requires very little time.
suspended solid particles (up to 0.22 mm/0.009 in)
without major damage or erosion to the measuring POSITIVE AND ACCURATE REGISTRATION
element for intermittent (i.e., batching) operations. Time proven positive adjustment through Red Seal
calibration change gears allows changes in increments
FLEXIBILITY as small as 0.15% and reduces errors caused by
The rugged bronze outer body components are mechanical wear or changes in process fluid.
compatible with hundreds of nonacidic liquids. Threaded
end connections allow rapid conversion from right ASSEMBLY OPTIONS
to left hand flow with provided coupling sets. Pulse Normally assembled as a right hand flow: inlet on left,
transmitters, when used the BATCHMATE 1500 with outlet on right. Optional left hand flow: inlet on right,
electronic batch controller and a solenoid valve, provide with outlet on left requires rotating the register by 180°.
an economical and dependable local or remote batching
www.redsealmeasurement.com
MECHANICAL PRESET VALVES
Single and double-stage mechanical auto-stop valves
are available for all 1”and 2” Type S Flowmeters.
They must accompany an appropriate 800 Series
mechanical preset register.
Single Trip preset valves are either fully open or fully
closed. They may be specified for flow rates up to 190
LPM (50 GPM) where hydraulic shock is not a factor.
Single trip valves are also used with larger flowmeters
to measure liquids that have viscosities over 10,000
SSU/1400 cPs.
Double Trip preset valves permit controlled valve
closing. Controlled valve closing reduces the potential
for hydraulic shock on both the dispensing lines and
the meter itself. Double trip valves are recommended
when measuring liquids with viscosities less than
10,000 SSU/1400 cPS that have either high operating
pressures or flow rates exceeding 190 LPM (50 GPM).
Preset Valves should be mounted on the meter outlet
in order to keep the flowmeter full and to maintain
accuracy. A fine mesh line strainer should be installed
upstream of the flowmeter and valve combination. The
purpose of the strainer is to prevent foreign particles
from damaging both the measuring chamber in the
Type 2” Type S witch 800 Series flowmeter and the piston/cylinder assembly in the
Register and Auto-Stop Valve preset valve.
MECHANICAL REGISTER SWITCHES
Model 23 Auto-Switches are micro switch devices
that attach to 800 Series Preset Registers. They
control pump and/or solenoid valves that are used
in place of mechanical auto-stop valves. Upon
completion of delivery, the auto-switch provides
contact closures to close the valve stages and finally
de-energize the pump. This orderly system shutdown
reduces wear, saves energy, and alleviates hydraulic
shock on the system.
Model 23A switches are Double-Pole Double-Throw
(DPDT). They provide two (2) switch closures for
2-stage valve shut down, with the final closure de-
energizing.
Model 23B switches are Single-Pole Double-Throw.
They provide one (1) switch closure for single stage
valve shut down and pump de-energizing.
Both Models 23A and 23B switches are U.L. listed
for hazardous location usage Class I, Group D; at 15
amps at 125 to 250 VAC; 0.5 amps at 125 VDC; and
0.25 amps at 250 VDC.
Model 23 Auto-Switch on Back
of 800 Series Preset Register
ACCURACY
All Red Seal Type S nutating disc
flowmeters are functionally tested for PRESSURE LOSS CURVES FOR WATER
proper operation, verified for accuracy
and calibrated to an approved unit of
measure.
• Maximum error, based on a 10:1
turndown, shall not exceed ± 1.0%,
as a percentage of rate for the entire
flow range.
• For reduced variables, i.e.:
turndown, temperatures, pressures
and higher viscosities; accuracies of
± 0.5% or better may be obtained.
• Repeatability is 0.2%
Type S with Model 157 Register
FLOWMETER OPERATING SPECIFICATIONS
CATEGORY 3/4” TYPE S 1” TYPE S 2” TYPE S
Type of Measuring Element Positive Displacement Double Case Nutating Disc
End Connections (Threaded) 3/4” 1” Not Applicable
External NPT External NPT
End Connections (Flanged) 11/2”, 2 bolt oval, 150# 2”, 4 bolt round,125#
w/800 Register
Temperature Rating (T Max) 121°C (250°F)
Pressure Rating (P max) 10.34 bar (150 psi) @ 121°C (250°F) 8.6 bar (125 psi) @ 121°C
Pressure Rating (P min) Dependent upon through-put, viscosity, and the torque required to drive the register
Flow Range (Q Max) 113 LPM (30 GPM) 189 LPM (50 GPM) 616 LPM (160 GPM)
METER
(Q Min) 11.3 LPM (3 GPM) 19 LPM (5 GPM) 62 LPM (16 GPM)
Totalized Units 10 Litres, 10 Kilograms, 10 pounds, 1 US Gallon, or 10 US Gallons
Enclosure Class Totally mechanical. If interfaced with a pulse transmitter, the rating of the device applies.
Power Supply None, unless fitted with a pulse transmitter, then the rating of the installed device applies.
Main Body Material Bronze (over 75% CU)
Main Body Cover Material Bronze (over 75% CU)
Disc Piston 1” Glass Phenolic, 11/2 & 2” Ryton
Shaft Material Stainless Steel
Gasket Material Viton, Klingersil
Type of Coupling Mechanical
Register Type Model 157 Register1 Model 157 Register1
Model 600 Register2 800 Series Register3
Alternate Units of Measure Only with pulse transmitter and BATCHMATE (Batch Control Computer)
COUNTER AND OPTIONS
Auto Stop Valve Single and Double Trip (Mechanical)
Switch
a. Single Stage Model 23 B
b. Double Stage Model 23 A
Transmitter Type Consult Form TS-510
Transmitter Output Consult Form TS-510
Air Eliminator Not Available
Strainer Size and Mesh Recommend procure locally.
Mesh dependent upon viscosity
Manufacturer Red Seal Measurement
Model Number TS-075 TS-100 TS-200
1
Note: Non-Resettable, 7 digit Totalizer
Capacity: Totalizer 9999999
2
Note: Resettable (5 digit), 8 digit Totalizer
Capacity: Totalizer 99999999: Reset 99999
3
Note: Resettable (5 digit), 8 digit Totalizer
Capacity: Totalizer 99999999: Reset 99999
WEIGHT Kilograms (Pounds)
TYPE S METER SIZE
REGISTER AND PULSE TRANSMITTER DATA
3/4” 1”
Model 157 Standard Unit 7.3 (16) 12.7 (28)
Model 157 with Dry Reed or Hall Effect Pulse Transmitter 9.1 (20) 14.5 (32)
Model 600 Standard Unit 10.9 (24) 15 (33)
Model 600 with Dry Reed or Hall Effect Pulse Transmitter 11.8 (26) 15.9 (35)
DIMENSIONAL DATA
Model 30 Pulse Transmitter with Model 157 Register
3/4” and 1” Type S Flowmeter with Model 600
Register and Pulse Transmitter
3/4” and 1” Type S Flowmeter with
Model 157 Register
DIMENSIONS Millimeters (Inches)
NOTE: A1 = Model 157 Standard
A2 = Model 157 with Model 30 Pulse Transmitter
Meter
A1 A2 B C D E F G H I J K
Size
O.D. Threads
Inches Per inch
210 248 289 114 165 30 143 19 * 64 3 0.75
3/4” *
(8.25) (9.75) (9.00) (4.50) (6.50) (1.19) (5.63) (0.75) 11.5 (2.50) (0.11) NPT
1.295
NPS
* *
235 273 273 137 191 51 191 * 67
1” 11.5 1.0
(9.25) (10.75) (10.75) (5.38) (7.50) (2.00) (7.50) 1.626 (2.63)
NPS NPT
NOTE: Item H (Spud End Connections) on Meter Body is National Pipe Straight (NPS). Coupling Sets
provided with meter are 1/2”, 3/4” and 1” to fit National Pipe Tapered (NPT) threads.
DIMENSIONAL DATA
25 mm (1 in) Type S with Model 157 Register
Model 157 Register with Pulse
Transmitter
25 mm (1 in) Type S with 800 Series Register
DIMENSIONAL DATA
DIMENSIONS - Millimeters (Inches)
50 mm (2 in)
Type S with Model 157 Register
Flowmeter A B C D E F G H Weight
Size kg (lb)
50 311 216 432 91 -- 473 59 54 32.7
(2) (12.25) (8.50) (17) (3.60) -- (18.63) (2.31) (2.12) (72)
50 mm (2 in)
Type S with 800 Series Register
Flowmeter A B C D E F G H Weight
Size kg (lb)
50 311 216 432 91 232 480 59 54 55.3
(2) (12.25) (8.50) (17) (3.60) (9.13) (18.88) (2.31) (2.12) (122)
Pressure Drop Versus Flow Rate